EN IEC 60704-2-1:2026
(Main)Household and similar electrical appliances - Test code for the determination of airborne acoustical noise - Part 2-1: Particular requirements for dry vacuum cleaners
- Abstract
Addition:
This document specifies the determination of airborne acoustical noise of mains operated and cordless dry vacuum cleaners including their accessories and docking stations for household use or under conditions similar to those in households.
For wet and dry vacuum cleaners, the dry cleaning function applies. The wet cleaning function is measured in accordance with IEC 60704-2-20.
NOTE 101 Particular requirements for floor cleaning robots are specified in IEC 60704-2-171.
This document describes the determination of the noise emission of dry vacuum cleaners under normal operating conditions on carpet and hard floor in accordance with IEC 62885-2:—,4.62.
- Status
- Published
- Publication Date
- 27-Aug-2026
- Technical Committee
- CLC/TC 59X - Performance of household and similar electrical appliances
- Current Stage
- 6060 - Document made available - Publishing
- Start Date
- 28-Aug-2026
- Due Date
- 31-Dec-2025
- Completion Date
- 31-Dec-2025
EN IEC 60704-2-1:2026 is a CENELEC European Standard for measuring airborne acoustical noise from dry vacuum cleaners. It specifies the test code for mains-operated and cordless dry vacuum cleaners, including accessories and docking stations, so results can be measured and reported in a consistent way for household and similar use.
The document is the European adoption of IEC 60704-2-1:2026 without modification. It is intended to be read together with the general requirements in EN IEC 60704-1:2021.
What does EN IEC 60704-2-1:2026 specify?
EN IEC 60704-2-1:2026 specifies how to determine the airborne acoustical noise of dry vacuum cleaners on carpet and hard floor. It covers appliances for household use or similar use, including accessories and docking stations.
The document is organized into clauses on scope, normative references, terms and definitions, measurement methods and acoustical environments, instrumentation, operation and location of the appliance under test, sound pressure level measurement, calculation of sound pressure and sound power levels, and reporting. Annex ZA gives the normative references and their European publications, and Annex A is titled Standard test table.
What are the key requirements of EN IEC 60704-2-1:2026?
EN IEC 60704-2-1:2026 sets the test conditions that make noise results comparable between laboratories. The main practical point is that the appliance, the surface, the settings, and the measurement method all have to match the document closely.
Scope and test surfaces
The standard applies to mains-operated and cordless dry vacuum cleaners, including accessories and docking stations. For wet and dry vacuum cleaners, the dry cleaning function is tested here, while the wet cleaning function is covered by IEC 60704-2-20.
Noise is measured under normal operating conditions on carpet and hard floor in line with IEC 62885-2. For a product designed for both floor types, results are determined separately for carpet and hard floor, so the report can reflect real use.
Measurement methods and environment
Clause 4 allows both direct and comparison methods, and the document points to ISO 3743-1, ISO 3743-2, and ISO 3744 as acceptable measurement environments. If the source emits audible discrete tones, extra microphone or source positions may be needed. In practice, this means the laboratory has to watch for tones that can change the measured spread of results.
If an operator is needed during the test, the operator is treated as part of the test environment. The same operator position is then used during the reverberation time or comparison measurement, which helps keep the setup repeatable.
Preparation, operation, and settings
Clause 6 requires specific pre-conditioning. New mains-operated cleaners are run with unrestricted air flow before first test, new cordless cleaners are fully charged and then discharged in the test setting, and docking stations are run through repeated cycles before noise testing.
The standard also fixes how the appliance is set up for testing. Manufacturers' instructions are followed first; if they are unclear, visible product markings are used; if the setting is still ambiguous, the manufacturer is contacted; and if that still does not resolve it, maximum continuous airflow is used. For a test lab, this means the chosen setting must be defensible and fully recorded.
Surface-specific placement
Clause 6 distinguishes carpet and hard floor placement. On carpet, the appliance is centered on a standard Wilton test carpet, with the pile direction and handle position controlled. Active nozzles are tested on glued carpet to avoid noise from carpet vibration, while passive nozzles are not glued.
On hard floor, the appliance is centered on a standard hard floor, and the document gives surface properties and alternatives such as marble or similar stone plates when needed. Docking stations are placed in the center of the test area on the standard hard floor. These rules matter because small changes in placement can change the measured noise.
Measurement, calculation, and reporting
Clause 7 uses a 30 s time-average for the A-weighted sound pressure level of a dry vacuum cleaner. For docking stations, the highest A-weighted time-averaged sound pressure level over 2.5 s is measured across operating modes.
Clause 8 states that the final results for dry vacuum cleaners are the sound power levels for carpet and hard floor, determined separately, and averaged energetically if there are multiple measurements. Clause 10 requires reporting of the cleaning head type, carpet version and batch, hard floor type, cleaning head settings, and the state of openings used to reduce suction power.
