EN IEC 61851-23-3:2026
(Main)Electric vehicle conductive charging system - Part 23-3: DC electric vehicle supply equipment - Megawatt charging systems
- Abstract
This part of IEC 61851 applies to the EV supply equipment to provide energy transfer between the supply network and electric vehicles (EVs), with a rated maximum voltage at side A (supply network side) up to 1 000 V AC or up to 1 500 V DC and a rated maximum voltage at side B (EV side) up to 1 250 V DC.
NOTE A rated maximum voltage of the EV supply equipment at side B of up to 1 500 V DC is under consideration.
This document specifies the EV supply equipment of megawatt charging system (MCS) equipped with a coupler according to IEC TS 63379. Systems different to MCS using a coupler specified in IEC TS 63379 are under consideration.
The requirements for bidirectional power flow systems are under consideration.
This document does not cover all safety aspects related to maintenance.
This document specifies systems with protective separation between side A and side B.
The requirements for digital communication between the EV supply equipment and the EV for control of energy transfer are defined in ISO 15118-10 and ISO 15118-20.
EV supply equipment in compliance with this document is not intended to provide energy transfer to a single EV using
– multiple vehicle connectors of the same EV supply equipment, or
– multiple EV supply equipment.
The requirements for such use cases are not specified in this document but are under consideration.
The requirements for EVs mated to EV supply equipment according to this document are specified in ISO 5474-3:2024, Annex B.
- Status
- Published
- Publication Date
- 08-Oct-2026
- Technical Committee
- CLC/TC 69X - Electrical systems for electric road vehicles
- Current Stage
- 6060 - Document made available - Publishing
- Start Date
- 09-Oct-2026
- Due Date
- 31-Dec-2024
- Completion Date
- 31-Dec-2024
EN IEC 61851-23-3:2026 is the CLC standard for DC electric vehicle supply equipment used in Megawatt Charging Systems (MCS). It specifies how the equipment connects to the supply network and the EV, and it covers electrical ratings, communication, protection, construction, and test methods for manufacturers, system designers, test laboratories, and buyers specifying MCS charging equipment.
What does EN IEC 61851-23-3:2026 specify?
EN IEC 61851-23-3:2026 applies to EV supply equipment for energy transfer between the supply network and EVs, with side A up to 1 000 V AC or 1 500 V DC and side B up to 1 250 V DC. The document focuses on MCS equipment with a coupler according to IEC TS 63379, and it uses ISO 15118-10 and ISO 15118-20 for digital communication between the EV supply equipment and the EV.
The standard is read together with IEC 61851-1:2017 and IEC 61851-23:2023. Its particular requirements supplement or modify Part 23, and Annex CC contains the system MCS-specific requirements.
The standard does not cover all safety aspects related to maintenance. Requirements for bidirectional power flow systems, systems without protective separation between side A and side B, and automatic connection of system MCS are identified as under consideration. It also states that a compliant EV supply equipment is not intended to charge one EV through multiple vehicle connectors of the same EV supply equipment or through multiple EV supply equipments.
| Annex | What it covers |
|---|---|
| Annex AA | System A, not applicable in this part |
| Annex BB | System B, not applicable in this part |
| Annex CC | System MCS requirements, including circuit diagrams, communication, energy transfer, safety, tests, and state logic |
| Annex DD | Bidirectional power transfer control, informative |
| Annex EE | Test load impedance verification, informative |
| Annex FF | Multi-side B separated EV supply equipment |
| Annex GG | Communication and energy transfer process between the EV supply equipment and EV, informative |
| Annex HH | Touch current and touch impulse current, informative |
What are the key requirements of EN IEC 61851-23-3:2026?
Electrical ratings and system classification
EN IEC 61851-23-3:2026 classifies the equipment as System MCS. Clause 4 ties the system to a rated maximum voltage at side B of up to 1 250 V DC, and Clause 5 uses System MCS as the only system classification in this part.
The current capability is also defined in practical terms. For equipment with rated continuous current at side B of 500 A or more, the equipment shall provide its rated continuous current or rated continuous power from 500 V to 1 250 V DC, and it shall still be able to deliver at least 500 A continuously from 400 V to below 500 V. For equipment below 500 A, the rated continuous current or power applies from 400 V to 1 250 V. This matters because the charger must match the EV battery voltage window without losing its usable current capability.
