SIST EN 50131-6:2008/A1:2014
(Amendment)Alarm systems - Intrusion and hold-up systems -- Part 6: Power supplies
Alarm systems - Intrusion and hold-up systems -- Part 6: Power supplies
This European Standard specifies the requirements, performance criteria and testing procedures for PS to be used as part of Intrusion and Hold up Alarm Systems. The PS shall either be an integral part of an I&HAS component or stand-alone. The control functions of the PS may be incorporated as part of the PS device, or may be provided by another I&HAS component e.g. a CIE. This European Standard is not applicable when the PS requirements for I&HAS components are included within the relevant product standard. The requirements correspond to each of the four security grades given in the European Standard EN 50131-1, Alarm Systems - Intrusion and Hold-Up Systems;system requirements. Requirements are also given for four environmental classes covering applications in internal and outdoor locations. This standard covers mandatory functions which shall be provided on all PS and optional functions which may be provided. Other functions associated with I&HAS not specified in this standard may be provided. Such functions shall not affect the requirements of any mandatory or optional functions.
Alarmanlagen - Einbruch- und Überfallmeldeanlagen - Teil 6: Energieversorgungen
Systémes d'alarme - Systémes d'alarme contre l’intrusion et les hold-up - Partie 6: Alimentation
Alarmni sistemi - Sistemi za javljanje vloma in ropa - 6. del: Napajalniki - Dopolnilo A1
Ta evropski standard določa zahteve, merila uspešnosti in preskusne postopke za napajalnike za uporabo kot del alarmnega sistema za javljanje vloma in ropa. Napajalnik je lahko sestavni del komponente I&HAS ali samostojen. Krmilne funkcije napajalnika je mogoče vključiti kot del napajalne naprave ali pa jih lahko zagotavlja drug sestavni del I&HAS, npr. CIE. Ta evropski standard se ne uporablja, kadar so zahteve napajalnika za sestavne dele I&HAS zajete v ustreznem standardu izdelka. Zahteve ustrezajo vsakemu od štirih varnostnih razredov, ki so navedeni v evropskem standardu EN 50131-1 Alarmni sistemi - Sistemi za javljanje vloma in ropa: sistemske zahteve. Zahteve so podane tudi za štiri okoljske razrede, ki zajemajo uporabo v zaprtih prostorih in na prostem. Ta standard zajema obvezne funkcije, ki jih je treba zagotoviti pri vseh napajalnikih in neobveznih funkcijah, ki so morda na voljo. Lahko so na voljo druge funkcije, povezane z I&HAS, ki niso navedene v tem standardu. Take funkcije ne smejo vplivati na zahteve obveznih ali izbirnih funkcij.
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
SIST EN 50131-6:2008/A1:2014
01-september-2014
Alarmni sistemi - Sistemi za javljanje vloma in ropa - 6. del: Napajalniki - Dopolnilo
A1
Alarm systems - Intrusion and hold-up systems -- Part 6: Power supplies
Alarmanlagen - Einbruch- und Überfallmeldeanlagen - Teil 6: Energieversorgungen
Systémes d'alarme - Systémes d'alarme contre l’intrusion et les hold-up - Partie 6:
Alimentation
Ta slovenski standard je istoveten z: EN 50131-6:2008/A1:2014
ICS:
13.310 Varstvo pred kriminalom Protection against crime
13.320 Alarmni in opozorilni sistemi Alarm and warning systems
SIST EN 50131-6:2008/A1:2014 en,fr
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
SIST EN 50131-6:2008/A1:2014
---------------------- Page: 2 ----------------------
SIST EN 50131-6:2008/A1:2014
EUROPEAN STANDARD EN 50131-6:2008/A1
NORME EUROPÉENNE
EUROPÄISCHE NORM
June 2014
ICS 13.310
English Version
Alarm systems - Intrusion and hold-up systems - Part 6: Power
supplies
Systèmes d'alarme - Systèmes d'alarme contre l'intrusion et Alarmanlagen - Einbruch- und Überfallmeldeanlagen - Teil
les hold-up - Partie 6: Alimentation 6: Energieversorgungen
This amendment A1 modifies the European Standard EN 50131-6:2008; it was approved by CENELEC on 2014-03-17. CENELEC
members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this amendment the
status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This amendment exists in three official versions (English, French, German). A version in any other language made by translation under the
responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as
the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2014 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN 50131-6:2008/A1:2014 E
---------------------- Page: 3 ----------------------
SIST EN 50131-6:2008/A1:2014
EN 50131-6:2008/A1:2014 – 2 –
Foreword
This document (EN 50131-6:2008/A1:2014) has been prepared by CLC/TC 79 "Alarm systems".
The following dates are fixed:
• latest date by which this document has
(dop) 2015-03-17
to be implemented at national level by
publication of an identical national
standard or by endorsement
• latest date by which the national
(dow) 2017-03-17
standards conflicting with this
document have to be withdrawn
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such
patent rights.
__________
---------------------- Page: 4 ----------------------
SIST EN 50131-6:2008/A1:2014
– 3 – EN 50131-6:2008/A1:2014
1 Modification to the Scope
th
Add the following new 5 paragraph:
"This European Standard does not deal with requirements for compliance with EC regulatory
Directives, such as the EMC Directive, Low Voltage Directive, etc. except that it specifies the
equipment operating conditions for EMC susceptibility testing as required by EN 50130-4."
