Abstract

IEC 63402-2-2:2026 specifies the fundamental aspects of semantic interoperability for the S2 interface and the related data exchange between a CEM and the resource managers within the premises. It provides a technology independent set of data models and interaction patterns in order to enable applications for energy management within the premises. This document does not include:
– mappings to concrete data representations (XML, JSON and similar);
– mappings to application protocols for the message passing;
– security related aspects.
This group EE publication is primarily intended to be used as an EE standard for the products mentioned in the scope, but is also intended to be used by TCs in the preparation of publications for products which are included in the boundary mentioned in the scope of this document

Status
Published
Publication Date
24-Aug-2026
Current Stage
PPUB - Publication issued - 60 Publication
Start Date
25-Aug-2026
Due Date
31-Jul-2026
Completion Date
31-Jul-2026

Buy Documents

Standard

iec63402-2-2{ed1.0}en - Energy efficiency - Customer energy management system - Part 2-2: Data model and messaging - Interface between the customer energy manager and resource managers

ISBN:978-2-8327-1442-3
Release Date:25-Aug-2026
English and French language (218 pages)
sale 15% off
Preview
sale 15% off
Preview
Standard

iec63402-2-2{ed1.0}fr - Systemes pour l'efficacité énergétique - Systemes de gestion d'énergie client - Part 2-2: Modele de données et messagerie - Interface entre le gestionnaire d'énergie client et les gestionnaires de ressources pour foyers domestiques/bâtiments

ISBN:978-2-8327-1442-3
Release Date:25-Aug-2026
English and French language (218 pages)
sale 15% off
Preview
sale 15% off
Preview

IEC 63402-2-2 is an IEC International Standard on energy efficiency for customer energy management systems. It specifies the semantic interoperability of the S2 interface and the related data exchange between a Customer Energy Manager (CEM) and resource managers inside the premises, using technology-independent data models and interaction patterns. It is intended for premises-level energy management implementations and for technical committees preparing related product standards.

What does IEC 63402-2-2 specify?

IEC 63402-2-2 specifies the S2 interface between a CEM and resource managers within premises. The document focuses on semantic interoperability, data models, and interaction patterns so that different implementations can exchange energy-management information in a consistent way.

The standard is organized into clauses 1 to 9 and Annex A. Clause 4 explains energy-management roles and architecture, Clause 5 describes the Resource Manager, Clause 6 describes the CEM, Clause 7 explains the key concepts used by S2, Clause 8 defines the data models, and Clause 9 defines the communication tasks and interaction models.

AnnexWhat it covers
Annex AInformative use cases, including organization, planning, management, and case studies such as electric vehicle charging

IEC 63402-2-2 does not specify mappings to concrete data formats such as XML or JSON, mappings to application protocols, or security aspects. In practice, that means the standard defines what the information means and how it is logically exchanged, while the communication technology is left to implementations.

What are the key requirements of IEC 63402-2-2?

IEC 63402-2-2 separates the meaning of the information from the way it is serialized or transported. That separation matters because the same S2 concepts can be implemented on different communication stacks without changing the underlying energy-management semantics.

The interface is defined around premises-level energy management

Clause 4 and Clause 6 place the CEM at the center of premises energy management. The CEM coordinates production, consumption, and storage, while the resource manager presents the capabilities and constraints of the connected device or device group.

In practice, this means the CEM does not need device-specific internal detail to act on flexibility. It works with a common description of what the resource can do, not with the native protocol of each device.

The Resource Manager is a software boundary between domains

Clause 5 describes the Resource Manager (RM) as a software function that represents a flexible energy resource. The RM can run on the device itself, on a separate device, or in a cloud environment.

This matters because the RM is the place where device-specific information is enriched into S2-level energy information. For example, a device that only knows on/off states can be represented to the CEM in terms of energy behavior, constraints, and flexibility.

The CEM supports three optimization styles

Clause 6 identifies three CEM optimization categories: local optimization, implicit control, and explicit control. Local optimization uses information from within the premises, implicit control adds incentive signals from outside, and explicit control adds direct instructions.

In practice, this helps buyers and integrators decide how much external coordination is expected. A system focused on local savings needs different signaling than one that follows tariffs or direct grid instructions.

Clause 7 defines the energy-management concepts used in S2

Clause 7 explains the main concepts behind S2, including abnormal condition, power measurements, power forecasts, and the different control types. An abnormal condition is the case where the CEM may sacrifice user comfort to avoid a worse outcome such as a full interruption.

This is important because it defines when the system may go beyond normal comfort-oriented operation. Clause 7 also limits power measurements to supported commodities and to the power exchanged between the device and the local grid, and it describes forecasts as ordered elements with duration, forecast value, and optional statistical certainty.

S2 supports five control families

Clause 7 and Clause 8 structure control around five families: power envelope based control (PEBC), power profile based control (PPBC), operation mode based control (OMBC), fill rate based control (FRBC), and demand driven based control (DDBC).

Each family matches a different kind of device flexibility. PEBC uses power limits and energy constraints, PPBC uses planned or shifted power sequences, OMBC offers selectable operating modes, FRBC applies to systems described by fill level and usage behavior, and DDBC supports response to a demand signal with selectable operating behavior.

Clause 8 defines the data models and enumerations

Clause 8 defines the data models for generic data, resource-manager data, power forecasts, and each of the control families. It also defines the enumerations used by the model, including RoleType, Commodity, Currency, InstructionStatus, ControlType, PowerForecastType, and the control-family status types.

This matters in implementation because the data exchanged on S2 can be mapped to named structures instead of ad hoc messages. The document therefore gives a common vocabulary for software design, conformance testing, and integration.

Clause 9 defines the interaction tasks

Clause 9 describes how the data models are exchanged between the CEM and the Resource Manager. It organizes the exchange into generic tasks, such as updating resource-manager details, activating a control type, sending power measurements, and updating or revoking power forecasts, then adds task sets for each control family.

In practice, this gives implementers a task-based message flow rather than a single fixed protocol. It also allows different tasks to run when their prerequisites are met, which is useful for systems that update measurements, forecasts, and instructions independently.

Annex A shows how the concepts are used

Annex A gives use cases for organization, planning, and management. It includes examples such as CEM configuration, collecting energy and tariff profiles, selecting energy sequences based on cost, handling grid limits, and electric-vehicle charging with photovoltaic power limitation.

