Abstract

This European Standard applies to thermoplastic (PVC) insulated flexible flat tinsel flexible cables. The cables are of rated voltage U0/U 300/300 V. The cables are intended for the connection of small appliances to the fixed supply. The maximum conductor operating temperature for the cable in this standard is 40 °C. NOTE   HD 516 contains extensive guidance on the safe use of cables in this standard. This EN 50525-2-71 should be read in conjunction with EN 50525-1, which specifies general requirements.

Status
Published
Public Enquiry End Date
28-Feb-2009
Publication Date
15-Jun-2011
Technical Committee
IEKA - Electric cables
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
08-Jun-2011
Due Date
13-Aug-2011
Completion Date
16-Jun-2011

Buy Documents

Standard

SIST EN 50525-2-71:2011

English language (9 pages)
Preview
Preview
e-Library read for
×1 day

SIST EN 50525-2-71:2011 is the Slovenian adoption of EN 50525-2-71:2011 from CENELEC for thermoplastic PVC-insulated flexible flat tinsel cables. It specifies the construction, dimensions, marking and test regime for H03VH-Y cords rated 300/300 V, intended for connecting small appliances to the fixed supply.

What does SIST EN 50525-2-71:2011 specify?

SIST EN 50525-2-71:2011 applies to thermoplastic (PVC) insulated flexible flat tinsel cables for low-voltage energy use. It sets the product type, the voltage rating, the maximum conductor operating temperature, and the test and data framework used to verify the cable.

The document is organized into four clauses and three normative annexes:

AnnexWhat it covers
Annex ATests for cables to EN 50525-2-71
Annex BGeneral data for Type H03VH-Y
Annex CMechanical tests on completed cables

Clause 1 gives the scope, Clause 2 lists the referenced standards, Clause 3 points to the terms and definitions in EN 50525-1, and Clause 4 gives the construction and requirements for Flexible cables - H03VH-Y.

What are the key requirements of SIST EN 50525-2-71:2011?

SIST EN 50525-2-71:2011 defines a specific flat cable construction and then ties compliance to dimensional, electrical, mechanical and fire tests. In practice, manufacturers use it to design the cable, set inspection limits, and choose the required type tests.

Construction and cable identity

Clause 4.1 defines H03VH-Y as a two-conductor flat tinsel cable. Each conductor consists of strands or groups of strands made from flattened copper or copper alloy wires wound on a cotton, polyamide or similar thread, and the two conductors are laid parallel.

Clause 4.1 also requires PVC insulation of Type TI 2 to EN 50363-3, with grooves on both sides between the conductors to make separation easier. The cable must be marked with the CENELEC code H03VH-Y, so the product can be identified in manufacture, testing and purchasing.

Performance and conformity checks

Clause 4.2 says each cable shall meet EN 50525-1 as well as the particular requirements in this part. It also sends testing to Annex A and limits dimensions to the ranges in Annex B. For a buyer or quality manager, this is the practical checklist for acceptance: the cable must be the right construction, the right size, and within the stated electrical limits.

Electrical, dimensional and material testing

Annex A brings together the tests used to verify the cable. It covers conductor resistance, voltage test at 2 000 V, insulation resistance at 70 °C, long-term resistance of insulation to d.c., absence of faults in insulation, constructional checks, thickness of insulation, overall diameter, material tests on the insulation, impact at - 5 °C, and the fire test for vertical flame propagation on a single insulated wire or cable.

This matters because the standard does not rely on one result alone. A cable is checked as a complete product, so design, materials and workmanship all have to work together.

Mechanical endurance of completed cables

Annex C gives the bending test and the snatch test for completed cables. The bending test requires 60 000 bending cycles and no interruption of current during the test; afterward the sample must withstand a voltage test at 1 500 V between the conductors connected together and water. The snatch test also requires no interruption of current.

For production and type testing, this shows whether the finished cord can survive repeated flexing and handling without failing in service.

What terms does SIST EN 50525-2-71:2011 define?

SIST EN 50525-2-71:2011 uses the terms and definitions from Clause 3 of EN 50525-1. A few key terms and abbreviations used in this part are:

  • PVC - Polyvinyl chloride, the thermoplastic insulation material used on the cable.
  • U0/U - The rated voltage notation used for the cable, here 300/300 V.
  • H03VH-Y - The CENELEC code used to identify this cable type.
  • TI 2 - The PVC insulating compound type required by EN 50363-3.
  • Small appliances - The intended end-use for the cable connection to the fixed supply.
  • Fixed supply - The supply arrangement to which the appliance is connected.