Basic charging functions and communication
Clause 6 makes DC supply according to an EVCC request a mandatory Mode 4 function. The equipment has to perform continuous protective conductor continuity checking, detect correct connection, energize and de-energize the power supply, limit current, measure current and voltage, support compatibility checks, check insulation resistance before energy transfer, protect against overvoltage, handle short-circuit checks before energy transfer, and support user-initiated shutdown.
Annex CC defines the system MCS signaling and communication model. It uses Charge Enable (CE) and Insertion Detection (ID) as the basic signaling functions, and it specifies digital communication over 10BASE-T1S with ISO 15118-20. In practice, that means the EV supply equipment and the EV must agree on states, readiness, charging parameters, and session control before energy transfer begins.
Protection against electric shock and overvoltage
Clause 8 and Annex HH are central to safety. The equipment shall limit the voltage between side B live parts (DC+/DC-) and the protective conductor under normal operation using a formula that caps the limit and ties it to the present side B voltage. The document also allows brief disturbances, and it notes that balancing the voltage to PE helps reduce touch impulse current.
The standard also tightens overvoltage response at side B. If the present voltage between DC+ and DC- stays above the threshold from Table 202 for more than 9 ms during energy transfer, the EV supply equipment shall trigger an emergency shutdown in 1 ms or less. For insulation faults to PE, the Annex CC test sequences show how the equipment is expected to detect the fault, shut down, and bring voltages down to safe levels within the required time.
Clause 8 also changes the Y-capacitance approach for side B by referring to Table 203, and it defines the minimum protective measures in Figure 205 and Table 204. For designers, this means the insulation structure, capacitance to PE, and protective separation have to be planned together, not treated as separate details.
Thermal management and temperature control
Clause 101.2 covers energy transfer with a thermal management system or thermal sensing only. The EV supply equipment shall continuously monitor the temperature data of the DC contacts of the side B cable assembly during the communication session, and it shall react to the thermal sensing device in the cable assembly.
The temperature limits are practical and specific. The DC contact temperature shall not exceed 100 °C, and if the contact temperature stays above 100 °C for 8 s or reaches 105 °C for 1 s, the EV supply equipment shall trigger an error shutdown in 1 s or less. The related tests use a system-specific EV simulator, a modified reference device, and a 40 °C ambient test condition, so suppliers need to design both the hardware and the validation setup around sustained high-current operation.
Construction, interface, and multi-side B use
Clause 9 and Clause 11 link the system to the conductive interface and cable assembly requirements, while Clause 103 and Annex CC require the vehicle connector and vehicle inlet to comply with IEC TS 63379. Annex CC also assigns the CE and ID contacts and requires the digital communication channel to use PHY1 and PHY2 as the 10BASE-T1S lines.
Annex FF adds requirements for multi-side B separated EV supply equipment. If the same power electronic converters are used for System MCS and another system, the equipment shall limit short-circuit current and Y-capacitance to the needs of each system. If two or more side B systems can operate simultaneously, they shall not interfere with one another. This matters for modular charging stations and shared power stages.
What terms does EN IEC 61851-23-3:2026 define?
- Charge enable conductor (CE) - A conductor in the cable assembly that, together with the protective conductor, forms part of the charge enable circuit.
- Insertion detection function (ID) - The electrical or mechanical means used to indicate whether the vehicle connector or EV plug is inserted.
- System MCS - The MCS charging system covered by this part, used for megawatt DC charging equipment.
- Side A - The supply network side of the EV supply equipment.
- Side B - The EV side of the EV supply equipment.
- Protective conductor - The conductor used for protective earthing and safety-related continuity checking.
- EV supply equipment - The charging equipment that transfers energy between the supply network and the EV.
Who uses EN IEC 61851-23-3:2026?
EN IEC 61851-23-3:2026 is used by EVSE manufacturers, charger designers, cable assembly and vehicle connector suppliers, and test laboratories that validate MCS hardware and communication behavior. It is also used by certification bodies, quality managers, and buyers who need to specify DC charging equipment for heavy-duty EV applications.
In practice, it helps teams design the power stage, select the coupler interface, implement CE and ID signaling, set up ISO 15118-based communication, and verify shutdown and thermal behavior. It is most relevant where charging power is high enough that voltage, current, capacitance, and heat management become system-level design issues.
What changed in EN IEC 61851-23-3:2026 from the previous edition?
