EN 50123-5:1997/A1:1999
(Amendment)Railway applications - Fixed installations - D.C. switchgear - Part 5: Surge arresters and low-voltage limiters for specific use in d.c. systems
Railway applications - Fixed installations - D.C. switchgear - Part 5: Surge arresters and low-voltage limiters for specific use in d.c. systems
prAA ratified as A1 * Superseded by EN 50123-5:2003
Bahnanwendungen - Ortsfeste Anlagen - Gleichstromschalteinrichtungen - Teil 5: Überspannungsableiter und Niederspannungsbegrenzer für spezielle Verwendung in Gleichstromsystemen
Applications ferroviaires - Installations fixes - Appareillage à courant continu - Partie 5: Parafoudres et limiteurs de tension pour usage spécifique dans les systèmes à courant continu
Railway applications - Fixed installation - D.C. switchgear - Part 5: Surge arrestűrs and low-voltage limiters for specific use in d.c. systems; Amendment A1
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
01-december-1999
5DLOZD\DSSOLFDWLRQV)L[HGLQVWDOODWLRQ'&VZLWFKJHDU3DUW6XUJHDUUHVWĦUV
DQGORZYROWDJHOLPLWHUVIRUVSHFLILFXVHLQGFV\VWHPV$PHQGPHQW$
Railway applications - Fixed installations - D.C. switchgear -- Part 5: Surge arresters and
low-voltage limiters for specific use in d.c. systems
Bahnanwendungen - Ortsfeste Anlagen - Gleichstromschalteinrichtungen -- Teil 5:
Überspannungsableiter und Niederspannungsbegrenzer für spezielle Verwendung in
Gleichstromsystemen
Applications ferroviaires - Installations fixes - Appareillage à courant continu -- Partie 5:
Parafoudres et limiteurs de tension pour usage spécifique dans les systèmes à courant
continu
Ta slovenski standard je istoveten z: EN 50123-5:1997/A1:1999
ICS:
29.130.99 Druge stikalne in krmilne Other switchgear and
naprave controlgear
29.280 (OHNWULþQDYOHþQDRSUHPD Electric
...
This May Also Interest You
This document provides railway operators, system integrators and product suppliers, with guidance and specifications on how cybersecurity will be managed in the context of EN 50126 1 RAMS lifecycle process. This document aims at the implementation of a consistent approach to the management of the security of the railway systems. This document can also be applied to the security assurance of systems and components/equipment developed independently of EN 50126 1:2017. This document applies to Communications, Signalling and Processing domain, to Rolling Stock and to Fixed Installations domains. It provides references to models and concepts from which requirements and recommendations can be derived and that are suitable to ensure that the residual risk from security threats is identified, supervised and managed to an acceptable level by the railway system duty holder. It presents the underlying security assumptions in a structured manner. This document does not address functional safety requirements for railway systems but rather additional requirements arising from threats and related security vulnerabilities and for which specific measures and activities need to be taken and managed throughout the lifecycle. The aim of this document is to ensure that the RAMS characteristics of railway systems / subsystems / equipment cannot be reduced, lost or compromised in the case of cyber attacks. The security models, the concepts and the risk assessment process described in this document are based on or derived from the IEC/EN IEC 62443 series. This document is consistent with the application of security management requirements contained within IEC 62443 2 1, which in turn are based on EN ISO/IEC 27001 and EN ISO 27002.
- Technical specification164 pagesEnglish languagesale 10% offe-Library read for×1 day
- 10-Aug-2023
- 35.030
- 45.020
- 2016/797/EU
- M/483
- CLC/TC 9X
This document provides requirements for electrical safety for: - dead working on an overhead contact line system; - working activities near an overhead contact line system when it is live. It applies to all work activities in relation to electrical hazards only. This document is applicable to overhead contact line systems with the following nominal voltages: - 1,5 kV and 3 kV dc; - 15 kV, 2x15 kV, 25 kV and 2x25 kV ac. It also provides requirements for work activities that can give rise to electrical hazards from the return circuit. This document does not cover electrical risk arising from: - live working on overhead contact line systems (live working can be carried out according to national requirements and practices); - working on or near other electrical sources. If there are no other rules or procedures, this document could be applied to overhead contact line systems with other nominal voltages.
