Standard Test Method for Determining Automotive Gear Oil Compatibility with Typical Oil Seal Elastomers

SIGNIFICANCE AND USE
5.1 There are several major causes of automotive lubricant-related seal failures. This test method addresses only those failures caused by excessive elastomer hardening, elongation loss, and volume swell and attempts to determine the likelihood that an oil might cause premature sealing system failures in field use. This test method may be used as a requirement of a performance specification, such as Specification D5760 and J2360.  
5.2 Another major cause of seal failure is the formation of carbon, varnish, and sludge-like deposits on the seal lip. The deposit-forming characteristics of automotive gear oils are evaluated in Test Method D5704. That procedure is intended in part to evaluate the potential for oils to cause premature seal failure in field service.
SCOPE
1.1 This test method2 covers the determination of the compatibility of automotive gear oils with specific nitrile, polyacrylate, and fluoroelastomer oil seal materials.  
1.2 Users of this test method should obtain Test Methods D412, D471, and D2240 and become familiar with their use before proceeding with this test method.  
1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

General Information

Status
Historical
Publication Date
30-Jun-2019
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM D5662-19 - Standard Test Method for Determining Automotive Gear Oil Compatibility with Typical Oil Seal Elastomers
English language
7 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
REDLINE ASTM D5662-19 - Standard Test Method for Determining Automotive Gear Oil Compatibility with Typical Oil Seal Elastomers
English language
7 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: D5662 − 19
Standard Test Method for
Determining Automotive Gear Oil Compatibility with Typical
1
Oil Seal Elastomers
This standard is issued under the fixed designation D5662; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope* D2240Test Method for Rubber Property—Durometer Hard-
2 ness
1.1 This test method covers the determination of the
D5704Test Method for Evaluation of the Thermal and
compatibility of automotive gear oils with specific nitrile,
Oxidative Stability of Lubricating Oils Used for Manual
polyacrylate, and fluoroelastomer oil seal materials.
Transmissions and Final Drive Axles
1.2 Users of this test method should obtain Test Methods
D5760Specification for Performance of Manual Transmis-
D412, D471, and D2240 and become familiar with their use
sion Gear Lubricants
before proceeding with this test method.
E29Practice for Using Significant Digits in Test Data to
1.3 The values stated in SI units are to be regarded as Determine Conformance with Specifications
4
standard. No other units of measurement are included in this
2.2 SAE Standard:
standard.
J2360Lubricating Oil, Gear Multipurpose (Metric) Military
1.4 This standard does not purport to address all of the Use
safety concerns, if any, associated with its use. It is the
responsibility of the user of this standard to establish appro- 3. Terminology
priate safety, health, and environmental practices and deter-
3.1 Definitions of Terms Specific to This Standard:
mine the applicability of regulatory limitations prior to use.
3.1.1 dumbbell, n—the specific cut shape (Die C) of an
1.5 This international standard was developed in accor-
elastomerasexplainedinthesectionondumbbellspecimensin
dance with internationally recognized principles on standard-
Test Methods D412.
ization established in the Decision on Principles for the
3.1.2 formulation, n—the specific chemical composition
Development of International Standards, Guides and Recom-
used in manufacturing a seal elastomer or a reference oil.
mendations issued by the World Trade Organization Technical
3.1.3 percent ultimate elongation, n—the stretch length at
Barriers to Trade (TBT) Committee.
rupture of an elastomer dumbbell oil-aged by running this
procedure minus the rupture stretch length of an untested
2. Referenced Documents
dumbbell, all divided by rupture stretch length of the untested
3
2.1 ASTM Standards:
dumbbell and then multiplied by 100.
D412TestMethodsforVulcanizedRubberandThermoplas-
3.1.4 percent volume change, n—the change in volume of a
tic Elastomers—Tension
test specimen as explained in the procedure for change in
D471Test Method for Rubber Property—Effect of Liquids
volume in Test Method D471.
4. Summary of Test Method
1
This test method is under the jurisdiction of ASTM Committee D02 on
Petroleum Products, Liquid Fuels, and Lubricants and is the direct responsibility of
4.1 Non-referenceoilsaretestedusingamodifiedversionof
Subcommittee D02.B0.03 on Automotive Gear Lubricants & Fluids.
Test Method D471 on specific elastomer compounds. Mea-
