Standard Specification for Figure-9 Deep-Grooved and Figure-8 Copper Trolley Wire for Industrial Haulage

ABSTRACT
This specification deals with figure-9 deep-section grooved and figure-8 copper trolley wire for use in industrial haulage. The material shall conform to the required tensile properties: tensile strength and elongation. Tension tests shall be made. However, elongation tests shall not be made on specimens containing joints. The electrical resistivity shall be determined by resistance measurements. The standard sizes of figure-9 deep-section grooved and figure-8 copper trolley wire are specified.
SCOPE
1.1 This specification covers figure-9 deep-section grooved and figure-8 copper trolley wire for use in industrial haulage (Explanatory Note 1).  
1.2 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.  
1.3 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

General Information

Status
Published
Publication Date
31-Mar-2017
Technical Committee
B01 - Electrical Conductors

Relations

Effective Date
01-Apr-2017
Effective Date
15-Apr-2020
Effective Date
01-Apr-2017
Effective Date
01-Apr-2017
Effective Date
01-Apr-2017
Effective Date
01-Apr-2017
Effective Date
01-Apr-2016
Effective Date
01-Apr-2016
Effective Date
15-Sep-2015
Effective Date
01-May-2015
Effective Date
01-Apr-2014
Effective Date
15-Oct-2012
Effective Date
15-Oct-2012
Effective Date
01-Oct-2010
Effective Date
01-Nov-2009

Overview

ASTM B116-95(2017) is the international standard specification for figure-9 deep-grooved and figure-8 copper trolley wire, primarily designed for industrial haulage applications. Developed by ASTM International, this standard outlines the requirements for mechanical and electrical properties, delivery conditions, and standard sizes for copper trolley wire utilized in industrial environments. Complying with ASTM B116 ensures optimal performance, durability, and safety in haulage systems that use copper trolley wires for power transmission.

Key Topics

  • Types of Trolley Wire: This standard applies to both figure-9 deep-grooved and figure-8 copper trolley wires, each serving distinct roles in industrial haulage, particularly with trolley wheels and grooved collectors.
  • Material Requirements: Only high-quality, pure copper is permitted, ensuring that finished products meet established performance and reliability standards. Materials must conform to ASTM B49 or other agreed-upon specifications.
  • Mechanical Properties: The standard specifies tensile strength and elongation requirements, with mandatory tension testing on samples. Elongation tests are not performed on samples with joints. The wire must meet minimum mechanical properties to guarantee long-term integrity in industrial settings.
  • Electrical Resistivity: ASTM B116 mandates that the electrical resistivity of the copper wire be tested according to ASTM B193, ensuring efficient conductivity critical for trolley applications.
  • Dimensions and Sizes: Nominal cross-sectional area, expressed in circular mils, defines standard wire sizes. Permissible variations in weight and dimensional tolerances are included to aid quality control.
  • Inspection and Quality Assurance: Comprehensive procedures for sampling, inspection, and rejection support consistent quality. All tests must align with the specified requirements and can be conducted at the manufacturing site.
  • Packaging and Marking: Detailed guidelines ensure secure packaging, correct package labeling, and protective shipment practices to maintain wire quality upon delivery.

Applications

ASTM B116-95(2017) is widely implemented wherever reliable copper trolley wire is vital for industrial haulage power systems. Typical applications include:

  • Industrial Rail Haulage: Used to transmit power to vehicles like mine locomotives, cranes, and automated guided vehicles in factories and warehouses.
  • Material Handling Systems: Essential for electrified railways, conveyor systems, and overhead trolley lines in manufacturing plants.
  • Mining Operations: Figure-8 and figure-9 trolley wires are standard for powering equipment in underground and surface mining, where durability and conductivity are critical.
  • Specialized Industrial Environments: Any setting requiring dependable electrical conductor systems for moving equipment, such as steel mills or ports.

Using copper trolley wire that conforms to ASTM B116 assures users of reliable performance, minimized electrical losses, and reduced maintenance costs over the equipment’s service life.

Related Standards

For organizations seeking broader or more specific guidance on conductor materials and performance, several related standards complement ASTM B116:

  • ASTM B9: Specification for Bronze Trolley Wire - relevant for applications requiring bronze conductors.
  • ASTM B47: Specification for Copper Trolley Wire - covers general copper trolley wire designs and uses.
  • ASTM B49: Specification for Copper Rod for Electrical Purposes - defines base material requirements for trolley wire production.
  • ASTM B193: Test Method for Resistivity of Electrical Conductor Materials - provides the test protocols for evaluating copper wire conductivity.

