Abstract

ISO 10298:2018 lists the best available acute-toxicity data of gases taken from a search of the current literature to allow the classification of gases and gas mixtures for toxicity by inhalation.

Status
Not Published
Publication Date
11-Feb-2027
Current Stage
5060 - Closure of Vote - Formal Approval
Start Date
11-Nov-2026
Due Date
11-Nov-2026
Completion Date
11-Nov-2026

Buy Documents

FprEN ISO 10298 is a CEN standard for gas cylinders, gases and gas mixtures. It specifies how to determine toxicity by inhalation so a gas or gas mixture can be classified and the cylinder valve outlet can be selected accordingly. The document is aimed at the people who classify gases, prepare gas mixtures, and choose compatible valve outlets for cylinders.

What does FprEN ISO 10298 specify?

FprEN ISO 10298 specifies a way to use acute inhalation toxicity data for gases and gas mixtures. In practice, it supports the classification of gases by toxicity and the selection of cylinder valve outlets for compatible gas groups.

The document is organized into four clauses, two informative annexes, and a bibliography.

AnnexWhat it covers
Annex ASelection of an LC value for a particular gas
Annex BLC values for toxic gases and toxic vapours used in gas mixtures

What are the key requirements of FprEN ISO 10298?

FprEN ISO 10298 centers on how to assign a toxicity value to a gas or gas mixture, then use that value for classification. The document combines literature-based data, a test method for new data, and a calculation method for mixtures.

  • Clause 1 states that the document uses the best available acute-toxicity data found in current literature. That matters because the classification is only as good as the evidence behind it, and the standard is built around existing data rather than new mandatory testing for every product.

  • Clause 3 defines the toxicity framework. It sets out toxicity level groups for gas classification and links them to LC values, which is the practical basis for deciding whether a gas is non-toxic, toxic, or very toxic in use.

  • Clause 4.1 gives two routes for determining toxicity: a test method or a calculation method. For gas mixtures, the document prefers calculation when component toxicity data are available, which reduces unnecessary inhalation testing and supports animal welfare.

  • Clause 4.2.1 says that when new toxicity data are considered for inclusion, an internationally recognized test method such as OECD TG 403 should be used. In practice, that means new data should come from a recognized acute inhalation toxicity procedure rather than from ad hoc reporting.

  • Clause 4.2.2 points to Annex B for pure gases. Annex B lists LC values for toxic gases and toxic vapours used in gas mixtures, so users can find the reference value they need for a specific substance.

  • Clause 4.3 gives the calculation method for gas mixtures. The LC of the mixture is calculated from the toxic components present, and the mixture is then classified using the toxicity levels in Clause 3. For users, this is the main working rule when a cylinder contains a blend rather than a single gas.

  • Clause 4.3 also notes that synergistic effects are not considered in the formula. That is important because the calculated result is based on the component gases, so a user still needs judgment if a mixture has unusual combined effects.

  • Annex A explains how an LC value is selected for a particular gas when literature data are uneven or incomplete. It favors 1 h exposure data, prefers rat data first, and then gives a fallback order for other animals and other evidence. In practice, Annex A tells the user how to justify a value when the evidence is not straightforward.

What terms does FprEN ISO 10298 define?

FprEN ISO 10298 uses a small set of toxicology terms that drive the whole classification method.

  • Lethal concentration 50 (LC) is the air concentration expected to cause death in 50% of a defined test population after a stated exposure time.
  • Toxicity level is the document’s grouping of gases and gas mixtures by inhalation toxicity, which is then used for classification.
  • Lethal dose 50 (LD) is the amount of a material that causes death in 50% of a test animal group when given all at once.
  • Lethal concentration low value is the lowest concentration reported to have caused death, other than the LC value itself, and it is used when selecting or estimating an LC value.
  • Approximate lethal concentration (ALC) is a reported concentration used in place of a precise LC value when the literature does not provide a more exact result.
  • LC values in this document are tied to 1 h exposure for gases, which is why exposure time matters when comparing data.

Who uses FprEN ISO 10298?

FprEN ISO 10298 is used by people who need to classify gas toxicity and make cylinder and outlet decisions from that classification.

