Status
Not Published
Public Enquiry End Date
31-Oct-2026
Current Stage
4020 - Public enquire (PE) (Adopted Project)
Start Date
31-Aug-2026
Due Date
18-Jan-2027

Buy Documents

Draft

SIST EN 55016-1-6:2015/prA3 (Frag 4):2026 - BARVE

English language (10 pages)
Preview
Preview
e-Library read for
×1 day

SIST EN 55016-1-6:2015/prA3 (Frag 4):2026 is the Slovenian adoption of an IEC/CISPR amendment fragment published by SIST. It updates CISPR 16-1-6 for EMC-antenna calibration, with this fragment focused on NSA-related changes to Annex C for correction factors, biconical antenna geometry, and uncertainty analysis. It is relevant to people who perform or review radio-disturbance and immunity measurements, especially EMC measurement laboratories and standards committees.

What does SIST EN 55016-1-6:2015/prA3 (Frag 4):2026 specify?

SIST EN 55016-1-6:2015/prA3 (Frag 4):2026 is an amendment fragment to Part 1-6 of the specification for radio disturbance and immunity measuring apparatus and methods. It addresses EMC-antenna calibration, and the edited text in this fragment updates material in Annex C and adds supplemental comparison content.

The document is organized as a foreword, an introduction, normative Annex C, and supplemental content for information only. Annex C is the part that carries the technical rationale and uncertainty-related antenna information used in practice.

PartWhat it covers
Annex CRationale for the equations used in antenna calibration and antenna characteristics for uncertainty analysis in the frequency range 30 MHz to 1 GHz
Supplemental contentComparison figures and tables for correction factors, including comparisons with CISPR 16-1-6:2022 and with other biconical antennas

What are the key requirements of SIST EN 55016-1-6:2015/prA3 (Frag 4):2026?

Annex C is the technical core of the fragment. It gives the rationale for antenna-calibration equations and the information needed for uncertainty analysis, so users can justify how they correct and evaluate antenna measurements in the 30 MHz to 1 GHz range.

Updated correction factors

In C.6.2, the document replaces entries in Table C.2 with revised correction factors ΔF for converting antenna factor measured by SSM to F_a,SSM. The values are given for 50 Ω and 200 Ω baluns across the stated frequency range. In practice, a lab uses these values when it corrects measured antenna data, so the chosen balun and frequency point must match the setup.

Revised biconical antenna figures and dimensions

The fragment replaces the text linked to Figure C.10, adds Figure C.18, and replaces Table C.3. Figure C.10 shows one triangular section of a biconical antenna element, while Figure C.18 shows the complete biconical antenna. Table C.3 gives the mechanical dimensions, including lengths, radii, and the number of segments. In practice, these items matter when building, checking, or modeling the antenna used for calibration.

Uncertainty analysis support

Annex C.6 deals with uncertainty contribution due to ground plane reflection. That matters because antenna measurements over a ground plane can shift the result, so the document gives the background needed to include that effect in an uncertainty budget.

Comparison material for application review

The supplemental content compares the correction factors in this fragment with CISPR 16-1-6:2022 and with other typical biconical antennas. It also compares 1 MHz and 5 MHz frequency steps and states that the 4:1 balun is preferred over the 1:1 balun because frequency variation is smaller. In practice, this helps users choose the measurement arrangement that gives steadier correction factors.

What terms does SIST EN 55016-1-6:2015/prA3 (Frag 4):2026 define?

  • International Electrotechnical Commission (IEC) - The international body that publishes the publication family this amendment belongs to.
  • International Special Committee on Radio Interference (CISPR) - The IEC committee responsible for radio-interference measurement work and this amendment family.
  • Committee Draft for Vote (CDV) - A draft stage used for committee voting before publication.
  • Electromagnetic Compatibility (EMC) - The technical field concerned with emission and immunity behavior of equipment.
  • Biconical antenna - The antenna type whose diagram and mechanical dimensions are revised in Annex C.
  • Balun - The matching arrangement named in the tables and figures for the biconical antenna setup.

Who uses SIST EN 55016-1-6:2015/prA3 (Frag 4):2026?

SIST EN 55016-1-6:2015/prA3 (Frag 4):2026 is used by EMC engineers, antenna calibration laboratories, radio-disturbance test houses, and people preparing uncertainty budgets for measurement systems. It is also relevant to standards committees working on horizontal EMC topics, because the front matter lists CIS/B, CIS/D, CIS/F, CIS/H, and CIS/I as interested committees. Buyers and quality managers can use it to check whether a lab’s antenna calibration practice matches the updated CISPR 16-1-6 material.