Who uses SIST EN 50525-2-71:2011?

SIST EN 50525-2-71:2011 is used by cable manufacturers, test laboratories, conformity assessors, appliance makers, and purchasers who need a specified flat cord for small appliances. It is also relevant to quality managers who verify construction, marking and test compliance, and to engineers who select a cable design and define acceptance criteria.

What changed in SIST EN 50525-2-71:2011 from the previous edition?

SIST EN 50525-2-71:2011 supersedes Clause 2 of HD 21.5 S3:1994 + A1:1999 + A2:2001.

Which standards are used with SIST EN 50525-2-71:2011?

SIST EN 50525-2-71:2011 depends on several referenced documents for materials and test methods:

  • EN 50525-1 - Gives the general requirements and the common terms and definitions.
  • EN 50363-3 - Specifies PVC insulating compounds, including Type TI 2.
  • EN 50395 - Provides electrical test methods used for conductor resistance, voltage test and insulation resistance.
  • EN 50396 - Provides non-electrical test methods used for dimensional checks and mechanical tests.
  • EN 60332-1-2 - Gives the fire test for vertical flame propagation on a single insulated wire or cable.
  • EN 60811-1-4 - Gives low-temperature test methods, including the impact test at - 5 °C.
  • HD 516 - Gives guidance on safe use of the cables covered by this standard.

What does the SIST EN 50525-2-71:2011 document contain?

SIST EN 50525-2-71:2011 contains the construction description for H03VH-Y, the requirement list, and the test regime needed to verify the cable. Annex A brings the test plan together in a table, including the test methods and the referenced clauses in the test standards.

Annex B provides general data for Type H03VH-Y, including insulation thickness, mean overall dimensions, minimum insulation resistance at 70 °C, and maximum conductor resistance at 20 °C. Annex C gives the procedures for the mechanical tests on completed cables, including the bending and snatch tests used to check durability in use.

Relations

Effective Date
28-Jan-2023
Effective Date
28-Jan-2023
Effective Date
28-Jan-2023
Effective Date
09-Feb-2026
Effective Date
09-Feb-2026
Effective Date
09-Feb-2026
Effective Date
09-Feb-2026
Effective Date
09-Feb-2026
Effective Date
03-Feb-2026
Effective Date
07-Jun-2022
Effective Date
07-Jun-2022
Effective Date
07-Jun-2022
Effective Date
06-Jan-2009
Effective Date
06-Jan-2009
Effective Date
06-Jan-2009

Buy Documents

Standard

SIST EN 50525-2-71:2011

English language (9 pages)
Preview
Preview
e-Library read for
×1 day

Get Certified

Connect with accredited certification bodies for this standard

IMQ S.p.A. (Certification)

Italian electrical product certification.

ACCREDIA Italy Verified

SLG Prüf- und Zertifizierungs GmbH

German testing and certification body.

DAKKS Germany Verified

UL Solutions

Global safety science company with testing, inspection and certification.

ANAB United States Verified

Sponsored listings

Frequently Asked Questions

SIST EN 50525-2-71:2011 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-71: Cables for general applications - Flat tinsel cables (cords) with thermoplastic PVC insulation". This standard covers: This European Standard applies to thermoplastic (PVC) insulated flexible flat tinsel flexible cables. The cables are of rated voltage U0/U 300/300 V. The cables are intended for the connection of small appliances to the fixed supply. The maximum conductor operating temperature for the cable in this standard is 40 °C. NOTE HD 516 contains extensive guidance on the safe use of cables in this standard. This EN 50525-2-71 should be read in conjunction with EN 50525-1, which specifies general requirements.

This European Standard applies to thermoplastic (PVC) insulated flexible flat tinsel flexible cables. The cables are of rated voltage U0/U 300/300 V. The cables are intended for the connection of small appliances to the fixed supply. The maximum conductor operating temperature for the cable in this standard is 40 °C. NOTE HD 516 contains extensive guidance on the safe use of cables in this standard. This EN 50525-2-71 should be read in conjunction with EN 50525-1, which specifies general requirements.

SIST EN 50525-2-71:2011 is classified under the following ICS (International Classification for Standards) categories: 29.060.20 - Cables. The ICS classification helps identify the subject area and facilitates finding related standards.

