Standard Practice for Radiographic Examination

SIGNIFICANCE AND USE
4.1 This practice establishes the basic parameters for the application and control of the radiographic method. This practice is written so it can be specified on the engineering drawing, specification, or contract. It is not a detailed how-to procedure to be used by the NDT facility and, therefore, must be supplemented by a detailed procedure (see 6.1). Test Methods E1030, E1032, and E1416 contain information to help develop detailed technique/procedure requirements.
SCOPE
1.1 This practice2 establishes the minimum requirements for radiographic examination for metallic and nonmetallic materials.  
1.2 Applicability—The criteria for the radiographic examination in this practice are applicable to all types of metallic and nonmetallic materials. The requirements expressed in this practice are intended to control the quality of the radiographic images and are not intended to establish acceptance criteria for parts and materials.  
1.3 Basis of Application—There are areas in this practice that may require agreement between the cognizant engineering organization and the supplier, or specific direction from the cognizant engineering organization. These items should be addressed in the purchase order or the contract.  
1.3.1 DoD contracts.  
1.3.2 Personnel qualification, 5.1.1.  
1.3.3 Agency qualification, 5.1.2.  
1.3.4 Digitizing techniques, 5.4.5.  
1.3.5 Alternate image quality indicator (IQI) types, 5.5.3.  
1.3.6 Examination sequence, 6.6.  
1.3.7 Non-film techniques, 6.7.  
1.3.8 Radiographic quality levels, 6.9.  
1.3.9 Optical density, 6.10.  
1.3.10 IQI qualification exposure, 6.13.3.  
1.3.11 Non-requirement for IQI, 6.18.  
1.3.12 Examination coverage for welds, A2.2.2.  
1.3.13 Electron beam welds, A2.3.  
1.3.14 Geometric unsharpness, 6.23.  
1.3.15 Responsibility for examination, 6.27.1.  
1.3.16 Examination report, 6.27.2.  
1.3.17 Retention of radiographs, 6.27.8.  
1.3.18 Storage of radiographs, 6.27.9.  
1.3.19 Reproduction of radiographs, 6.27.10 and 6.27.10.1.  
1.3.20 Acceptable parts, 6.28.1.  
1.4 Units—The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.  
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

