R205-005:1997
(Main)Home and Building Electronic Systems (HBES) - Technical Report 5: Application requirements and market demands for infra-red in the context of HBES
- BACK
- 13-Nov-1997
- CLC/TC 205
Home and Building Electronic Systems (HBES) - Technical Report 5: Application requirements and market demands for infra-red in the context of HBES
CENELEC Report * D130/C016: Conversion into TR to be launched
Elektronski sistemi za stanovanja in stavbe (HBES) – Tehnično poročilo 5: Zahteve za infrardeče HBES in zahteve trga
General Information
Standards Content (Sample)
SLOVENSKI STANDARD
01-september-1998
(OHNWURQVNLVLVWHPL]DVWDQRYDQMDLQVWDYEH+%(6±7HKQLþQRSRURþLOR=DKWHYH
]DLQIUDUGHþH+%(6LQ]DKWHYHWUJD
Home and Building Electronic Systems (HBES) - Technical Report 5: Application
requirements and market demands for infra-red in the context of HBES
Ta slovenski standard je istoveten z: R205-005:1997
ICS:
97.120 Avtomatske krmilne naprave Automatic controls for
za dom household use
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
----------
...
This May Also Interest You
This document specifies systems and methods for the inspection and testing of installed optical fibre cabling designed in accordance with premises cabling standards including the EN 50173 series. The test methods refer to existing standards-based procedures where they exist.
- Draft86 pagesEnglish languagesale 10% offe-Library read for×1 day
- 11-Dec-2025
- 35.110
- CLC/TC 215
IEC 61169-74:2025, which is a Sectional Specification (SS), provides information and rules for the preparation of Detail Specifications (DS) for series HN RF coaxial connectors with screw coupling with a characteristic impedance of 50 Ω. This document prescribes mating face dimensions for high performance connectors (grade 2), dimensional details of standard test connectors (grade 0), gauging information and tests selected from IEC 61169-1, applicable to all Detail Specifications relating to series HN RF connectors. This document indicates recommended performance characteristics which are considered when writing a Detail Specification and it covers test schedules and inspection requirements for assessment levels M and H. The series HN connectors are intended to be used in microwave transmission systems and can be connected with all kinds of RF cables and microstrips. The operating frequency is up to 6 GHz.
- Draft21 pagesEnglish languagesale 10% offe-Library read for×1 day
- 11-Dec-2025
- 33.120.30
- CLC/SR 46F
2021-12-20: This prAA includes common mods to EN IEC 62841-2-20 (PR=75425)
DOW=DOR+48 months is applied to all parts in EN IEC 62841 series
- Amendment8 pagesEnglish languagesale 10% offe-Library read for×1 day
- 04-Dec-2025
- 25.140.20
- 2006/42/EC
- M/396
- CLC/TC 116
This document applies to railway signalling and telecommunication trackside equipment. This document does not cover signalling and telecommunication equipment mounted in vehicles; these are covered by EN 50155:2021. This document covers the type testing phases of the equipment for signal and telecommunication (S&T) systems (including power supply systems belonging to S&T), in order to ensure compliance with specified requirements already defined in the customer specifications or by the involved parties. In particular this document intends to define test requirements with related performance / acceptance criteria, considering only the environmental conditions stated by the EN 50125-3:2003, and considering the severities of the environmental parameters herein defined. Safety considerations are not covered by this document.
- Draft75 pagesEnglish languagesale 10% offe-Library read for×1 day
2021-12-20: This prAA includes common mods to EN IEC 62841-2-19 (PR=75430)
DOW=DOR+48 months is applied to all parts in EN IEC 62841 series
- Amendment9 pagesEnglish languagesale 10% offe-Library read for×1 day
- 04-Dec-2025
- 25.140.20
- 2006/42/EC
- M/396
- CLC/TC 116
This document applies to portable residual current devices (PRCDs) for household and similar uses, consisting of a plug, a residual current device (RCD) and one or more socket-outlets or a provision for connection. They do not incorporate overcurrent protection. They are intended for single- and two-phase systems for rated currents not exceeding 16 A for rated voltages not exceeding 250 V AC, or for rated current not exceeding 32 A for rated voltages not exceeding 130 V AC to earth. They are intended to provide protection against shock hazard in case of direct contact, in addition to the protection provided by the fixed installations for the circuit downstream. PRCDs have a rated residual operating current not exceeding 0,03 A. The plug and socket-outlet parts of a PRCD are covered by the national standard of the country where the PRCD is placed on the market. If no national requirements exist, IEC 60884 1 is used. This document applies to portable devices performing simultaneously the functions of detection of the residual current, of comparison of the value of this current with the residual operating value and of opening of the protected circuit when the residual current exceeds this value. PRCDs providing an additional function of detecting faults on the supply side with a defined behaviour in case of supply failures or miswiring (PRCD-S) are also covered by this document. PRCDs are not intended to be used as parts of fixed installations. Their connecting means can be plugs, socket-outlets, terminals or cords. NOTE 1 The requirements for PRCDs are in compliance with the general requirements of IEC 60755. PRCDs are essentially intended to be operated by ordinary persons and designed not to require maintenance. NOTE 2 An integral fuse is used, if necessary, for the relevant plug and socket-outlet system. The switching contacts of the PRCDs are not intended to provide isolation, as isolation can be ensured by disconnecting the plug. The requirements of this document apply for environmental conditions as defined in 7.1. Additional requirements can be necessary for PRCDs used in locations having more severe environmental conditions. PRCDs including batteries are not covered by this document. This document does not contain additional requirements for PRCDs without earthing contacts for which specific requirements can apply. This document can, however, be used as a guide for such devices which are intended to be used with Class II appliances only.