EN IEC 61851-23-3:2026 supplements and modifies IEC 61851-23:2023 for Megawatt Charging Systems. The comparison given in the document highlights these changes:
- side B rated maximum voltage is extended to 1 250 V
- the rated continuous current at side B follows IEC TS 63379:202X
- basic signaling uses CE and ID instead of CP and PP
- digital communication uses Ethernet 10BASE-T1S with ISO 15118-20 as the application layer, instead of HomePlug GreenPHY with ISO 15118-2, ISO 15118-20, or DIN 70121
Which standards are used with EN IEC 61851-23-3:2026?
- IEC 61851-1:2017 - the general charging system requirements that this part is read with
- IEC 61851-23:2023 - the base Part 23 clauses that this part supplements and modifies
- IEC TS 63379:202X - defines the vehicle connector, vehicle inlet, and cable assembly for megawatt DC charging
- ISO 15118-10:202X - defines the physical layer and data link layer requirements for wired Ethernet communication
- ISO 15118-20:2022 and ISO 15118-20:2022/AMD1:202X - define the communication layer used for energy transfer control
- IEEE 802.3-2022 - provides the Ethernet reference for 10BASE-T1S requirements
- Open Alliance Inc. Channel and components - Requirements for 10BASE-T1S link segments - provides the compliance check method for the communication channel
- ISO 5474-3:2023 - gives the EV-side requirements referenced for mating and charging behavior
What does the EN IEC 61851-23-3:2026 document contain?
EN IEC 61851-23-3:2026 contains the system MCS-specific requirements, sequence diagrams, test setups, and annexed operating logic needed to design and validate megawatt DC charging equipment. Annex CC includes the circuit diagrams for configuration HH, the CE and ID state tables, the normal start-up and shutdown sequences, pause and renegotiation behavior, emergency shutdown behavior, compatibility checks, and detailed test cases.
The document also includes formulas and tables that define voltage limits, Y-capacitance limits, current ripple limits, temperature limits, and shutdown thresholds. Annex EE provides the test load impedance verification curve for System MCS, and Annex HH provides the touch current and touch impulse current considerations used to judge safety around side B live parts and the protective conductor.
Relations
- Effective Date
- 29-Sep-2026
- Effective Date
- 29-Sep-2026
- Effective Date
- 29-Sep-2026
- Effective Date
- 29-Sep-2026
- Effective Date
- 29-Sep-2026
- Effective Date
- 23-Sep-2026
Get Certified
Connect with accredited certification bodies for this standard

TÜV Rheinland
TÜV Rheinland is a leading international provider of technical services.

TÜV SÜD
TÜV SÜD is a trusted partner of choice for safety, security and sustainability solutions.

DEKRA Certification Inc.
DEKRA US certification services.
Sponsored listings
Frequently Asked Questions
EN IEC 61851-23-3:2026 is a standard published by CLC. Its full title is "Electric vehicle conductive charging system - Part 23-3: DC electric vehicle supply equipment - Megawatt charging systems". This standard covers: This part of IEC 61851 applies to the EV supply equipment to provide energy transfer between the supply network and electric vehicles (EVs), with a rated maximum voltage at side A (supply network side) up to 1 000 V AC or up to 1 500 V DC and a rated maximum voltage at side B (EV side) up to 1 250 V DC. NOTE A rated maximum voltage of the EV supply equipment at side B of up to 1 500 V DC is under consideration. This document specifies the EV supply equipment of megawatt charging system (MCS) equipped with a coupler according to IEC TS 63379. Systems different to MCS using a coupler specified in IEC TS 63379 are under consideration. The requirements for bidirectional power flow systems are under consideration. This document does not cover all safety aspects related to maintenance. This document specifies systems with protective separation between side A and side B. The requirements for digital communication between the EV supply equipment and the EV for control of energy transfer are defined in ISO 15118-10 and ISO 15118-20. EV supply equipment in compliance with this document is not intended to provide energy transfer to a single EV using – multiple vehicle connectors of the same EV supply equipment, or – multiple EV supply equipment. The requirements for such use cases are not specified in this document but are under consideration. The requirements for EVs mated to EV supply equipment according to this document are specified in ISO 5474-3:2024, Annex B.