General Information

Status
Historical
Publication Date
28-Feb-2018
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM E1742/E1742M-18 - Standard Practice for Radiographic Examination
English language
17 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
REDLINE ASTM E1742/E1742M-18 - Standard Practice for Radiographic Examination
English language
17 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Designation: E1742/E1742M − 18
Standard Practice for
1
Radiographic Examination
ThisstandardisissuedunderthefixeddesignationE1742/E1742M;thenumberimmediatelyfollowingthedesignationindicatestheyear
of original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.
A superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the U.S. Department of Defense.
1. Scope* 1.3.20 Acceptable parts, 6.28.1.
2
1.1 Thispractice establishestheminimumrequirementsfor 1.4 Units—The values stated in either SI units or inch-
radiographic examination for metallic and nonmetallic materi- pound units are to be regarded separately as standard. The
als. values stated in each system may not be exact equivalents;
therefore,eachsystemshallbeusedindependentlyoftheother.
1.2 Applicability—The criteria for the radiographic exami-
Combining values from the two systems may result in non-
nationinthispracticeareapplicabletoalltypesofmetallicand
conformance with the standard.
nonmetallic materials. The requirements expressed in this
1.5 This standard does not purport to address all of the
practice are intended to control the quality of the radiographic
safety concerns, if any, associated with its use. It is the
imagesandarenotintendedtoestablishacceptancecriteriafor
responsibility of the user of this standard to establish appro-
parts and materials.
priate safety, health, and environmental practices and deter-
1.3 Basis of Application—There are areas in this practice
mine the applicability of regulatory limitations prior to use.
thatmayrequireagreementbetweenthecognizantengineering
1.6 This international standard was developed in accor-
organization and the supplier, or specific direction from the
dance with internationally recognized principles on standard-
cognizant engineering organization. These items should be
ization established in the Decision on Principles for the
addressed in the purchase order or the contract.
Development of International Standards, Guides and Recom-
1.3.1 DoD contracts.
mendations issued by the World Trade Organization Technical
1.3.2 Personnel qualification, 5.1.1.
Barriers to Trade (TBT) Committee.
1.3.3 Agency qualification, 5.1.2.
1.3.4 Digitizing techniques, 5.4.5.
2. Referenced Documents
1.3.5 Alternate image quality indicator (IQI) types, 5.5.3.
2.1 The following documents form a part of this practice to
1.3.6 Examination sequence, 6.6.
the extent specified herein:
1.3.7 Non-film techniques, 6.7.
3
1.3.8 Radiographic quality levels, 6.9.
2.2 ASTM Standards:
1.3.9 Optical density, 6.10. E94Guide for Radiographic Examination Using Industrial
1.3.10 IQI qualification exposure, 6.13.3.
Radiographic Film
1.3.11 Non-requirement for IQI, 6.18. E543Specification forAgencies Performing Nondestructive
1.3.12 Examination coverage for welds, A2.2.2.
Testing
1.3.13 Electron beam welds, A2.3. E747Practice for Design, Manufacture and Material Group-
1.3.14 Geometric unsharpness, 6.23.
ing Classification of Wire Image Quality Indicators (IQI)
1.3.15 Responsibility for examination, 6.27.1. Used for Radiology
1.3.16 Examination report, 6.27.2.
E801Practice for Controlling Quality of Radiographic Ex-
1.3.17 Retention of radiographs, 6.27.8. amination of Electronic Devices
1.3.18 Storage of radiographs, 6.27.9.
E999Guide for Controlling the Quality of Industrial Radio-
1.3.19 Reproduction of radiographs, 6.27.10 and 6.27.10.1. graphic Film Processing
E1025Practice for Design, Manufacture, and Material
Grouping Classification of Hole-Type Image Quality In-
dicators (IQI) Used for Radiography
1
This practice is under the jurisdiction of ASTM Committee E07 on Nonde-
structive Testing and is the direct responsibility of Subcommittee E07.01 on
Radiology (X and Gamma) Method.
3
Current edition approved March 1, 2018. Published March 2018. Originally For referenced ASTM standards, visit the ASTM website, www.astm.org, or
approved in 1995. Last previous edition approved in 2012 as E1742/E1742M–12. contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
DOI: 10.1520/E1742_E1742M-18. Standards volume information, refer to the standard’s Document Summary page on
2
This practice replaced MIL-STD-453. the ASTM website.
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
E1742/E1742M − 18
E1030Practice for Radiographic Examination of Metallic ISO 5579Non-Destructive Testing
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: E1742/E1742M − 12 E1742/E1742M − 18
Standard Practice for
1
Radiographic Examination
This standard is issued under the fixed designation E1742/E1742M; the number immediately following the designation indicates the year
of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.
A superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the U.S. Department of Defense.
1. Scope*
2
1.1 This practice establishes the minimum requirements for radiographic examination for metallic and nonmetallic materials.
1.2 Applicability—The criteria for the radiographic examination in this practice are applicable to all types of metallic and
nonmetallic materials. The requirements expressed in this practice are intended to control the quality of the radiographic images
and are not intended to establish acceptance criteria for parts and materials.
1.3 Basis of Application—There are areas in this practice that may require agreement between the cognizant engineering
organization and the supplier, or specific direction from the cognizant engineering organization. These items should be addressed
in the purchase order or the contract.
1.3.1 DoD contracts.
1.3.2 Personnel qualification, 5.1.1.
1.3.3 Agency qualification, 5.1.2.
1.3.4 Digitizing techniques, 5.4.5.
1.3.5 Alternate image quality indicator (IQI) types, 5.5.3.
1.3.6 Examination sequence, 6.6.
1.3.7 Non-film techniques, 6.7.
1.3.8 Radiographic quality levels, 6.9.
1.3.9 FilmOptical density, 6.10.
1.3.10 IQI qualification exposure, 6.13.3.
1.3.11 Non-requirement for IQI, 6.18.
1.3.12 Examination coverage for welds, A2.2.2.
1.3.13 Electron beam welds, A2.3.
1.3.14 Geometric unsharpness, 6.23.
1.3.15 Responsibility for examination, 6.27.1.
1.3.16 Examination report, 6.27.2.
1.3.17 Retention of radiographs, 6.27.8.
1.3.18 Storage of radiographs, 6.27.9.
1.3.19 Reproduction of radiographs, 6.27.10 and 6.27.10.1.
1.3.20 Acceptable parts, 6.28.1.
1.4 Units—The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated
in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values
from the two systems may result in non-conformance with the standard.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety safety, health, and healthenvironmental practices and determine the
applicability of regulatory limitations prior to use.
1.6 This international standard was developed in accordance with internationally recognized principles on standardization
established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued
by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
1
This practice is under the jurisdiction of ASTM Committee E07 on Nondestructive Testing and is the direct responsibility of Subcommittee E07.01 on Radiology (X and
Gamma) Method.
Current edition approved Nov. 1, 2012March 1, 2018. Published November 2012March 2018. Originally approved in 1995. Last previous edition approved in 20112012
as E1742 - 11.E1742/E1742M – 12. DOI: 10.1520/E1742_E1742M-12.10.1520/E1742_E1742M-18.
2
This practice replaced MIL-STD-453.
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
E1742/E1742M − 18
2. Referenced Documents
2.1 The following documents form a part of this practice to the extent specified herein:
3
2.2 ASTM Standards:
E94 Guide for Radiographic Examination Using Industrial Radiographic Film
E543 Specification for Agencies Performing Nondestructive Testing
E747 Practice for Design, Manufacture and Material Grouping Classification of Wire Image Quality Indicators (IQI) Used for
Radiology
E801 Practice for Controlling Quality of Radiographic Examination of Electronic Devices
E999 Guide for Controlling the Quality of Industrial Radiographic Film Processing
E1025 Practice for Design, Manufacture, and Material Grouping Classification of Hole-Type Image Quality Indicators (IQI)
Used for Radiography
E1030 Practice for Radiographic Examination of Metallic Castings
E10
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.