- Standard39 pagesEnglish languagesale 10% offe-Library read for×1 day
- Standard39 pagesEnglish languagesale 10% offe-Library read for×1 day
Unchanged with respect to the current edition EN 50128:2011. Scope of the amendment: - Alignment with EN 50126-1:2017, EN 50126-2:2017 and EN 50129:2018 together with minor corrections
- Amendment14 pagesEnglish languagesale 10% offe-Library read for×1 day
2021: CLC legacy converted by DCLab NISOSTS
- Amendment4 pagesEnglish languagesale 10% offe-Library read for×1 day
- 06-Feb-2020
- 06-Aug-2020
- 35.240.60
- 45.020
- 2008/57/EC
- 2016/797/EU
- 96/48/EC
- M/483
- CLC/TC 9X
2021: CLC legacy converted by DCLab NISOSTS
- Amendment4 pagesEnglish languagesale 10% offe-Library read for×1 day
This European Standard applies to emission and immunity aspects of EMC for electrical and electronic apparatus and systems intended for use in railway fixed installations for power supply. This includes the power feed to the apparatus, the apparatus itself with its protective control circuits, trackside items such as switching stations, power autotransformers, booster transformers, substation power switchgear and power switchgear to other longitudinal and local supplies. Filters operating at railway system voltage (for example, for harmonic suppression or power factor correction) are not included in this standard since each site has special requirements. Filters would normally have separate enclosures with separate rules for access. If electromagnetic limits are required, these will appear in the specification for the equipment. If a port is intended to transmit or receive for the purpose of radio communication (intentional radiators, e.g. transponder systems), then the radiated emission requirement in this standard are not intended to be applicable to the intentional transmission from a radio-transmitter as defined by the ITU. The frequency range considered is from DC to 400 GHz. No measurements need to be performed at frequencies where no requirement is specified. Emission and immunity limits are given for items of apparatus which are situated: a) within the boundary of a substation which delivers electric power to a railway; b) beside the track for the purpose of controlling or regulating the railway power supply, including power factor correction; c) along the track for the purpose of supplying electrical power to the railway other than by means of the conductors used for contact current collection, and associated return conductors. Included are high voltage feeder systems within the boundary of the railway which supply substations at which the voltage is reduced to the railway system voltage; d) beside the track for controlling or regulating electric power supplies to ancillary railway uses. This category includes power supplies to marshalling yards, maintenance depots and stations; e) various other non-traction power supplies from railway sources which are shared with railway traction. The immunity levels given in this standard apply for: - vital equipment such as protection devices; - equipment having connections to the traction power conductors; - apparatus inside the 3 m zone; - ports of apparatus inside the 10 m zone with connection inside the 3 m zone; - ports of apparatus inside the 10 m zone with cable length > 30 m. Apparatus and systems which are in an environment which can be described as residential, commercial or light industry, even when placed within the physical boundary of the railway substation, shall comply with EN 61000-6-1:2007 for immunity and EN 61000-6-3:2007 for emission requirements. Excluded from the immunity requirements of this standard is power supply apparatus which is intrinsically immune to the tests defined in Tables 1 to 6. NOTE An example is an 18 MVA 230 kV to 25 kV power supply transformer. These specific provisions are to be used in conjunction with the general provisions in EN 50121-1. This part of the standard covers requirements for both apparatus and fixed installations. The sections for fixed installations are not relevant for CE marking.
- Amendment3 pagesEnglish languagesale 10% offe-Library read for×1 day
This European Standard applies to signalling and telecommunication apparatus that is installed inside the railway environment. Signalling and telecommunication apparatus mounted in vehicles is covered by EN 50121-3-2:2016, signalling and telecommunication apparatus installed inside the substation and connected to substation equipment is covered by EN 50121-5:2016. This European Standard specifies limits for emission and immunity and provides performance criteria for signalling and telecommunications (S&T) apparatus (including power supply systems belonging to S&T) which may interfere with other apparatus inside the railway environment, or increase the total emissions for the railway environment and so risk causing Electro-Magnetic Interference (EMI) to apparatus outside the railway system. The requirements specified in this standard apply for: — vital equipment such as interlocking or command and control; — apparatus inside the 3 m zone; — ports of apparatus inside the 10 m zone with connection inside the 3 m zone; — ports of apparatus inside the 10 m zone with cable length > 30 m. Other apparatus not covered by at least one of these given cases should be in compliance with EN 61000-6-2. If a port is intended to transmit or receive for the purpose of radio communication (intentional radiators, e.g. transponder systems), then the radiated emission requirement in this standard are not intended to be applicable to the intentional transmission from a radio-transmitter as defined by the ITU. Immunity limits do not apply in the exclusion bands as defined in the corresponding EMC related standard for radio equipment. The standard does not specify basic personal safety requirements for apparatus such as protection against electric shock, unsafe operation, insulation co-ordination and related dielectric tests. The requirements were developed for and are applicable to this set of apparatus when operating under normal conditions. Fault conditions of the apparatus have not been taken into account. The frequency range considered is from DC to 400 GHz. No measurements need to be performed at frequencies where no requirement is specified. For products in the scope of EN 61000-3-2, EN 61000-3-3, EN 61000-3-11 or EN 61000-3-12 the requirements of those standards also apply. These specific provisions are to be used in conjunction with the general provisions in EN 50121-1:2016. The immunity and emission levels do not of themselves guarantee that the integration of apparatus will necessarily be satisfactory. The standard cannot cover all the possible configurations of the apparatus, but the test levels are sufficient to achieve satisfactory EMC in the majority of cases.
- Amendment3 pagesEnglish languagesale 10% offe-Library read for×1 day
In accordance with the ERTMS/ETCS specifications, Subset 121, UIC 612 leaflet, ERA_ERTMS_015560 document, EN 50126 and EN 61375 series requirements, this Technical Report describes the Train Display System (TDS) in the driver’s cab, and the link between the TDS/TDC and some of its interfaces (Blue box and blue links only): [figure] Figure 1 - Functional architecture The scope of this document is to define the functional architecture around the TDC. This Technical Report excludes the following items: - Communication protocols (e.g. EN 61375 series); - Ergonomic aspects; - Interface with ETCS (Subset 121); - Train functions; - GSM-R EIRENE functions; - Use of the displays as terminals for maintenance purpose.