What changed in SIST EN 55016-1-6:2015/prA3 (Frag 4):2026 from the previous edition?

The supplemental content compares this fragment with CISPR 16-1-6:2022 and shows small differences in correction factors. The amendment also revises Figure C.10 and Table C.3, updates Table C.2, and adds Figure C.18.

Which standards are used with SIST EN 55016-1-6:2015/prA3 (Frag 4):2026?

This fragment belongs to CISPR 16-1-6 Amendment 3 and is identified as Fragment 4: NSA. The text says the combined fragments of Amendment 3 are to be published as CISPR 16-1-6 ED2. The Slovenian page also states that this standard is identical to EN 55016-1-6:2015/prA3 (Frag 4):2026.

What does the SIST EN 55016-1-6:2015/prA3 (Frag 4):2026 document contain?

The document contains the updated wording for Annex C, including the revised ground-plane-reflection section, the updated correction-factor table, and the new and replaced antenna figures. It also contains supplemental comparison figures and a table that show how the correction factors differ from CISPR 16-1-6:2022 and from other biconical antenna cases. The included material is used for calibration work, construction checks, and uncertainty analysis rather than for a general overview of EMC measurement.

Relations

Effective Date
16-May-2023

Buy Documents

Draft

SIST EN 55016-1-6:2015/prA3 (Frag 4):2026 - BARVE

English language (10 pages)
Preview
Preview
e-Library read for
×1 day

Get Certified

Connect with accredited certification bodies for this standard

ANCE

Mexican certification and testing association.

EMA Mexico Verified

BSMI (Bureau of Standards, Metrology and Inspection)

Taiwan's standards and inspection authority.

TAF Taiwan Verified

Intertek Slovenia

Intertek testing, inspection, and certification services in Slovenia.

UKAS Slovenia Verified

Sponsored listings

Frequently Asked Questions

SIST EN 55016-1-6:2015/prA3 (Frag 4):2026 is a draft published by the Slovenian Institute for Standardization (SIST). Its full title is "Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-6: Radio disturbance and immunity measuring apparatus - EMC-antenna calibration - Amendment 3 - Fragment 4: NSA". This standard covers: Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-6: Radio disturbance and immunity measuring apparatus - EMC-antenna calibration - Amendment 3 - Fragment 4: NSA

Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-6: Radio disturbance and immunity measuring apparatus - EMC-antenna calibration - Amendment 3 - Fragment 4: NSA

SIST EN 55016-1-6:2015/prA3 (Frag 4):2026 is classified under the following ICS (International Classification for Standards) categories: 17.220.20 - Measurement of electrical and magnetic quantities; 33.100.10 - Emission; 33.100.20 - Immunity. The ICS classification helps identify the subject area and facilitates finding related standards.

SIST EN 55016-1-6:2015/prA3 (Frag 4):2026 has the following relationships with other standards: It is inter standard links to SIST EN 55016-1-6:2015. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

SIST EN 55016-1-6:2015/prA3 (Frag 4):2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


SLOVENSKI STANDARD
01-oktober-2026
Specifikacija za merilne naprave in metode za merjenje radijskih motenj in
odpornosti - 1-6. del: Merilne naprave za merjenje radijskih motenj in odpornosti -
Umerjanje EMC antene - Dopolnilo 3 - Fragment 4: NSA
Specification for radio disturbance and immunity measuring apparatus and methods -
Part 1-6: Radio disturbance and immunity measuring apparatus - EMC-antenna
calibration - Amendment 3 - Fragment 4: NSA
Ta slovenski standard je istoveten z: EN 55016-1-6:2015/prA3 (Frag 4):2026
ICS:
17.220.20 Merjenje električnih in Measurement of electrical
magnetnih veličin and magnetic quantities
33.100.20 Imunost Immunity
SIST EN 55016-1-6:2015/prA3 (Frag en
4):2026
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

