EN 13121-3:2026
(Main)GRP tanks and vessels for use above ground - Part 3: Design and workmanship
- Abstract
This document gives requirements for the design, fabrication, inspection, testing and verification of GRP tanks and vessels with or without thermoplastics lining for storage or processing of fluids, factory made or site built, non-pressurized or pressurized up to 10 bar, for use above ground. Further requirements are presented in normative Annex G.
The terms vessels and tanks as used in this document include branches up to the point of connection to pipe work or other equipment by bolting and supports, brackets or other attachments bonded directly to the shell.
Fatigue is not considered a design criterion, as keeping strains below the limit strain inherently prevents fatigue failure. This document is applicable to vessels and tanks exposed to temperatures between -40 °C and 120 °C.
This document does not apply to:
- tanks and vessels for the transport of fluids;
- underground storage tanks;
- spherical vessels;
- vessels and tanks of irregular shape;
- tanks and vessels with double containment where the double wall is considered structural;
- tanks and vessels which are subject to the risk of explosion, or failure of which can cause an emission of radioactivity;
- specification for fibre reinforced cisterns of one piece and sectional construction for the storage, above ground, of cold water (see EN 13280).
- Status
- Not Published
- Publication Date
- 22-Dec-2026
- Technical Committee
- CEN/TC 210 - GRP tanks and vessels
- Drafting Committee
- CEN/TC 210 - GRP tanks and vessels
- Current Stage
- 5060 - Closure of Vote - Formal Approval
- Start Date
- 18-Jun-2026
- Due Date
- 18-Jun-2026
- Completion Date
- 18-Jun-2026
EN 13121-3:2026 is a CEN standard for GRP tanks and vessels used above ground. It specifies how to design, fabricate, inspect, test, and verify GRP tanks and vessels with or without thermoplastics lining for storage or processing of fluids. The document is aimed at manufacturers, designers, inspectors, purchasers, and approval bodies that need a common basis for structural design, workmanship, and documentation.
What does EN 13121-3:2026 specify?
EN 13121-3:2026 specifies requirements for GRP tanks and vessels above ground, including factory-made and site-built units, whether non-pressurized or pressurized up to 10 bar. It also applies to vessels and tanks with branches up to the connection point and to attachments bonded directly to the shell.
The scope covers equipment exposed to temperatures between -40 °C and 120 °C. Fatigue is not used as a design criterion in this document, because the design approach is based on keeping strains below the limit strain.
The standard excludes:
- transport tanks and vessels for fluids
- underground storage tanks
- spherical vessels
- irregularly shaped vessels and tanks
- double containment where the double wall is structural
- tanks and vessels subject to explosion risk or possible radioactive release
- fibre reinforced cisterns for above-ground storage of cold water, which are covered by EN 13280
EN 13121-3:2026 is organized into clauses for scope, references, terms, symbols, documentation, materials, mechanical properties, design strain and loadings, design, design analysis, supports, seismic loading, anchorage, structures and fittings, local load analysis, quality control, and marking. Its annexes add product testing, calculation methods, test methods, laminator approval, design verification methods, and water-related requirements.
| Annex | What it covers |
|---|---|
| Annex A | Product testing for serial or batch production |
| Annex B | Lamina and laminate thickness, modulus, stiffness, and strain calculations |
| Annex C | Tests for pressureless tanks and vessels and hydraulic pressure testing |
| Annex D | Material and joint test methods, including welds, laminates, hardness, resistivity, creep, HDT, and pull-off strength |
| Annex E | Approval testing of laminators |
| Annex F | Typical methods, general requirements, important determination results, and design factors |
| Annex G | Additional requirements for design and manufacturing, effects on water and food, recycling, and storage of substances hazardous to water |
What are the key requirements of EN 13121-3:2026?
EN 13121-3:2026 combines material rules, design calculations, workmanship controls, and verification steps. In practice, a project team uses it to define the laminate, check loads and stability, document the design, and prove the finished tank or vessel by inspection and testing.
Documentation and process information
Clause 5 requires the manufacturer to collect the process requirements and prepare the technical information and final documentation needed for the tank or vessel. This matters because the design, material selection, fabrication, and inspection records have to match the intended service before work starts and before handover.
Materials and physical properties
Clause 6 covers the chemical protective barrier, thermoplastics linings, resin-based linings, flammability, and electrical resistivity. Clause 7 then links those materials to measurable properties such as heat deflection temperature, laminate construction, thickness, inter-laminar shear strength, peel strength, pull-off strength, and allowable design factors.
