Standard Practice for Full-Scale Chamber Determination of Volatile Organic Emissions from Indoor Materials/Products

SIGNIFICANCE AND USE
5.1 VOCs emitted from materials/products affect indoor air quality (IAQ) in buildings. To determine the impact of these emissions on IAQ, it is necessary to know their emission rates over time. This practice provides guidelines for using a full-scale environmental chamber for testing large materials and full-scale material systems/assemblies.  
5.2 While this practice is developed for measuring VOC emissions, the chamber facilities and methods of evaluation presented in this practice are also useful for a variety of purposes including: (1) testing the emissions during the application process (for example, painting), or other related sources; (2) developing scaleup methods (for example, from small chamber results to a full-scale scenario); (3) studying the interaction between sources and sinks, and validating source/sink models which are the basis for IAQ prediction; (4) testing interactions between source emissions and other compounds in the air (for example, NOx, ozone, SOx); and (5) evaluating the performance of air cleaning devices intended to remove contaminants from indoor air.
SCOPE
1.1 This practice is intended for determining volatile organic compound (VOC) emissions from materials and products (building materials, material systems, furniture, consumer products, etc.) and equipment (printers, photocopiers, air cleaners, etc.) under environmental and product usage conditions that are typical of those found in office and residential buildings.  
1.2 This practice is for identifying VOCs emitted and determining their emission rates over a period of time.  
1.3 This practice describes the design, construction, performance evaluation, and use of full-scale chambers for VOC emission testing.  
1.4 While this practice is limited to the measurement of VOC emissions, many of the general principles and procedures (such as methods for evaluating the general performance of the chamber system) may also be useful for the determination of other chemical emissions (for example, ozone, nitrogen dioxide). Determination of aerosol and particle emissions is beyond the scope of this document.  
1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

