Terminations for steel wire ropes - Safety - Part 7: Symmetric wedge socket

This European Standard specifies the minimum requirements for symmetrical wedge socket terminations for stranded steel wire ropes conforming to EN 12385-5 for lifts.
This European Standard covers those symmetric wedge sockets intended for use at temperatures between
-20 °C and 100 °C.
This European Standard only covers those symmetric wedge sockets that have welded socket bodies.
An example of the construction and sizes of a symmetric wedge socket is given in informative Annex A.
The informative Annex B gives the recommendations for the safe use and inspection of symmetric wedge socket according to Annex A.
This European Standard deals with all significant hazards, hazardous situations and events relevant to symmetric wedge sockets for terminations for steel wire ropes, when used as intended and under conditions of misuse which are reasonable foreseeable by the manufacturer.
The hazards covered by this European Standard are identified in Clause 4.
This European Standard applies to symmetric wedge sockets, which are manufactured after the date of its publication.

Endverbindungen für Drahtseile aus Stahldraht - Sicherheit - Teil 7: Symmetrische Seilschlösser

4
Diese Europäische Norm legt die Mindestanforderungen an symmetrische Seilschlösser für Endverbindungen
an Aufzugseilen nach EN 12385-5 fest.
Diese Europäische Norm gilt für symmetrische Seilschlösser, die für den Gebrauch bei Temperaturen
zwischen −20 °C und 100 °C bestimmt sind.
Diese Europäische Norm gilt nur für symmetrische Seilschlösser mit geschweißtem Gehäuse.
Der informative Anhang A enthält ein Beispiel für die Konstruktion und die Maße eines symmetrischen Seil-schlosses.
Der informative Anhang B enthält Empfehlungen für den sicheren Gebrauch und die Prüfung von symme-trischen
Seilschlössern nach Anhang A.
Diese Europäische Norm behandelt alle signifikanten Gefährdungen, Gefährdungssituationen und -ereignisse,
die für symmetrische Seilschlösser für Endverbindungen für Drahtseile aus Stahldraht relevant sind, wenn
diese zweckbestimmend verwendet, und die Bedingungen der Fehlanwendung, die durch den Hersteller an-gemessen
vorhersehbar sind, beachtet werden.
Gefährdungen, die in dieser Norm behandelt werden, sind in Abschnitt 4 angegeben.
Diese Europäische Norm ist für symmetrische Seilschlösser anwendbar, die nach dem Datum ihrer Veröffent-lichung
hergestellt

Terminaisons pour câbles en acier - Sécurité - Partie 7 : Boîte à coin symétrique

La présente Norme européenne spécifie les prescriptions minimales de sécurité des terminaisons de boîte à coin symétrique destinées aux câbles en acier toronnés pour ascenseurs conformes à l’EN 12385-5.
La présente Norme européenne couvre les boîtes à coin symétrique prévues pour être utilisées à des températures comprises entre –20 °C et 100 °C.
La présente Norme européenne traite uniquement des boîtes à coin symétrique dont le corps est soudé.
L’Annexe informative A donne un exemple de construction et de dimensions d’une boîte à coin symétrique.
L’Annexe informative B donne des recommandations permettant l’utilisation et le contrôle en toute sécurité des boîtes à coin symétrique conformes à l’Annexe A.
La présente Norme européenne traite de tous les phénomènes dangereux et de toutes les situations et événements dangereux significatifs correspondant aux boîtes à coin symétrique particulières aux terminaisons de câbles en acier, lorsqu’elles sont utilisées dans les conditions prévues ainsi que dans les conditions de mauvais usage raisonnablement prévisibles par le fabricant.
Les phénomènes dangereux couverts par la présente Norme européenne sont identifiés à l’Article 4.
La présente Norme européenne s’applique aux boîtes à coin symétrique qui sont fabriquées après la date de publication

Zaključki jeklenih žičnih vrvi – Varnost – 7. del: Simetrični zagozdni spoji

General Information

Status
Withdrawn
Publication Date
13-Jun-2006
Withdrawal Date
21-Oct-2008
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
22-Oct-2008
Completion Date
22-Oct-2008

Relations

Buy Standard

Standard
EN 13411-7:2006
English language
20 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Endverbindungen für Drahtseile aus Stahldraht - Sicherheit - Teil 7: Symmetrische SeilschlösserTerminaisons pour câbles en acier - Sécurité - Partie 7 : Boîte a coin symétriqueTerminations for steel wire ropes - Safety - Part 7: Symmetric wedge socket77.140.99Drugi železni in jekleni izdelkiOther iron and steel products53.020.30Pribor za dvigalno opremoAccessories for lifting equipmentICS:Ta slovenski standard je istoveten z:EN 13411-7:2006SIST EN 13411-7:2006en01-oktober-2006SIST EN 13411-7:2006SLOVENSKI
STANDARD
EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 13411-7June 2006ICS 21.060.70; 53.020.30 English VersionTerminations for steel wire ropes - Safety - Part 7: Symmetricwedge socketTerminaisons pour câbles en acier - Sécurité - Partie 7 :Boîte à coin symétriqueEndverbindungen für Drahtseile aus Stahldraht - Sicherheit- Teil 7: Symmetrische SeilschlösserThis European Standard was approved by CEN on 10 May 2006.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the Central Secretariat or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the officialversions.CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France,Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania,Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2006 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 13411-7:2006: ESIST EN 13411-7:2006