In practice, this is the section that tells the manufacturer what properties must be checked before a laminate or liner is used in service. It is also where the document distinguishes between basic and advanced design approaches.
Design strain and laminate resistance
Clause 8 sets the framework for limit design strain and limit design laminate loadings, and it gives methods for deriving mechanical values from laminates with or without experimental test data. This matters because the design checks are based on the actual laminate behavior, not on generic material assumptions.
The clause also shows how laminate thickness and test strain fit into the design proof. For the reader, that means the laminate build-up must be known well enough to calculate and justify its load capacity.
Loads and verification method
Clause 9 covers external loads such as snow, wind, seismic actions, insulation loads, loads from connections, agitation, inadequate venting, personnel loading, and temperature effects. It uses a partial factor method, so the load combinations and the factored actions are part of the design proof.
This is important in practice because the vessel is not designed only for internal pressure. The design also has to account for the real installation environment and the way different actions combine.
Geometry-specific design checks
Clause 10 gives the detailed design checks for cylinders, conical shells, dished ends, flat bottoms, skirts, seams, openings, branches, compensating laminates, large diameter pipes, and pipe fittings. Clause 11 covers bolted flange connections, including full face flanges, stub flanges with backing rings, and butt and strap jointed flanges.
This is the core of the document for structural design work. It tells the designer where buckling, local reinforcement, seam construction, flange loads, and joint details have to be checked, and when more advanced analysis or experimental verification is needed.
Supports, anchorage, and handling features
Clauses 12, 14, and 15 deal with supports, anchorage, internal and external fittings, lifting devices, and trunnions. These clauses matter because the shell has to carry not only fluid load but also support reactions, uplift, handling loads, and loads from saddles, skirts, rings, and lugs.
For horizontal vessels, the document gives saddle support arrangements and the need for free movement or controlled expansion. For vertical vessels, it addresses leg supports, ring supports, ring girders, skirt supports, and anchor bolts.
Quality control and final acceptance
Clause 17 covers works requirements, raw material storage, manufacturing conditions, documentation, fabrication of thermoplastics liners, inspection and testing after fabrication, and experimental design verification for pressure vessels. It also includes visual and dimensional inspection and records for materials, manufacturing, and quality control.
Clause 18 lists the marking information that has to accompany each tank or vessel. In practice, this gives the handover data that buyers, inspectors, and maintenance teams need to identify the equipment and its design limits.
What terms does EN 13121-3:2026 define?
EN 13121-3:2026 defines the roles and pressure terms used throughout the design and inspection rules.
- Manufacturer - the organization that designs, manufactures, and tests the vessel or tank to this document.
- Purchaser - the organization or individual that buys the finished tank or vessel and states the process requirements.
- Authorized inspecting authority - the body that may check compliance with the document, used when PS is at or below 0,5 bar.
- Notified body - the certificated organization listed by the European Commission of pressure equipment, used when PS is above 0,5 bar.
- Internal inspection authority - an inspector from the manufacturer who is independent from the workshop.
- Vessel - a closed container under applied pressure or vacuum, including branches up to the first flanged connection.
- Tank - a container for fluids that is only subject to hydrostatic head and is freely vented to atmosphere, including branches up to the first flanged connection.
- PS - the maximum allowable pressure specified by the manufacturer.
- TS - the maximum or minimum allowable temperature specified by the manufacturer.
- PT - the test pressure applied during pressure testing.
Who uses EN 13121-3:2026?
EN 13121-3:2026 is used by GRP tank and vessel manufacturers, structural and mechanical designers, and fabrication teams that build laminate shells and lined constructions. It is also used by quality managers, inspectors, purchasers, and notified bodies when they need to check design data, fabrication records, inspection evidence, and test results.
In practice, it supports tasks such as specifying a laminate, checking support and anchorage loads, approving thermoplastics welds, reviewing flange details, and accepting final documentation.
What changed in EN 13121-3:2026 from the previous edition?
EN 13121-3:2026 supersedes EN 13121-3:2016.
Which standards are used with EN 13121-3:2026?
EN 13121-3:2026 relies on a set of related standards for materials, design actions, steel parts, welding, testing, and calibration.