SIST EN 50525-2-71:2011 has the following relationships with other standards: It is inter standard links to SIST HD 21.5 S3:1998/A2:2002, SIST HD 21.5 S3:1998/A1:2000, SIST HD 21.5 S3:1998, SIST EN 1648-1:2018, SIST EN 16282-2:2017, SIST EN 16282-3:2017, SIST EN 16282-3:2017+A1:2021, SIST EN 1648-2:2018, SIST EN 60335-1:2012/A13:2017, SIST HD 21.5 S3:1998/A1:2000, SIST HD 21.5 S3:1998/A2:2002, SIST HD 21.5 S3:1998, SIST HD 21.5 S3:1998/A1:2000, SIST HD 21.5 S3:1998/A2:2002, SIST HD 21.5 S3:1998. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

SIST EN 50525-2-71:2011 is associated with the following European legislation: EU Directives/Regulations: 2006/95/EC, 2014/35/EU. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

SIST EN 50525-2-71:2011 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


SLOVENSKI STANDARD
01-september-2011
(OHNWULþQLNDEOL1L]NRQDSHWRVWQLHQHUJHWVNLNDEOL]QD]LYQRQDSHWRVWMRGR
YNOMXþQR9 88 GHO.DEOL]DVSORãQRXSRUDER3ORãþDWHRSOHWHQH
QLWLVWHUPRSODVWLþQR39&L]RODFLMR
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750
V (U0/U) - Part 2-71: Cables for general applications - Flat tinsel cables (cords) with
thermoplastic PVC insulation
Kabel und Leitungen - Starkstromleitungen mit Nennspannungen bis 450/750 V (U0/U) -
Teil 2-71: Starkstromleitungen für allgemeine Anwendungen - Lahnlitzen-Leitungen mit
thermoplastischer PVCIsolierung
Câbles électriques - Câbles d’énergie basse tension de tension assignée au plus égale à
450/750 V (U0/U) - Partie 2-71: Câbles pour applications générales - Câbles plats pour
cordons à fil rosette, isolés en PVC thermoplastique
Ta slovenski standard je istoveten z: EN 50525-2-71:2011
ICS:
29.060.20 Kabli Cables
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD
EN 50525-2-71
NORME EUROPÉENNE
May 2011
EUROPÄISCHE NORM
ICS 29.060.20 Supersedes HD 21.5 S3:1994 (partially) + A1:1999 (partially) + A2:2001 (partially)

English version
Electric cables -
Low voltage energy cables of rated voltages up to and including 450/750 V
(U /U) -
Part 2-71: Cables for general applications -
Flat tinsel cables (cords) with thermoplastic PVC insulation

Câbles électriques -  Kabel und Leitungen -
Câbles d’énergie basse tension de tension Starkstromleitungen mit Nennspannungen
assignée au plus égale à 450/750 V bis 450/750 V (U /U) -
(U /U) -
Teil 2-71: Starkstromleitungen für
Partie 2-71: Câbles pour applications allgemeine Anwendungen -
générales - Lahnlitzen-Leitungen mit
Câbles plats pour cordons à fil rosette, thermoplastischer PVC-Isolierung
isolés en PVC thermoplastique
This European Standard was approved by CENELEC on 2011-01-17. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy,
Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia,
Spain, Sweden, Switzerland and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Management Centre: Avenue Marnix 17, B - 1000 Brussels

© 2011 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 50525-2-71:2011 E
Foreword
This European Standard was prepared by the Technical Committee CENELEC TC 20, Electric
cables.
The text of the draft was submitted to the formal vote and was approved by CENELEC as
EN 50525-2-71 on 2011-01-17.
This document, which is one of a multipart series, supersedes Clause 2 of HD 21.5 S3:1994 +
A1:1999 + A2:2001.
Attention is drawn to the possibility that some of the elements of this document may be the
subject of patent rights. CEN and CENELEC shall not be held responsible for identifying any
or all such patent rights.
The following dates were fixed:

– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2012-01-17

– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2014-01-17
_____________
- 3 - EN 50525-2-71:2011
Contents
Page
1 Scope . 4
2 Normative references . 4
3 Terms and definitions . 4
4 Flexible cables – H03VH-Y . 4
4.1 Construction . 4
4.2 Requirements . 5
Annex A (normative) Tests for cables to EN 50525-2-71 . 6
Annex B (normative) General data . 7
Annex C (normative) Requirements for mechanical tests on completed cables . 8
C.1 Bending test . 8
C.2 Snatch test. 8
Bibliography . 9

Tables
Table A.1 . 6
Table B.1
...