  • Gas cylinder manufacturers use it when choosing or checking cylinder valve outlets for compatible gas groups.
  • Gas mixture producers use it when they need to classify a blend from the toxicity of its components.
  • Laboratory toxicologists and test providers use it when preparing or evaluating acute inhalation toxicity data for inclusion.
  • Quality managers and safety specialists use it when they need a documented basis for product classification and hazard communication.
  • Transport and regulatory teams use it when a gas or mixture needs a toxicity classification for shipping or dangerous goods work.

What changed in FprEN ISO 10298 from the previous edition?

FprEN ISO 10298 is the fourth edition and it cancels and replaces ISO 10298:2018.

  • Annex B has been updated to include new toxic gases being added to ISO 14456.
  • Some LC values have been updated.
  • Addendum 1 has been incorporated into Clause 4.3.

Which standards are used with FprEN ISO 10298?

FprEN ISO 10298 refers to several companion standards and guidance documents that support its method.

  • ISO 10286 provides the terms and definitions used in Clause 3.
  • ISO 14456 provides gas properties and associated classification codes, and the introduction uses it for compatible gas groups.
  • ISO 5145 is named in the introduction as the standard that specifies valve outlet dimensions for different compatible gas groups.
  • ISO 10156 is named in the bibliography and relates to fire potential and oxidizing ability, which is part of the wider gas-classification context.
  • OECD TG 403 is the example test method named in Clause 4.2.1 for new acute inhalation toxicity data.

What does the FprEN ISO 10298 document contain?

FprEN ISO 10298 contains a short clause structure, two informative annexes, and a bibliography. Clause 4 provides the working method for determining toxicity, including the calculation formula for gas mixtures and the treatment of pure gases.

Annex A gives a selection algorithm for choosing an LC value, including time adjustment, animal choice, read-across logic, and fallback approaches when direct data are limited. It also includes a figure that summarizes the selection path.

Annex B provides tables of LC values and literature sources for toxic gases and toxic vapours used in gas mixtures. The bibliography collects the literature and related standards used to support those LC values and the selection logic.

Relations

Effective Date
12-Feb-2026
Effective Date
25-Oct-2023
Effective Date
25-Oct-2023

Buy Documents

Get Certified

Connect with accredited certification bodies for this standard

ECOCERT

Organic and sustainability certification.

COFRAC France Verified

Eurofins Food Testing Global

Global leader in food, environment, and pharmaceutical product testing.

COFRAC Luxembourg Verified

Intertek Bangladesh

Intertek certification and testing services in Bangladesh.

BAB Bangladesh Verified

Sponsored listings

Frequently Asked Questions

FprEN ISO 10298 is a draft published by the European Committee for Standardization (CEN). Its full title is "Gas cylinders - Gases and gas mixtures - Determination of toxicity for the selection of cylinder valve outlets (ISO/FDIS 10298:2026)". This standard covers: ISO 10298:2018 lists the best available acute-toxicity data of gases taken from a search of the current literature to allow the classification of gases and gas mixtures for toxicity by inhalation.

ISO 10298:2018 lists the best available acute-toxicity data of gases taken from a search of the current literature to allow the classification of gases and gas mixtures for toxicity by inhalation.

FprEN ISO 10298 is classified under the following ICS (International Classification for Standards) categories: 71.100.20 - Gases for industrial application. The ICS classification helps identify the subject area and facilitates finding related standards.

FprEN ISO 10298 has the following relationships with other standards: It is inter standard links to ISO 10298, EN ISO 10298:2020, EN ISO 10298:2020/A1:2022. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

FprEN ISO 10298 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 3.1 lethal concentration 50
  • 3.2 toxicity level
  • 3.3 lethal dose 50
  • 3.4 lethal concentration low value
  • 4 Determination of toxicity
  • 4.1 General
  • 4.2 Test method
  • 4.3 Calculation method
  • Annex A
  • Annex B
  • Bibliography

Introduction

ISO 5145 specifies the dimensions of different valve outlets for different compatible gas groups. These compatible gas groups are determined according to practical criteria defined in ISO 14456. These criteria are based on certain physical, chemical, toxic and corrosive properties of the gases. In particular, the tissue corrosiveness is considered in this document. The aim of this document is to assign for each gas a classification category that takes into account the toxicity by inhalation of the gas. For gas mixtures containing toxic components a calculation based on the method specified in the GHS is proposed.

