Dependability management - Part 3-10: Application guide - Maintainability and maintenance

Zuverlässigkeitsmanagement - Teil 3-10: Anwendungsleitfaden – Instandhaltbarkeit und Unterstützbarkeit

Gestion de la sûreté de fonctionnement - Partie 3-10: Guide d’application - Maintenabilité et maintenance

Vodenje zanesljivosti - 3-10. del: Navodilo za uporabo - Vzdrževalnost in vzdrževanje

General Information

Status
Not Published
Publication Date
05-Jan-2025
Technical Committee
Drafting Committee
Current Stage
5020 - Vote circulated - Formal Approval
Start Date
23-Aug-2024
Completion Date
23-Aug-2024

Buy Standard

Draft
prEN IEC 60300-3-10:2024
English language
68 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
oSIST prEN IEC 60300-3-10:2024
01-januar-2024
Vodenje zanesljivosti - 3-10. del: Navodilo za uporabo - Vzdrževalnost in
vzdrževanje
Dependability management - Part 3-10: Application guide - Maintainability and
maintenance
Gestion de la sûreté de fonctionnement - Partie 3-10: Guide d’application - Maintenabilité
et maintenance
Ta slovenski standard je istoveten z: prEN IEC 60300-3-10:2023
ICS:
03.120.01 Kakovost na splošno Quality in general
21.020 Značilnosti in načrtovanje Characteristics and design of
strojev, aparatov, opreme machines, apparatus,
equipment
oSIST prEN IEC 60300-3-10:2024 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

oSIST prEN IEC 60300-3-10:2024

oSIST prEN IEC 60300-3-10:2024
56/2007/CDV
COMMITTEE DRAFT FOR VOTE (CDV)
PROJECT NUMBER:
IEC 60300-3-10 ED2
DATE OF CIRCULATION: CLOSING DATE FOR VOTING:
2023-11-03 2024-01-26
SUPERSEDES DOCUMENTS:
56/1962/CD, 56/1971B/CC
IEC TC 56 : DEPENDABILITY
SECRETARIAT: SECRETARY:
United Kingdom Ms Stephanie Lavy
OF INTEREST TO THE FOLLOWING COMMITTEES: PROPOSED HORIZONTAL STANDARD:

Other TC/SCs are requested to indicate their interest, if any, in
this CDV to the secretary.
FUNCTIONS CONCERNED:
EMC ENVIRONMENT QUALITY ASSURANCE SAFETY
SUBMITTED FOR CENELEC PARALLEL VOTING NOT SUBMITTED FOR CENELEC PARALLEL VOTING
Attention IEC-CENELEC parallel voting
The attention of IEC National Committees, members of
CENELEC, is drawn to the fact that this Committee Draft for Vote
(CDV) is submitted for parallel voting.
The CENELEC members are invited to vote through the
CENELEC online voting system.
This document is still under study and subject to change. It should not be used for reference purposes.
Recipients of this document are invited to submit, with their comments, notification of any relevant patent rights of which they are
aware and to provide supporting documentation.
Recipients of this document are invited to submit, with their comments, notification of any relevant “In Some Countries” clauses to
be included should this proposal proceed. Recipients are reminded that the CDV stage is the final stage for submitting ISC clauses.
(See AC/22/2007 or NEW GUIDANCE DOC).

TITLE:
Dependability management – Part 3-10: Application guide – Maintainability and maintenance

PROPOSED STABILITY DATE: 2024
NOTE FROM TC/SC OFFICERS:
electronic file, to make a copy and to print out the content for the sole purpose of preparing National Committee positions.
You may not copy or "mirror" the file or printed version of the document, or any part of it, for any other purpose without
permission in writing from IEC.