This part of IEC 61851 applies to the EV supply equipment to provide energy transfer between the supply network and electric vehicles (EVs), with a rated maximum voltage at side A (supply network side) up to 1 000 V AC or up to 1 500 V DC and a rated maximum voltage at side B (EV side) up to 1 250 V DC. NOTE A rated maximum voltage of the EV supply equipment at side B of up to 1 500 V DC is under consideration. This document specifies the EV supply equipment of megawatt charging system (MCS) equipped with a coupler according to IEC TS 63379. Systems different to MCS using a coupler specified in IEC TS 63379 are under consideration. The requirements for bidirectional power flow systems are under consideration. This document does not cover all safety aspects related to maintenance. This document specifies systems with protective separation between side A and side B. The requirements for digital communication between the EV supply equipment and the EV for control of energy transfer are defined in ISO 15118-10 and ISO 15118-20. EV supply equipment in compliance with this document is not intended to provide energy transfer to a single EV using – multiple vehicle connectors of the same EV supply equipment, or – multiple EV supply equipment. The requirements for such use cases are not specified in this document but are under consideration. The requirements for EVs mated to EV supply equipment according to this document are specified in ISO 5474-3:2024, Annex B.
EN IEC 61851-23-3:2026 is classified under the following ICS (International Classification for Standards) categories: 43.120 - Electric road vehicles. The ICS classification helps identify the subject area and facilitates finding related standards.
EN IEC 61851-23-3:2026 has the following relationships with other standards: It is inter standard links to EN ISO 15118-20:2022, HD 60364-5-54:2011, EN IEC 61851-23:2026, EN ISO 15118-10:2025, HD 60364-4-43:2023, EN ISO 15118-20:2022/A1:2026. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN IEC 61851-23-3:2026 is associated with the following European legislation: EU Directives/Regulations: 2014/94/EU, 2023/1804, 2023/1804-1, 2023/1804-2; Standardization Mandates: M/581. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
EN IEC 61851-23-3:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 3.2 Insulation
- 3.3 Functions
- 3.3.1 control pilot conductor
- 3.3.5 proximity function
- 4 General requirements
- 5 Classification
- 6 Charging modes and functions
- 7 Communications
- 7.1 Digital communication between the EV supply equipment and the EV
- 8 Protection against electric shock
- 9 Conductive electrical interface requirements
- 9.1 General
- 9.3 Functional description of the basic interface
- 9.5 Functional description of the DC interface
- 9.6 Functional description of the combined interface
- 10 Requirements for adaptors
- 11 Cable assembly requirements
- 11.7 Cable management and storage means for cables assemblies
- 12 EV supply equipment constructional requirements and tests
- 12.7 Dielectric withstand voltage
- 13 Overload and short-circuit protection
- 14 Automatic reclosing of protective devices
- 15 Emergency switching or disconnect (optional)
- 16 Marking and instructions
- 10 Hz 1,5 I × 0,75 %
- 4 DC-pins
- 6 EV simulator with test load
- 0 V to 1 250 V
- Annex AA
- Annex BB
- Annex CC
- 3 EVCC charge enable measurement point
- 1 SECC insertion detection measurement point
- 2 EVCC insertion detection measurement point
- 11 T T
- 5 EVSE_max
- 14 EVSE_SideB_DC+
- 14 EVSE_SideB_DC−
- Annex EE
- Annex FF
- Annex GG
- Annex HH
- Bibliography
INTRODUCTION Responding to the global challenges of CO reduction and energy security, the automobile
industry has started the development and commercialization of heavy-duty electric vehicles (EV). These heavy duty EVs are equipped with significantly larger batteries than passenger cars or light commercial vehicles. The charging power provided by standards published before the publication of this document does not allow recharging of these batteries within the time needed for a commercial application of heavy duty EVs – especially considering long routes with limited time for intermediate charging. Consequently, this document allows for superior charging power up to several megawatts and describes the related safety and interoperability requirements. Table 201 shows the comparison between IEC 61851-23 and this document. Table 201 – Comparison between IEC 61851-23 and IEC 61851-23-3 Topic IEC 61851-23:2023 IEC 61851-23-3 Rated maximum voltage of the EV 1 000 V 1 250 V supply equipment at side B (EV side) Rated continuous current of the EV Maximum as defined in As defined in IEC TS 63379 supply equipment at side B (EV IEC 62196-3 side) Basic signalling CP and PP (Annex CC) CE and ID Digital communication HomePlug GreenPHY Ethernet 10BASE-T1S (IEC 61851-24) with ISO 15118-2, (ISO 15118-10) with ISO 15118-20 ISO 15118-20 or DIN SPEC 70121 as application layer as application layer
Although the system described in this document has been developed for heavy duty EVs, its application is not limited practically to these.