- EN 13121-1, EN 13121-2, EN 13121-4 - the companion parts for raw materials, chemical resistance, and delivery, installation, and maintenance.
- EN 1990, EN 1991-1-3, EN 1991-1-4, EN 1991-4, EN 1998-1 - basis of structural design and the action sets for snow, wind, tanks, and seismic design.
- EN 1993-1-1, EN 1993-1-6, EN 13445-3 - steel design and shell stability rules used where steel backing rings, flanges, or other steel parts are checked.
- EN 13067 - qualification of plastics welding personnel for thermoplastics welded assemblies.
- EN 59, EN ISO 75-2, EN ISO 291, EN ISO 527-4, EN ISO 1172, EN ISO 2592, EN ISO 3915, EN ISO 7500-1, EN ISO 9513, EN ISO 11357-2, EN ISO 14125, EN ISO 14692-3, ISO 48-2, ASTM D4541 - test, conditioning, and calibration methods used for hardness, temperature resistance, tensile and flexural properties, glass content, flash point, resistivity, machine calibration, extensometer calibration, DSC, piping system design, rubber hardness, and pull-off strength.
- EN 10025-2 - the steel grade reference for S235JR used in a backing ring context.
- EN 13555:2021 - the gasket seating stress reference used in flange design.
What does the EN 13121-3:2026 document contain?
EN 13121-3:2026 contains design equations, load combinations, figures, and tables for the full structural design of GRP tanks and vessels. It gives methods for cylinders, cones, dished ends, flat bottoms, skirts, saddles, openings, branches, and flanges, together with buckling and stability checks.
The document also contains detailed annexes for testing and verification. Annex C gives pressure and hydraulic test methods, Annex D gives material and joint test methods, Annex E covers laminator approval, and Annex F provides design factors and calculation approaches used in verification work.
Several tables and figures support practical fabrication and checking work, including flange and bolt details, support arrangements, acceptable imperfections, dimensional tolerances, and the geometry of critical design regions. For engineers and inspectors, these parts are the working material used for design review, testing, and acceptance rather than general background text.
Relations
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
Get Certified
Connect with accredited certification bodies for this standard
Institut za varilstvo d.o.o. (Welding Institute)
Slovenia's leading welding institute since 1952. ISO 3834, EN 1090, pressure equipment certification, NDT personnel, welder qualification. Only IIW Au
Sponsored listings
Frequently Asked Questions
EN 13121-3:2026 is a draft published by the European Committee for Standardization (CEN). Its full title is "GRP tanks and vessels for use above ground - Part 3: Design and workmanship". This standard covers: This document gives requirements for the design, fabrication, inspection, testing and verification of GRP tanks and vessels with or without thermoplastics lining for storage or processing of fluids, factory made or site built, non-pressurized or pressurized up to 10 bar, for use above ground. Further requirements are presented in normative Annex G. The terms vessels and tanks as used in this document include branches up to the point of connection to pipe work or other equipment by bolting and supports, brackets or other attachments bonded directly to the shell. Fatigue is not considered a design criterion, as keeping strains below the limit strain inherently prevents fatigue failure. This document is applicable to vessels and tanks exposed to temperatures between -40 °C and 120 °C. This document does not apply to: - tanks and vessels for the transport of fluids; - underground storage tanks; - spherical vessels; - vessels and tanks of irregular shape; - tanks and vessels with double containment where the double wall is considered structural; - tanks and vessels which are subject to the risk of explosion, or failure of which can cause an emission of radioactivity; - specification for fibre reinforced cisterns of one piece and sectional construction for the storage, above ground, of cold water (see EN 13280).
This document gives requirements for the design, fabrication, inspection, testing and verification of GRP tanks and vessels with or without thermoplastics lining for storage or processing of fluids, factory made or site built, non-pressurized or pressurized up to 10 bar, for use above ground. Further requirements are presented in normative Annex G. The terms vessels and tanks as used in this document include branches up to the point of connection to pipe work or other equipment by bolting and supports, brackets or other attachments bonded directly to the shell. Fatigue is not considered a design criterion, as keeping strains below the limit strain inherently prevents fatigue failure. This document is applicable to vessels and tanks exposed to temperatures between -40 °C and 120 °C. This document does not apply to: - tanks and vessels for the transport of fluids; - underground storage tanks; - spherical vessels; - vessels and tanks of irregular shape; - tanks and vessels with double containment where the double wall is considered structural; - tanks and vessels which are subject to the risk of explosion, or failure of which can cause an emission of radioactivity; - specification for fibre reinforced cisterns of one piece and sectional construction for the storage, above ground, of cold water (see EN 13280).