By referencing ASTM B116-95(2017) along with these associated standards, manufacturers, engineers, and procurement specialists ensure the correct and safe selection of copper trolley wire for industrial haulage and related electrical applications. This not only fulfills technical requirements but also supports compliance with global best practices and recognized international standards.

Buy Documents

Technical specification

ASTM B116-95(2017) - Standard Specification for Figure-9 Deep-Grooved and Figure-8 Copper Trolley Wire for Industrial Haulage

English language (5 pages)
sale 15% off
sale 15% off

Get Certified

Connect with accredited certification bodies for this standard

IMQ S.p.A. (Certification)

Italian electrical product certification.

ACCREDIA Italy Verified

SLG Prüf- und Zertifizierungs GmbH

German testing and certification body.

DAKKS Germany Verified

UL Solutions

Global safety science company with testing, inspection and certification.

ANAB United States Verified

Sponsored listings

Frequently Asked Questions

ASTM B116-95(2017) is a technical specification published by ASTM International. Its full title is "Standard Specification for Figure-9 Deep-Grooved and Figure-8 Copper Trolley Wire for Industrial Haulage". This standard covers: ABSTRACT This specification deals with figure-9 deep-section grooved and figure-8 copper trolley wire for use in industrial haulage. The material shall conform to the required tensile properties: tensile strength and elongation. Tension tests shall be made. However, elongation tests shall not be made on specimens containing joints. The electrical resistivity shall be determined by resistance measurements. The standard sizes of figure-9 deep-section grooved and figure-8 copper trolley wire are specified. SCOPE 1.1 This specification covers figure-9 deep-section grooved and figure-8 copper trolley wire for use in industrial haulage (Explanatory Note 1). 1.2 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only. 1.3 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

ABSTRACT This specification deals with figure-9 deep-section grooved and figure-8 copper trolley wire for use in industrial haulage. The material shall conform to the required tensile properties: tensile strength and elongation. Tension tests shall be made. However, elongation tests shall not be made on specimens containing joints. The electrical resistivity shall be determined by resistance measurements. The standard sizes of figure-9 deep-section grooved and figure-8 copper trolley wire are specified. SCOPE 1.1 This specification covers figure-9 deep-section grooved and figure-8 copper trolley wire for use in industrial haulage (Explanatory Note 1). 1.2 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only. 1.3 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

ASTM B116-95(2017) is classified under the following ICS (International Classification for Standards) categories: 29.060.10 - Wires; 29.280 - Electric traction equipment. The ICS classification helps identify the subject area and facilitates finding related standards.

ASTM B116-95(2017) has the following relationships with other standards: It is inter standard links to ASTM B116-95(2012), ASTM B49-20, ASTM B9-76(2017)e1, ASTM B49-17, ASTM B47-95a(2017), ASTM B9-76(2017), ASTM B193-16, ASTM B49-16, ASTM B49-15a, ASTM B49-15, ASTM B193-02(2014), ASTM B9-90(2012), ASTM B47-95a(2012), ASTM B49-10, ASTM B49-09. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