SIST EN IEC 61851-23-3:2026
1 Scope
This part of IEC 61851 applies to the EV supply equipment to provide energy transfer between the supply network and electric vehicles (EVs), with a rated maximum voltage at side A (supply network side) up to 1 000 V AC or up to 1 500 V DC and a rated maximum voltage at side B (EV side) up to 1 250 V DC.
NOTE A rated maximum voltage of the EV supply equipment at side B of up to 1 500 V DC is under consideration. This document specifies the EV supply equipment of megawatt charging system (MCS) equipped with a coupler according to IEC TS 63379. Systems different to MCS using a coupler specified in IEC TS 63379 are under consideration.
The requirements for bidirectional power flow systems are under consideration. This document does not cover all safety aspects related to maintenance. This document specifies systems with protective separation between side A and side B. The requirements for digital communication between the EV supply equipment and the EV for control of energy transfer are defined in ISO 15118-10 and ISO 15118-20. EV supply equipment in compliance with this document is not intended to provide energy transfer to a single EV using - multiple vehicle connectors of the same EV supply equipment, or - multiple EV supply equipment.
The requirements for such use cases are not specified in this document but are under consideration.
The requirements for EVs mated to EV supply equipment according to this document are specified in ISO 5474-3:2024, Annex B.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
IEC 60364-4-43:2023, Low-voltage electrical installations - Part 4-43: Protection for safety - Protection against overcurrent IEC 60364-5-54:2011, Low-voltage electrical installations - Part 5-54: Selection and erection of electrical equipment - Earthing arrangements and protective conductors IEC 61851-23:2023, Electric vehicle conductive charging system - Part 23: DC electric vehicle supply equipment IEC TS 63379:2026, Vehicle connector, vehicle inlet and cable assembly for megawatt DC charging ISO 5474-3:2024, Electrically propelled road vehicles - Functional and safety requirements for power transfer between vehicle and external electric circuit - Part 3: DC power transfer
SIST EN IEC 61851-23-3:2026
ISO 15118-10:2025, Road vehicles - Vehicle-to-grid communication interface - Part 10:
Physical layer and data link layer requirements for single-pair Ethernet nd ISO 15118-20:2022, Road vehicles - Vehicle-to-grid communication interface - Part 2: 2 generation network layer and application layer requirements ISO 15118-20:2022/AMD1:2026 IEEE 802.3-2022, IEEE Standard for Ethernet 10BASE-T1S channel and components requirements for link segments - Electrical requirements and measurements specification for 10BASE-T1S channels and components [online], Open Alliance Inc. Version 1.1, 2025, [viewed 2026-02-05]. Available at: https://opensig.org/wpcontent/uploads/2025/06/10BASE-T1S-Channel-and-Component-Requirements-for-Link- Segments.pdf
3 Terms and definitions
For the purposes of this document, the terms and definitions given in IEC 61851-23:2023 apply, except as follows.
ISO and IEC maintain terminology databases for use in standardization at the following addresses:
- IEC Electropedia: available at https://www.electropedia.org/
- ISO Online browsing platform: available at https://www.iso.org/obp
3.2 Insulation
Addition:
3.2.201 simple separation separation between electric circuits or between an electric circuit and local earth by means of basic insulation [SOURCE: IEC 60050-826:2021, 195-06-30]
3.3 Functions
3.3.1 control pilot conductor
Replacement:
charge enable conductor CE conductor incorporated in a cable assembly, which, together with the protective conductor, is part of the charge enable circuit
3.3.5 proximity function
Replacement:
insertion detection function ID electrical means to indicate the insertion state of the vehicle connector in the vehicle inlet of the EV
SIST EN IEC 61851-23-3:2026
4 General requirements
IEC 61851-23:2023, Clause 4, is applicable, except as follows. Addition:
System MCS shall have protective separation between side A and side B. See 8.105.1. The specific requirements for EV supply equipment with multiple side Bs (EV sides) are provided in Annex FF.
General information on the touch current and touch impulse current is provided in Annex HH, unless otherwise specified in this document.
The following applies in addition:
- the requirements and tests for system C in IEC 61851-23:2023 apply for system MCS;
- all references in IEC 61851-23:2023 to "Annex CC" are replaced with "Annex CC of this document".