CurrenteditionapprovedJuly1,2019.PublishedJuly2019.Originallyapproved
sured quantities are percent ultimate elongation changes (fur-
in 1995. Last previous edition approved in 2017 as D5662–17a. DOI: 10.1520/
D5662-19. ther referred to as just percent elongation changes), durometer
2
Until the next revision of this test method, the ASTM Test Monitoring Center
Type A hardness changes, and percent volume changes. Ref-
will update changes in this test method by means of Information Letters; these can
erenceoilsarerunconcurrentlyinthesameoilbathtomeasure
beobtainedfromtheASTMTestMonitoringCenter,6555PennAve.,Pittsburgh,Pa
consistency from one test to another.
15206-4489. Attention: Administrator. This edition incorporates revisions in all
Information Letters through No. 19-1.
3
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
4
Standards volume information, refer to the standard’s Document Summary page on Available from Society of Automotive Engineers (SAE), 400 Commonwealth
the ASTM website. Dr., Warrendale, PA 15096-0001, http://www.sae.org.
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
D5662 − 19
4.2 The duration of these tests is 240 h. The reference oils weights and balance shall be <0.5 mg. Calibrate internal
5
are available from theAST
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: D5662 − 17a D5662 − 19
Standard Test Method for
Determining Automotive Gear Oil Compatibility with Typical
1
Oil Seal Elastomers
This standard is issued under the fixed designation D5662; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope*
2
1.1 This test method covers the determination of the compatibility of automotive gear oils with specific nitrile, polyacrylate,
and fluoroelastomer oil seal materials.
1.2 Users of this test method should obtain Test Methods D412, D471, and D2240 and become familiar with their use before
proceeding with this test method.
1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of
regulatory limitations prior to use.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization
established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued
by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
2. Referenced Documents
3
2.1 ASTM Standards:
D412 Test Methods for Vulcanized Rubber and Thermoplastic Elastomers—Tension
D471 Test Method for Rubber Property—Effect of Liquids
D2240 Test Method for Rubber Property—Durometer Hardness
D5704 Test Method for Evaluation of the Thermal and Oxidative Stability of Lubricating Oils Used for Manual Transmissions
and Final Drive Axles
D5760 Specification for Performance of Manual Transmission Gear Lubricants
E29 Practice for Using Significant Digits in Test Data to Determine Conformance with Specifications
4
2.2 SAE Standard:
J2360 Lubricating Oil, Gear Multipurpose (Metric) Military Use
3. Terminology
3.1 Definitions of Terms Specific to This Standard:
3.1.1 dumbbell, n—the specific cut shape (Die C) of an elastomer as explained in the section on dumbbell specimens in Test
Methods D412.
3.1.2 formulation, n—the specific chemical composition used in manufacturing a seal elastomer or a reference oil.
3.1.3 percent ultimate elongation, n—the stretch length at rupture of an elastomer dumbbell oil-aged by running this procedure
minus the rupture stretch length of an untested dumbbell, all divided by rupture stretch length of the untested dumbbell and then
multiplied by 100.
1
This test method is under the jurisdiction of ASTM Committee D02 on Petroleum Products, Liquid Fuels, and Lubricants and is the direct responsibility of Subcommittee
D02.B0.03 on Automotive Gear Lubricants & Fluids.
Current edition approved Oct. 1, 2017July 1, 2019. Published November 2017July 2019. Originally approved in 1995. Last previous edition approved in 2017 as
D5662 – 17.D5662 – 17a. DOI: 10.1520/D5662-17A.10.1520/D5662-19.
2
Until the next revision of this test method, the ASTM Test Monitoring Center will update changes in this test method by means of Information Letters; these can be
obtained from the ASTM Test Monitoring Center, 6555 Penn Ave., Pittsburgh, Pa 15206-4489. Attention: Administrator. This edition incorporates revisions in all Information
Letters through No. 17-1.19-1.
3
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
4
Available from Society of Automotive Engineers (SAE), 400 Commonwealth Dr., Warrendale, PA 15096-0001, http://www.sae.org.
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
D5662 − 19
3.1.4 percent volume change, n—the change in volume of a test specimen as explained in the procedure for change in volume
in Test Method D471.
4. Summary of Test Method
4.1 Non-reference oils are tested using a modified version of Test Method D471 on specific elastomer compounds. Measured
quantities are percent ultim
...

Questions, Comments and Discussion