What terms does EN IEC 60704-2-1:2026 define?
EN IEC 60704-2-1:2026 defines several terms that are central to the test setup.
- Dry vacuum cleaner - an electrically operated appliance that removes dry material by air flow and returns cleaned air to the ambient air.
- Wet and dry vacuum cleaner - an appliance designed to remove liquid in addition to dry material.
- Cleaning head - the nozzle, brush, power nozzle, or similar part that contacts the surface being cleaned.
- Active nozzle - a cleaning head with a driven agitation device to help remove dirt.
- Standard Wilton test carpet - the specified carpet used when measuring on carpet.
- Standard hard floor - the hard floor used when measuring on hard floor.
- Docking station - a base unit that can charge, remove dust, process data, or provide other support functions.
Who uses EN IEC 60704-2-1:2026?
EN IEC 60704-2-1:2026 is used by appliance manufacturers, test laboratories, and certification bodies working with household and similar electrical appliances. Quality managers and buyers use it when they need a consistent noise test method for dry vacuum cleaners.
It is especially relevant to the surface-cleaning appliance sector, including products with carpet and hard floor modes, cordless products, and vacuum cleaners with docking stations. It is also useful for technical committees and national committees that need a harmonized European test code.
What changed in EN IEC 60704-2-1:2026 from the previous edition?
EN IEC 60704-2-1:2026 is the fifth edition and replaces the 2020 edition. The foreword states that it is a technical revision.
The listed significant changes are:
- alignment with IEC 60704-1:2021
- added attention to consumer-relevant testing aspects
- improved robustness of the standard and closing of potential loopholes
- enlarged scope to include noise measurement on docking stations
Which standards are used with EN IEC 60704-2-1:2026?
EN IEC 60704-2-1:2026 is used together with several referenced standards and companion parts.
- EN IEC 60704-1:2021 - the general requirements for airborne acoustical noise test code; this part modifies and supplements it.
- IEC 60704-2-20 / EN IEC 60704-2-20 - used for the wet cleaning function of wet and dry vacuum cleaners.
- IEC TS 62885-1 - provides general requirements on test material and test equipment, including the standard Wilton test carpet specification.
- IEC 62885-2 / EN IEC 62885-2 - gives performance measurement methods for dry vacuum cleaners and is used for the operating conditions and definitions.
- IEC 60704-3 - used when determining and verifying declared noise emission values.
- ISO 3743-1, ISO 3743-2, ISO 3744 - provide the measurement environment methods referenced for acoustical testing.
What does the EN IEC 60704-2-1:2026 document contain?
EN IEC 60704-2-1:2026 contains the test code structure, the required measurement environments, and the operating procedures for dry vacuum cleaners. It also includes the setup rules for carpet and hard floor testing, the treatment of cordless appliances and docking stations, and the calculation and reporting rules.
The document includes figures showing the placement of appliances with a directly connected cleaning head and with a hose and connecting tube. It also includes tables for standard deviations on carpets and hard floors, and for declaration and verification values used with noise emission reporting.
Relations
- Effective Date
- 18-Jul-2023
- Effective Date
- 07-Jul-2026
- Effective Date
- 07-Jul-2026
- Effective Date
- 01-Sep-2026
- Effective Date
- 01-Sep-2026
- Effective Date
- 01-Sep-2026
- Effective Date
- 01-Sep-2026
Get Certified
Connect with accredited certification bodies for this standard
BSMI (Bureau of Standards, Metrology and Inspection)
Taiwan's standards and inspection authority.
Sponsored listings
Frequently Asked Questions
EN IEC 60704-2-1:2026 is a standard published by CLC. Its full title is "Household and similar electrical appliances - Test code for the determination of airborne acoustical noise - Part 2-1: Particular requirements for dry vacuum cleaners". This standard covers: Addition: This document specifies the determination of airborne acoustical noise of mains operated and cordless dry vacuum cleaners including their accessories and docking stations for household use or under conditions similar to those in households. For wet and dry vacuum cleaners, the dry cleaning function applies. The wet cleaning function is measured in accordance with IEC 60704-2-20. NOTE 101 Particular requirements for floor cleaning robots are specified in IEC 60704-2-171. This document describes the determination of the noise emission of dry vacuum cleaners under normal operating conditions on carpet and hard floor in accordance with IEC 62885-2:—,4.62.
Addition: This document specifies the determination of airborne acoustical noise of mains operated and cordless dry vacuum cleaners including their accessories and docking stations for household use or under conditions similar to those in households. For wet and dry vacuum cleaners, the dry cleaning function applies. The wet cleaning function is measured in accordance with IEC 60704-2-20. NOTE 101 Particular requirements for floor cleaning robots are specified in IEC 60704-2-171. This document describes the determination of the noise emission of dry vacuum cleaners under normal operating conditions on carpet and hard floor in accordance with IEC 62885-2:—,4.62.
