Amendment 1 - Magnetic materials - Part 5: Permanent magnet (magnetically hard) materials - Methods of measurement of magnetic properties

Amendement 1 - Matériaux magnétiques - Partie 5: Aimants permanents (magnétiques durs) - Méthodes de mesure des propriétés magnétiques

General Information

Status
Published
Publication Date
15-Feb-2007
Drafting Committee
Current Stage
DELPUB - Deleted Publication
Completion Date
16-Apr-2015
Ref Project

Relations

Buy Standard

Standard
IEC 60404-5:1993/AMD1:2007 - Amendment 1 - Magnetic materials - Part 5: Permanent magnet (magnetically hard) materials - Methods of measurement of magnetic properties Released:2/16/2007 Isbn:2831890276
English and French language
11 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


NORME CEI
INTERNATIONALE
IEC
60404-5
INTERNATIONAL
STANDARD
AMENDEMENT 1
AMENDMENT 1
2007-02
Amendement 1
Matériaux magnétiques –
Partie 5:
Aimants permanents (magnétiques durs) –
Méthodes de mesure des propriétés magnétiques

Amendment 1
Magnetic materials –
Part 5:
Permanent magnet (magnetically hard) materials –
Methods of measurement of magnetic properties
© IEC 2007 Droits de reproduction réservés ⎯ Copyright - all rights reserved
International Electrotechnical Commission, 3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, Switzerland
Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmail@iec.ch Web: www.iec.ch
CODE PRIX
F
Commission Electrotechnique Internationale
PRICE CODE
International Electrotechnical Commission
МеждународнаяЭлектротехническаяКомиссия
Pour prix, voir catalogue en vigueur
For price, see current catalogue

– 2 – 60404-5 Amend. 1 © CEI:2007
AVANT-PROPOS
Le présent amendement a été établi par le comité d'études 68 de la CEI: Matériaux
magnétiques tels qu'alliages et aciers.
Le texte de cet amendement est issu des documents suivants:
FDIS Rapport de vote
68/331/FDIS 68/340/RVD
Le rapport de vote indiqué dans le tableau ci-dessus donne toute information sur le vote ayant
abouti à l'approbation de cet amendement.
Le comité a décidé que le contenu de cet amendement et de la publication de base ne sera
pas modifié avant la date de maintenance indiquée sur le site web de la CEI sous
"http://webstore.iec.ch" dans les données relatives à la publication recherchée. A cette date,
la publication sera
• reconduite,
• supprimée,
• remplacée par une édition révisée, ou
• amendée.
_____________
Page 2
SOMMAIRE
Ajouter la ligne suivante à la fin:
Annexe B (informative) Influence de la température ambiante sur les résultats de mesures

Page 8
1.2 Références normatives
Les documents de référence suivants sont indispensables pour l'application du présent
document. Pour les références datées, seule l'édition citée s'applique. Pour les références
non datées, la dernière édition du document de référence s'applique (y compris les éventuels
amendements).
Supprimer les dates aux 4 références datées.

60404-5 Amend. 1 © IEC:2007 – 3 –
FOREWORD
This amendment has been prepared by IEC technical committee 68: Magnetic alloys and steels.
The text of this amendment is based on the following documents:
FDIS Report on voting
68/331/FDIS 68/340/RVD
Full information on the voting for the approval of this amendment can be found in the report on
voting indicated in the above table.
The committee has decided that the contents of this amendment and the base publication will
remain unchanged until the maintenance result date indicated on the IEC web site under
"http://webstore.iec.ch" in the data related to the specific publication. At this date, the
publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
_____________
Page 3
CONTENTS
Add the following line at the end:
Annex B (informative) Influence of the ambient temperature on measurement results

Page 9
1.2 Normative references
The following referenced documents are indispensable for the application of this document. For
dated references, only the edition cited applies. For undated references, the latest edition of the
referenced document (including any amendments) applies.
Delete the dates to the 4 dated references.

– 4 – 60404-5 Amend. 1 © CEI:2007
Page 18
8 Détermination de la courbe de désaimantation
ème
Insérer à la fin de la première phrase du 3 alinéa:
«(voir Annexe B) »
ème
et après le 3 alinéa la note suivante:
« NOTE Pour les méthodes de mesures (non normatives) à températures élevées, voir la CEI 61807. »
8.1 Principe de la détermination de la courbe de désaimantation, l’éprouvette étant
aimantée dans l'électro-aimant
Ajouter à la fin du premier alinéa:
« (voir Figure 2) »
Page 20
8.2 Principe de la détermination de la courbe de désaimantation, l’éprouvette étant
aimantée dans une bobine supraconductrice ou un banc d’aimantation à
impulsion
Ajouter la phrase suivante à la fin du premier alinéa:
« Le champ magnétique nécessaire à la saturation dépend du type du matériau magnétique
de l’éprouvette et de sa coercitivité. »
ème
Insérer la note suivante après le 4 alinéa:
« NOTE Le champ magnétique qu’on peut obtenir en utilisant un électro-aimant peut ne pas être suffisant pour
mesurer les valeurs très élevées de la coercitivité relative à la polarisation magnétique, H . Dans un tel cas, la
cJ
mesure peut être réalisée en utilisant d’autres méthodes telles qu’une bobine supraconductrice ou la méthode du
champ impulsionnel (voir le CEI 62331). Toutefois, ces méthodes ne sont pas normatives. »

9.2 Produit (BH)
max
A la page 22, à la fin de a), remplacer « (voir Figure 2) » par:
« (voir Figure 3) »
9.4 Détermination de la droite de recul et de la perméabilité de recul
Dans la première phrase, remplacer « (Figure 3) » par:
« (Figure 4) »
60404-5 Amend. 1 © IEC:2007 – 5 –
Page 19
8 Determination of the demagnetization curve
rd
Insert at the end of the first sentence of the 3 paragraph:
“(see Annex B)”
rd
and after the 3 paragraph the following note:
“NOTE For the methods of (non-normative) measurements at elevated temperatures, see IEC 61807”.
8.1 Principle of determination of the demagnetization curve, test specimen magnetized
in the electromagnet
Add at the end of the first paragraph:
“(see Figure 2)”
Page 21
8.2 Principle of determination of the demagnetization curve, test specimen magnetized
in a superconducting coil or pulse magnetizer
Add the following sentence at the end of the first paragraph:
“The magnetic field strength required for saturation depends on the type of the magnetic
material of the test specimen and on its coercivity.”
th
Insert the foll
...

Questions, Comments and Discussion