- Draft145 pagesEnglish languagesale 10% offe-Library read for×1 day
- 04-Dec-2025
- 29.120.01
- CLC/TC 23E
IEC 62841-2-22:2025 applies to hand-held cut-off machines fitted with - one bonded reinforced wheel of Type 41 or Type 42; or - one or more diamond cutting wheels with peripheral gaps, if any, • having no positive rake angle; and • not exceeding 10 mm for cut-off machines other than flush cutters, power cutters and wall chasers; and with - a rated no-load speed not exceeding a peripheral speed of the wheel of 100 m/s at rated capacity; and - a rated capacity not exceeding 430 mm. NOTE 101 An example of a permitted diamond cutting wheel construction is shown in Figure 106. These tools are intended to cut materials such as metals, concrete, masonry, glass and tile. This document does not apply to: - cut-off machines that can be converted to a grinder, sander or polisher, which are covered by IEC 62841-2-3; - circular saws which are covered by IEC 62841-2-5; and - die grinders and small rotary tools which are covered by IEC 62841-2-23; - tools intended to cut wood, except for utility cutters; - cut-off machines fitted with a bonded reinforced wheel of Type 42 with a diameter exceeding 230 mm. This document is to be used in conjunction with IEC 62841-1:2014.
- Draft58 pagesEnglish languagesale 10% offe-Library read for×1 day
- 04-Dec-2025
- 25.140.20
- 2006/42/EC
- M/396
- CLC/TC 116
- Draft10 pagesEnglish languagesale 10% offe-Library read for×1 day
- 04-Dec-2025
- 25.140.20
- 2006/42/EC
- M/396
- CLC/TC 116
This document applies to portable residual current devices (PRCDs) for household and similar uses, consisting of a plug, a residual current device (RCD) and one or more socket-outlets or a provision for connection. They do not incorporate overcurrent protection. They are intended for single- and two-phase systems for rated currents not exceeding 16 A for rated voltages not exceeding 250 V AC. They are intended to provide protection against shock hazard in case of direct contact, in addition to the protection provided by the fixed installations for the circuit downstream. PRCDs have a rated residual operating current not exceeding 0,03 A. The plug and socket-outlet parts of a PRCD are covered by the national standard of the country where the PRCD is placed on the market. This document applies to portable devices performing simultaneously the functions of detection of the residual current, of comparison of the value of this current with the residual operating value and of opening of the protected circuit when the residual current exceeds this value. PRCDs providing an additional function of detecting faults on the supply side with a defined behaviour in case of supply failures or miswiring (PRCD-S) are also covered by this document. PRCDs are not intended to be used as parts of fixed installations. Their connecting means can be plugs, socket-outlets, terminals or cords. NOTE 1 The requirements for PRCDs are in compliance with the general requirements of IEC 60755. PRCDs are essentially intended to be operated by ordinary persons and designed not to require maintenance. NOTE 2 An integral fuse is used, if necessary, for the relevant plug and socket-outlet system. The switching contacts of the PRCDs are not intended to provide isolation, as isolation can be ensured by disconnecting the plug. The requirements of this document apply for environmental conditions as defined in 7.1. Additional requirements can be necessary for PRCDs used in locations having more severe environmental conditions. PRCDs including batteries are not covered by this document. This document does not contain additional requirements for PRCDs without earthing contacts for which specific requirements can apply. This document can, however, be used as a guide for such devices which are intended to be used with Class II appliances only.
- Draft11 pagesEnglish languagesale 10% offe-Library read for×1 day
- 04-Dec-2025
- 29.120.01
- CLC/TC 23E
IEC 63478-2:2025 describes the requirements to measure users’ quality of experience (QoE) on multimedia conferencing services.
- Draft16 pagesEnglish languagesale 10% offe-Library read for×1 day
- 27-Nov-2025
- 33.160.60
- CLC/TC 100X








Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...