ASTM B116-95(2017) is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Designation: B116 −95 (Reapproved 2017)
Standard Specification for
Figure-9 Deep-Grooved and Figure-8 Copper Trolley Wire for
Industrial Haulage
This standard is issued under the fixed designation B116; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope 3.1.7 Relation between vertical axis of grooved wire and
axis of reel (see 14.1),
1.1 This specification covers figure-9 deep-section grooved
3.1.8 Size of arbor hole if other than for a 2 ⁄2-in. (64-mm)
and figure-8 copper trolley wire for use in industrial haulage
shaft (see 14.2),
(Explanatory Note 1).
3.1.9 Special package marking, if required (see 14.4), and
1.2 The values stated in inch-pound units are to be regarded
3.1.10 Place of inspection (Section 12).
as the standard. The values given in parentheses are for
information only.
4. Materials and Manufacturer
1.3 This international standard was developed in accor-
4.1 The material shall be copper of such quality and purity
dance with internationally recognized principles on standard-
that the finished product shall have the properties and charac-
ization established in the Decision on Principles for the
teristics prescribed in this specification.
Development of International Standards, Guides and Recom-
NOTE 1—Specification B49 defines the materials suitable for use.
mendations issued by the World Trade Organization Technical
4.2 Copper bars of special qualities, forms, or types, as may
Barriers to Trade (TBT) Committee.
be agreed upon between the manufacturer and the purchaser,
2. Referenced Documents
and that will conform to the requirements prescribed in this
specification may also be used.
2.1 ASTM Standards:
B9 Specification for Bronze Trolley Wire
5. Tensile Properties
B47 Specification for Copper Trolley Wire
5.1 Figure-8 wire shall conform to the requirements as to
B49 Specification for Copper Rod for Electrical Purposes
tensile properties specified in Table 1.
B193 Test Method for Resistivity of Electrical Conductor
Materials
5.2 Figure-9 deep-section grooved wire shall conform to the
requirements as to tensile properties specified in Table 2.
3. Ordering Information
5.3 Tests on a specimen of wire containing a joint shall
3.1 Orders for material under this specification shall include
show at least 95 % of the tensile strength specified in Table 1
the following information:
or Table 2, as may be applicable. Elongation tests shall not be
3.1.1 Quantity of each size and section,
made on specimens containing joints.
3.1.2 Wire size: circular-mil area (Section 6, Fig. 1 or Fig.
5.4 Tension tests shall be made on representative samples.
2),
The elongation shall be determined as the permanent increase
3.1.3 Shape of section (Section 1),
in length, due to the breaking of the wire in tension, measured
3.1.4 Type of copper, if special (Section 4),
between gage marks placed originally 10 in. apart upon the test
3.1.5 Package size (see 14.3),
specimen (Explanatory Note 1). The fracture shall be between
3.1.6 Lagging, if required (see 14.1),
the gage marks and not closer than 1 in. (25 mm) to either gage
mark.
This specification is under the jurisdiction of ASTM Committee B01 on
5.5 The twist test shall be omitted.
Electrical Conductors and is the direct responsibility of Subcommittee B01.04 on
Conductors of Copper and Copper Alloys.
Current edition approved April 1, 2017. Published April 2017. Originally 6. Sections
approved in 1939. Last previous edition approved in 2012 as B116 – 95 (2012).
6.1 Standard sections of figure-8 trolley wire shall be those
DOI: 10.1520/B0116-95R17.
For referenced ASTM standards, visit the ASTM website, www.astm.org, or shown in Fig. 1.
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
6.2 Standard sections of figure-9 deep-section grooved trol-
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website. ley wire shall be those shown in Fig. 2.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
B116 − 95 (2017)
FIG. 1 Standard Sections Figure-8 Trolley Wire
FIG. 2 Standard Sections Figure-9 Deep-Section Grooved Trolley Wire
B116 − 95 (2017)
TABLE 1 Tensile Requirements for Figure-8 Wire
accordance with the best commercial practice, and shall be
Tensile Elongation capable of meeting the tensile strength requirements in 5.3.
Nominal Area,
Strength, in 10 in.,
cmils
min, psi min, %
11. Workmanship, Finish, and Appearance
350 000 42 800 4.50
211 600 46 600 3.75
11.1 The wire shall be of uniform size, shape, and quality
167 800 48 500 3.25
throughout, and shall be free from all scale, flaws, splits, and
133 100 50 200 2.80
105 600 51 800 2.40
scratches not consistent with the best commercial practice.
12. Inspection
TABLE 2 Tensile Requirements for Figure-9 Wire
12.1 All tests governing the acceptance or rejection of the
Nominal Tensile Elongation
Area, Strength, in 10 in.,
wire, unless otherwise specified, shall be made at the place of
cmils min, psi min %
manufacture with apparatus furnished by the manufacturer and
400 000 41 300 4.50
inthepresenceofthepurchaserorhisrepresentative,whoshall
350 000 42 800 4.50
be furnished a copy of the tests. The manufacturer shall afford
the inspector representing the purchaser all reasonable
7. Dimensions and Permissible Variations
facilities, without charge, to satisfy him as to the reliability of
the results before the wire is delivered. If the purchaser waives
7.1 The size shall be expressed as the nominal area of cross
inspection, and if he so elects at that time, he shall be furnished
section in circular mils.
with a certified copy of tests made by the manufacturer.
7.2 The standard sizes of figure-8 trolley wire shall be as
specified in Fig. 1.
13. Rejection
7.3 The standard sizes of figure-9 deep-section grooved
13.1 Any reel of wire that fails to conform to the require-
trolley wire shall be as specified in Fig. 2.
ments prescribed in this specification may be rejected. Failure
7.4 The weight in pounds per mile in figure-8 and figure-9
of 30 % of the number of reels ready for inspection at one time
trolley wire calculated from the weight of a specimen not less
shall be deemed sufficient cause for rejection of the whole lot.
than 18 in. (457 mm) in length shall not vary more than 65%
from that specified in Fig. 1 and Fig. 2, respectively.
14. Packaging and Package Marking
7.5 Conformance of the trolley wire to the specified dimen-
14.1 All wire shall be shipped on substantial reels, suitable
sionsshallbedeterminedbytakingthemeasurementsshownin
for the weight of the wire handled, and shall be well
...

Questions, Comments and Discussion