EN 13121-3:2026 is classified under the following ICS (International Classification for Standards) categories: 23.020.10 - Stationary containers and tanks. The ICS classification helps identify the subject area and facilitates finding related standards.
EN 13121-3:2026 has the following relationships with other standards: It is inter standard links to EN ISO 23908:2025, EN ISO 18113-1:2024, EN ISO 11197:2019, EN ISO 5361:2023, EN ISO 5840-1:2021, EN ISO 14708-5:2022, EN ISO 14630:2024, EN ISO 9680:2021, EN ISO 17664-1:2021, EN ISO 80369-7:2021, EN ISO 11608-1:2022, EN ISO 10651-4:2023, EN ISO 14708-3:2022, EN ISO 25539-3:2024, EN ISO 7439:2023. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN 13121-3:2026 is associated with the following European legislation: EU Directives/Regulations: 2014/68/EU; Standardization Mandates: M/071, M/601. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
EN 13121-3:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 3.1 manufacturer
- 3.2 purchaser
- 3.3 authorized inspecting authority
- 3.4 vessel
- 3.5 notified body
- 3.6 internal inspection authority
- 3.7 tank
- 3.8 laminate
- 3.9 gel coat
- 3.10 cure
- 3.11 post cure
- 3.12 maximum allowable pressure
- 3.13 differential pressure
- 3.14 design pressure
- 3.15 maximum/minimum allowable temperature
- 3.16 test temperature
- 3.17 test pressure
- 4 Symbols and abbreviations
- 5 Information and requirements to be supplied and documented
- 5.1 General
- 5.2 Information to be obtained by the manufacturer
- 5.3 Information to be prepared by the manufacturer
- 5.4 Final documentation
- 6 Material
- 6.1 General
- 6.2 Chemical protective barrier
- 6.3 Flammability
- 6.4 Electrical resistivity
- 7 Mechanical properties
- 7.1 General
- 7.2 Heat deflection temperature
- 7.3 Laminate construction
- 7.4 Laminate thickness
- 7.5 Laminate properties
- 7.6 Inter-laminar shear strength
- 7.7 Peel strength of laminates
- 7.8 Pull-off strength of laminates and thermoplastic liner
- 7.9 Selection of physical properties of materials and allowable design factors
- 7.9.2 the material properties shall be
- 8 Determination of design strain and loadings
- 8.1 General
- 8.2 Limit design strains
- 8.3 Limit design laminate loadings
- 8.4 Determination of the mechanical values from laminates
- 8.5 Laminate thickness
- 9 Design
- 9.1 Introduction
- 9.2 Determination of external loads
- 9.3 Verification by the partial factor method
- 5 F,i
- 5 F,i d,R d,R
- 5 F,i
- 5 F,i
- 9.4 Drawings and design calculations
- 9.5 Design details
- 10 Design analysis
- 10.1 Symbols and units
- 10.2 Vertical vessels or tanks, cylinders under loads (t < 0,01∙D)
- 10.3 Cylindrical shells subject to compressive loadings — critical buckling criteria
- 0.5 𝐷𝐷⋅𝑡𝑡
- 0.5 𝐷𝐷⋅𝑡𝑡
- 2 C of stiffener
- 10.4 Conical shells
- 10.5 Dished end
- 10.6 Design of flat bottoms and skirts for vertical tanks and vessels
- 0.5 𝐷𝐷⋅𝑡𝑡
- 0.5 𝐷𝐷⋅𝑡𝑡 𝐷𝐷
- 10.7 Circumferential seams for cylindrical joints
- 10.8 Openings, branches and compensating laminate
- 1 FRP 2 steel insert nut
- 10.9 Flat Panels or Blind flanges
- 3 GRP flange 4 gasket
- 10.10 Horizontal tanks and vessels
- 10.11 Large diameter pipes and pipe fittings
- 11 Bolted flange connections
- 11.1 General
Introduction
The five parts of EN 13121 together define the responsibilities of the tank or vessel manufacturer and the materials to be used in their manufacture.
