Fixed firefighting systems - Automatic sprinkler systems - Design, installation and maintenance

This standard specifies requirements and gives recommendations for the design, installation and maintenance of fixed fire sprinkler systems in buildings and industrial plant, and particular requirements for sprinkler systems, which are integral to measures for the protection of life.
This standard covers only the types of sprinkler specified in EN 12259-1 (see annex L).
The requirements and recommendations of this standard are also applicable to any addition, extension, repair or other modification to a sprinkler system. They are not applicable to water spray or deluge systems.
It covers the classification of hazards, provision of water supplies, components to be used, installation and testing of the system, maintenance, and the extension of existing systems, and identifies construction details of buildings which are the minimum necessary for satisfactory performance of sprinkler systems complying with this standard.
This standard does not cover water supplies to systems other than sprinklers. Its requirements can be used as guidance for other fixed fire fighting extinguishing systems, however, provided that any specific requirements for other fire fighting extinguishing supplies are taken into account.
This standard also covers sprinkler system kits.
The requirements are not valid for automatic sprinkler systems on ships, in aircraft, on vehicles and mobile fire appliances or for below ground systems in the mining industry.

Ortsfeste Brandbekämpfungsanlagen - Automatische Sprinkleranlagen - Planung, Installation und Instandhaltung

Diese Norm legt Anforderungen fest und gibt Empfehlungen für die Planung, den Einbau und die Instandhaltung von ortsfesten Sprinkleranlagen in Gebäuden und Industrieanlagen. Sie legt Anforderungen an besondere Sprinkleranlagen fest, die für Maßnahmen zum Schutz des menschlichen Lebens wesentlich sind.
Diese Norm gilt nur für die in EN 12259-1 festgelegten Sprinklerarten (siehe Anhang L).
Die Anforderungen und Empfehlungen dieser Norm gelten auch für jede Ergänzung, Erweiterung, Reparatur oder sonstige Veränderung an Sprinkleranlagen. Sie gelten nicht für Sprühwasser-Löschanlagen.
Diese Norm umfasst die Klassifizierung von Gefahren, die Art der Wasserversorgung, die zu verwendenden Bauteile, den Einbau und die Prüfung der Anlage, die Instandhaltung und Erweiterung bestehender Anlagen. Sie weist Konstruktionsdetails von Gebäuden aus, die für das ordnungsgemäße Funktionieren von Sprinkleranlagen nach dieser Norm erforderlich sind.
Diese Norm gilt nicht für Wasserversorgungen für andere als Sprinkleranlagen. Ihre Anforderungen können als Leitfaden für andere ortsfeste Brandbekämpfungsanlagen verwendet werden, wobei jedoch vorausgesetzt wird, dass für andere Löschmittel besondere Anforderungen zu berücksichtigen sind.
Diese Norm gilt auch für Bausätze von Sprinkleranlagen.
Die Anforderungen gelten nicht für automatische Sprinkleranlagen auf Schiffen, in Flugzeugen, auf Fahrzeugen und mobilen Brandbekämpfungseinrichtungen oder für unterirdische Anlagen in der Bergbauindustrie.

Installations fixes de lutte contre l'incendie - Systèmes d'extinction automatiques du type sprinkleur - Calcul, installation et maintenance

La présente norme spécifie des exigences et fournit des recommandations pour la conception, l'installation et la maintenance d'installations fixes de lutte contre l'incendie de type sprinkleur dans des bâtiments et des installations industrielles et spécifie des exigences particulières pour les systèmes d'extinction de type sprinkleur faisant partie intégrante de mesures de protection des personnes.
La présente norme ne concerne que les types de sprinkleur spécifiés dans l'EN 12259-1 (voir annexe L).
Les exigences et recommandations de la présente norme sont également applicables à tout ajout, extension ou autre modification apportée à un système d'extinction de type sprinkleur. Elles ne sont pas applicables aux installations à pulvérisation d'eau ou de type déluge.
La présente norme couvre la classification des dangers, l'installation de sources d'eau, les éléments à utiliser, l'installation et les essais du système, la maintenance et l'extension de systèmes existants, et elle identifie les détails de construction des bâtiments qui sont nécessaires au fonctionnement satisfaisant des systèmes d'extinction de type sprinkleur conformes à la présente norme.
La présente norme ne couvre pas les sources d'eau alimentant des systèmes autres que les systèmes de type sprinkleur. Cependant, Ses exigences peuvent être utilisées comme guide pour les autres installations fixes de lutte contre l'incendie, ceci sous réserve que les exigences spécifiques à ces autres systèmes de lutte contre l'incendie soient prises en compte également.
La présente norme couvre également les kits de sprinkleurs en kit.
Les exigences ne sont pas valables pour les systèmes d'extinction automatiques de type sprinkleur installés sur des bateaux, dans des aéronefs, sur des véhicules et des engins mobiles d'incendie, ni pour les systèmes d'extinction souterrains dans l'industrie minière.

