Glow-starters for fluorescent lamps

EN following parallel vote

Glimmstarter für Leuchtstofflampen

Interrupteurs d'amorçage à lueur pour lampes à fluorescence (starters)

Tlivni starterji za fluorescenčne sijalke - Dopolnilo A1 (IEC 60155:1993/A1:1995)

General Information

Status
Published
Publication Date
10-Dec-1995
Withdrawal Date
31-Aug-1996
Drafting Committee
Parallel Committee
Current Stage
6060 - Document made available - Publishing
Start Date
11-Dec-1995
Completion Date
11-Dec-1995

Relations

Buy Standard

Amendment
EN 60155:1999/A1:1999
English language
8 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 60155:1999/A1:1999
01-julij-1999
7OLYQLVWDUWHUML]DIOXRUHVFHQþQHVLMDONH'RSROQLOR$ ,(&$
Glow-starters for fluorescent lamps (IEC 60155:1993/A1:1995)
Glimmstarter für Leuchtstofflampen (IEC 60155:1993/A1:1995)
Interrupteurs d'amorçage à lueur pour lampes à fluorescence (starters) (CEI
60155:1993/A1:1995)
Ta slovenski standard je istoveten z: EN 60155:1995/A1:1995
ICS:
29.140.30 )OXRUHVFHQþQHVLMDONH6LMDONH Fluorescent lamps.
Discharge lamps
SIST EN 60155:1999/A1:1999 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

INTERNATIONAL IEC


STANDARD 60155



1993



AMENDMENT 1
1995-10

Amendment 1
Glow-starters for fluorescent lamps


This English-language version is derived from the original
bilingual publication by leaving out all French-language
pages. Missing page numbers correspond to the French-
language pages.
 IEC 1995 Copyright - all rights reserved
No part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical,
including photocopying and microfilm, without permission in writing from the publisher.
International Electrotechnical Commission, 3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, Switzerland
Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmail@iec.ch Web: www.iec.ch
PRICE CODE
D
Commission Electrotechnique Internationale
International Electrotechnical Commission
МеждународнаяЭлектротехническаяКомиссия
For price, see current catalogue

---------------------- Page: 2 ----------------------

Oo
IEC:1 995 155 Amend. 1 - 3 -
FOREWORD
This amendment has been prepared by sub-committee 34A: Lamps, of IEC technical com-
mittee 34: Lamps and related equipment.
The text of this amendment is based on the following documents:
DIS
Report on voting
34A/623/RVD
34A/586/DIS
Full information on the voting for the approval of this amendment can be found in the
report on voting indicated in the above table.
Page 3
Contents
Add the title of the new clause 11 and the new annex C as follows:
11 Information for luminaire design
Annex C - Information for luminaire design
Page 9
2 Normative references
Add the following normative reference:
ISO 4046: 1978, Paper, board, pulp and related items - Vocabulary
Page 19
Subclause 7.12.3
Delete the text of this subclause and replace it by the following:
7.12.3 The capacitor shall be resistant to flame and ignition.
Compliance shall be checked by the following test. The capacitors are each subjected to a
gradually increasing a.c. voltage until breakdown occurs. The voltage source used to this
effect should have a short-circuit power of approximately 1 kVA.
Thereafter, each capacitor shall be completely wrapped with tissue paper as specified in 6.86
of ISO 4046 and shall be connected in series with a 40 W inductive ballast complying with
the requirements of annex A and operated for 5 min at the rated voltage of the ballast.
During this test, the capacitor shall not inflame the tissue paper.

---------------------- Page: 3 ----------------------

155 Amend. 1 ©IEC:1 995 - 5 -
Page 23
8.4 Speed of operation
Delete the existing text and replace it by the following new text:
With the exception of 20 W lamps as specified in IEC 81 for which the voltage shall be
103,5 V, a voltage equal to the test voltage of the lamp starting test for the relevant lamp
specified in IEC 81 or in IEC 901 shall be app
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.