Since the publication of the first edition of ISO 10298, this International Standard has been used for other purposes than the selection of cylinder valve outlets, e.g. providing toxicity data for the classification of gas and gas mixtures according to the international transport regulations and according to the classification of dangerous substances regulations, which since 2003 is under the umbrella of the Globally Harmonized System (GHS).

oSIST prEN ISO 10298:2026

oSIST prEN ISO 10298:2026 DRAFT International Standard ISO/DIS 10298:2025(en) Gas cylinders — Gases and gas mixtures — Determination of toxicity for the selection of cylinder valve outlets

1 Scope

This document lists the best available acute-toxicity data of gases taken from a search of the current literature to allow the classification of gases and gas mixtures for toxicity by inhalation.

2 Normative references

There are no normative references in this document.

3 Terms and definitions

For the purposes of this document, the terms and definitions given in ISO 10286 and the following apply. ISO and IEC maintain terminology databases for use in standardization at the following addresses:

  • ISO Online browsing platform: available at https:// www .iso .org/ obp
  • IEC Electropedia: available at https:// www .electropedia .org/

3.1 lethal concentration 50

LC

concentration of a substance in air exposure to which, for a specified length of time, it is expected to cause the death of 50 % of the entire defined experimental animal population after a defined time period Note 1 to entry: See Annex A for the selection of this LC value.

3.2 toxicity level

level of toxicity of gases and gas mixtures Note 1 to entry: In ISO 14456, the toxicity level is divided into three groups:

  • Subdivision 1: non toxic [LC > 5 000 ppm (volume fraction)]
  • Subdivision 2: toxic [200 ppm (volume fraction) < LC ≤ 5 000 ppm (volume fraction)]
  • Subdivision 3: very toxic [LC ≤ 200 ppm (volume fraction)]

These subdivisions are sometimes used in transport regulations. where LC values correspond to 1 h exposure to gas;

ppm (volume fraction) indicates parts per million, by volume.

Note 2 to entry: In the GHS, the inhalation toxicity levels are:

oSIST prEN ISO 10298:2026 ISO/DIS 10298:2025(en) Category 1: Fatal if inhaled 0 ppm < LC ≤ 100 ppm (volume fraction)

Category 2: Fatal if inhaled 100 ppm (volume fraction) < LC ≤ 500 ppm (volume fraction)

Category 3: Toxic if inhaled 500 ppm (volume fraction) < LC ≤ 2 500 ppm (volume fraction)

Category 4: Harmful if inhaled 2 500 ppm (volume fraction) < LC ≤ 20 000 ppm (volume fraction)

Note 3 to entry: In GHS, the LC values correspond to 4 hours exposure. Consequently, the LC50 values given in

Annex B (see 4.2.2) need to be divided by 2 (i.e. 41/ ). The reasoning behind the division by 2 is given in A.2.

3.3 lethal dose 50

LD

amount of a material, given all at once, which causes the death of 50 % of a group of test animals

3.4 lethal concentration low value

LC LO lowest concentration of a substance in air, other than the LC , which was reported in the original reference

paper as having caused death in humans or animals

4 Determination of toxicity

4.1 General

Toxicity may be determined through a test method (4.2) for gas mixtures where the data for the components exist, or through a calculation method (4.3).

For reasons of animal welfare, inhalation toxicity tests geared only for the classification of gas mixtures should be avoided if the toxicity of each of the components is available. In this case, toxicity is determined in accordance with 4.3.

4.2 Test method

4.2.1 Test procedure

When new toxicity data are being considered for inclusion in this document, an internationally recognized [43] test method such as OECD TG 403 should be used.

NOTE For this document, LC is equivalent to 1 h exposure to albino rats.

4.2.2 Results for pure gases

The toxicity of pure gases is listed in Annex B, in which LC values correspond to 1 h exposure. Some of

these values have been estimated in accordance with Annex A.

