Standard Practice for Identification of Instrumental Methods of Color or Color-Difference Measurement of Materials

SIGNIFICANCE AND USE
The options available in methods for the measurement of color or color-difference are many. These involve choices in: (1) specimens, (2) geometric and spectral properties of instruments, (3) calibration bases for standards used, (4) procedure for sample handling including conditioning, (5) procedure for taking data, and (6) equations for converting instrumental data to final results. Once the measurements have been made, it is essential to document what has been done for the purpose of interlaboratory comparisons, or for future use. A sample form is provided in Fig. 1 to record identifying information applicable to any instrumental method of color or color-difference measurement.
Refer to Guide E179, Practices E991, E1164, E1345, E1708, E1767, E2152, and E2194 and Test Methods D5386, D6166, E1247, E1331, E1347, E1348, and E1349, for specific details of measurements.
SCOPE
1.1 This practice covers the documentation of instrumental measurement of color or color difference for current communication or for future reference. The practice is applicable to instrumental measurements of materials where color is seen by reflected, transmitted or emitted light and any combinations of one or more of these processes. The practice is recommended for documentation of methodology in interlaboratory color-measurement programs.
1.2 An adequate identification of an instrumental measure of color or color-difference consists of five parts:
1.2.1 Nature and source of available samples and the form of specimens actually measured,
1.2.2 Instrumental conditions of measurement, including instrument geometrical and spectral conditions of measurement,  
1.2.3 Standards used,
1.2.4 Data acquisition procedure, and
1.2.5 Color scales employed.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of whoever uses this standard to consult and establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
FIG. 1 Sample Report Form

General Information

Status
Historical
Publication Date
31-Jan-2012
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM E805-12 - Standard Practice for Identification of Instrumental Methods of Color or Color-Difference Measurement of Materials
English language
5 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
REDLINE ASTM E805-12 - Standard Practice for Identification of Instrumental Methods of Color or Color-Difference Measurement of Materials
English language
5 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: E805 – 12
Standard Practice for
Identification of Instrumental Methods of Color or Color-
1
Difference Measurement of Materials
This standard is issued under the fixed designation E805; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope (ASTM Color Scale)
D1535 PracticeforSpecifyingColorbytheMunsellSystem
1.1 This practice covers the documentation of instrumental
D1544 Test Method for Color of Transparent Liquids
measurement of color or color difference for current commu-
(Gardner Color Scale)
nication or for future reference. The practice is applicable to
D2244 Practice for Calculation of Color Tolerances and
instrumental measurements of materials where color is seen by
Color Differences from Instrumentally Measured Color
reflected, transmitted or emitted light and any combinations of
Coordinates
one or more of these processes. The practice is recommended
D5386 Test Method for Color of Liquids Using Tristimulus
for documentation of methodology in interlaboratory color-
Colorimetry
measurement programs.
D6166 Test Method for Color of Naval Stores and Related
1.2 An adequate identification of an instrumental measure
Products (Instrumental Determination of Gardner Color)
of color or color-difference consists of five parts:
E179 Guide for Selection of Geometric Conditions for
1.2.1 Nature and source of available samples and the form
Measurement of Reflection andTransmission Properties of
of specimens actually measured,
3
Materials
1.2.2 Instrumental conditions of measurement, including
E259 Practice for Preparation of Pressed Powder White
instrument geometrical and spectral conditions of measure-
Reflectance Factor Transfer Standards for Hemispherical
ment,
and Bi-Directional Geometries
1.2.3 Standards used,
E284 Terminology of Appearance
1.2.4 Data acquisition procedure, and
E308 Practice for Computing the Colors of Objects by
1.2.5 Color scales employed.
Using the CIE System
1.3 This standard does not purport to address all of the
E313 Practice for Calculating Yellowness and Whiteness
safety concerns, if any, associated with its use. It is the
Indices from Instrumentally Measured Color Coordinates
responsibility of whoever uses this standard to consult and
E991 PracticeforColorMeasurementofFluorescentSpeci-
establish appropriate safety and health practices and deter-
mens Using the One-Monochromator Method
mine the applicability of regulatory limitations prior to use.
E1164 Practice for Obtaining Spectrometric Data for
2. Referenced Documents
Object-Color Evaluation
2
E1247 Practice for Detecting Fluorescence in Object-Color
2.1 ASTM Standards:
3
Specimens by Spectrophotometry
D156 Test Method for Saybolt Color of Petroleum Products
E1331 Test Method for Reflectance Factor and Color by
(Saybolt Chromometer Method)
Spectrophotometry Using Hemispherical Geometry
D1209 Test Method for Color of Clear Liquids (Platinum-
E1345 Practice for Reducing the Effect of Variability of
Cobalt Scale)
Color Measurement by Use of Multiple Measurements
D1500 TestMethodforASTMColorofPetroleumProducts
E1347 Test Method for Color and Color-Difference Mea-
surement by Tristimulus Colorimetry
1
This practice is under the jurisdiction of ASTM Committee E12 on Color and E1348 Test Method for Transmittance and Color by Spec-
Appearance and is the direct responsibility of Subcommittee E12.04 on Color and
trophotometry Using Hemispherical Geometry
Appearance Analysis.
E1349 Test Method for Reflectance Factor and Color by
Current edition approved Feb. 1, 2012. Published February 2012. Originally
Spectrophotometry Using Bidirectional (45°:0° or 0°:45°)
approved in 1981. Last previous edition approved in 2006 as E805 – 06. DOI:
10.1520/E0805-12.
Geometry
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
3
Standards volume information, refer to the standard’s Document Summary page on Withdrawn. The last approved version of this historical standard is referenced
the ASTM website. on www.astm.org.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
E805 – 12
E1708 Practice for Electronic Interchange of Color and
Appearance Data
1

