EN ISO 5167-6:2019
(Main)Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 6: Wedge meters (ISO 5167-6:2019)
Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 6: Wedge meters (ISO 5167-6:2019)
This document specifies the geometry and method of use (installation and operating conditions) of wedge meters when they are inserted in a conduit running full to determine the flow rate of the fluid flowing in the conduit.
NOTE 1 As the uncertainty of an uncalibrated wedge meter can be too large for a particular application, it could be deemed essential to calibrate the flow meter according to Clause 7.
This document gives requirements for calibration which, if applied, are for use over the calibrated Reynolds number range. Clause 7 could also be useful guidance for calibration of meters of similar design but which fall outside the scope of this document.
It also provides background information for calculating the flow rate and is applicable in conjunction with the requirements given in ISO 5167‑1.
This document is applicable only to wedge meters in which the flow remains subsonic throughout the measuring section and where the fluid can be considered as single-phase. Uncalibrated wedge meters can only be used within specified limits of pipe size, roughness, beta (or wedge ratio) and Reynolds number. It is not applicable to the measurement of pulsating flow. It does not cover the use of uncalibrated wedge meters in pipes whose internal diameter is less than 50 mm or more than 600 mm, or where the pipe Reynolds numbers are below 1 × 104.
NOTE 2 A wedge meter has a primary element which consists of a wedge-shaped restriction of a specific geometry. Alternative designs of wedge meters are available; however, at the time of writing there is insufficient data to fully characterize these devices, and therefore these meters are calibrated in accordance with Clause 7.
Durchflussmessung von Fluiden mit Drosselgeräten in voll durchströmten Leitungen mit Kreisquerschnitt - Teil 6: Keil-Durchflussmesser (ISO 5167-6:2019)
Dieses Dokument legt die Geometrie und Anwendungsverfahren (Einbau und Betriebsbedingungen) von in voll durchströmten Leitungen eingesetzten Keil Durchflussmessern fest, um den Durchfluss der Fluid-strömung in der Leitung zu bestimmen.
ANMERKUNG 1 Da die Unsicherheit eines nicht kalibrierten Keil Durchflussmessers für eine bestimmte Anwendung zu groß sein kann, könnte es als erforderlich angesehen werden, den Durchflussmesser nach Abschnitt 7 zu kalibrieren.
Dieses Dokument enthält Anforderungen an die Kalibrierung, die, wenn sie angewendet werden, für den kalibrierten Bereich der Reynoldszahlen gelten. Abschnitt 7 könnte auch ein nützlicher Leitfaden für die Kalibrierung von Durchflussmessern ähnlicher Ausführung sein, die jedoch nicht in den Anwendungsbereich des vorliegenden Dokuments fallen.
Es gibt auch Hintergrundinformationen für die Durchflussberechnung und gilt in Verbindung mit den in ISO 5167 1 festgelegten Anforderungen.
Dieses Dokument ist nur auf Keil Durchflussmesser anwendbar, in denen die Strömung in allen Messquer-schnitten im Unterschallbereich bleibt und das Fluid als einphasig betrachtet werden kann. Nicht kalibrierte Keil Durchflussmesser können nur innerhalb festgelegter Grenzen von Rohrweite, Rauheit β (oder Keilver¬hältnis) und Reynoldszahl angewendet werden. Es ist nicht für die Messung von pulsierender Strömung anwendbar. Er behandelt nicht die Anwendung von nicht kalibrierten Keil Durchflussmessern bei Rohren, deren Innendurchmesser geringer als 50 mm oder größer als 600 mm ist, oder wenn die Rohr Reynoldszahlen unter 1 × 104 liegen.
ANMERKUNG 2 Ein Keil Durchflussmesser verfügt über ein Primärelement, das aus einer keilförmigen Verengung mit spezifischer Geometrie besteht. Es stehen alternative Ausführungen von Keil Durchflussmessern zur Verfügung; zum Zeitpunkt der Erstellung der Norm gibt es jedoch nicht genügend Daten, um diese Geräte vollständig zu beschreiben, und deshalb werden diese Durchflussmesser nach Abschnitt 7 kalibriert.
Mesure de débit des fluides au moyen d'appareils déprimogènes insérés dans des conduites en charge de section circulaire - Partie 6: Débitmètres à coin (ISO 5167-6:2019)
Le présent document spécifie la géométrie et le mode d'emploi (conditions d'installation et d'utilisation) de débitmètres à coin insérés dans une conduite en charge dans le but de déterminer le débit du fluide s'écoulant dans cette conduite.