4.3 Calculation method

The LC value of a gas mixture is calculated using Formula 1:

LC = (1)

C

LC 50i where C is the mole fraction of the ith toxic component present in the gas mixture;

LC is the lethal concentration of the ith toxic component [LC < 5 000 ppm (by volume)]. 50i 50

oSIST prEN ISO 10298:2026 ISO/DIS 10298:2025(en) After the LC of the gas mixture has been calculated, this mixture is classified in accordance with 3.2.

NOTE Potential synergistic effects are not considered in Formula 1.

oSIST prEN ISO 10298:2026 ISO/DIS 10298:2025(en)

Annex A

(informative)

Selection of an LC value for a particular gas

A.1 General When collecting data from the open literature on the acute inhalation toxicity of gases, some difficulties are experienced. For example, taking into account the very early years of publication, one cannot expect to get results of standardized tests. Moreover, data from reporting sources have to be validated with respect to their details in handling and summarizing information. Furthermore, there is a lack of information on inhalation toxicity for several gases. Thus, particular attention is needed to incorporate all the available facts to complete the toxicological characteristics of gases.

A.2 Time adjustment In inhalation toxicity tests, the dose-response relationship can be described by Formula A.1:

W = c ⋅ t (A.1) where W is a constant which is specific for any given effect, e.g. the deaths of 50 % of the animals exposed; c ⋅ t is the applied dose expressed as the product of concentration and exposure time. This equation, called Haber's rule, is applicable as long as the biological half-life of the substance in question is reasonably longer than the exposure time.

For gases and vapours with appreciable rates of detoxification or excretion over the time in question, it was found that the relationship between concentration and time is better described by Formula A.2. 0,5 W = c ⋅ t (A.2) When extrapolating from 4 h to 1 h, Formula A.2 predicts lower LC values than does Haber's rule. To be on

the safe side, this principle was applied by the UN Transport Recommendations in adopting the conversion factor 2 (i.e. 41/ ) to allow classification of materials on the basis of 1 h LC data. On the other hand,

Haber's rule predicts a lower LC when going from a 1-h to a 4-h LC . To make use of all the available data 50 50 on acute inhalation toxicity under the different exposure schemes, a more generalized version was applied. Using 1 h as the point of reference, - going up from shorter periods, linear extrapolation was preferred; - coming down from longer periods, the conversion factor xhh/1 was used. However, test results for a period less than 0,5 h were not used, as this was deemed unreliable. A.3 Choice of animal Since data on humans, if available, are usually not sufficient to derive any dose-response relationship, laboratory animals are used to investigate the toxicity of substances on warm-blooded animals. Unless there are counter indications, such as extraordinarily high or low susceptibility of the rat compared to other animals or humans, the rat is the preferred species in the most common toxicity tests. Therefore,

oSIST prEN ISO 10298:2026 ISO/DIS 10298:2025(en) LC data in rats are the most likely to be found. If they are missing, data from animals close to the rat in

body weight are evaluated.

A.4 Adjustment for effects Instead of LC , often the term LC is found in the reporting literature and in databases. 50 LO Unfortunately, the use of this term is not consistent enough to make any assumptions as to whether the LC is below or above that value. Nevertheless, it seems reasonable to make the same use of the LC as if it 50 LO were information about an approximate lethal concentration (ALC). For the classification of gases, no higher precision is required, but the calculation formula for gas mixtures requires a definite LC value to be set.

Another LC value has been taken as LC when additional information proved it plausible to do so.

A.5 Read across Some substances had to be characterized as analogous to chemically related structures with known physiological properties. Structure-activity relationships have been taken into consideration as far as possible. Moreover, in several instances, the toxicological impact on the respiratory tract is based on fundamental reactions such as the hydrolysis of different gases in the presence of moisture leading to the same reactive principle.

A.6 Other routes of application This route may only be used as a very last option.

Sometimes the inhalation toxicity of volatile liquids has to be assessed on the basis of other parenteral, especially intraperitoneal (i.p.), LD values. There is a good correlation between the LC and LD i.p. as 50 50 50 far as systemically active substances are concerned. Taking toxic pesticides as an example, it could be shown that an LD i.p. corresponds in aerosol studies by far and large with the same body weight-related dose

inhaled by rats during a 4-h period. For instance, an LD i.p. of 100 mg/kg can be assumed to be equivalent

to a 4 h-LC of about 1 mg/litre air.

...