General Information

Status
Published
Publication Date
31-Aug-2018
Technical Committee
Drafting Committee
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM D6670-18 - Standard Practice for Full-Scale Chamber Determination of Volatile Organic Emissions from Indoor Materials/Products
English language
21 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
REDLINE ASTM D6670-18 - Standard Practice for Full-Scale Chamber Determination of Volatile Organic Emissions from Indoor Materials/Products
English language
21 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Designation: D6670 − 18
Standard Practice for
Full-Scale Chamber Determination of Volatile Organic
1
Emissions from Indoor Materials/Products
This standard is issued under the fixed designation D6670; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope 2. Referenced Documents
2
2.1 ASTM Standards:
1.1 This practice is intended for determining volatile or-
D1356 Terminology Relating to Sampling and Analysis of
ganiccompound(VOC)emissionsfrommaterialsandproducts
Atmospheres
(building materials, material systems, furniture, consumer
D1914 PracticeforConversionUnitsandFactorsRelatingto
products, etc.) and equipment (printers, photocopiers, air
Sampling and Analysis of Atmospheres
cleaners, etc.) under environmental and product usage condi-
tions that are typical of those found in office and residential D5116 Guide for Small-Scale Environmental Chamber De-
terminations of Organic Emissions from Indoor Materials/
buildings.
Products
1.2 This practice is for identifying VOCs emitted and
D5197 Test Method for Determination of Formaldehyde and
determining their emission rates over a period of time.
OtherCarbonylCompoundsinAir(ActiveSamplerMeth-
1.3 This practice describes the design, construction, perfor-
odology)
mance evaluation, and use of full-scale chambers for VOC
D5466 Test Method for Determination of Volatile Organic
emission testing.
Compounds in Atmospheres (Canister Sampling Method-
ology)
1.4 While this practice is limited to the measurement of
D6196 Practice for Choosing Sorbents, Sampling Param-
VOCemissions,manyofthegeneralprinciplesandprocedures
eters and Thermal Desorption Analytical Conditions for
(such as methods for evaluating the general performance of the
Monitoring Volatile Organic Chemicals in Air
chamber system) may also be useful for the determination of
D6345 Guide for Selection of Methods for Active, Integra-
other chemical emissions (for example, ozone, nitrogen diox-
tive Sampling of Volatile Organic Compounds in Air
ide).Determinationofaerosolandparticleemissionsisbeyond
D7706 Practice for Rapid Screening of VOC Emissions
the scope of this document.
from Products Using Micro-Scale Chambers
1.5 The values stated in SI units are to be regarded as
E741 Test Method for Determining Air Change in a Single
standard. No other units of measurement are included in this
Zone by Means of a Tracer Gas Dilution
standard.
E779 Test Method for DeterminingAir Leakage Rate by Fan
1.6 This standard does not purport to address all of the Pressurization
safety concerns, if any, associated with its use. It is the E1333 Test Method for Determining Formaldehyde Concen-
responsibility of the user of this standard to establish appro- trations in Air and Emission Rates from Wood Products
priate safety, health, and environmental practices and deter- Using a Large Chamber
mine the applicability of regulatory limitations prior to use.
2.2 Other Documents:
1.7 This international standard was developed in accor-
ASHRAE 62.1–2010 Ventilation for Acceptable Indoor Air
3
dance with internationally recognized principles on standard-
Quality
ization established in the Decision on Principles for the
ASHRAE 62.2–2010 Ventilation and Acceptable Indoor Air
3
Development of International Standards, Guides and Recom-
Quality in Low-Rise Residential Buildings
mendations issued by the World Trade Organization Technical
CMEIAQ 1999a A Method for Sampling and Analysis of
Barriers to Trade (TBT) Committee.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
1
This practice is under the jurisdiction ofASTM Committee D22 on Air Quality Standards volume information, refer to the standard’s Document Summary page on
and is the direct responsibility of Subcommittee D22.05 on Indoor Air. the ASTM website.
3
Current edition approved Sept. 1, 2018. Published September 2018. Originally Available from American Society of Heating, Refrigerating, and Air-
approved in 2001. Last previous edition approved in 2013 as D6670 – 13. DOI: Conditioning Engineers, Inc. (ASHRAE), 1791 Tullie Circle, NE, Atlanta, GA
10.1520/D6670-18. 30329, http://www.ashrae.org.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
D6670 − 18
Volatile Organic Compounds in Emission Testing o
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: D6670 − 13 D6670 − 18
Standard Practice for
Full-Scale Chamber Determination of Volatile Organic
1
Emissions from Indoor Materials/Products
This standard is issued under the fixed designation D6670; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope
1.1 This practice is intended for determining volatile organic compound (VOC) emissions from materials and products (building
materials, material systems, furniture, consumer products, etc.) and equipment (printers, photocopiers, air cleaners, etc.) under
environmental and product usage conditions that are typical of those found in office and residential buildings.
1.2 This practice is for identifying VOCs emitted and determining their emission rates over a period of time.
1.3 This practice describes the design, construction, performance evaluation, and use of full-scale chambers for VOC emission
testing.
1.4 While this practice is limited to the measurement of VOC emissions, many of the general principles and procedures (such
as methods for evaluating the general performance of the chamber system) may also be useful for the determination of other
chemical emissions (for example, ozone, nitrogen dioxide). Determination of aerosol and particle emissions is beyond the scope
of this document.
1.5 Values stated in the International System of Units (SI) The values stated in SI units are to be regarded as the standard. No
other units of measurement are included in this standard.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of
regulatory limitations prior to use.
1.7 This international standard was developed in accordance with internationally recognized principles on standardization
established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued
by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
2. Referenced Documents
2
2.1 ASTM Standards:
D1356 Terminology Relating to Sampling and Analysis of Atmospheres
D1914 Practice for Conversion Units and Factors Relating to Sampling and Analysis of Atmospheres
D3686 Practice for Sampling Atmospheres to Collect Organic Compound Vapors (Activated Charcoal Tube Adsorption Method)
D5116 Guide for Small-Scale Environmental Chamber Determinations of Organic Emissions from Indoor Materials/Products
D5197 Test Method for Determination of Formaldehyde and Other Carbonyl Compounds in Air (Active Sampler Methodology)
D5466 Test Method for Determination of Volatile Organic Compounds in Atmospheres (Canister Sampling Methodology)
D6196 Practice for Choosing Sorbents, Sampling Parameters and Thermal Desorption Analytical Conditions for Monitoring
Volatile Organic Chemicals in Air
D6345 Guide for Selection of Methods for Active, Integrative Sampling of Volatile Organic Compounds in Air
D7706 Practice for Rapid Screening of VOC Emissions from Products Using Micro-Scale Chambers
E741 Test Method for Determining Air Change in a Single Zone by Means of a Tracer Gas Dilution
E779 Test Method for Determining Air Leakage Rate by Fan Pressurization
E1333 Test Method for Determining Formaldehyde Concentrations in Air and Emission Rates from Wood Products Using a
Large Chamber
1
This practice is under the jurisdiction of ASTM Committee D22 on Air Quality and is the direct responsibility of Subcommittee D22.05 on Indoor Air.
Current edition approved April 1, 2013Sept. 1, 2018. Published April 2013September 2018. Originally approved in 2001. Last previous edition approved in 20072013 as
D6670 – 01 (2007).D6670 – 13. DOI: 10.1520/D6670-13.10.1520/D6670-18.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
D6670 − 18
IEEE/ASTM SI-10 Standard for Use of the International System of Units (SI): T
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.