IEC 62037-8:2022 defines a radiated passive intermodulation (PIM) test to determine PIM levels generated by a device or object when it is exposed to RF radiation. This test can be conducted on any material or object and is not limited to devices designed to propagate RF signals. This test can be conducted as either a near field or far field test as defined by the test specification in an outdoor test site or in an anechoic test chamber.

  • Standard
    22 pages
    English and French language
    sale 15% off

IEC 62037-7:2022 defines test methods for reverse measurement of passive intermodulation (PIM) in systems of RF components deployed in the field. Field PIM measurements can be conducted on RF systems terminated into low PIM loads or on antenna feed systems that broadcast the test signals into the environment.

  • Standard
    22 pages
    English and French language
    sale 15% off

IEC 62037-6:2021 is available as IEC 62037-6:2021 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 62037-6:2021 defines the test fixtures and procedures recommended for measuring levels of passive intermodulation generated by antennas, typically used in wireless communication systems. The purpose is to define qualification and acceptance test methods for antennas for use in low intermodulation (low IM) applications. This second edition cancels and replaces the first edition published in 2013. This edition includes the following significant technical changes with respect to the previous edition:
a. dynamic testing requirements updated to define impact energy and locations to apply impacts to devices under test

  • Standard
    31 pages
    English and French language
    sale 15% off

IEC 62037-5:2021 is available as IEC 62037-5:2021 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 62037-5:2021 defines test fixtures and procedures recommended for measuring levels of passive intermodulation generated by filters, typically used in wireless communication systems. The purpose is to define qualification and acceptance test methods for filters for use in low intermodulation (low IM) applications. This second edition cancels and replaces the first edition published in 2013. This edition includes the following significant technical changes with respect to the previous edition:
a. dynamic testing requirements updated to define impact energy and locations to apply impacts to devices under test.

  • Standard
    25 pages
    English and French language
    sale 15% off

IEC 62037-1:2021 is available as IEC 62037-1:2021 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 62037-1:2021 deals with the general requirements and measuring methods for intermodulation (IM) level measurement of passive RF and microwave components, which can be caused by the presence of two or more transmitting signals. The test procedures given in this document give the general requirements and measurement methods required to characterize the level of unwanted IM signals using two transmitting signals. The IEC 62037 series addresses the measurement of PIM, but does not cover the long-term reliability of a product with reference to its performance. This second edition cancels and replaces the first edition published in 2012. This edition includes the following significant technical changes with respect to the previous edition:
a. clarification added that test equipment may utilize pulsed generators to reduce power consumption;
b. heating effect differences in the device under test noted in Annex B for tests conducted using pulsed generators;
c. guidance added in Annex B to improve probability of detection of short duration PIM events while dynamic testing.

  • Standard
    29 pages
    English and French language
    sale 15% off

IEC 62037-3:2021 is available as IEC 62037-3:2021 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 62037-3:2021 defines the impact test on coaxial connectors to evaluate their robustness against weak connections and particles inside the connector, as independently as possible from the effects of cable PIM (passive intermodulation). For other connectors (e.g. panel mounted connectors), the cable can be replaced by an adequate transmission-line (e.g. airline, stripline). In order to evaluate the effects of mechanical stresses on the connectors, a series of impacts is applied to the connectors while measuring the PIM. This second edition cancels and replaces the first edition published in 2012. This edition includes the following significant technical changes with respect to the previous edition:
a. impact method changed to utilize a steel ball rather than a brass rod;
b. impact energy required to test each connector type added;
c. method added to calculate impact energy for connector types not listed in the document.

  • Standard
    17 pages
    English and French language
    sale 15% off

IEC 62037-2:2021 defines a procedure to measure levels of passive intermodulation generated by a coaxial cable assembly. This test method is applicable to jumper cables, i.e. cable assemblies intended to provide interface flexibility between rigid devices. It is also used to evaluate cable assemblies that are subjected to motion in operation.
This second edition cancels and replaces the first edition published in 2012. This edition includes the following significant technical changes with respect to the previous edition:
a. criteria for application of mechanical stress revised to be a function of advertised cable bend radius.

  • Standard
    16 pages
    English and French language
    sale 15% off

IEC 62037-6:2013 defines test fixtures and procedures recommended for measuring levels of passive intermodulation generated by antennas, typically used in wireless communication systems. The purpose is to define qualification and acceptance test methods for antennas for use in low intermodulation (low IM) applications.

  • Standard
    26 pages
    English and French language
    sale 15% off

IEC 62037-5:2013 defines test fixtures and procedures recommended for measuring levels of passive intermodulation generated by filters, typically used in wireless communication systems. The purpose is to define qualification and acceptance test methods for filters for use in low intermodulation (low IM) applications.

  • Standard
    24 pages
    English and French language
    sale 15% off

IEC 62037-2:2012 defines a procedure to measure levels of passive intermodulation generated by a coaxial cable assembly. This test method is applicable to jumper cables, i.e. cable assemblies intended to provide interface flexibility between rigid devices.

  • Standard
    13 pages
    English and French language
    sale 15% off

IEC 62037-4:2012 is part of the IEC 62037 series, and defines test fixtures and procedures recommended for measuring levels of passive intermodulation generated by coaxial cables. Two dynamic test methods and a static test method are defined.

  • Standard
    19 pages
    English and French language
    sale 15% off

IEC 62037-3:2012 is part of the IEC 62037 series, and defines the impact test on coaxial connectors to evaluate their robustness against weak connections and particles inside the connector as independently as possible from the effects of cable PIM (passive intermodulation).

  • Standard
    16 pages
    English and French language
    sale 15% off

IEC 62037-1:2012 is applicable to the general requirements and measuring methods for intermodulation (IM) level measurement of passive RF and microwave components, which can be caused by the presence of two or more transmitting signals. This first edition of IEC 62037-1 replaces IEC 62037, published in 1999. It constitutes a technical revision. This standard is part of the IEC 62037 series which addresses the measurement of PIM, but does not cover the long term reliability of a product with reference to its performance. This standard is to be used in conjunction with other appropriate part(s) of IEC 62037.

  • Standard
    33 pages
    English and French language
    sale 15% off