NOTE 1 Étant donné que l'incertitude d'un débitmètre à coin non étalonné risque d'être trop grande pour une application particulière, l'étalonnage du débitmètre conformément à l'Article 7 pourrait être considéré comme essentiel.
Le présent document fournit des exigences relatives à l'étalonnage, qui, si elles sont appliquées, sont destinées à être utilisées sur la plage des nombres de Reynolds qui a été étalonnée. L'Article 7 peut également fournir des préconisations utiles pour l'étalonnage des appareils de mesure de conception similaire, mais qui n'entrent pas dans le domaine d'application du présent document.
Il fournit également des informations de fond nécessaires au calcul du débit et il est applicable conjointement avec les exigences stipulées dans l'ISO 5167-1.
Le présent document est applicable uniquement aux débitmètres à coin pour lesquels l'écoulement reste subsonique dans tout le tronçon de mesure et où le fluide peut être considéré comme monophasique. Les débitmètres à coin non étalonnés ne peuvent être utilisés que dans des limites spécifiées de diamètre de conduite, de rugosité, de valeur de bêta (ou rapport du coin) et de nombre de Reynolds. Il n'est pas applicable au mesurage d'un écoulement pulsé. Il ne couvre pas l'utilisation de débitmètres à coin non étalonnés dans des conduites dont le diamètre intérieur est inférieur à 50 mm ou supérieur à 600 mm, ni les cas où les nombres de Reynolds rapportés à la tuyauterie sont inférieurs à 1 × 104.
NOTE 2 Un débitmètre à coin comporte un élément primaire composé d'une restriction en forme de coin de géométrie spécifique. D'autres conceptions de débitmètres à coin sont possibles; cependant, au moment de la rédaction du présent document les données permettant de caractériser complètement ces appareils étaient insuffisantes et ces derniers sont donc étalonnés conformément à l'Article 7.
Merjenje pretoka fluida na osnovi tlačne razlike, povzročene z napravo, vstavljeno v polno zapolnjen vod s krožnim prerezom - 6. del: Merilniki klinov (ISO 5167-6:2019)
Ta standard določa geometrijo in metodo uporabe (namestitev in pogoji delovanja) merilnikov klinov, kadar so ti vstavljeni v polno zapolnjen vod za ugotavljanje stopnje pretoka fluida skozi vod. Ta dokument podaja zahteve za umerjanje, ki se v ustreznem primeru uporabljajo v območju umerjanja Reynoldsovega števila. Točko 7 je mogoče uporabiti kot koristno vodilo za umerjanje merilnikov podobne zasnove, ki ne spadajo na področje uporabe tega dokumenta. Prav tako podaja dodatne informacije za izračun stopnje pretoka in se uporablja skupaj z zahtevami iz standarda ISO 5167-1. Ta dokument se uporablja samo za merilnike klinov, ki v predelu merjenja ohranjajo podzvočen pretok in pri katerih se lahko fluid obravnava kot enofazen. Neumerjeni merilniki klinov se lahko uporabljajo samo v okviru določenih omejitev glede velikosti cevi, hrapavosti, koeficienta beta (ali razmerja klinov) in Reynoldsovega števila. Ne uporablja se za merjenje utripajočega pretoka. Ne obravnava uporabe neumerjenih merilnikov klinov v ceveh z notranjim premerom pod 50 mm ali nad 600 mm, ali pri katerih so Reynoldsova števila za cevi manj kot 1 × 104.
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
01-december-2019
Merjenje pretoka fluida na osnovi tlačne razlike, povzročene z napravo, vstavljeno
v polno zapolnjen vod s krožnim prerezom - 6. del: Merilniki klinov (ISO 5167-
6:2019)
Measurement of fluid flow by means of pressure differential devices inserted in circular
cross-section conduits running full - Part 6: Wedge meters (ISO 5167-6:2019)
Durchflussmessung von Fluiden mit Drosselgeräten in voll durchströmten Leitungen mit
Kreisquerschnitt - Teil 6: Keil-Durchflussmesser (ISO 5167-6:2019)
Mesure de débit des fluides au moyen d'appareils déprimogènes insérés dans des
conduites en charge de section circulaire - Partie 6: Débitmètres à coin (ISO 5167-
6:2019)
Ta slovenski standard je istoveten z: EN ISO 5167-6:2019
ICS:
17.120.10 Pretok v zaprtih vodih Flow in closed conduits
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EN ISO 5167-6
EUROPEAN STANDARD
NORME EUROPÉENNE
October 2019
EUROPÄISCHE NORM
ICS 17.120.10
English Version
Measurement of fluid flow by means of pressure
differential devices inserted in circular cross-section
conduits running full - Part 6: Wedge meters (ISO 5167-
6:2019)
Mesure de débit des fluides au moyen d'appareils Durchflussmessung von Fluiden mit Drosselgeräten in
déprimogènes insérés dans des conduites en charge de voll durchströmten Leitungen mit Kreisquerschnitt -
section circulaire - Partie 6: Débitmètres à coin (ISO Teil 6: Keil-Durchflussmesser (ISO 5167-6:2019)
5167-6:2019)
This European Standard was approved by CEN on 23 September 2019.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this
European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references
concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN
member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by
translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management
Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and
United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2019 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN ISO 5167-6:2019 E
worldwide for CEN national Members.