EN IEC 60704-2-1:2026 is classified under the following ICS (International Classification for Standards) categories: 17.140.20 - Noise emitted by machines and equipment; 97.080 - Cleaning appliances. The ICS classification helps identify the subject area and facilitates finding related standards.
EN IEC 60704-2-1:2026 has the following relationships with other standards: It is inter standard links to EN IEC 60704-2-1:2020, EN IEC 60704-2-20:2026, IEC TS 62885-1:2016, EN IEC 60704-1:2021, EN 60312-1:2013, EN 60312-1:2017, EN 60704-3:2019. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN IEC 60704-2-1:2026 is associated with the following European legislation: EU Directives/Regulations: 666/2013. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
EN IEC 60704-2-1:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Measurement methods and acoustical environments
- 4.2 Direct method
- 4.3 Comparison method
- 4.4 Acoustical environment
- 4.5 Measurement uncertainties
- 5 Instrumentation
- 5.1 Instrumentation for measuring acoustical data
- 6 Operation and location of appliances under test
- 6.1 Equipping and pre-conditioning of appliances
- 6.2 Supply of electric energy and of water or gas
- 6.4 Loading and operating of appliances during tests
- 6.5 Location and mounting of appliances
- 7 Measurement of sound pressure levels
- 7.4 Measurements
- 8 Calculation of sound pressure and sound power levels
- 10 Information to be reported
- 10.3 Test conditions for the appliance
- Annex A
- Bibliography
INTRODUCTION The measuring conditions specified in this document provide for sufficient accuracy in determining the noise emitted and comparing the results of measurements taken by different laboratories, whilst simulating as far as possible the practical use of dry vacuum cleaners. It is recommended to consider the determination of noise levels as part of a comprehensive testing procedure covering many aspects of properties and performance of household vacuum cleaners.
NOTE As stated in the introduction to IEC 60704-1, this test code is concerned with airborne noise only.
SIST EN IEC 60704-2-1:2026
1 Scope
Addition:
This document specifies the determination of airborne acoustical noise of mains operated and cordless dry vacuum cleaners including their accessories and docking stations for household use or under conditions similar to those in households.
For wet and dry vacuum cleaners, the dry cleaning function applies. The wet cleaning function is measured in accordance with IEC 60704-2-20.
NOTE 101 Particular requirements for floor cleaning robots are specified in IEC 60704-2-17 . This document describes the determination of the noise emission of dry vacuum cleaners under normal operating conditions on carpet and hard floor in accordance with IEC 62885-2:—,
4.6 .
2 Normative references
Addition:
IEC 60704-2-20, Household and similar electrical appliances - Test code for the determination of airborne acoustical noise - Part 2-20: Particular requirements for wet hard floor cleaning appliances IEC TS 62885-1, Surface cleaning appliances - Part 1: General requirements on test material and test equipment
IEC 62885-2:—, Surface cleaning appliances - Part 2: Dry vacuum cleaners for household and similar use - Methods for measuring the performance
3 Terms and definitions
Addition:
3.101 dry vacuum cleaner electrically operated appliance that removes dry material (for example, dust, fibre, threads, and debris) from the surface to be cleaned by an air flow created by a vacuum developed within the unit, the removed material being separated in the appliance and the cleaned suction air being returned to the ambient air [SOURCE: IEC 62885-2: —, 3.8] 3.102 wet and dry vacuum cleaner appliance designed to remove liquid in combination with the functionality of a dry vacuum cleaner
Under preparation. Stage at the date of publication: IEC/CDV 60704-2-17:2026.
Under preparation. Stage at the date of publication: IEC/FDIS 62885-2:2026.
SIST EN IEC 60704-2-1:2026
3.103 cleaning head plain nozzle or brush attached to a connecting tube, or a power nozzle, separate or part of the cleaner housing, and that part of a dry vacuum cleaner which is applied to a surface to be cleaned [SOURCE: IEC 62885-2: —, 3.3] 3.104 active nozzle cleaning head provided with a driven agitation device to assist dirt removal Note 1 to entry: The agitation device can be driven by an incorporated electric motor (motorized nozzle), an incorporated turbine powered by the air flow (air-turbine nozzle) or an incorporated friction or gear mechanism actuated by moving the cleaning head over the surface to be cleaned (mechanical nozzle). [SOURCE: IEC 62885-2: —, 3.2] 3.105 standard Wilton test carpet Wilton carpet on which the dry vacuum cleaner and its cleaning head is placed for the measurement Note 1 to entry: The specification of the standard Wilton test carpet can be found in IEC TS 62885-1. 3.106 standard hard floor hard floor on which the dry vacuum cleaner and its cleaning head is placed for the measurement 3.107 docking station base unit unit that can provide manual or automatic battery charging facilities, dust removal from the dry vacuum cleaner, data processing facility or other support functions
4 Measurement methods and acoustical environments
4.2 Direct method
Addition:
If audible discrete tones are present in the noise emitted by the source, the estimated standard deviation of the measured sound pressure levels in the special reverberation room can increase. In such cases, additional microphone positions or source positions can be necessary, as specified in ISO 3743-2.
