Connectors for electrical and electronic equipment - Product requirements - Part 3-124: Rectangular connectors - Detail specification for 10-way, shielded, free and fixed connectors for I/O and data transmission with frequencies up to 500 MHz

This part of IEC 61076 covers 10-way, shielded, free and fixed rectangular connectors for data transmission with frequencies up to 500 MHz and specifies the common dimensions, mechanical, electrical and transmission characteristics and environmental requirements as well as test specifications respectively. Connectors covered in this document are provided in three codings that differ only for the position of the polarization key and keyway, in view of their differently intended use: - Connectors Type A and C are intended for 10/100 Mbit/s as well as for 1/ 2,5 / 5 /10 Gbit/s Ethernet communication. - Connectors Type B are intended for all other non-Ethernet applications such as signalling, serial or other industrial bus communication systems. A-coding: The 45° cut corner used as polarization key and keyway system is located on the lower left corner of the male fixed connector (viewed from mating face) (Figures 5a, 5b). B-coding: The 45° cut corner is located on the upper left corner of the male fixed connector (Figures 5c, 5d). C-coding: There are two 45° corners located at the upper left and lower left corner (Figures 5e, 5f). In this document, the three codings, A, B, and C are designated as "Type A", "Type B" and .Type C".

Steckverbinder für elektronische Einrichtungen - Produktanforderungen - Teil 3-124: Rechteckige Steckverbinder - Bauartspezifikation für 10-polige geschirmte freie und feste Steckverbinder für E/A und Datenübertragung mit Frequenzen bis zu 500 MHz

Connecteurs pour équipements électriques et électroniques - Exigences de produit - Partie 3-124: Connecteurs rectangulaires - Spécification particulière pour les fiches et les embases écrantées à 10 voies pour les entrées/sorties et la transmission de données à des fréquences jusqu'à 500 MHz

La présente partie de l'IEC 61076 couvre les fiches et les embases rectangulaires écrantées à 10 voies pour la transmission de données à des fréquences jusqu'à 500 MHz et elle spécifie les dimensions communes, les caractéristiques mécaniques, électriques et de transmission et les exigences environnementales ainsi que les spécifications d'essais. Les connecteurs couverts par le présent document sont codés de trois manières différentes pour indiquer la position de la clé de polarisation et du système de détrompage, en fonction de l'utilisation prévue: - Les connecteurs de Type A et C sont destinés à des applications de communication Ethernet jusqu'à 10/100 Mbit/s, mais aussi jusqu'à 1/2,5/5/10 Gbit/s. - Les connecteurs de Type B sont destinés à toutes les autres applications "non Ethernet" telles que les systèmes de signalisation, les systèmes de communication sur des bus séries ou industriels. Codage A: un bord coupé à 45°, servant de clé de polarisation et de système de détrompage, situé en bas à gauche de l'embase mâle (vue depuis la face d'accouplement), voir Figure 5a et Figure 5b. Codage B: un bord coupé à 45°, situé en haut à gauche de l'embase mâle, voir Figure 5c et Figure 5d. Codage C: deux bords coupés à 45°, situés en haut à gauche et en bas à gauche, voir Figure 5e et Figure 5f. Dans le présent document, les trois codages A, B et C sont appelés "Type A", "Type B" et "Type C".

Konektorji za električno in elektronsko opremo - Zahteve za izdelek - 3-124. del: Pravokotni konektorji - Podrobna specifikacija za 10-redne, oklepljene, proste ali pritrjene konektorje za izvajanje vhodno/izhodnih funkcij (I/O) in prenosa podatkov s frekvencami do 500 MHz (IEC 61076-3-124:2019)

Ta del standarda IEC 61076 zajema 10-redne, oklepljene, proste ali pritrjene pravokotne konektorje za prenos podatkov s frekvencami do 500 MHz ter določa običajne mere, mehanske, električne in prenosne lastnosti ter okoljske zahteve in specifikacije preskusov.
Konektorji, zajeti v tem dokumentu, so podani v treh označitvah, ki se razlikujejo le po položaju polarizacijske zagozde in utora z vidika drugačne predvidene uporabe:
• Konektorji tipa A in C so namenjeni za 10/100 Mbit/s in 1/2,5/5/10 Gbit/s ethernetno komunikacijo.
• Konektorji tipa B so namenjeni za vse druge neethernetne uporabe, kot so komunikacijski sistemi signalnih, serijskih in drugih industrijskih vodil.
Označitev A: Vogal, ki je odrezan pod kotom 45° in se uporablja kot sistem polarizacijske zagozde in utora, se nahaja v spodnjem levem vogalu moškega pritrjenega konektorja (pogled s prednje strani stikanja) (sliki 5a, 5b).
Označitev B: Vogal, ki je odrezan pod kotom 45°, se nahaja v zgornjem levem vogalu moškega pritrjenega konektorja (sliki 5c, 5d).
Označitev C: Dva vogala, ki sta odrezana pod kotom 45°, se nahajata v zgornjem levem in spodnjem levem vogalu (sliki 5e, 5f).
V tem dokumentu so tri označitve A, B in C označene kot »tip A«, »tip B« in »tip C«.