Contents Page
European foreword . 3
European foreword
The text of ISO 5167-6:2019 has been prepared by Technical Committee ISO/TC 30 "Measurement of
fluid flow in closed conduits” of the International Organization for Standardization (ISO) and has been
taken over as EN ISO 5167-6:2019 by CCMC.
This European Standard shall be given the status of a national standard, either by publication of an
identical text or by endorsement, at the latest by April 2020, and conflicting national standards shall be
withdrawn at the latest by April 2020.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN shall not be held responsible for identifying any or all such patent rights.
According to the CEN-CENELEC Internal Regulations, the national standards organizations of the
following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria,
Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland,
Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Republic of
North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the
United Kingdom.
Endorsement notice
The text of ISO 5167-6:2019 has been approved by CEN as EN ISO 5167-6:2019 without any
modification.
INTERNATIONAL ISO
STANDARD 5167-6
First edition
2019-02
Measurement of fluid flow by means of
pressure differential devices inserted
in circular cross-section conduits
running full —
Part 6:
Wedge meters
Mesure de débit des fluides au moyen d'appareils déprimogènes
insérés dans des conduites en charge de section circulaire —
Partie 6: Débitmètres à coin
Reference number
ISO 5167-6:2019(E)
©
ISO 2019
ISO 5167-6:2019(E)
© ISO 2019
All rights reserved. Unless otherwise specified, or required in the context of its implementation, no part of this publication may
be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting
on the internet or an intranet, without prior written permission. Permission can be requested from either ISO at the address
below or ISO’s member body in the country of the requester.
ISO copyright office
CP 401 • Ch. de Blandonnet 8
CH-1214 Vernier, Geneva
Phone: +41 22 749 01 11
Fax: +41 22 749 09 47
Email: copyright@iso.org
Website: www.iso.org
Published in Switzerland
ii © ISO 2019 – All rights reserved
ISO 5167-6:2019(E)
Contents Page
Foreword .iv
Introduction .v
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 2
4 Principles of the method of measurement and computation . 2
5 Wedge meters . 3
5.1 Field of application . 3
5.2 General shape . 4
5.3 Material and manufacture . 5
5.4 Pressure tappings . 5
5.5 Discharge coefficient, C .6
5.5.1 Limits of use . 6
5.5.2 Discharge coefficient of the wedge meter . 6
5.6 Expansibility [expansion] factor, ε . 7
5.7 Uncertainty of the discharge coefficient, C .7
5.8 Uncertainty of the expansibility [expansion] factor, ε . 7
5.9 Pressure loss . 7
6 Installation requirements. 8
6.1 General . 8
6.2 Minimum upstream and downstream straight lengths for installations between
various fittings and the wedge meter . 8
6.3 Additional specific installation requirements for wedge meters . 8
6.3.1 Circularity and cylindricality of pipes upstream and downstream of the
wedge meter . 8
6.3.2 Roughness of the upstream and downstream pipe . 9
6.3.3 Positioning of a thermowell . 9
6.3.4 Bidirectional wedge meters . 9
7 Flow calibration of wedge meters . 9
7.1 General . 9
7.2 Test facility . 9
7.3 Meter installation. 9
7.4 Design of the test programme .10
7.5 Reporting the calibration results .10
7.6 Uncertainty analysis of the calibration .10
7.6.1 General.10
7.6.2 Uncertainty of the test facility .10
7.6.3 Uncertainty of the wedge meter .10
Annex A (informative) Table of expansibility [expansion] factor .11
Annex B (informative) Use of Kd parameter .12
Bibliography .13
ISO 5167-6:2019(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out
through ISO technical committees. Each member body interested in a subject for which a technical
committee has been established has the right to be represented on that committee. International
organizations, governmental and non-governmental, in liaison with ISO, also take part in the work.
ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of
electrotechnical standardization.
The procedures used to develop this document and those intended for its further maintenance are
described in the ISO/IEC Directives, Part 1. In particular the diffe
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.