CIS/A/1514/CDV
COMMITTEE DRAFT FOR VOTE (CDV)
PROJECT NUMBER:
CISPR 16-1-6/AMD3/FRAG4 ED1
DATE OF CIRCULATION: CLOSING DATE FOR VOTING:
2026-08-21 2026-11-13
SUPERSEDES DOCUMENTS:
CIS/A/1406/CD, CIS/A/1425/CC
IEC CIS/A : RADIO-INTERFERENCE MEASUREMENTS AND STATISTICAL METHODS
SECRETARIAT: SECRETARY:
United States of America Mr Nicholas Abbondante
OF INTEREST TO THE FOLLOWING COMMITTEES: HORIZONTAL FUNCTION(S):
CIS/B,CIS/D,CIS/F,CIS/H,CIS/I CISPR/CIS/A Horizontal Basic EMC
ASPECTS CONCERNED:
Electromagnetic Compatibility
SUBMITTED FOR CENELEC PARALLEL VOTING NOT SUBMITTED FOR CENELEC PARALLEL VOTING
Attention IEC-CENELEC parallel voting
The attention of IEC National Committees, members of
CENELEC, is drawn to the fact that this Committee Draft
for Vote (CDV) is submitted for parallel voting.
The CENELEC members are invited to vote through the
CENELEC online voting system.
This document is still under study and subject to change. It should not be used for reference purposes.
Recipients of this document are invited to submit, with their comments, notification of any relevant patent rights of which
they are aware and to provide supporting documentation.
Recipients of this document are invited to submit, with their comments, notification of any relevant “In Some Countries”
clauses to be included should this proposal proceed. Recipients are reminded that the CDV stage is the final stage for
submitting ISC clauses. (SEE AC/22/2007 OR NEW GUIDANCE DOC).

TITLE:
Amendment 3 - Fragment 4: NSA
PROPOSED STABILITY DATE: 2027
NOTE FROM TC/SC OFFICERS:
This CDV contains the edited text of CISPR 16-1-6 Ed1 AMD3 fragment 4 "NSA"
electronic file, to make a copy and to print out the content for the sole purpose of preparing National Committee positions.
You may not copy or "mirror" the file or printed version of the document, or any part of it, for any other purpose without
permission in writing from IEC.

CISPR CDV 16-1-6/AMD3/FRAG4 © IEC 2026
1 INTERNATIONAL ELECTROTECHNICAL COMMISSION
2 INTERNATIONAL SPECIAL COMMITTEE ON RADIO INTERFERENCE
3 ____________
5 SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY
6 MEASURING APPARATUS AND METHODS –
8 Part 1-6: Radio disturbance and immunity measuring apparatus –
9 EMC antenna calibration
11 AMENDMENT 3 – FRAGMENT 4: NSA
13 FOREWORD
14 1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
15 all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international
16 co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and
17 in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports,
18 Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their
19 preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with
20 may participate in this preparatory work. International, governmental and non-governmental organizations liaising
21 with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for
22 Standardization (ISO) in accordance with conditions determined by agreement between the two organizations.
23 2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
24 consensus of opinion on the relevant subjects since each technical committee has representation from all
25 interested IEC National Committees.
26 3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
27 Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
28 Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
29 misinterpretation by any end user.
30 4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
31 transparently to the maximum extent possible in their national and regional publications. Any divergence between
32 any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter.
33 5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
34 assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
35 services carried out by independent certification bodies.
36 6) All users should ensure that they have the latest edition of this publication.
37 7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
38 members of its technical committees and IEC National Committees for any personal injury, property damage or
39 other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
40 expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
41 Publications.
42 8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
43 indispensable for the correct application of this publication.
44 9) IEC draws attention to the possibility that the implementation of this document may involve the use of (a)
45 patent(s). IEC takes no position concerning the evidence, validity or applicability of any claimed patent rights in
46 respect thereof. As of the date of publication of this document, IEC has not received notice of (a) patent(s), which
47 may be required to implement this document. However, implementers are cautioned that this may not represent
48 the latest information, which may be obtained from the patent database available at https://patents.iec.ch. IEC
49 shall not be held responsible for identifying any or all such patent rights.
50 Amendment 3 to CISPR 16-1-6 has been prepared by CISPR subcommittee A: Radio-
51 interference measurements and statistical methods.
CISPR CDV 16-1-6/AMD3/FRAG4 © IEC 2026
55 The text of this Amendment is based on the following documents:
Draft Report on voting
XX/XX/XXXX XX/XX/XXX
57 Full information on the voting for its approval can be found in the report on voting indicated in
58 the above table.
59 The language used for the development of this Amendment is English.
60 This document was drafted in accordance with ISO/IEC Directives, Part 2, and developed in
61 accordance with ISO/IEC Directives, Part 1 and ISO/IEC Directives, IEC Supplement, available
62 at www.iec.ch/members_experts/refdocs. The main document types developed by IEC are
63 described in greater detail at www.iec.ch/publications/.
64 The committee has decided that the contents of this document will remain unchanged until the
65 stability date indicated on the IEC website under webstore.iec.ch in the data related to the
66 specific document. At this date, the document will be
67 • reconfirmed,
68 • withdrawn, or
69 • revised.
70 ____________
72 Introduction
73 (not to be included at publication)
74 Proposed revision of CIS
...