If an operator is necessary, it is considered as part of the test environment. Therefore, the operator shall be present also during the reverberation time measurement with the RSS. The position of the operator shall be approximately at the same position as in the measurement with the test sample.
SIST EN IEC 60704-2-1:2026
4.3 Comparison method
Addition:
If audible discrete tones are present in the noise emitted by the source, the estimated standard deviation of the measured sound pressure levels in the hard-walled test room or in the special reverberation room can increase. In such cases, additional microphone positions or source positions can be necessary, as specified in ISO 3743-1 or ISO 3743-2. If an operator is necessary, it is considered as part of the test environment. Therefore, the operator shall be present also during the comparison measurement with the RSS. The position of the operator shall be approximately at the same position as in the measurement with the test sample.
4.4 Acoustical environment
4.4.1 General requirements and criterion for adequacy of the test environment
Addition:
The methods specified in ISO 3743-1, ISO 3743-2 and ISO 3744 can be used for measuring noise emitted by electric vacuum cleaners.
4.5 Measurement uncertainties
4.5.2 Standard deviations on repeatability and reproducibility and standard
deviations related to declaration and verification Replacement:
For dry vacuum cleaners designed for cleaning carpets, the estimated values of standard deviations of sound power levels determined in accordance with this document are provided in Table 1.
Table 1 – Standard deviations of sound power levels determined on carpets Standard deviation (dB) σ (repeatability) σ (reproducibility) r R 0,3 0,8
For dry vacuum cleaners designed for cleaning hard floors, the estimated values of standard deviations of sound power levels determined in accordance with this document are provided in Table 2.
SIST EN IEC 60704-2-1:2026
Table 2 – Standard deviations of sound power levels determined on hard floors Standard deviation (dB) σ (repeatability) σ (reproducibility) r R 0,2 0,6
NOTE 101 The values in Table 1 and Table 2 are derived from the results of a round robin test (RRT) conducted in 2010/2011 with 4 different vacuum cleaners (passive and active) in 8 participating laboratories. NOTE 102 For docking stations, the standard deviations are under consideration. For the purpose of determining and verifying declared noise emission values for dry vacuum cleaners designed for cleaning carpets, in accordance with IEC 60704-3, the following values provided in Table 3 apply.
Table 3 – Standard deviations for declaration and verification for vacuum cleaners for carpets Standard deviation (dB) σ (production) σ (total) σ (reference) P t M 0,5 to 1,0 0,9 to 1,3 1,5
For the purpose of determining and verifying declared noise emission values for dry vacuum cleaners designed for cleaning hard floors, in accordance with IEC 60704-3, the following values provided in Table 4 apply.
Table 4 – Standard deviations for declaration and verification for vacuum cleaners for hard floors Standard deviation (dB) σ (production) σ (total) σ (reference) P t M 0,5 to 1,0 0,8 to 1,2 1,5
5 Instrumentation
5.1 Instrumentation for measuring acoustical data
Addition:
The use of windscreens is recommended. If necessary, the observed sound pressure level shall be corrected for changes in the microphone sensitivity, in accordance with the instructions accompanying the instrumentation.
SIST EN IEC 60704-2-1:2026
6 Operation and location of appliances under test
6.1 Equipping and pre-conditioning of appliances
6.1.1 Replacement:
The dry vacuum cleaner setting configurations, such as cleaning head and cleaning head setting, shall be used and adjusted in accordance with 6.4.2.
If the dry vacuum cleaner or docking station is designed to be used with disposable dust receptacles, it shall, prior to each measurement, be equipped with a new dust receptacle of the type recommended or supplied by the manufacturer of the dry vacuum cleaner. If the dry vacuum cleaner or docking station is provided with a reusable dust receptacle (as the sole original dust receptacle or as an enclosure for disposable dust receptacles), the dust receptacle and any additional filters removable without the aid of tools shall, prior to each measurement, be cleaned in accordance with the manufacturer's instructions until its mass is within 1 % or 2 g of its original mass, whichever is the lower. Docking stations shall be fitted for normal use in accordance with manufacturer's instructions. Audible signals (e.g. voice notification) shall be switched off if possible. 6.1.3 Replacement:
...