Vgrajene naprave za gašenje – Avtomatski sprinklerski sistemi - Projektiranje, vgradnja in vzdrževanje

General Information

Status
Withdrawn
Publication Date
19-Aug-2003
Withdrawal Date
15-Apr-2004
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
16-Apr-2004
Completion Date
16-Apr-2004

Relations

Buy Standard

Standard
EN 12845:2003
English language
175 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Vgrajene naprave za gašenje – Avtomatski sprinklerski sistemi - Projektiranje, vgradnja in vzdrževanjeOrtsfeste Brandbekämpfungsanlagen - Automatische Sprinkleranlagen - Planung, Installation und InstandhaltungInstallations fixes de lutte contre l'incendie - Systemes d'extinction automatiques du type sprinkleur - Calcul, installation et maintenanceFixed firefighting systems - Automatic sprinkler systems - Design, installation and maintenance13.220.20Fire protectionICS:Ta slovenski standard je istoveten z:EN 12845:2003SIST EN 12845:2003en01-december-2003SIST EN 12845:2003SLOVENSKI
STANDARD



SIST EN 12845:2003



EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 12845August 2003ICS 13.220.20English versionFixed firefighting systems - Automatic sprinkler systems -Design, installation and maintenanceInstallations fixes de lutte contre l'incendie - Systèmesd'extinction automatiques du type sprinkleur - Calcul,installation et maintenanceOrtsfeste Brandbekämpfungsanlagen - AutomatischeSprinkleranlagen - Planung, Installation und InstandhaltungThis European Standard was approved by CEN on 29 November 2002.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the Management Centre has the same status as the officialversions.CEN members are the national standards bodies of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece,Hungary, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Slovakia, Spain, Sweden, Switzerland and UnitedKingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2003 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 12845:2003 ESIST EN 12845:2003



EN 12845:2003 (E)2ContentspageForeword.9Introduction.101Scope.122Normative references.123Terms and definitions.134Contract planning and documentation.204.1General.204.2Initial considerations.204.3Preliminary or estimating stage.214.4Design stage.214.4.1General.214.4.2Summary schedule.214.4.3Installation layout drawings.224.4.4Water supply.255Extent of sprinkler protection.275.1Buildings and areas to be protected.275.1.1Permitted exceptions within a building.275.1.2Necessary exceptions.275.2Storage in the open air.285.3Fire resistant separation.285.4Protection of concealed spaces.285.5Height difference between the highest and lowest sprinklers.286Classification of occupancies and fire hazards.286.1General.286.2Hazard classes.296.2.1Light Hazard - LH.296.2.2Ordinary Hazard - OH.296.2.3High Hazard - HH.306.3Storage.316.3.1General.316.3.2Storage Configuration.327Hydraulic design criteria.347.1LH, OH and HHP.347.2High Hazard Storage - HHS.357.2.1General.357.2.2Ceiling or roof protection only.357.2.3Intermediate level in-rack sprinklers.367.3Pressure and flow requirements for pre-calculated systems.387.3.1LH and OH systems.387.3.2HHP and HHS systems without in-rack sprinklers.398Water supplies.428.1General.428.1.1Duration.428.1.2Continuity.428.1.3Frost protection.428.2Maximum water pressure.42SIST EN 12845:2003