That helps readers connect the abstract data models to real installations. It is especially useful when designing systems that combine storage, generation, and flexible loads.

What terms does IEC 63402-2-2 define?

IEC 63402-2-2 defines the core vocabulary used by the S2 interface.

  • Customer Energy Manager (CEM) - an internal automation function that optimizes energy consumption, production, and storage in premises according to the customer’s preferences.
  • Resource Manager (RM) - a function that represents a logical group of devices or a single smart device and sends unambiguous instructions to it.
  • communication S1 - the interface between the CEM and the Energy Management Gateway (EMG).
  • communication S2 - the interface between the CEM and the Resource Manager.
  • abnormal condition - a situation in which a Resource Manager must sacrifice user comfort when the CEM requests it.
  • prosumer - a household or device that both produces and consumes the same commodity.
  • Home and Building Electronic System / Système de gestion technique du bâtiment (HBES/SGTB) - a logical group of devices using multi-application communication for functions such as lighting, heating, energy, water, alarms, and security.
  • Single Application Smart System (SASS) - a group of devices for one application, such as heating or lighting, that can consume, produce, or store energy and be controlled by a Resource Manager.

Who uses IEC 63402-2-2?

IEC 63402-2-2 is used by engineers and software architects who implement CEMs, Resource Managers, and premises energy-management platforms. It is also relevant to product designers working on smart appliances, heating systems, batteries, photovoltaic systems, electric vehicle charging, and HBES/SGTB equipment.

Quality managers and buyers use it when they need a common S2 data model for interoperability across devices and suppliers. Technical committees also use it when preparing product publications for devices that fall within the standard’s scope.

Which standards are used with IEC 63402-2-2?

IEC 63402-2-2 relies on a small set of named references that supply shared architecture, use cases, and external code systems.

  • IEC TR 62746-2:2015 - provides the use cases and requirements background for the interface between the CEM and a power management system; Annex A builds on this use-case family.
  • IEC 63402-1 - provides the general requirements and architecture for customer energy management systems, as well as shared terms and definitions.
  • ISO 4217 - provides currency codes used by the model where tariff or price information is expressed.
  • ISO 15118-20 - provides the electric-vehicle communication context referenced in the EV charging case studies.

What does the IEC 63402-2-2 document contain?

IEC 63402-2-2 contains architectural figures, concept diagrams, data-model tables, interaction models, and informative use cases. Clause 8 is especially table-heavy: it defines the structures for resource-manager details, power values, forecasts, control-specific objects, and enumerations. Clause 9 contains interaction figures for each task family, showing how updates, revocations, measurements, forecasts, and instructions flow between the CEM and the Resource Manager.

The document also includes figures that illustrate power envelopes, power profiles, operation modes, fill-rate control, and demand-driven control. Annex A adds real-use examples, including configuration, planning, management, and electric-vehicle charging scenarios, which are useful for design reviews, testing, and system integration.

Buy Documents

Standard

iec63402-2-2{ed1.0}en - Energy efficiency - Customer energy management system - Part 2-2: Data model and messaging - Interface between the customer energy manager and resource managers

ISBN:978-2-8327-1442-3
Release Date:25-Aug-2026
English and French language (218 pages)
sale 15% off
Preview
sale 15% off
Preview
Standard

iec63402-2-2{ed1.0}fr - Systemes pour l'efficacité énergétique - Systemes de gestion d'énergie client - Part 2-2: Modele de données et messagerie - Interface entre le gestionnaire d'énergie client et les gestionnaires de ressources pour foyers domestiques/bâtiments

ISBN:978-2-8327-1442-3
Release Date:25-Aug-2026
English and French language (218 pages)
sale 15% off
Preview
sale 15% off
Preview

Get Certified

Connect with accredited certification bodies for this standard

DNV

DNV is an independent assurance and risk management provider.

NA Norway Verified

BSI Group

BSI (British Standards Institution) is the business standards company that helps organizations make excellence a habit.

UKAS United Kingdom Verified

Bureau Veritas

Bureau Veritas is a world leader in laboratory testing, inspection and certification services.

COFRAC France Verified

Sponsored listings

Frequently Asked Questions

IEC 63402-2-2:2026 is a standard published by the International Electrotechnical Commission (IEC). Its full title is "Energy efficiency - Customer energy management system - Part 2-2: Data model and messaging - Interface between the customer energy manager and resource managers". This standard covers: IEC 63402-2-2:2026 specifies the fundamental aspects of semantic interoperability for the S2 interface and the related data exchange between a CEM and the resource managers within the premises. It provides a technology independent set of data models and interaction patterns in order to enable applications for energy management within the premises. This document does not include: – mappings to concrete data representations (XML, JSON and similar); – mappings to application protocols for the message passing; – security related aspects. This group EE publication is primarily intended to be used as an EE standard for the products mentioned in the scope, but is also intended to be used by TCs in the preparation of publications for products which are included in the boundary mentioned in the scope of this document

IEC 63402-2-2:2026 specifies the fundamental aspects of semantic interoperability for the S2 interface and the related data exchange between a CEM and the resource managers within the premises. It provides a technology independent set of data models and interaction patterns in order to enable applications for energy management within the premises. This document does not include: – mappings to concrete data representations (XML, JSON and similar); – mappings to application protocols for the message passing; – security related aspects. This group EE publication is primarily intended to be used as an EE standard for the products mentioned in the scope, but is also intended to be used by TCs in the preparation of publications for products which are included in the boundary mentioned in the scope of this document

IEC 63402-2-2:2026 is classified under the following ICS (International Classification for Standards) categories: 03.100.70 - Management systems; 27.015 - Energy efficiency. Energy conservation in general; 29.020 - Electrical engineering in general. The ICS classification helps identify the subject area and facilitates finding related standards.