EN 13121-1 specifies the requirements and acceptance conditions for the raw materials - resins, curing agents, thermoplastics linings, reinforcing materials and additives. These requirements are necessary in order to establish the chemical resistance properties determined in EN 13121-2 and the mechanical, thermal and design properties determined in this part of EN 13121. Together with the workmanship principles determined in this Part 3, requirements and acceptance conditions for raw materials ensure that the tank or vessel will be able to meet its design requirements. EN 13121-4 specifies recommendations for delivery, handling, installation and maintenance of GRP tanks and vessels The design and manufacture of GRP tanks and vessels involve a number of different materials such as resins, thermoplastics and reinforcing fibres and a number of different manufacturing methods. It is implicit that vessels and tanks covered by this document are made only by manufacturers who are competent and suitably equipped to comply with all the requirements of this document, using materials manufactured by competent and experienced material manufacturers.
Metallic vessels, and those manufactured from other isotropic, homogeneous materials, are conveniently designed by calculating permissible loads based on measured tensile and ductility properties. GRP, on the other hand, is a laminar material, manufactured through the successive application of individual layers of reinforcement. As a result there are many possible combinations of reinforcement type that will meet the structural requirement of any one-design case. This allows the designer to select the laminate construction best suited to the available manufacturing facilities and hence be most cost effective. In considering a layered GRP structure it is assumed that it is the glass reinforcement that provides the stiffness and strength required to resist mechanical loadings. Also, since the quantity of glass reinforcement is most readily assessed by weight, the weight of glass per unit area (m) is used instead of thickness in determining mechanical properties, thus the concepts of load and modulus are replaced by unit strength (u) and unit modulus (X), these being defined in Table 1.
It is possible that future advances in resin technology would allow tanks and vessels to be considered for operating temperatures above 120 °C. Should such a situation arise and a manufacturer wish to take advantage of such developments then all other requirements of this document will be maintained and such tanks and vessels will only be designed in accordance with the advanced design method given in 7.9.3. NOTE To convert a unit load, or a unit modulus to a load and a modulus respectively, U and X may be simply divided by t, where t is the thickness per weight of glass per unit area of the lamina, or laminate under consideration.
oSIST prEN 13121-3:2022 prEN 13121-3:2022 (E)
1 Scope
This document gives requirements for the design, fabrication, inspection, testing and verification of GRP tanks and vessels with or without thermoplastics lining for storage or processing of fluids, factory made or site built, non-pressurized or pressurized up to 10 bar, for use above ground. Further requirements are presented in normative Annex G.
The terms vessels and tanks as used in this document include branches up to the point of connection to pipe work or other equipment by bolting and supports, brackets or other attachments bonded directly to the shell. This document covers vessels and tanks subject to temperatures between – 40 °C and 120 °C. Excluded from this part of EN 13121 are:
- tanks and vessels for the transport of fluids;
- underground storage tanks;
- spherical vessels;
- vessels and tanks of irregular shape;
- tanks and vessels with double containment where the double wall is considered structural;
- tanks and vessels which are subject to the risk of explosion, or failure of which may cause an emission of radioactivity;
- specification for fibre reinforced cisterns of one piece and sectional construction for the storage, above ground, of cold water (see EN 13280).