2 Modifications to Clause 2, Normative references
rd
Replace the 3 entry with the following:
"EN 50131-1 2006 Alarm systems – Intrusion and hold-up systems – Part 1: System
+ A1 2009 requirements"
Delete the entry for EN 60065.
Add the following new entries:
"EN 60068-2-14 2009 Environmental testing – Part 2-14: Tests – Test N: Change of
temperature (IEC 60068-2-14:2009)
EN 60068-2-75 1997 Environmental testing – Part 2-75: Tests – Test Eh: Hammer tests
(IEC 60068-2-75:1997)"
Delete the entry for EN 60950 series.
Delete the entry for EN 61000-6-3.
3 Modification to Clause 3, Definitions and abbreviations
3.1.11
open by normal means
rd
Delete the 3 word “by” in the definition.
4 Modification to Clause 4, Functional requirements
4.1 General
Replace Figure 1 with the following:
"
---------------------- Page: 5 ----------------------
SIST EN 50131-6:2008/A1:2014
EN 50131-6:2008/A1:2014 – 4 –
PPS
EPS Independent
power outputs
SPPS PU
to I&HAS
components
APS
SD
Type A PS
PS
I&HAS
PPS
EPS Independent
power outputs
SPPS PU
to I&HAS
components
APS
Replacement SD
SD
or non-continuous
Type B PS
recharge source
PS
for SD not charged
by I&HAS
I&HAS
Independent
power outputs
PU
to I&HAS
components
Type C PS
PPS
SD
PS
I&HAS
NOTE For PS types A and B, where there is no SPPS, the PPS and EPS are identical.
Figure 1 — Power supply types"
---------------------- Page: 6 ----------------------
SIST EN 50131-6:2008/A1:2014
– 5 – EN 50131-6:2008/A1:2014
Add the following new paragraph immediately before Table 1:
"If a function is provided that is optional for a particular grade and a claim of compliance is made, it
shall meet the applicable requirements for the grade for which compliance is claimed (if any are
given). If there are no specifications for the function at the grade in question, the requirements for any
higher grade (as identified by the PS manufacturer) shall apply."
In Tables 1 and 2, replace all references “n/a” with “NA”.
4.2.1 Loss of EPS
Replace the text of this subclause with the following:
"A loss of EPS condition shall be detected within 10 s.
When the EPS has been continuously disconnected for a minimum of 10 s, an EPS fault signal or
message shall be generated within 60 s.
When the EPS has been continuously re-connected for a minimum of 1 s an EPS fault signal or
message shall be removed within 60 s."
4.6 Short Circuit Protection
nd
In the 2 paragraph, replace “and reset…” with “and replacement or reset…”.
4.11.1 Tamper Protection
Replace the text of the whole subclause with the following (including a new table):
"The construction of the PS housing(s) shall meet the tamper protection requirements of EN 50131-1
and the impact requirements for the appropriate grade according to Table 4. IK impact ratings are
detailed in EN 62262.
This requirement permits the housing to be damaged, provided that a tamper signal or message shall
be generated before unauthorised access to internal elements is possible.
Where the PS is distributed within the housing of other components of the I&HAS, then the tamper
protection of such housings shall comply with the standard for that component.
Provision shall be made to allow adequate fixing of the housing to the mounting surface.
Means of access to internal elements of a PS shall be robust and mechanically secured.
Table 4 – Tamper protection
PS Grade 1 Grade 2 Grade 3 Grade 4
Int Ext Int Ext Int Ext Int Ext
Severity level (IK code)
04 07 06 07 06 07 06 07
(design specification)
Impact energy (Joule)
0,5 J 2 J 1 J 2 J 1 J 2 J 1 J 2 J
(test condition)
Int = Inside the supervised premises
Ext = Outside the supervised premises (indoor or outdoor).
---------------------- Page: 7 ----------------------
SIST EN 50131-6:2008/A1:2014
EN 50131-6:2008/A1:2014 – 6 –
In grades 1 and 2 this requirement does not include indicators (EXAMPLE: display); in grades 3 and 4
such indicators and any other apertures accessible to a level 1 user are included."
Renumber the remaining existing tables consequently.
4.11.2 Tamper Detection
Replace former Table 4 (current Table 5) with the following:
"Table 5 — Tamper detection
Event to be detected Grade 1 Grade 2 Grade 3 Grade 4
Access to the inside of the
M M M M
housing
Removal from mounting Op Op M M
Removal from mounting
(using wire free Op M M M
communication with CIE)
a
Penetration of housing Op Op Op M
M = Mandatory
Op = Optional
a
When located outside the supervised premises.
"
4.11.2.1 Access to the inside of the housing
Add the following (including the new Table 6) at the end of the subclause:
"The housing shall not permit the introduction of tools of dimensions as specified in Table 6 to defeat
the tamper detection before it has operated.
Table 6 – Tool dimension for tamper detection
Dimensions in millimetres
Grade 1 Grade 2 Grade 3 Grade 4
Steel rod as specified in
2,5 2,5 1 1
EN 6
...