EN 12845:2003 (E)38.3Connections for other services.438.4Housing of equipment for water supplies.448.5Test facility devices.448.5.1At control valve sets.448.5.2At water supplies.458.6Water Supply test.458.6.1General.458.6.2Storage tank and pressure tank supplies.458.6.3Town main, booster pump, elevated private reservoir and gravity tank supplies.459Type of water supply.459.1General.459.2Town mains.459.2.1General.459.2.2Boosted mains.469.3Storage tanks.469.3.1General.469.3.2Water volume.469.3.3Refill rates for full capacity tanks.489.3.4Reduced capacity tanks.489.3.5Effective capacity of tanks and dimensions of suction chambers.499.3.6Strainers.519.4Inexhaustible sources - Settling and suction chambers.519.4.1.519.5Pressure tanks.549.5.1General.549.5.2Housing.549.5.3Minimum capacity (water).549.5.4Air pressure and contents.549.5.5Charging with air and water.559.5.6Control and safety equipment.559.6Choice of water supply.569.6.1Single water supplies.569.6.2Superior water supplies.569.6.3Duplicate water supplies.569.6.4Combined water supplies.579.7Isolation of water supply.5710Pumps.5810.1General.5810.2Multiple pump arrangements.5810.3Compartments for pumpsets.5810.3.1General.5810.3.2Sprinkler protection.5810.3.3Temperature.5910.3.4Ventilation.5910.4Maximum temperature of water supply.5910.5Valves and accessories.5910.6Suction conditions.5910.6.1General.5910.6.2Suction pipe.6010.7Performance characteristics.6310.7.1Pre-calculated systems - LH and OH.6310.7.2Pre-calculated systems - HHP and HHS with no in-rack sprinklers.6410.7.3Calculated systems.6410.7.4Pressure and water capacity of boosted town mains.6410.7.5Pressure switches.6510.8Electrically driven pumpsets.6510.8.1General.6510.8.2Electricity supply.65SIST EN 12845:2003



EN 12845:2003 (E)410.8.3Main switchboard.6510.8.4Installation between the main switchboard and the pump controller.6610.8.5Pump controller.6610.8.6Monitoring of pump operation.6610.9Diesel engine driven pumpsets.6710.9.1General.6710.9.2Engines.6710.9.3Cooling system.6710.9.4Air filtration.6710.9.5Exhaust system.6710.9.6Fuel, fuel tank and fuel feed pipes.6810.9.7Starting mechanism.6810.9.8Electric starter motor batteries.6910.9.9Battery chargers.6910.9.10Siting of batteries and chargers.7010.9.11Starter alarm indication.7010.9.12Tools and spare parts.7010.9.13Engine tests and exercising.7011Installation type and size.7111.1Wet pipe installations.7111.1.1General.7111.1.2Protection against freezing.7111.1.3Size of installations.7211.2Dry pipe installations.7211.2.1General.7211.2.2Size of installations.7211.3Alternate installations.7311.3.1General.7311.3.2Size of installations.7311.4Pre-action installations.7311.4.1General.7311.4.2Automatic detection system.7411.4.3Size of installations.7411.5Subsidiary dry pipe or alternate extension.7411.5.1General.7411.5.2Size of subsidiary extensions.7411.6Subsidiary water spray extension.7412 Spacing and location of sprinklers.7512.1General.7512.2Maximum area of coverage per sprinkler.7512.3Minimum distance between sprinklers.7712.4Location of sprinklers in relation to building construction.7712.5Intermediate sprinklers in HH occupancies.8312.5.1General.8312.5.2Maximum vertical distance between sprinklers at intermediate levels.8312.5.3Horizontal position of sprinklers at intermediate levels.8312.5.4Numbers of rows of sprinklers at each level.8512.5.5HHS intermediate sprinklers in non-shelved racks.8512.5.6HHS intermediate sprinklers below solid or slatted shelves in racks (ST5 and ST6).8613Pipe sizing and layout.8713.1General.8713.1.1Pipe sizing.8713.2Calculation of pressure losses in pipework.8713.2.1Pipe friction loss.8713.2.2Static pressure difference.8813.2.3Velocity.8813.2.4Pressure loss through fittings and valves.8813.2.5Accuracy of calculations.90SIST EN 12845:2003



EN 12845:2003 (E)513.3Pre-calculated systems.9013.3.1General.9013.3.2Location of Design Points.9013.3.3Light Hazard - LH.9113.3.4Ordinary Hazard - OH.9313.3.5High hazard - HHP and HHS (except intermediate level sprinklers).9513.4.1Design density.10413.4.2Locations of the area of operation.10513.4.3Shape of the area of operation.10513.4.4Minimum sprinkler discharge pressure.10813.4.5Minimum pipe diameters.10814Sprinkler design characteristics and uses.10914.1General.10914.2Sprinkler types and application.10914.2.1General.10914.2.2Ceiling, flush, recessed and concealed pattern.11014.2.3Sidewall pattern.11014.2.4Flat spray pattern.11114.3Flow from sprinklers.11114.4Sprinkler temperature ratings.11114.5Sprinkler thermal sensitivity.11114.5.1General.11114.5.2Interaction with other measures.11214.6Sprinkler guards.11214.7Sprinkler water shields.11214.8Sprinkler rosettes.11314.9Corrosion protection of sprinklers.11315Valves.
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.