oSIST prEN IEC 60300-3-10:2024
56/2007/CDV – 2 – IEC CDV 60300-3-10  IEC 2023
CONTENTS
FOREWORD . 5
INTRODUCTION . 7
1 Scope . 8
2 Normative references . 8
3 Terms, definitions and abbreviations . 8
3.1 Terms and definitions. 8
3.2 Abbreviations . 10
4 Maintainability and maintenance overview . 10
4.1 Description of maintainability . 10
4.2 Description of maintenance . 11
4.3 Principles . 11
4.4 Benefits . 12
4.5 Interfaces. 12
4.5.1 General . 12
4.5.2 Effect of maintainability on reliability . 12
4.5.3 Effect of maintainability on supportability and support . 13
5 Manager responsibility . 13
5.1 Overview . 13
5.2 Maintenance policy . 14
6 Specifying for maintainability and maintenance. 15
6.1 Defining requirements . 15
6.2 Characteristics of maintainable items . 15
6.3 Measures of maintainability . 17
6.3.1 Overview . 17
6.3.2 Quantitative measures of maintainability . 17
6.3.3 Qualitative measures of maintainability . 19
6.3.4 Measures of testability . 21
6.4 Measures of maintenance effectiveness . 21
7 Maintainability programme . 22
7.1 Overview . 22
7.2 Plan the maintainability programme . 23
7.2.1 Establishing the context . 23
7.2.2 Define the objectives and scope . 23
7.2.3 Plan maintainability activities and associated resources . 24
7.3 Maintainability activities . 25
7.3.1 Modelling . 25
7.3.2 Allocation . 25
7.3.3 Analysis . 26
7.3.4 Prediction . 26
7.3.5 Trade-off studies . 28
7.3.6 Measurement . 29
7.4 Perform maintainability activities . 29
7.5 Review of maintainability activities . 30
8 Maintenance programme . 30
8.1 Overview . 30

oSIST prEN IEC 60300-3-10:2024
IEC CDV 60300-3-10  IEC 2023 – 3 – 56/2007/CDV
8.2 Planning the maintenance programme . 32
8.2.1 Establish the context . 32
8.2.2 Maintenance concept . 32
8.2.3 Establish management arrangements and resources . 33
8.3 Establishing the maintenance tasks . 34
8.3.1 Maintenance analysis . 34
8.3.2 Task Packaging . 36
8.3.3 Scheduling . 36
8.4 Performing maintenance . 37
8.5 Data collection and maintenance improvement . 40
9 Managing maintainability and maintenance over the life cycle . 41
9.1 General . 41
9.2 Concept stage. 41
9.2.1 Overview . 41
9.3 Development stage . 41
9.3.1 Maintainability design . 41
9.3.2 Maintenance and support design . 43
9.3.3 Design reviews . 44
9.4 Realization stage . 44
9.4.1 Manufacturing . 44
9.4.2 Installation . 44
9.5 Utilization Stage. 45
9.5.1 Operations and maintenance . 45
9.5.2 Software maintenance help desk . 45
9.6 Enhancement Stage . 46
9.7 Retirement Stage . 46
10 Assurance . 47
10.1 Assurance objectives . 47
10.2 Methods of assurance . 47
10.2.1 Overview . 47
10.2.2 Methods of verification . 47
10.2.3 Verification process . 48
10.2.4 Conditions and constraints. 49
10.2.5 Dependability case . 49
11 Contractor management . 49
12 Maintainability and maintenance information . 50
12.1 General . 50
12.2 Information types . 51
12.3 Data and information control . 52
12.3.1 General . 52
12.3.2 Configuration management . 52
Annex A (informative) Maintainability Analysis . 54
A.1 General . 54
A.2 Design support. 58
A.2.1 Design criteria and check-lists . 58
A.2.2 Design reviews . 58
A.3 Maintainability and maintenance activities, tools and procedures . 59

oSIST prEN IEC 60300-3-10:2024
56/2007/CDV – 4 – IEC CDV 60300-3-10  IEC 2023
A.3.1 Block diagrams . 59
A.3.2 Failure Mode and Effects Analysis (FMEA) . 60
A.3.3 Fault Tree Analysis (FTA) . 61
A.3.4 Reliability Centred Maintenance (RCM) . 61
A.3.5 Task Analysis .
...

Questions, Comments and Discussion