IEC 63402-2-2:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms, definitions and abbreviated terms
  • 3.1 Terms and definitions
  • 3.1.1 customer energy manager
  • 3.1.2 power envelope based control
  • 3.1.3 power profile based control
  • 3.1.4 operation mode based control
  • 3.1.5 fill rate based control
  • 3.1.6 demand driven based control
  • 3.1.7 resource manager
  • 3.1.8 role
  • 3.1.9 S1 communication
  • 3.1.10 S2 communication
  • 3.1.11 smart grid
  • 3.1.12 smart grid operator
  • 3.1.13 time slot
  • 3.1.14 use case
  • 3.1.15 user
  • 3.1.16 prosumer
  • 3.1.17 single application smart system
  • 3.1.18 home and building electronic system
  • 3.1.19 abnormal condition
  • 3.2 Abbreviated terms
  • 4 Energy management
  • 4.1 Architectural overview
  • 4.2 Description
  • 4.3 Energy management roles
  • 5 Resource manager
  • 10 W. This means that the resource manager shall enrich the information it receives from the
  • 6 Customer energy manager (CEM)
  • 6.1 General
  • 6.2 Local optimization
  • 6.3 Implicit control
  • 6.4 Explicit control
  • 6.5 Summary
  • 7 Energy management concepts
  • 7.1 General
  • 7.2 Design philosophy
  • 7.3 Abnormal condition
  • 7.4 Power measurements
  • 7.5 Power forecasts
  • 7.6 Control types
  • 8 Energy management data models
  • 8.1 Basic data types
  • 8.2 Resource manager
  • 8.3 Power forecast
  • 8.4 Control types
  • 8.5 Enumerations
  • 9 Communication
  • 9.1 General
  • 9.2 Generic tasks
  • 9.3 Power envelope based control tasks
  • 9.4 Power profile based control tasks
  • 9.5 Operation mode based control tasks
  • 9.6 Fill rate based control tasks
  • 9.7 Demand driven based control tasks
  • Annex A
  • Bibliography

Introduction

Over recent decades, energy production and its consumption patterns have changed dramatically. Although central energy production is still dominant, the trend for distributed production is distinctive following an increasing number of renewables. Alternative energy sources are highly fluctuating in their production capabilities, which can result in the grid operators having difficulty to keep a balance between energy production and consumption. The complexity of keeping the grid reliable is further increased by the change in the electric energy consumption and production of the customer itself, e.g., the use of electric vehicles and personal generation facilities.

A Smart Grid allows the grid operator to be flexible and reactive. Such reactivity uses communication between energy consuming and producing entities, from single family houses to large factories.

This document describes aspects of the smart grid that relate specifically to the premises (home or building) part of the smart grid and describes the common interface between equipment in the premises and the smart grid. This document defines the fundamental aspects of semantic interoperability for the S2 interface and the related data exchange between a CEM and the Resource Managers within the premises.

Different use cases are explained in Annex A, which help to understand the philosophy of this document.

This document is based on EN 50491-12-2 [1] which also served as a basis for ETSI TS 103 410-1 SAREF4ENER [2].

1 Scope

This document specifies the fundamental aspects of semantic interoperability for the S2 interface and the related data exchange between a CEM and the resource managers within the premises. It provides a technology independent set of data models and interaction patterns in order to enable applications for energy management within the premises. This document does not include:

  • mappings to concrete data representations (XML, JSON and similar);
  • mappings to application protocols for the message passing;
  • security related aspects.

This group EE publication is primarily intended to be used as an EE standard for the products mentioned in the scope, but is also intended to be used by TCs in the preparation of publications for products which are included in the boundary mentioned in the scope of this document.

2 Normative references

The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.

IEC TR 62746-2:2015, Systems interface between customer energy management system and the power management system - Part 2: Use cases and requirements IEC 63402-1, Energy Efficiency - Customer Energy Management Systems -- Part 1: General Requirements and Architecture ISO 4217, Codes for the representation of currencies ISO 15118-20, Road vehicles - Vehicle to grid communication interface - Part 20: Network and application protocol requirements

3 Terms, definitions and abbreviated terms

3.1 Terms and definitions

For the purposes of this document, the terms and definitions given in IEC 63402-1, and the following apply.

ISO and IEC maintain terminology databases for use in standardization at the following addresses:

  • IEC Electropedia: available at https://www.electropedia.org/
  • ISO Online browsing platform: available at https://www.iso.org/obp

3.1.1 customer energy manager

CEM internal automation function for optimizing the energy consumption, production and storage within the premises according to the preferences of the customer using internal flexibilities and typically based on external information received through the energy management gateway and possibly other data sources [SOURCE: IEC 63402-1:2025 [3], 3.1.1]

3.1.2 power envelope based control

coordination of the CEM based on limitations to the device Note 1 to entry: The CEM can set minimum and maximum values for the power that shall not be exceeded by the device.

3.1.3 power profile based control

control type where coordination from the CEM is based on profile modification, including concepts of sequence shifting, sequence selection

3.1.4 operation mode based control

control type where the resource manager offers the CEM multiple operation modes that the CEM could choose from Note 1 to entry: The behaviour of the device will be modified by selecting operation modes.

3.1.5 fill rate based control

control type based on measurements indicating the fill level and the fill rate

3.1.6 demand driven based control

control type where the CEM can decide how a given demand should be fulfilled

3.1.7 resource manager

RM function that exclusively represents a logical group of devices or a single smart device, and is responsible for sending unambiguous instructions to the logical group of devices or to a single device, typically using a device-specific protocol Note 1 to entry: In the context of this document the resource manager manages the energy flexibility of a logical group of devices or a single smart device.

[SOURCE: IEC 63402-1:2025 [3], 3.1.9]

3.1.8 role

categorization of the behaviour of a participant by its capabilities related to energy management, each participant at least supporting one

3.1.9 S1 communication

interface between CEM and energy management gateway

3.1.10 S2 communication

interface between CEM and resource manager

3.1.11 smart grid

electric power system that utilizes information exchange and control technologies, distributed computing and associated sensors and actuators, for purposes such as:

  • to integrate the behaviour and actions of the network users and other stakeholders,
  • to efficiently deliver sustainable, economic and secure electricity supplies

3.1.12 smart grid operator

instance requesting energy profiles from the CEM in order to keep the grid stable and reliable

3.1.13 time slot

fixed period of time with a specific duration

3.1.14 use case

case that describes interactions between an actor and another actor or a system to achieve a specific goal, either very abstract or very detailed Note 1 to entry: The use case can be nested.

3.1.15 user

either a person (e.g. installer or resident) or a surrogate service

3.1.16 prosumer

household or device that produces and consumes energy of the same commodity [SOURCE: IEC 60050-617:2009 [4], 617-02-16, modified - Replacement of "network user" with "household or device"; addition of "of the same commodity".]