EV supply equipment with a rated continuous current at side B ≥ 500 A:
- in the voltage range: 500 V DC ≤ voltage at side B ≤ 1 250 V, the EV supply equipment shall provide the rated continuous current at side B or rated continuous power at side B;
- in the voltage range: 400 V DC ≤ voltage at side B < 500 V DC, the EV supply equipment shall be capable of continuously providing a current at side B ≥ 500 A. EV supply equipment with a rated continuous current at side B < 500 A shall provide the rated continuous current at side B or rated continuous power at side B in the voltage range: 400 V DC ≤ voltage at side B ≤ 1 250 V.
5 Classification
IEC 61851-23:2023, Clause 5, is applicable, except as follows. 5.101 Characteristics of EV supply equipment 5.101.3 System Replacement:
The EV supply equipment shall be classified according to the system:
- system MCS (see Annex CC).
6 Charging modes and functions
IEC 61851-23:2023, Clause 6, is applicable, except as follows. 6.3 Functions provided in Mode 4 6.3.1 Mandatory functions in Mode 4
6.3.1.1 General
Replacement, in the penultimate paragraph, of "ISO 17409" with "ISO 5474-3".
SIST EN IEC 61851-23-3:2026
6.3.1.2 Continuous continuity checking of the protective conductor
Replacement, in the second paragraph, of "Compliance for system C is checked by CC.7.5.5":
Compliance for system MCS is checked by CC.7.5.5 of this document.
6.3.1.3 Verification that the EV is properly connected to the EV supply equipment
Replacement of the second paragraph:
Proper connection is assumed when the continuity of the charge enable circuit is detected.
6.3.1.4 Energization of the power supply to the EV
IEC 61851-1:2017, 6.3.1.4, is applicable, except as follows.
Replacement of the first paragraph:
The vehicle connector shall not be energized unless the charge enable function between EV supply equipment and EV has been established correctly with signal states allowing energization.
Amendment:
The third paragraph is not applicable.
IEC 61851-23:2023, 6.3.1.4, is applicable, except as follows.
Replacement of "The test setup for system C is shown in Figure 131" with "The test setup for system MCS is shown in Figure 207".
6.3.1.5 De-energization of the power supply to the EV
Replacement of the first paragraph:
If the insertion detection signal is interrupted, the EV supply equipment shall perform an emergency shutdown as indicated by system MCS.
6.3.1.101 DC supply for the EV Replacement, in the first paragraph, of the first sentence:
The EV supply equipment shall provide a DC current and voltage to side B according to an EVCC request.
Replacement, in the first paragraph, of "101.1.1, 101.1.2, 101.1.3, 101.1.4, 101.1.5, and 101.1.6." with "101.1.1, 101.1.2, 101.1.3, 101.1.4 and 101.1.5 of this document, and 101.1.6 of IEC 61851-23:2023".
Replacement of the third paragraph:
Compliance is checked by the applicable tests in 101.1.1 through 101.1.5 of this document, and 101.1.6 of IEC 61851-23:2023.
SIST EN IEC 61851-23-3:2026
6.3.1.103 Latching of the vehicle connector Replacement of the last paragraph:
Vehicle connectors and vehicle inlets shall comply with the requirements of IEC TS 63379. See also 9.101 of this document.
6.3.1.106 Protection against overvoltage at side B between DC+ and DC– 6.3.1.106.1 General Replacement of the third paragraph:
According to ISO 5474-1:2024, 6.2.8, when unmated, the EV can have a voltage > 60 V DC and > 30 V AC between DC+ and PE, and between DC− and PE. It is recommended that the EV does not have a common mode voltage > 60 V, as unbalanced insulation faults can generate differential voltages at side B > 60 V. For system MCS, the EV may try to use R 6 and R 7 in S S Figure CC.204 of the disabled side B circuit to limit this common mode voltage. 6.3.1.106.2 Protection against overvoltage at side B between DC+ and DC− by emergency shutdown Replacement:
The EV supply equipment shall trigger an emergency shutdown in 1 ms or less if, during the energy transfer stage, the present voltage at side B between DC+ and DC− is more than the voltage thresholds specified in Table 202 for more than 9 consecutive ms. Table 202 – Voltage threshold for emergency shutdown reaction Negotiated maximum voltage at Voltage threshold side B (U) V V U ≤ 500 550 500 < U ≤ 750 825 750 < U ≤ 850 935 850 < U ≤ 1 000 1 100 1 000 < U ≤ 1250 1 375
Compliance is checked by CC.7.5.7.1.