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 59:2016, Glass reinforced plastics — Determination of indentation hardness by means of a Barcol hardness tester EN 1990:2021, Eurocode — Basis of structural design EN 1991-1-3:2010, Eurocode 1 — Actions on structures — Part 1-3: General actions - Snow loads EN 1991-1-4:2010, Eurocode 1: Actions on structures — Part 1-4: General actions - Wind actions EN 1991-4:2010, Eurocode 1 — Actions on structures — Part 4: Silos and tanks EN 1993-1-1:2010, Eurocode 3: Design of steel structures — Part 1-1: General rules and rules for buildings EN 1993-1-6:2017, Eurocode 3 — Design of steel structures — Part 1-6: Strength and Stability of Shell Structures EN 1998-1:2010, Eurocode 8: Design of structures for earthquake resistance — Part 1: General rules, seismic actions and rules for buildings EN 10025-2:2019, Hot rolled products of structural steels — Part 2: Technical delivery conditions for non-alloy structural steels EN 13067:2020, Plastics welding personnel — Qualification testing of welders — Thermoplastics welded assemblies
oSIST prEN 13121-3:2022 prEN 13121-3:2022 (E) EN 13121-1:2021, GRP tanks and vessels for use above ground — Part 1: Raw materials — Specification conditions and acceptance conditions EN 13121-2:2003, GRP tanks and vessels for use above ground — Part 2: Composite materials — Chemical resistance EN 13121-4:2005, GRP tanks and vessels for use above ground — Part 4: Delivery, installation and maintenance EN 13445-3:2021, Unfired pressure vessels — Part 3: Design EN ISO 75-2:2013, Plastics — Determination of temperature of deflection under load — Part 2: Plastics and ebonite (ISO 75-2) EN ISO 291:2008, Plastics — Standard atmospheres for conditioning and testing (ISO 291) EN ISO 527-4:2021, Plastics — Determination of tensile properties — Part 4: Test conditions for isotropic and orthotopic fibre-reinforced plastic composites (ISO 527-4) EN ISO 1172:1998, Textile-glass-reinforced plastics — Prepregs, moulding compounds and laminates — Determination of the textile-glass and mineral-filler content — Calcination methods (ISO 1172) EN ISO 2592:2017, Petroleum and related products — Determination of flash and fire points — Cleveland open cup method (ISO 2592) EN ISO 3915:2022, Plastics — Measurement of resistivity of conductive plastics (ISO 3915) EN ISO 7500-1:2018, Metallic materials — Calibration and verification of static uniaxial testing machines — Part 1: Tension/compression testing machines — Calibration and verification of the force-measuring system (ISO 7500-1) EN ISO 9513:2012, Metallic materials — Calibration of extensometer systems used in uniaxial testing (ISO 9513) EN ISO 11357-2:2020, Plastics — Differential scanning calorimetry (DSC) — Part 2: Determination of glass transition temperature and glass transition step height (ISO 11357-2) EN ISO 14125:2011, Fibre-reinforced plastic composites — Determination of flexural properties (ISO 14125) EN ISO 14692-3:2018, Petroleum and natural gas industries — Glass-reinforced plastics (GRP) piping — Part 3:
System design (ISO 14692-3) ISO 48-2:2018, Rubber, vulcanized or thermoplastic — Determination of hardness (hardness between 10 IRHD and 100 IRHD) ASTM D4541:2017, Standard Test Method for Pull-Off Strength of Coatings Using Portable Adhesion Testers
oSIST prEN 13121-3:2022 prEN 13121-3:2022 (E)
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply. ISO and IEC maintain terminology databases for use in standardization at the following addresses:
- ISO Online browsing platform: available at https://www.iso.org/obp
- IEC Electropedia: available at https://www.electropedia.org
3.1 manufacturer
organization that designs, manufactures and tests the vessel or tank in accordance with this document
3.2 purchaser
organization or individual that buys the finished vessel or tank and specifies the process requirements
3.3 authorized inspecting authority
body or organization that maybe required to check that the design, materials and construction comply with this document Note 1 to entry: For this document, when PS ≤ 0,5 bar.
3.4 vessel
closed container subject to applied pressure or vacuum, with or without hydrostatic head, including branches up to the first flanged connection
3.5 notified body
certificated organization listed by the European commission of pressure equipment Note 1 to entry: For this document, when PS > 0,5 bar.
3.6 internal inspection authority
inspector from the manufacturer which is independent from the workshop
3.7 tank
container for the storage of fluids subject only to the fluid hydrostatic head and freely vented to atmosphere, including branches up to the first flanged connection
3.8 laminate
resin reinforced with glass fibre
3.9 gel coat
thin layer of resin on the surface of a laminate that may or not be reinforced with a glass or a synthetic fibre tissue
3.10 cure
chemical reaction resulting in the polymerized laminate
oSIST prEN 13121-3:2022 prEN 13121-3:2022 (E)
3.11 post cure
application of heat to take the polymerization to a final stage
3.12 maximum allowable pressure
PS maximum pressure without consideration of the hydrostatic pressure for which the equipment is designed, as specified by the manufacturer
3.13 differential pressure
difference of pressure on both sides of a component
3.14 design pressure
p D design pressure used in the calculations for a component
3.15 maximum/minimum allowable temperature
TS maximum/minimum temperatures for which the equipment is designed, as specified by the manufacturer
3.16 test temperature
temperature at which the pressure test of the equipment is carried out
3.17 test pressure
PT pressure to which the tank or vessel is tested
oSIST prEN 13121-3:2022 prEN 13121-3:2022 (E)
4 Symbols and abbreviations
For the purposes of this document, the symbols and abbreviations common to all clauses and annexes are given in Table 1. All dimensions are given in millimetres.