3.1.17 single application smart system

SASS group of devices having a communication interface for a single application such as heating or lighting, that consume, produce or store energy (or a combination thereof) and that can be controlled by a resource manager for the purpose of energy management [SOURCE: IEC 63402-1:2025 [3], 3.1.13]

3.1.18 home and building electronic system

building automation control system HBES BACS logical group of devices which uses a multi-application communication system where the functions are distributed and linked through a common communication process EXAMPLE Management of lighting, heating, energy, water, fire alarms, blinds, different forms of security, etc. Note 1 to entry: HBES and BACS is used in homes and buildings plus their surroundings. Functions of the system are, for example: switching, open loop controlling, closed loop controlling, monitoring and supervising. Note 2 to entry: In literature, HBES or BACS can be referred also as "home control system or network", "home electronic systems", "building automation systems", etc.

[SOURCE: IEC 63402-1:2025 [3], 3.1.6]

3.1.19 abnormal condition

situation in which a Resource Manager is sacrificing user comfort when requested by the CEM

3.2 Abbreviated terms

AC Alternating current API Application Programmable Interface BACS Building Automation Control Systems CEM Customer Energy Management CHP Combined Heat and Power DC Direct current DDBC Demand Driven Based Control DSO Distribution System Operator EM Energy Management EMG Energy Management Gateway EV Electric Vehicle FRBC Fill Rate Based Control HBES Home and Building Electronic Systems HMI Human-Machine Interface I/F Interface M/O Mandatory / Optional M Mandatory O Optional OMBC Operation Mode Based Control PEBC Power Envelope Based Control PPBC Power Profile Based Control PV Photovoltaics RM Resource Manager RTP Real Time Pricing SASS Single Application Smart System SG Smart Grid TBEM Tariff Based Energy Management TOU Time Of Use 95PPR 95 Percent Probability Range 68PPR 68 Percent Probability Range

4 Energy management

4.1 Architectural overview

In IEC 63402-1 [5], the system architecture of the Smart Grid premises side is described in Figure 1. It includes the common interface between the equipment in the home or building, referred to as the Customer Energy Manager (CEM), and the Smart Grid (SG), referred to as the Energy Management Gateway (EMG). The data exchange between the EMG and the CEM is referred to as the S1 data exchange whereas the data exchange between the CEM and the Resource Manager on the premises side is referred to as the S2 data exchange.

Figure 1 – Architectural overview of Premises smart grid system Although the communication specified in this document mainly refers to S2 Communication, data that will be transmitted via S1 shall be considered as well. However, this document does not specify S1 Communication.

4.2 Description

A HBES/BACS/SASS or (Smart) device is usually purchased to fulfil a goal of the end user of the device or devices. For example, the goal of the end user of an electric boiler is to have hot tap water, and the goal of the end user of a heat pump is to have a comfortable room temperature. Meeting these goals is what is defined as user comfort. Although these goals shape the behaviour of a Smart Device, they do not completely define it. There might be multiple ways in which the goal of the end user can be achieved. For example, when there is still enough hot water in the electric boiler, the heating of the water could be postponed. In other words, there is some flexibility in achieving the goal of the end user. This is illustrated by Figure 2.

A battery or electric vehicle has a particular target state of charge at a particular moment in time. There are multiple ways to achieve this target, each with their own associated power profile. While all power profiles achieve the target state, these profiles can have a big impact on the power grid. Influencing how a device achieves its targets is what is defined as Energy Management. However, not all HBES/BACS/SASS or (Smart) devices have an explicit goal. For example, the sole purpose of a stationary battery can be to perform Energy Management; there is no other goal from the end user.

Figure 2 – Example of how different power profiles can achieve the same target state Energy Management always involves one or multiple types of energy which are exchanged with the grid, such as electricity (exchanged with a power grid), natural gas (exchanged with a gas grid) or heat (exchanged with a heat grid). These types of energy can be interconnected in the behaviour of the device.

For example, a (micro) CHP typically consumes natural gas, but at the same time produces electricity. For Energy Management purposes, it is necessary to know the behaviour of HBES or BACS or SASS or (Smart) devices with respect to these types of energy. These different energy types that are exchanged with a grid are referred to as commodities.

4.3 Energy management roles

4.3.1 General

In the S2 ecosystem, there are multiple entities fulfilling roles. This subclause gives an overview of these roles and gives concrete examples. Each role assumes a specific functionality and behaviour for a specific Commodity and is attributed to the entity by the entity itself. Entities referred to with roles are defined as EM (Energy Management) Participants. EM participants can fulfil one or multiple of these roles:

  • energy management;
  • energy producer;
  • energy consumer;
  • energy storage.
4.3.2 Energy producer role
4.3.2.1 Description

An energy producer is an EM participant that produces energy. It can operate under specific capabilities and constraints such as additional costs or the maximum amount of energy. As other EM participants, especially the CEM, need to know these capabilities and constraints, each energy producer shall provide a control type that contains those capabilities and constraints.

In general, all energy producers are categorized by their flexibility of energy production. Controlled producers are able to adapt their production whereas uncontrolled producers do not have that capability.

4.3.2.2 Controlled producers

Controlled producers can adjust the amount of energy they are producing according to their capabilities and constraints (e.g. max power). They shall be able to communicate the flexibility of energy production behaviour to the CEM, which in turn will send instructions to trigger changes.

4.3.2.3 Uncontrolled producers

Uncontrolled producers are those energy generating EM participants that do not offer a way to influence their mode of operation and thus cannot offer flexibility of power to the CEM. Photovoltaics can be an example of an uncontrolled producer, if for example the inverter does not offer any curtailment functionality. In case such curtailment options are available, the device should expose the controlled producer role. This example shows that, ultimately, it is not the type of device but its feature set that determines which role (controlled or uncontrolled producer) applies.

Additionally, uncontrolled producers will typically be less predictable than controlled producers, because they offer much less control over when they are able to operate in a specific range of their operational parameters. In those cases, it is especially important for the CEM that uncontrolled producers can provide a power forecast of expected power levels and their probabilistic variations.