Construction and sizes for one design of symmetric wedge socket with welded socket body.13 Annex B (informative)
Recommendations for safe use and inspection of symmetric wedge sockets conforming to Annex A, to be provided by the manufacturer.16 Annex ZA (informative)
Relationship between this European Standard and the Essential Requirements of EU Directive 95/16/EC.18 Annex ZB (informative)
Relationship between this European Standard and the Essential Requirements of EU Directive 98/37/EC.19 Bibliography.20
-20 °C and 100 °C. This European Standard only covers those symmetric wedge sockets that have welded socket bodies. An example of the construction and sizes of a symmetric wedge socket is given in informative Annex A. The informative Annex B gives the recommendations for the safe use and inspection of symmetric wedge socket according to Annex A. This European Standard deals with all significant hazards, hazardous situations and events relevant to symmetric wedge sockets for terminations for steel wire ropes, when used as intended and under conditions of misuse which are reasonable foreseeable by the manufacturer. The hazards covered by this European Standard are identified in Clause 4. This European Standard applies to symmetric wedge sockets, which are manufactured after the date of its publication. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 1050:1996,
Safety of machinery — Principles for risk assessment EN 1289:1998,
Non-destructive testing of welds — Penetrant testing of welds — Acceptance levels EN 1290:1998,
Non-destructive examination of welds — Magnetic particle examination of welds EN 10045-1,
Metallic materials — Charpy impact test — Part 1: Test method EN 12385-2:2002, Steel wire ropes — Safety — Part 2: Definitions, designation and classification EN 12385-5:2002,
Steel wire ropes — Safety — Part 5: Stranded ropes for lifts EN ISO 4063, Welding and allied processes - Nomenclature of processes and reference numbers (ISO 4063:1998) EN ISO 5817,
Welding — Fusion-welded joints in steel, nickel, titanium and their alloys (beam welding excluded) — Quality levels for imperfections (ISO 5817:2003) EN ISO 7500-1:2004,
Metallic materials — Verification of static uniaxial testing machines — Part 1: Tension/compression testing machines — Verification and calibration of the force-measuring system
(ISO 7500-1:2004) ) EN ISO 12100-1:2003, Safety of machinery — Basic concepts, general principles for design — Part 1:
Basic terminology, methodology (ISO 12100-1:2003) EN ISO 12100-2:2003, Safety of machinery — Basic concepts, general principles for design — Part 2: Technical principles (ISO 12100-2:2003) SIST EN 13411-7:2006

EN ISO 12100-2:2003, EN 12385-2:2002 and the following apply. 3.1 symmetric wedge socket assembly consisting of a socket body, wedge, and pin and securing means for the pin; when assembled the centre line of the pin is marginally offset (by one half rope diameter, see Figure B.1) to the longitudinal axis of the live portion of the rope
3.2 socket body principal component of a wedge socket termination having an internal tapered form suitable for receiving a wedge (see 3.3) and the rope with which the wedge is associated, see Figure A.1 3.3 wedge flat tapered component with peripheral groove, suitable for fitting into a tapered socket body to accommodate a rope of matching nominal diameter, see Figure A.1 3.4 pin removable component intended to facilitate connection of the socket body to its anchorage point 3.5 lot number of symmetric wedge sockets from which samples are selected for testing purposes which are of the same type and dimension, each of their constituent components manufactured during the same production run from material of the same cast and subjected to the same heat treatment process 4 List of significant hazards This European Standard contains all the significant hazards, hazardous situations and events, as far as they are dealt with in this European Standard, identified by risk assessment as significant for this type of steel wire rope termination that require action to eliminate or reduce the risk. In particular, the hazard caused by accidental release of a load, or release of a load due to failure of a symmetric wedge socket, puts at risk, either directly or indirectly, the safety or health of those persons within the hazard zone. Errors in the fitting of accessories can also lead to premature failure and this European Standard contains dimensional and geometrical requirements to allow correct fit. Table 1 contains those hazards that require action to reduce risk identified by risk assessment as being specific and significant for symmetric wedge sockets. SIST EN 13411-7:2006

Mechanical hazard due to inadequacy of strength 6
7 1.3 Cutting or shearing hazard 7 15 Errors of fitting 7
5 Safety requirements and/or measures 5.1 Geometry of wedge and socket body Symmetric wedge socket terminations for ropes shall conform to the following geometrical criteria
(see Figure A.1): • the wedge groove angle (.) shall be the same as the socket angle in the body (); • the wedge shall be symmetric; • the internal side surfaces of the socket body and the wedge in contact with the rope shall be straight; • the grooves of the body and the wedge shall have no surface irregularities, such as, protrusions or joints which could influence the intimate contact with the rope; • the clamping length between the socket body and the wedge shall be at least 7,3 times the nominal rope diameter d; • the radius r3 of the wedge at the bottom of the groove at the large end shall be at least 1 times the nominal diameter d of the rope. 5.2 Security of the pin The pin shall be provided with a means for securing it in position when in operation. 5.3 Welded socket body The welding and allied process shall conform to one of those specified in EN ISO 4063. The person who supervises the production process shall be trained in the chosen welding process. The quality of the welding joint shall be in accordance with assessment group B of EN ISO 5817:2003. There shall be no melted on weld chips. The ligament distance in the root of the welding joint shall be 1 mm for material thickness up to 6 mm and
1,5 mm for material thickness more than 6 mm up to and including 12 mm. The penetration of the root of the welding shall be avoided. There shall be no increase of the welding joint in the area of contact with the rope. The welding joint shall have a bonding area of at least 70 % at the joint edge. SIST EN 13411-7:2006
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.