Further symbols are defined in the relevant clauses as required. Table 1 — Standard symbols and abbreviations Symbol Unit Definition A mm Distance a mm Dimension b mm Dimension d mm Diameter D mm Internal diameter of tank, vessel Δ - Difference or additional 𝑋𝑋
E N/mm Modulus of elasticity = 𝑡𝑡 ε % Strain F - Buckling design factor ϕ ° Half the angle at the apex of the cone Θ ° Support saddle angle
g Gravity m/s γ - Partial factor for material property m γ - Partial factor for action F,i hi mm Height of dished end H mm Height of cone
I Second moment of area mm k - Correction factor K - Overall design factor l mm Length L mm Overall length
m Mass per unit area kg/m M Nmm Bending moment u N/mm Unit load = load/width ν – Poisson's ratio P N Direct load
p Pressure N/mm Q N Shear load r mm Knuckle radius R mm Radius ρ 3 Density of liquid kg/m 𝑈𝑈 𝑛𝑛
σ N/mm Stress = and 𝑡𝑡 𝑡𝑡
oSIST prEN 13121-3:2022 prEN 13121-3:2022 (E) Symbol Unit Definition t mm Thickness
τ Shear stress N/mm T °C Temperature TS °C Design temperature U N/mm Unit load for the laminate lam
U Ultimate tensile unit strength of the laminate (UTUS) N/mm per kg/m glass
V Volume m x – Coordinate in axial direction X N/mm Unit modulus = Load/width x strain
X Unit tensile-modulus of the lamina per kg/m glass N/mm per kg/m glass
n N/mm Applied unit load Table 2 — Abbreviations Abbreviations CSM - Chopped strand mat ECTFE - Ethylene-chlorotrifluoroethylene copolymer FEP - Fluorinated ethylene-propylene copolymer FU - Furane FW - Filament winding HDT °C Heat deflection temperature IRHD ° International rubber hardness ln - Natural logarithm PF - Phenolic PFA - Perfluoro-alkoxy copolymer PP-B - Polypropylene, block polymer PP-H - Polypropylene, homopolymer PP-R - Polypropylene, random polymer PVC-U - Polyvinyl chloride, unplasticized PVDF - Polyvinylidene fluoride UP - Unsaturated polyester VE - Vinyl ester WR - Woven roving CRL - Chemical Resistant Layer, see EN 13121–2 VL - Veil Layer, see EN 13121–2 TPL - Thermoplastics Liner, see EN 13121–2 Lam - Laminate OD - Outside Diameter ID - Inside Diameter For laminates with layers deviating from 0° or 90°, the classical laminate theory according to Tsai, Puck or Hyer [5] shall be applied.
oSIST prEN 13121-3:2022 prEN 13121-3:2022 (E)
5 Information and requirements to be supplied and documented
5.1 General
The manufacturer shall produce a design and fabrication report as detailed in 17.3. This shall be certified by the manufacturer and be available for approval by the purchaser and/or inspection authority as appropriate. The design/fabrication report shall be issued to the purchaser and a copy kept by the manufacturer for a minimum of five years.
It shall be the manufacturer responsibility to conduct production tests as specified in Clause 7 and to record the results to permit verification that such tanks/vessels are in compliance with this document. The tests as specified in Clause 7 and report along with the definitive documented items and requirements specified in this document shall be satisfied before a claim of compliance with this document can be made and verified.
5.2 Information to be obtained by the manufacturer
The following information shall be supplied by the purchaser and shall be fully documented. Both the definitive requirements specified throughout the document and the documented items shall be satisfied before claim of compliance with this document can be made and verified.
a) Process conditions:
1) materials to be handled (names, concentration, relative densities and toxicity) including likely impurities or contaminations; 2) design pressure (or vacuum) including test requirements and design temperature; 3) operating pressure (or vacuum) and temperature; 4) mode of operation, e.g. process cycling conditions; 5) any abrasion or erosion problems that may be encountered; b) site conditions:
1) nature of ambient atmosphere including any extremes of temperature; 2) superimposed loads, e.g. wind, snow and associated pipework; 3) loads imposed by personnel during erection and operation; 4) seismic loading; 5) general layout of site; c) special conditions:
1) boiling; 2) vibration due to adjacent plant; 3) agitation details; 4) danger of mechanical impact and damage; 5) loads imposed during transport;
oSIST prEN 13121-3:2022 prEN 13121-3:2022 (E) 6) finish, e.g. if fire-resisting; d) details of any special or additional test or inspection required and where these shall be carried out; e) exemption to apply a pigmented coating to the vessel before final inspection; f) facilities for testing; g) applicable regulations e.g. laws, statutory orders and decrees; h) name of Inspecting Authority, if applicable; i) requirements for packaging, despatch and installation.
