Standard Practice for Preliminary Field Testing of Thermoplastic Pipe Joints for Gravity Flow (Non-Pressure) Sewer Lines

SIGNIFICANCE AND USE
5.1 The values recorded are applicable only to the sewer joint being tested and at the time of testing.
SCOPE
1.1 This practice covers procedures for testing single joints of thermoplastic pipe for gravity flow (non-pressure) sewer lines, when using either air or water under low pressure to demonstrate the integrity of the joint. This practice is used for testing 27 in. (675 mm) and larger inside diameter PVC (Polyvinyl Chloride), HDPE (High Density Polyethylene) and PP (Polypropylene) sewer lines utilizing flexible gasketed joints with elastomeric seals, Specification F477.  
1.2 This practice is used for assessing the watertight integrity of a joint at the time of the test. It is not a pipeline acceptance test as it does not evaluate the integrity of the pipe barrel or any long-term pipeline deformation effects from backfill settlement
Note 1: The user of this practice is advised that methods described herein is typically used as a preliminary test to enable the installer to demonstrate the integrity of a sewer pipe joint prior to placement of final backfill. Such testing after initial backfill can detect if a gasket has rolled or dirt was pushed into the joint during the mating of the pipe. Repair of these types of installation problems can be done very quickly and effectively prior to final backfill, but once final backfill is placed, repairs are very difficult and costly.
Note 2: This practice may be used at any time to check the integrity of a joint prior to acceptance testing or to locate a leaking joint when a pipeline fails a hydrostatic infiltration/exfiltration test, vacuum test or air pressure test during any time of the installation and acceptance process.
Note 3: The user of this practice is advised that no correlation has been found between air loss and water leakage.  
1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.  
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

General Information

Status
Published
Publication Date
14-Apr-2021
Technical Committee
Drafting Committee
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM F3058-16(2021) - Standard Practice for Preliminary Field Testing of Thermoplastic Pipe Joints for Gravity Flow (Non-Pressure) Sewer Lines
English language
3 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Designation: F3058 − 16 (Reapproved 2021)
Standard Practice for
Preliminary Field Testing of Thermoplastic Pipe Joints for
Gravity Flow (Non-Pressure) Sewer Lines
This standard is issued under the fixed designation F3058; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope 1.5 This international standard was developed in accor-
dance with internationally recognized principles on standard-
1.1 This practice covers procedures for testing single joints
ization established in the Decision on Principles for the
of thermoplastic pipe for gravity flow (non-pressure) sewer
Development of International Standards, Guides and Recom-
lines, when using either air or water under low pressure to
mendations issued by the World Trade Organization Technical
demonstrate the integrity of the joint. This practice is used for
Barriers to Trade (TBT) Committee.
testing 27 in. (675 mm) and larger inside diameter PVC (Poly-
vinyl Chloride), HDPE (High Density Polyethylene) and PP
2. Referenced Documents
(Polypropylene) sewer lines utilizing flexible gasketed joints
2.1 ASTM Standards:
with elastomeric seals, Specification F477.
F412 Terminology Relating to Plastic Piping Systems
1.2 This practice is used for assessing the watertight integ-
F477 Specification for Elastomeric Seals (Gaskets) for Join-
rity of a joint at the time of the test. It is not a pipeline
ing Plastic Pipe
acceptance test as it does not evaluate the integrity of the pipe
F2487 Practice for Infiltration and Exfiltration Acceptance
barrel or any long-term pipeline deformation effects from
Testing of Installed Corrugated High Density Polyethyl-
backfill settlement
ene and Polypropylene Pipelines
NOTE 1—The user of this practice is advised that methods described
3. Terminology
herein is typically used as a preliminary test to enable the installer to
demonstrate the integrity of a sewer pipe joint prior to placement of final
3.1 Defintions—For definitions of terms relating to plastic
backfill. Such testing after initial backfill can detect if a gasket has rolled
pipe, see Terminology F412.
or dirt was pushed into the joint during the mating of the pipe. Repair of
these types of installation problems can be done very quickly and
4. Summary of Practice
effectively prior to final backfill, but once final backfill is placed, repairs
are very difficult and costly.
4.1 The joint in the sewer line to be tested is covered on the
NOTE 2—This practice may be used at any time to check the integrity
inside of the pipe by a ring with two end element sealing tubes.
of a joint prior to acceptance testing or to locate a leaking joint when a
pipeline fails a hydrostatic infiltration/exfiltration test, vacuum test or air Air or water is introduced at low pressure through a connection
pressure test during any time of the installation and acceptance process.
on the ring into the annular space between the ring and joint.
NOTE 3—The user of this practice is advised that no correlation has
The amount of air, or water, loss is used to determine the
been found between air loss and water leakage.
acceptability of the joint.
1.3 The values stated in inch-pound units are to be regarded
as standard. The values given in parentheses are mathematical 5. Significance and Use
conversions to SI units that are provided for information only
5.1 The values recorded are applicable only to the sewer
and are not considered standard.
joint being tested and at the time of testing.
1.4 This standard does not purport to address all of the
6. Safety Precautions
safety concerns, if any, associated with its use. It is the
responsibility of the user of this standard to establish appro-
6.1 The use of compressed air is dangerous.Always observe
priate safety, health, and environmental practices and deter-
proper sewer line preparation and procedures.
mine the applicability of regulatory limitations prior to use.
6.2 It is imperative that all pressures be relieved completely
before the test apparatus is loosened for removal.
This practice is under the jurisdiction of ASTM Committee F17 on Plastic
Piping Systems and is the direct responsibility of Subcommittee F17.40 on Test
Methods. For referenced ASTM standards, visit the ASTM website, www.astm.org, or
Current edition approved April 15, 2021. Published April 2021. Originally contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
approved in 2016. Last previous edition approved in 2016 as F3058–16. DOI: Standards volume information, refer to the standard’s Document Summary page on
10.1520/F3058–16R21 the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
F3058 − 16 (2021)
6.3 Pressurizing lines for the two end element sealing tubes 8.1.4 An air or water reservoir shall be included in the joint
shall be separate from the lines for pressurizing the void test system. By maintaining a constant supply of air or water in
volume created by the joint test apparatus. The pressures a reservoir, continuous pumping of air or water is not required,
required to seal the end element tubes shall be as specified by and any variances in test equipment and joint space will be
the apparatus manufacturer, and are greater than the pressure negated. The reservoir shall have a minimum volume of 2.5 ft
required to test the joint. The line for pressurizing the void (0.071 m).
volume shall include a 6 psi (41 kPa) pressure relief device to
8.2 Joint Air Test:
reduce hazards and avoid over pressurization.
8.2.1 Observe procedures in 8.1
8.2.2 Pressurize the v
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.