6.3.1.107 Verification of vehicle connector latching IEC 61851-23:2023, 6.3.1.107, is not applicable.
6.3.1.112 Voltage limitation between side B live parts (DC+ and DC−) and protective conductor 6.3.1.112.1 Maximum voltage between side B live parts (DC+ and DC−) and protective conductor under normal operation Replacement:
Under normal operation, the EV supply equipment shall limit the present voltage between side B live parts (DC+/DC−) and the protective conductor to U (see Formula (201)). The voltage
limit U includes the additional voltage from an IMD (see Figure 201).
SIST EN IEC 61851-23-3:2026
U ≤ min(U ;max (614;0,5 × U + 75)) (201) 2 1 1
where U is the present voltage at side B between DC+ and DC−, expressed in volts;
U is the present voltage between side B live parts (DC+/DC−) and the protective conductor,
expressed in volts.
NOTE 1 Transient overvoltages are not limited by voltage balancing. NOTE 2 According to ISO 5474-3:2024, Annex B, the vehicle deactivates any means that actively impact the balance between DC+ and the protective conductor and between DC− and the protective conductor before closing its disconnection device.
NOTE 3 A balanced voltage between side B live parts (DC+/DC−) and the protective conductor minimizes the touch impulse current.
Infrequent short-term (< 10 s) voltages above the limit U due to disturbances are permitted,
for example at startup or due to load/source switching.
When the absolute value of the present voltage between side B live parts (DC+/DC–) and the protective conductor exceeds the limit U Formula (201), the EV supply equipment shall reduce
within 10 s, and energy transfer the absolute value of the present voltage below the limit U
shall not stop.
The EV supply equipment may employ passive or active techniques to minimize the touch impulse current, possibly in coordination with the IMD or earth fault monitor of the EV supply equipment.
The steady-state touch current limits of 8.101.4 apply also under single fault conditions in the circuit that facilitates the voltage balancing.
Compliance is checked with design review.
Figure 201 a) and b) show an example of a correct implementation.
SIST EN IEC 61851-23-3:2026
a) Typical IMD implementation
b) Waveform of an IMD implementation with a pulsed signal Key V V voltage at side B between DC+ and DC− upper voltage limit for DC+ and DC− 1 max maximum common mode voltage including V V lower voltage limit for DC+ and DC− 2 min IMD , the touch current limitation to the c1 NOTE If the voltage between DC+/DC− and protective conductor exceeds U
curve specified as special protection in 8.105.1 cannot be met. Figure 201 – Typical voltages between side B live parts (DC+/DC−) and protective conductor under normal operation
SIST EN IEC 61851-23-3:2026
Compliance is checked by the following tests.
Test 1:
The test setup for system MCS is shown in Figure 207.
1) Preconditions for the test i) The EV simulator shall use the following limits: V = V EV_rated_max EVSE_rated_max_sideB and I = I during the compatibility check (see EV_rated_max EVSE_rated_boost_sideB 6.3.1.104) in order to not limit the operating range.
ii) The EV simulator shall draw current during this test, in order to reach and maintain power transfer.
2) The following voltage and current values shall be applied:
i) V = 0,8 × V ; EV_simulator EVSE_rated_max_sideB ii) I = I = I / 2.
EVSE_intended EV_trg EVSE_rated_boost_sideB 3) Perform the following actions.
i) The FPT sequence is to be successfully done until t = t according to Figure CC.205,
including the message "PowerDeliveryReq".
ii) Wait until A 1 ≥ 80 % of I for 5 s.
T EV_trg iii) Measure V 3, V 4 and V 5 continuously for 100 s.
T T T Low pass filter should be applied, in order to filter out transients. Recommended cut-off frequency: 10 Hz to 200 Hz.
4) Check the expected results.
V 3 and V 4 shall be less than or equal to the following limit: |V 3| ≤ V 5 + 50 V DC and T T T T |V 4| ≤ V 5 + 50 V DC.
T T Test 2:
The test setup for system MCS is shown in Figure 207.