4.3.3 Energy consumer role
4.3.3.1 Description

All EM participants that consume energy and utilize the provided energy to conduct some form of work are grouped as energy consumers. The fed energy is thus transformed to work, heat, etc. and can generally not be regained from the EM participant. This role includes standard home EM participants that participate actively in the EM network. Examples include water heaters, air conditioner or electric vehicles.

Every energy consumer can support the CEM by providing measurements, forecasts or control options, or both.

4.3.3.2 Water heater

A water heater is an EM participant that utilizes power to heat water. Flow heaters are heating water while it flows through and thus need to react on demand and are out of scope here. Water heaters with storage capability form the relevant use case from a demand side management perspective as they can operate in flexible boundaries to keep the stored water at a given level and temperature.

Water heaters are usually categorized by their maximum capacity in litres and the energy they need to heat water and to keep it at a given temperature. During operation time, the operational mode of the water heater is influenced by the water capacity and the minimum temperature required for the stored water.

Depending on the use of water heaters, the needed energy for heating water as well as the possibility to store hot water, water heaters are well suited to support efficient energy management.

4.3.3.3 Air condition

Air conditions are EM participants that utilize energy to cool down the air in a building. In contrast to water heaters, they typically do not have any storage capabilities themselves, but the room can be used as a buffer if a certain bandwidth in temperature is allowed. In this way, an air condition is also able to shift the power load in time in order to fulfil energy management requirements.

4.3.4 Energy storage role
4.3.4.1 Description

Furthermore, EM participants that can store energy play an important role in managing energetic environments as they are able to take energy in when it is abundant (or cheap) and release energy when it is scarce (or expensive). It shall be noted that this capability comes with consequences, e.g. storing energy requires more energy than what can be released at a later point. Every energy storage shall be able to declare its storage capacity including any consequences.

4.3.4.2 Stationary battery

Batteries are the standard EM participants when it comes to storing electricity. They are available with various capacities and can greatly contribute to balancing loads for premises, on grid level or in other environments.

While a battery is mainly defined by its capacity, charging time, required current and efficiency (ratio of consumed energy to released energy), which also play an important role in utilizing this EM participant optimally.

4.3.4.3 Electric vehicle

In addition to fixed batteries installed at a fixed location, mobile batteries (usually stored in electric vehicles) shall be considered as well.

Mobile batteries share all properties and operational parameters of stationary batteries, however, they have the added property of mobility, which means a mobile battery can appear in or disappear from a system at any point in time. They are thus less reliable than stationary batteries.

Furthermore, to use mobile batteries to optimize the utilization of energy in a system, the mobility requirements shall be considered, i.e. an electric vehicle shall be charged at a given (scheduled) time and should sometimes not be drained below a certain level, which would render the vehicle immobile.

5 Resource manager

The resource manager has a gateway function with embedded intelligence. It is a software component that represents a single energy flexibility. This document does not define where the resource manager runs physically. This could for example be on the smart device itself, on a separate device or in the environment of the manufacturer (e.g., cloud services). The resource manager connects on one side with the CEM using S2, and on the other side with a HBES or BACS or SASS or (smart) device. How the resource manager communicates with the HBES or BACS or SASS or (smart) device is out of scope for this document. For example, when a resource manager is implemented on the smart device itself, a local API can be used. It could also communicate through another device or a domain specific protocol.

...

Contents

  • 1 Domaine d'application
  • 2 Références normatives
  • 3 Termes, définitions et termes abrégés
  • 3.1 Termes et définitions
  • 3.1.1 gestionnaire d'énergie client
  • 3.1.2 contrôle fondé sur une enveloppe de puissance
  • 3.1.3 contrôle fondé sur un profil de puissance
  • 3.1.4 contrôle fondé sur le mode de fonctionnement
  • 3.1.5 contrôle fondé sur le taux de remplissage
  • 3.1.6 contrôle piloté par la demande
  • 3.1.7 gestionnaire de ressources
  • 3.1.8 rôle
  • 3.1.9 communication S1
  • 3.1.10 communication S2
  • 3.1.11 réseau intelligent
  • 3.1.12 opérateur de réseau intelligent
  • 3.1.13 intervalle de temps
  • 3.1.14 cas d'utilisation
  • 3.1.15 utilisateur
  • 3.1.16 prosommateur
  • 3.1.17 système intelligent pour application unique
  • 3.1.18 système électronique pour les foyers domestiques et les bâtiments
  • 3.1.19 condition anormale
  • 3.2 Termes abrégés
  • 4 Gestion d'énergie
  • 4.1 Vue d'ensemble architecturale
  • 4.2 Description
  • 4.3 Rôles Gestion d'énergie
  • 5 Gestionnaire de ressources
  • 6 Gestionnaire d'énergie client (CEM)
  • 6.1 Généralités
  • 6.2 Optimisation locale
  • 6.3 Contrôle implicite
  • 6.4 Contrôle explicite
  • 6.5 Récapitulatif
  • 7 Concepts relatifs à la gestion d'énergie
  • 7.1 Généralités
  • 7.2 Philosophie de conception
  • 7.3 Condition anormale
  • 7.4 Mesurages de puissance
  • 7.5 Prévisions de puissance
  • 7.6 Types de contrôles
  • 8 Modèles de données de gestion de l'énergie
  • 8.1 Types de données de base
  • 8.2 Gestionnaire de ressources
  • 8.3 Prévision de puissance
  • 8.4 Types de contrôles
  • 8.5 Énumérations
  • 9 Communication
  • 9.1 Généralités
  • 9.2 Tâches génériques
  • 9.3 Tâches de contrôle fondé sur une enveloppe de puissance
  • 9.4 Tâches de contrôle fondé sur un profil de puissance
  • 9.5 Tâches de contrôle fondé sur le mode de fonctionnement
  • 9.6 Tâches de contrôle fondé sur le taux de remplissage
  • 9.7 Tâches de contrôle piloté par la demande
  • Annexe A
  • Bibliographie

INTRODUCTION Au cours des dernières décennies, la production d'énergie et ses modèles de consommation ont considérablement évolué. Bien que la production d'énergie centrale soit toujours prédominante, la tendance à la production répartie se distingue à la faveur d'un nombre croissant d'énergies renouvelables. Les capacités de production des sources d'énergie de substitution étant très fluctuantes, les opérateurs de réseau peuvent avoir des difficultés à maintenir un équilibre entre production et consommation d'énergie. Le maintien de la fiabilité du réseau est encore plus complexe compte tenu de la variation de la consommation et de la production d'énergie électrique du client lui-même (l'utilisation de véhicules électriques et les installations personnelles de production d'électricité, par exemple). Un réseau intelligent permet à l'opérateur de réseau d'être flexible et réactif. Cette réactivité utilise la communication entre les entités de consommation et de production d'énergie, qu'il s'agisse de maisons individuelles ou de grandes usines.