- Technical report20 pagesEnglish languagesale 10% offe-Library read for×1 day
- 10-May-2018
- 35.240.60
- 45.020
- 2008/57/EC
- M/483
- CLC/TC 9X
This part 1 of EN 50126 - considers RAMS, understood as reliability, availability, maintainability and safety and their interaction; - considers the generic aspects of the RAMS life cycle. The guidance in this part can still be used in the application of specific standards; - defines: - a process, based on the system life cycle and tasks within it, for managing RAMS; - a systematic process, tailorable to the type and size of the system under consideration, for specifying requirements for RAMS and demonstrating that these requirements are achieved; - addresses railway specifics; - enables conflicts between RAMS elements to be controlled and managed effectively; - does not define: - RAMS targets, quantities, requirements or solutions for specific railway applications; - rules or processes pertaining to the certification of railway products against the requirements of this standard; - an approval process for the railway stakeholders. This part 1 of EN 50126 is applicable to railway application fields, namely Command, Control and Signalling, Rolling Stock and Fixed Installations, and specifically: - to the specification and demonstration of RAMS for all railway applications and at all levels of such an application, as appropriate, from complete railway systems to major systems and to individual and combined subsystems and components within these major systems, including those containing software; in particular: - to new systems; - to new systems integrated into existing systems already accepted, but only to the extent and insofar as the new system with the new functionality is being integrated. It is otherwise not applicable to any unmodified aspects of the existing system; - as far as reasonably practicable, to modifications and extensions of existing systems already accepted, but only to the extent and insofar as existing systems are being modified. It is otherwise not applicable to any unmodified aspect of the existing system; - at all relevant phases of the life cycle of an application; - for use by railway duty holders and the railway suppliers. It is not required to apply this standard to existing systems which remain unmodified, including those systems already compliant with any former version of EN 50126. The process defined by this European Standard assumes that railway duty holders and railway suppliers have business-level policies addressing Quality, Performance and Safety. The approach defined in this standard is consistent with the application of quality management requirements contained within EN ISO 9001.
- Standard103 pagesEnglish languagesale 10% offe-Library read for×1 day
- Standard114 pagesFrench languagesale 10% offe-Library read for×1 day
This part 2 of EN 50126 - considers the safety-related generic aspects of the RAMS life-cycle; - defines methods and tools which are independent of the actual technology of the systems and subsystems; - provides: - the user of the standard with the understanding of the system approach to safety which is a key concept of EN 50126; - methods to derive the safety requirements and their safety integrity requirements for the system and to apportion them to the subsystems; - methods to derive the safety integrity levels (SIL) for the safety-related electronic functions. NOTE This standard does not allow the allocation of safety integrity levels to non-electronic functions. - provides guidance and methods for the following areas: - safety process; - safety demonstration and acceptance; - organisation and independence of roles; - risk assessment; - specification of safety requirements; - apportionment of functional safety requirements; - design and implementation. - provides the user of this standard with the methods to assure safety with respect to the system under consideration and its interactions; - provides guidance about the definition of the system under consideration, including identification of the interfaces and the interactions of this system with its subsystems or other systems, in order to conduct the risk analysis; - does not define: - RAMS targets, quantities, requirements or solutions for specific railway applications; - rules or processes pertaining to the certification of railway products against the requirements of this standard; - an approval process by the safety authority. This part 2 of EN 50126 is applicable to railway applications fields, namely Command, Control and Signalling, Rolling Stock and Fixed Installations, and specifically: - to the specification and demonstration of safety for all railway applications and at all levels of such an application, as appropriate, from complete railway systems to major systems and to individual and combined sub-systems and components within these major systems, including those containing software, in particular: - to new systems; - to new systems integrated into existing systems already accepted, but only to the extent and insofar as the new system with the new functionality is being integrated. It is otherwise not applicable to any unmodified aspects of the existing system; - as far as reasonably practicable, to modifications and extensions of existing systems accepted prior to the creation of this standard, but only to the extent and insofar as existing systems are being modified. It is otherwise not applicable to any unmodified aspect of the existing system; - at all relevant phases of the life-cycle of an application; - for use by railway duty holders and the railway suppliers. It is not required to apply this standard to existing systems which remain unmodified, including those systems already compliant with any former version of EN 50126. The process defined by this European Standard assumes that railway duty holders and railway suppliers have business-level policies addressing Quality, Performance and Safety. The approach defined in this standard is consistent with the application of quality management requirements contained within EN ISO 9001.
- Standard77 pagesEnglish languagesale 10% offe-Library read for×1 day
- Standard87 pagesFrench languagesale 10% offe-Library read for×1 day
- 12-Oct-2017
- 45.020
- 2008/57/EC
- M/483
- CLC/TC 9X
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.