5.3 Information to be prepared by the manufacturer
The manufacturer shall, before commencing manufacture, prepare calculations, drawings and a construction specification in documented form, which shall be made available as required. This specification document shall include but shall not be limited to the following:
Dished ends: Lay-up details, crown radius, inside knuckle radius, torispherical shape plus minimum thickness. Shell barrel: Lay-up details, thickness, diameter.
Flanges (including blind flanges): Type, standard and pressure rating as indicated in Tables 24 to 29 or for non-standard flanges: minimum thickness, drilling, inside and outside diameters, hub dimensions and facing details.
Gaskets: Type, rating, material, thickness, inside and outside diameters and gasket seating data. Branches, nozzles, drains: The lay-up details, dimensions such as the wall thickness and outside diameter. Also the method of assembly, loads to be specified if applicable; location of openings relative to each other. Body joints: Lay-up details, wall thickness and length.
Reinforcement: Details for nozzles, supports, lifting lugs, etc. Covers, manholes: Lay-up details, dimensions including minimum thickness, drilling size of bolt holes and pitch circle diameter.
Conical sections: Lay-up details, minimum thickness and straight length of cone, including angle of cone, radius of knuckle to shell (if applicable); diameter at large and small ends of cone. Supports (horizontal vessel): Number of saddles dimensions including baseplate. Foundation details: distance from tangent line of dished ends to centre of supports, distance between supports and heights of vessel centre line to support foot baseplate.
Supports (vertical vessel): Skirt dimensions including diameter, height, thickness, lay-up details including method of attachment to shell/dished end; if supports are used, number off, thickness of webs, height, etc., base ring diameters, inside and outside, thickness, number and pitch of holding down bolts. Lifting lugs: Number of, thickness, hole size, lifting angle, lug dimensions, location of lugs, overlay details. Flat plates: Lay-up details, length, breadth and thickness of stiffeners, if fitted, including pitch, number of. Internals: Brackets, tray supports, etc.
Tolerances: Any special tolerances that are required above those given in Figures 64 to 67. Flat Bases: Requirements for the use of flat bases to be in accordance with EN 13121-4:2005. Attachment for ladders /access platforms and other fittings: Details of method of attachment and overlay construction.
oSIST prEN 13121-3:2022 prEN 13121-3:2022 (E)
5.4 Final documentation
The final documentation shall be in accordance with the requirements of Subclause 17.3.
6 Material
6.1 General
The materials of construction to be used for tanks and vessels to this European Standard shall conform to the requirements of EN 13121-1:2021.
The recommendations of the raw material suppliers for the usage of their materials shall be followed. Pigments shall not be used except when required for inclusion in the external resin flow coat, or to meet the requirements of 6.3 and 6.4.
Limited use of thixotropic agents may be made provided their inclusion does not interfere with visual examination (see Table 32), or the chemical and mechanical properties of the cured resin system as required by EN 13121-2:2003.
6.2 Chemical protective barrier
6.2.1 General
The chemical protective barrier shall be selected in accordance with the requirements of EN 13121-2:2003. The chemical barrier construction shall be ignored in any strength, or stability calculation.
6.2.2 Thermoplastics linings
These linings are designated as TPL in EN 13121-2:2003, 4.4. The minimum thickness of the linings shall be in accordance with EN 13121-2:2003, Table 1.
6.2.3 Resin based linings
Where a resin based lining is used as the chemical barrier, the selection of the type of barrier to be used for any application and its corresponding thickness shall be in accordance with the relevant sections of EN 13121-2:2003.
Where the barrier is designed as a single protective system, reference (SPL) in clauses of EN 13121-2:2003, the surface veil (VL) may be either C glass, synthetic veil, carbon fibre or ECR glass. The subsequent chopped strand mat(s), or sprayed fibre layers shall be applied to the VL before cure and shall have fibre content between 25 % and 35 % by mass.
...