Le présent document décrit les différents aspects du réseau intelligent qui concernent plus particulièrement la partie "locaux" (foyer domestique ou bâtiment) du réseau intelligent. Elle décrit également l'interface commune entre le matériel installé dans les locaux et le réseau intelligent. Le présent document définit les aspects fondamentaux de l'interopérabilité sémantique de l'interface S2 et l'échange de données connexe entre un gestionnaire d'énergie client (CEM) et les gestionnaires de ressources à l'intérieur des locaux. Différents cas d'utilisation sont expliqués à l'Annexe A, qui aident à comprendre la philosophie du présent document.

Le présent document repose sur l'EN 50491-12-2 [1] qui a également servi de base à l'élaboration de l'ETSI TS 103 410-1, SAREF4ENER [2].

1 Domaine d'application

Le présent document spécifie les aspects fondamentaux de l'interopérabilité sémantique de l'interface S2 et l'échange de données connexe entre un CEM et les gestionnaires de ressources à l'intérieur des locaux. Il fournit un ensemble de modèles de données et de modèles d'interaction indépendant de la technologie afin de prévoir des applications de gestion de l'énergie à l'intérieur des locaux. Le présent document n'inclut pas:

  • les mappings vers les représentations de données concrètes (XML, JSON et apparentés);
  • les mappings vers des protocoles d'application pour l'envoi de messages;
  • les aspects relatifs à la sécurité.

La présente publication groupée d'efficacité énergétique est principalement destinée à être utilisée comme norme d'efficacité énergétique pour les produits mentionnés dans le domaine d'application, mais elle est également destinée à être utilisée par les CE dans le cadre de l'élaboration de publications concernant les produits compris dans les limites mentionnées dans le domaine d'application du présent document.

2 Références normatives

Les documents suivants sont cités dans le texte de sorte qu'ils constituent, pour tout ou partie de leur contenu, des exigences du présent document. Pour les références datées, seule l'édition citée s'applique. Pour les références non datées, la dernière édition du document de référence s'applique (y compris les éventuels amendements).

IEC TR 62746-2:2015, Systems interface between customer energy management system and the power management system - Part 2: Use cases and requirements (disponible en anglais seulement) IEC 63402-1, Efficacité énergétique - Systèmes de gestion d'énergie client - Partie 1:

Exigences générales et architecture ISO 4217, Codes pour la représentation des monnaies ISO 15118-20, Véhicules routiers - Interface de communication entre véhicule et réseau ème électrique - Partie 20: Exigences des couches réseau et application de 2 génération

3 Termes, définitions et termes abrégés

3.1 Termes et définitions

Pour les besoins du présent document, les termes et définitions de l'IEC 63402-1 ainsi que les suivants s'appliquent.

L'ISO et l'IEC tiennent à jour des bases de données terminologiques destinées à être utilisées en normalisation, consultables aux adresses suivantes:

  • IEC Electropedia: disponible à l'adresse https://www.electropedia.org/
  • ISO Online browsing platform: disponible à l'adresse https://www.iso.org/obp

3.1.1 gestionnaire d'énergie client

CEM fonction d'automatisation interne destinée à l'optimisation de la consommation, de la production et du stockage d'énergie dans les locaux selon les préférences du client faisant usage des marges de manœuvre internes et reposant habituellement sur des informations externes obtenues par le biais de la passerelle de gestion d'énergie et éventuellement d'autres sources de données Note 1 à l'article: L'abréviation "CEM" est dérivée du terme anglais développé correspondant "Customer Energy Manager".

[SOURCE: IEC 63402-1:2025 [3], 3.1.1]

3.1.2 contrôle fondé sur une enveloppe de puissance

coordination du CEM en fonction des limitations liées à l'appareil Note 1 à l'article: Le CEM peut définir des valeurs de puissance minimale et maximale que l'appareil ne doit pas dépasser.

3.1.3 contrôle fondé sur un profil de puissance

type de contrôle dans lequel la coordination à partir du CEM repose sur un profil corrigé, y compris les concepts de déplacement de séquence et de sélection de séquence

3.1.4 contrôle fondé sur le mode de fonctionnement

type de contrôle dans lequel le gestionnaire de ressources procure au CEM plusieurs modes de fonctionnement parmi lesquels il peut faire son choix Note 1 à l'article: Le comportement de l'appareil varie en fonction des modes de fonctionnement choisis.

3.1.5 contrôle fondé sur le taux de remplissage

type de contrôle fondé sur les mesurages qui indiquent le niveau de remplissage et le taux de remplissage

3.1.6 contrôle piloté par la demande

type de contrôle dans lequel le CEM peut décider de la façon dont il convient de satisfaire à une demande donnée

3.1.7 gestionnaire de ressources

RM fonction qui représente exclusivement un groupe logique d'appareils ou un seul appareil intelligent, chargé de l'envoi d'instructions non ambiguës au groupe logique d'appareils ou à un seul appareil, généralement à l'aide d'un protocole propre à l'appareil Note 1 à l'article: Dans le contexte du présent document, le gestionnaire de ressources gère la flexibilité énergétique d'un groupe logique d'appareils ou d'un seul appareil intelligent. [SOURCE: IEC 63402-1:2025 [3], 3.1.9]

3.1.8 rôle

catégorisation du comportement d'un participant en fonction de ses capacités en matière de gestion de l'énergie, chaque participant en prenant en charge au moins une

3.1.9 communication S1

interface entre le CEM et la passerelle de gestion d'énergie

3.1.10 communication S2

interface entre le CEM et le gestionnaire de ressources

3.1.11 réseau intelligent

réseau d'énergie électrique qui utilise les technologies d'échange d'information et de commande, l'informatique distribuée et les capteurs et actionneurs associés, pour des objectifs tels que:

  • intégrer le comportement et les actions des utilisateurs du réseau et des autres parties prenantes,
  • fournir efficacement une alimentation en électricité durable, économique et sûre

3.1.12 opérateur de réseau intelligent

instance qui demande les profils énergétiques auprès du CEM afin de maintenir la stabilité et la fiabilité du réseau

3.1.13 intervalle de temps

laps de temps fixe d'une durée spécifique

3.1.14 cas d'utilisation

cas qui décrit les interactions entre un acteur et un autre acteur ou système afin d'atteindre un objectif spécifique, très abstrait ou très détaillé Note 1 à l'article: Les cas d'utilisation peuvent être imbriqués.