Pre-conditions for the test:
a) The EV supply equipment manufacturer shall specify the operating point at which the EV supply equipment has the maximum energy stored in the Y-capacitance between DC+/DC– and the protective conductor.
b) The test setup shall have the maximum EV Y-capacitance (C 7/ C 8) for the operating point T T specified in step a), as specified in ISO 5474-3:2023, Annex B. NOTE 4 The EV supply equipment can switch in more PECs depending on the current demand, as well as put modules in series or parallel due to the voltage demand. This can influence the total Y-capacitance and leakage current.
c) Approach the test point as specified in step a) according to CC.7.4. d) Adjust the measurement equipment to measure the touch leakage current. See the example in Figure 202.
SIST EN IEC 61851-23-3:2026
Figure 202 – Measurement of the touch leakage current The test shall be executed as follows.
1) Close S 9.
T 2) Determine the threshold of R 4 where the IMD trips.
T 3) Add ≤ 10 % to the trip value for R 4 in order to continuously transfer energy with the T maximum allowed asymmetric leakage resistance.
4) Restart the communication session until the operating point defined in step a) is reached. 5) Set R 4 = 100 Ω.
T 6) Close S 9.
T 7) Wait for 0,2 s.
8) Change R 4 to the value defined in step 3).
T 9) Measure the present voltage from DC+ to the protective conductor and from DC– to the protective conductor for 60 s.
10) Check the expected results:
i) Verify that, 10 s after step 7), the present voltage from DC+ to the protective conductor and from DC– to the protective conductor is below the limit defined by Formula (201) 11) Repeat the test by:
i) closing S 11 in step 1), T ii) determining the threshold with R 5 in step 2), T iii) setting R 5 = 100 Ω in step 5), T iv) closing S 11 in step 6), T 5 in step 8).
v) changing R T 6.3.1.112.2 Maximum voltage between side B live parts (DC+/DC−) and the protective conductor in case of an insulation fault at side B to the protective conductor Replacement:
The insulation requirements between side B of the EV supply equipment and the protective conductor, excluding the side B cable assembly, are specified in 8.105.5. See Figure 203 a) for the fault locations and Figure 203 b) and c) for the example waveforms of fault A and B.
SIST EN IEC 61851-23-3:2026
a) Fault locations
b) Waveform of fault A c) Waveform of fault B Key PE protective conductor T detection time of the IMD/earth leakage current monitoring device plus the error shutdown time D+S (single line) basic insulation (see fault A) (double lines) double insulation or basic insulation and electrically protective screening (shielding) or reinforced insulation (see fault B)
Figure 203 – Examples of a fault between the secondary circuit and the protective conductor If, in a single fault condition, a voltage more than 110 % of the present voltage at side B between DC+ and DC− is present for more than 1 s between side B live parts (DC+/DC−) and the protective conductor, the EV supply equipment shall trigger and complete an error shutdown in 4 s or less.
SIST EN IEC 61851-23-3:2026
In case of an insulation fault between side B live parts (DC+/DC−) and the protective conductor, the EV supply equipment shall limit the temporary overvoltage between side B live parts (DC+/DC–) and the protective conductor to 1 800 V DC.
Compliance to the 1 800 V temporary overvoltage limit shall be done by design review. NOTE 1 According to ISO 5474-3:2024, 6.2.5, the EV can withstand short-term temporary overvoltage of 1 980 V DC with durations up to 5 s.
NOTE 2 In IEC 61851-23:2014 , 6.4.3.113, assuming U equal to 150 V DC, formula (2 × U + 1 000) × 1,41 V n n results in 1 833 V DC. This value was rounded down to 1 800 V DC. The formula is based on the dielectric strength
requirements from ISO 6469-3:2011 , 8.3.3.3.2.
The EV supply equipment shall withstand a temporary overvoltage condition caused by the EV with a voltage equal to 1 250 V DC between side B live parts (DC+/DC−) and the protective conductor for 5 s.
NOTE 3 In case of fault A, the IMD requirements cover error shutdown conditions. Compliance to the error shutdown condition is checked by the following tests. The test setup for system MCS is shown in Figure 207.
Test between DC− and the protective conductor.
1) Connect the EV supply equipment to a test load with a dedicated EV simulator. 2) Measure voltages V 3, V 4, V 5 and current A 1.
T T T T 3) Start energy transfer with the procedure specified by the EV supply equipment manufacturer.
4) Confirm that the operating point is at OP2 as specified in IEC 61851-23:2023, Figure 133.
5) Preconditions for the fault condition:
i) R 3 shall be 175 kΩ; T ii) U 2 shall be set in order that, when S 8 is closed, V 4 is 0,11 × T T T V .
EVSE_rated_max_sideB 6) Close S 8.
...