Lightning protection systems pure performance standard

Questionnaire CLC/TC 81X(Secretariat)0154/Q: decision to stop project

Betriebverhaltensnorm von Blitzschutzsystemen

Norme de performance pure des systèmes de protection contre la foudre

Standardne lastnosti sistemov zaščite pred delovanjem strele

General Information

Status
Not Published
Publication Date
05-Jul-2015
Withdrawal Date
05-Jan-2016
Current Stage
4098 - Decision to drop project - Standstill maintained / released - Enquiry
Start Date
26-May-2014
Completion Date
26-May-2014

Buy Standard

Draft
prEN 50622:2013
English language
9 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
oSIST prEN 50622:2013
01-januar-2014
6WDQGDUGQHODVWQRVWLVLVWHPRY]DãþLWHSUHGGHORYDQMHPVWUHOH
Lightning protection systems pure performance standard
Norme de performance pure des systèmes de protection contre la foudre
Ta slovenski standard je istoveten z: prEN 50622:2013
ICS:
91.120.40 =DãþLWDSUHGVWUHOR Lightning protection
oSIST prEN 50622:2013 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
oSIST prEN 50622:2013

---------------------- Page: 2 ----------------------
oSIST prEN 50622:2013
 DRAFT
EUROPEAN STANDARD
prEN 50622

NORME EUROPÉENNE
September 2013
EUROPÄISCHE NORM

ICS


English version


Lightning protection systems pure performance standard



Norme de performance pure des To be completed
systèmes de protection contre la foudre



This draft European Standard is submitted to CENELEC members for CENELEC enquiry.
Deadline for CENELEC: 2014-02-14.

It has been drawn up by CLC/TC 81X.

If this draft becomes a European Standard, CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national
standard without any alteration.

This draft European Standard was established by CENELEC in three official versions (English, French, German).
A version in any other language made by translation under the responsibility of a CENELEC member into its own
language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany,
Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland,
Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.

Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of
which they are aware and to provide supporting documentation.

Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to
change without notice and shall not be referred to as a European Standard.


CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

CEN-CENELEC Management Centre: Avenue Marnix 17, B - 1000 Brussels


© 2013 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Project: 23705 Ref. No. prEN 50622:2013 E

---------------------- Page: 3 ----------------------
oSIST prEN 50622:2013
prEN 50622:2013 - 2 -
1 Contents
2 Foreword . 3
3 Introduction . 4
4 1 General . 4
5 1.1 Object . 4
6 1.2 Scope . 4
7 2 Normative references . 4
8 3 Terms and definitions . 4
9 4 Installations under monitoring . 6
10 4.1 Lightning ground flash density N . 6
g
11 4.2 Collection area A . 6
d
12 4.3 Location factor C . 6
d
13 4.4 Number of dangerous events N for a structure . 6
D
14 4.5 Total number of expected dangerous events N . 7
DT
15 5 Monitoring Degrees . 7
16 6 Book of installation .
...

Questions, Comments and Discussion