3.1.15 utilisateur

personne (un installateur ou un résident, par exemple) ou service de remplacement

3.1.16 prosommateur

ménage ou appareil qui produit et consomme l'énergie du même produit de base [SOURCE: IEC 60050-617:2009 [4], 617-02-16, modifié – "utilisateur du réseau" a été remplacé par "ménage ou appareil"; "du même produit de base" a été ajouté.]

3.1.17 système intelligent pour application unique

SASS groupe d'appareils ayant une interface de communication pour une seule application telle que le chauffage ou l'éclairage, qui consomme et/ou produit et/ou stocke de l'énergie et qui peut être contrôlé par un gestionnaire de ressources dans le cadre de la gestion d'énergie Note 1 à l'article: L'abréviation "SASS" est dérivée du terme anglais développé correspondant "Single Application Smart System".

[SOURCE: IEC 63402-1:2025 [3], 3.1.13]

3.1.18 système électronique pour les foyers domestiques et les bâtiments

système de gestion technique du bâtiment HBES SGTB groupe logique d'appareils qui utilise un système de communication multiapplication dont les fonctions sont réparties et liées par un processus de communication commun EXEMPLE Gestion de l'éclairage, du chauffage, de l'énergie, de l'eau, des alarmes incendie, des stores, des différentes formes de sécurité, etc.

Note 1 à l'article: Le système HBES et SGTB est utilisé dans les foyers domestiques et les bâtiments, ainsi que leurs environnements immédiats. Les fonctions du système sont, par exemple, la commutation, l'asservissement en circuit ouvert ou fermé, la surveillance et la supervision.

Note 2 à l'article: Dans les ouvrages de référence, le HBES ou SGTB peut également être appelé "système ou réseau domestique de commande", "systèmes électroniques pour les foyers domestiques", "systèmes immotiques", etc.

Note 3 à l'article: L'abréviation "HBES" est dérivée du terme anglais développé correspondant "Home and Building Electronic System".

[SOURCE: IEC 63402-1:2025 [3], 3.1.6]

3.1.19 condition anormale

situation dans laquelle un gestionnaire de ressources doit sacrifier le confort de l'utilisateur lorsque le CEM le demande

3.2 Termes abrégés

CA Courant alternatif API (Application Programmable Interface) Interface de programmation SGTB Système de gestion technique du bâtiment CEM (Customer Energy Management) Gestionnaire d'énergie client CHP (Combined Heat and Power) Production combinée de chaleur et d'énergie électrique CC Courant continu DDBC (Demand Driven Based Control) Contrôle piloté par la demande DSO (Distribution System Operator) Opérateur de réseau de distribution EM (Energy Management) Gestion d'énergie EMG (Energy Management Gateway) Passerelle de gestion d'énergie VE Véhicule électrique FRBC (Fill Rate Based Control) Contrôle fondé sur le taux de remplissage HBES (Home and Building Electronic Systems) Systèmes électroniques pour les foyers domestiques et les bâtiments IHM Interface homme-machine I/F Interface O/F Obligatoire/Facultatif O Obligatoire F Facultatif OMBC (Operation Mode Based Control) Contrôle fondé sur le mode de fonctionnement PEBC (Power Envelope Based Control) Contrôle fondé sur une enveloppe de puissance PPBC (Power Profile Based Control) Contrôle fondé sur un profil de puissance PV Photovoltaïque RM (Resource Manager) Gestionnaire de ressources RTP (Real Time Pricing) Tarification en temps réel SASS (Single Application Smart System) Système intelligent pour application unique SG (Smart Grid) Réseau intelligent TBEM (Tariff Based Energy Management) Gestion de l'énergie fondée sur les tarifs TOU (Time Of Use) Temps d'utilisation 95PPR (95 Percent Probability Range) Plage de probabilité de 95 pour cent 68PPR (68 Percent Probability Range) Plage de probabilité de 68 pour cent

4 Gestion d'énergie

4.1 Vue d'ensemble architecturale

Dans l'IEC 63402-1 [5], l'architecture du réseau intelligent côté locaux est représentée à la Figure 1. Elle décrit également l'interface commune entre le matériel installé dans le foyer domestique/le bâtiment, appelé "gestionnaire d'énergie client (CEM)", et le réseau intelligent, appelé "passerelle de gestion d'énergie (EMG)". La communication entre l'EMG et le CEM est appelée "communication S1", alors que la communication entre le CEM et le gestionnaire de ressources côté locaux est appelée "communication S2".

Figure 1 – Vue d'ensemble architecturale du réseau intelligent dans les locaux Même si la communication spécifiée dans le présent document fait principalement référence à la communication S2, les données amenées à être transmises par l'intermédiaire de S1 doivent également être prises en considération. Toutefois, le présent document ne spécifie pas la communication S1.

4.2 Description

Un HBES/SGTB/SASS ou un appareil (intelligent) est en général acheté pour permettre à l'utilisateur final de l'appareil ou des appareils d'atteindre un objectif. Par exemple, l'objectif de l'utilisateur final d'une chaudière électrique est d'obtenir de l'eau du robinet chaude, et l'objectif de l'utilisateur final d'une pompe à chaleur est d'atteindre une température ambiante confortable. L'atteinte de ces objectifs est définie comme étant le confort de l'utilisateur. Même si ces objectifs façonnent le comportement d'un appareil intelligent, ils ne le définissent pas complètement. L'utilisateur final peut atteindre un objectif de plusieurs façons. Par exemple, si la chaudière électrique contient toujours suffisamment d'eau chaude, le chauffage de l'eau peut être reporté. En d'autres termes, l'atteinte de l'objectif de l'utilisateur final présente une certaine flexibilité. Ce concept est représenté à la Figure 2. Une batterie ou un véhicule électrique présente un état de charge cible particulier à un moment précis dans le temps. Il existe plusieurs façons d'atteindre cet objectif, chacune avec son propre profil de puissance associé. Lorsque tous les profils de puissance atteignent l'état cible, ils peuvent avoir une incidence importante sur le réseau de distribution d'électricité. La gestion d'énergie définit la manière dont un appareil atteint ses objectifs. Toutefois, tous les HBES/SGTB/SASS ou appareils (intelligents) n'ont pas d'objectif explicite. Par exemple, une

batterie stationnaire peut avoir pour seul objet de gérer l'énergie. Il n'y a aucun autre objectif pour l'utilisateur final.