---------------------- Page: 2 ----------------------
E805 – 12
FIG. 1 Sample Report Form
E1767 Practice for Specifying the Geometries of Observa- CIE Publication 51 A Method for Assessing the Quality of
4
tion and Measurement to Characterize the Appearance of Daylight Simu
...

This document is not anASTM standard and is intended only to provide the user of anASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation:E805–06 Designation: E805 – 12
Standard Practice for
Identification of Instrumental Methods of Color or Color-
1
Difference Measurement of Materials
This standard is issued under the fixed designation E805; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope
1.1 This practice covers the documentation of instrumental measurement of color or color difference for current communication
or for future reference. The practice is applicable to instrumental measurements of materials where color is seen by reflected,
transmitted or emitted light and any combinations of one or more of these processes. The practice is recommended for
documentation of methodology in interlaboratory color-measurement programs.
1.2 An adequate identification of an instrumental measure of color or color-difference consists of five parts:
1.2.1 Nature and source of available samples and the form of specimens actually measured,
1.2.2 Instrumental conditions of measurement, including instrument geometrical and spectral conditions of measurement,
1.2.3 Standards used,
1.2.4 Data acquisition procedure, and
1.2.5 Color scales employed.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of whoever uses this standard to consult and establish appropriate safety and health practices and determine the applicability of
regulatory limitations prior to use.
2. Referenced Documents
2
2.1 ASTM Standards:
D156 Test Method for Saybolt Color of Petroleum Products (Saybolt Chromometer Method)
D1209 Test Method for Color of Clear Liquids (Platinum-Cobalt Scale)
D1500 Test Method for ASTM Color of Petroleum Products (ASTM Color Scale)
D1535 Practice for Specifying Color by the Munsell System
D1544 Test Method for Color of Transparent Liquids (Gardner Color Scale)
D2244 Practice for Calculation of Color Tolerances and Color Differences from Instrumentally Measured Color Coordinates
D5386 Test Method for Color of Liquids Using Tristimulus Colorimetry
D6166 Test Method for Color of Naval Stores and Related Products (Instrumental Determination of Gardner Color)
E179 Guide for Selection of Geometric Conditions for Measurement of Reflection and Transmission Properties of Materials
E259 Practice for Preparation of Pressed Powder White Reflectance Factor Transfer Standards for Hemispherical and
Bi-Directional Geometries
E284 Terminology of Appearance
E308 Practice for Computing the Colors of Objects by Using the CIE System
E313 Practice for Calculating Yellowness and Whiteness Indices from Instrumentally Measured Color Coordinates
E991 Practice for Color Measurement of Fluorescent Specimens Using the One-Monochromator Method
E1164 Practice for Obtaining Spectrometric Data for Object-Color Evaluation
E1247 Practice for Detecting Fluorescence in Object-Color Specimens by Spectrophotometry
E1331 Test Method for Reflectance Factor and Color by Spectrophotometry Using Hemispherical Geometry
E1345 Practice for Reducing the Effect of Variability of Color Measurement by Use of Multiple Measurements
E1347 Test Method for Color and Color-Difference Measurement by Tristimulus Colorimetry
E1348 Test Method for Transmittance and Color by Spectrophotometry Using Hemispherical Geometry
1
This practice is under the jurisdiction of ASTM Committee E12 on Color and Appearance and is the direct responsibility of Subcommittee E12.04 on Color and
Appearance Analysis.
Current edition approved JulyFeb. 1, 2006.2012. Published July 2006.February 2012. Originally approved in 1981. Last previous edition approved in 20012006 as
E805–01a.E805 – 06. DOI: 10.1520/E0805-06.10.1520/E0805-12.
2
For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
E805 – 12
FIG. 1 Sample Report Form
E1349 Test Method for Reflectance Factor and Color by Spectrophotometry Using Bidirectional (45:0 or 0:45) Geometry
E1708 Practice for Electronic Interchange of Color and Appearance Data
E1767 Prac
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.