General Information

Status
Published
Publication Date
02-May-2019
Withdrawal Date
14-Apr-2022
Technical Committee
Drafting Committee
Current Stage
6060 - Document made available - Publishing
Start Date
03-May-2019
Completion Date
03-May-2019

Relations

Buy Standard

Standard
EN IEC 61076-3-124:2019
English language
48 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN IEC 61076-3-124:2019
01-julij-2019
Konektorji za električno in elektronsko opremo - Zahteve za izdelek - 3-124. del:
Pravokotni konektorji - Podrobna specifikacija za 10-redne, oklepljene, proste ali
pritrjene konektorje za izvajanje vhodno/izhodnih funkcij (I/O) in prenosa podatkov
s frekvencami do 500 MHz (IEC 61076-3-124:2019)
Connectors for electrical and electronic equipment - Product requirements - Part 3-124:
Rectangular connectors - Detail specification for 10-way, shielded, free and fixed
connectors for I/O and data transmission with frequencies up to 500 MHz (IEC 61076-3-
124:2019)
Steckverbinder für elektronische Einrichtungen - Produktanforderungen - Teil 3-124:
Rechteckige Steckverbinder - Bauartspezifikation für 10-polige geschirmte freie und
feste Steckverbinder für E/A und Datenübertragung mit Frequenzen bis zu 500 MHz
(IEC 61076-3-124:2019)
Connecteurs pour équipements électriques et électroniques - Exigences de produit -
Partie 3-124: Connecteurs rectangulaires - Spécification particulière pour les fiches et les
embases écrantées à 10 voies pour les entrées/sorties et la transmission de données à
des fréquences jusqu'à 500 MHz (IEC 61076-3-124:2019)
Ta slovenski standard je istoveten z: EN IEC 61076-3-124:2019
ICS:
31.220.10 Vtiči in vtičnice, konektorji Plug-and-socket devices.
Connectors
SIST EN IEC 61076-3-124:2019 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN IEC 61076-3-124:2019

---------------------- Page: 2 ----------------------

SIST EN IEC 61076-3-124:2019


EUROPEAN STANDARD EN IEC 61076-3-124

NORME EUROPÉENNE

EUROPÄISCHE NORM
May 2019
ICS 31.220.10

English Version
Connectors for electrical and electronic equipment - Product
requirements - Part 3-124: Rectangular connectors - Detail
specification for 10-way, shielded, free and fixed connectors for
I/O and data transmission with frequencies up to 500 MHz
(IEC 61076-3-124:2019)
Connecteurs pour équipements électriques et électroniques Steckverbinder für elektronische Einrichtungen -
- Exigences de produit - Partie 3-124: Connecteurs Produktanforderungen - Teil 3-124: Rechteckige
rectangulaires - Spécification particulière pour les fiches et Steckverbinder - Bauartspezifikation für 10-polige
les embases écrantées à 10 voies pour les entrées/sorties geschirmte freie und feste Steckverbinder für E/A und
et la transmission de données à des fréquences jusqu'à Datenübertragung mit Frequenzen bis zu 500 MHz
500 MHz (IEC 61076-3-124:2019)
(IEC 61076-3-124:2019)
This European Standard was approved by CENELEC on 2019-04-15. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden,
Switzerland, Turkey and the United Kingdom.


European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2019 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
 Ref. No. EN IEC 61076-3-124:2019 E

---------------------- Page: 3 ----------------------

SIST EN IEC 61076-3-124:2019
EN IEC 61076-3-124:2019 (E)
European foreword
The text of document 48B/2711/FDIS, future edition 1 of IEC 61076-3-124, prepared by SC 48B
"Electrical connectors" of IEC/TC 48 "Electrical connectors and mechanical structures for electrical
and electronic equipment" was submitted to the IEC-CENELEC parallel vote and approved by
CENELEC as EN IEC 61076-3-124:2019.
The following dates are fixed:
• latest date by which the document has to be implemented at national (dop) 2020-01-15
level by publication of an identical national standard or by endorsement
• latest date by which the national standards conflicting with the (dow) 2022-04-15
documen
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.