Figure 2 – Exemple de la manière dont différents profils de puissance peuvent atteindre le même état cible La gestion d'énergie implique toujours un ou plusieurs types d'énergies qui sont échangés avec le réseau, comme l'électricité (échangée avec un réseau de distribution d'électricité), le gaz naturel (échangé avec un réseau de distribution de gaz) ou la chaleur (échangée avec un réseau de distribution de chaleur). Ces types d'énergies peuvent être interconnectés dans le comportement de l'appareil.

Par exemple, une (micro) CHP consomme en général du gaz naturel, mais elle produit en même temps de l'électricité. Pour les besoins de la gestion d'énergie, il est nécessaire de connaître le comportement du HBES, du SGTB, du SAAS ou des appareils (intelligents) en ce qui concerne ces types d'énergies. Ces différents types d'énergies échangés avec un réseau sont appelés "produits de base".

4.3 Rôles Gestion d'énergie

4.3.1 Généralités

Dans l'écosystème S2, plusieurs entités exercent des rôles. Le présent paragraphe donne une vue d'ensemble de ces rôles ainsi que des exemples concrets. Chaque rôle prend pour hypothèse une fonctionnalité et un comportement spécifiques pour un produit de base particulier, et est attribué à l'entité par l'entité elle-même. Les entités liées aux rôles sont appelées "participants à la gestion d'énergie" (EM). Les participants EM peuvent exercer un ou plusieurs de ces rôles:

  • gestion d'énergie;
  • producteur d'énergie;
  • consommateur d'énergie;
  • stockage d'énergie.
4.3.2 Rôle Producteur d'énergie
4.3.2.1 Description

Un producteur d'énergie est un participant EM qui produit de l'énergie. Il peut opérer dans le cadre de capacités et contraintes particulières (coûts supplémentaires ou quantité maximale d'énergie, par exemple). Étant donné que les autres participants EM, en particulier le CEM, ont besoin de connaître ces capacités et ces contraintes, chaque producteur d'énergie doit fournir un type de contrôle les contenant.

En règle générale, tous les producteurs d'énergie sont classés selon leur flexibilité en matière de production d'énergie. Les producteurs contrôlés sont en mesure d'adapter leur production, alors que les producteurs non contrôlés n'ont pas cette capacité.

4.3.2.2 Producteurs contrôlés

Les producteurs contrôlés peuvent ajuster la quantité d'énergie qu'ils produisent en fonction de leurs capacités et de leurs contraintes (puissance maximale, par exemple). Ils doivent être capables de communiquer la flexibilité du comportement de production d'énergie au CEM, qui en retour envoie des instructions pour déclencher les modifications.

4.3.2.3 Producteurs non contrôlés

Les producteurs non contrôlés sont des participants EM qui produisent de l'énergie. Ils n'offrent pas la possibilité d'influencer leur mode de fonctionnement et, de ce fait, ne peuvent pas procurer de flexibilité de puissance au CEM.

Le photovoltaïque peut être un exemple de producteur non contrôlé, si par exemple l'onduleur n'offre aucune fonctionnalité de réduction. Si de telles options de réduction sont disponibles, il convient que l'appareil joue le rôle de producteur contrôlé. Cet exemple démontre qu'en fin de compte, ce n'est pas le type de l'appareil mais son ensemble de fonctionnalités qui détermine le rôle (producteur contrôlé ou non contrôlé) à appliquer.

En outre, les producteurs non contrôlés sont généralement moins prévisibles que les producteurs contrôlés, car ils offrent beaucoup moins de contrôle sur le moment auquel ils sont en mesure de fonctionner dans une plage spécifique de leurs paramètres opérationnels. Dans ces cas, il est particulièrement important pour le CEM que les producteurs non contrôlés puissent fournir une prévision de puissance des niveaux de puissance prévus et de leurs variations probabilistes.

4.3.3 Rôle Consommateur d'énergie
4.3.3.1 Description

Tous les participants EM qui consomment de l'énergie et utilisent l'énergie fournie pour exécuter un certain travail sont des consommateurs d'énergie. L'énergie produite est donc transformée pour travailler, se chauffer, etc., et ne peut en général pas être reprise au participant EM. Ce rôle inclut les participants EM domestiques normalisés qui participent activement au réseau EM. Il s'agit, par exemple, des chauffe-eau, des climatiseurs ou des véhicules électriques.

Chaque consommateur d'énergie peut aider le CEM en fournissant des mesurages, des prévisions ou des options de contrôle, ou les deux.

4.3.3.2 Chauffe-eau

Un chauffe-eau est un participant EM qui utilise l'énergie pour chauffer l'eau. Les chauffe-eau instantanés chauffent l'eau au fur et à mesure de son écoulement et ont donc besoin de réagir à la demande. Ils ne relèvent pas du domaine d'application du présent document. Les chauffe-eau avec une capacité de stockage constituent le cas d'utilisation pertinent du point de vue de la gestion côté demande, car ils peuvent fonctionner dans des limites flexibles pour maintenir l'eau stockée à un niveau et une température donnés. Les chauffe-eau sont en général classés en fonction de leur capacité maximale en litres et de l'énergie dont ils ont besoin pour chauffer l'eau et la maintenir à une température donnée. Pendant la période de fonctionnement, le mode opérationnel du chauffe-eau est influencé par la capacité en eau et par la température minimale exigée de l'eau stockée. En fonction de l'utilisation des chauffe-eau, de l'énergie nécessaire pour chauffer l'eau et de la possibilité de stocker l'eau chaude, les chauffe-eau sont bien adaptés à une gestion d'énergie efficace.

...