ISO/IEC 29145-2:2014
(Main)Information technology - Wireless beacon-enabled energy efficient mesh network (WiBEEM) for wireless home network services - Part 2: MAC layer
Information technology - Wireless beacon-enabled energy efficient mesh network (WiBEEM) for wireless home network services - Part 2: MAC layer
ISO/IEC 29145-2:2014(E) specifies the MAC of the WiBEEM (Wireless beacon-enabled energy efficient mesh network) protocol for wireless home network services that supports a low power-consuming wireless mesh network as well as device mobility and QoS.
General Information
Standards Content (Sample)
ISO/IEC 29145-2
Edition 1.0 2014-03
INTERNATIONAL
STANDARD
Information technology – Wireless beacon-enabled energy efficient mesh
network (WiBEEM) standard for wireless home network services –
Part 2: MAC layer
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form
or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from
either IEC or IEC's member National Committee in the country of the requester. If you have any questions about
ISO/IEC copyright or have an enquiry about obtaining additional rights to this publication, please contact the address
below or your local IEC member National Committee for further information.
IEC Central Office Tel.: +41 22 919 02 11
3, rue de Varembé Fax: +41 22 919 03 00
CH-1211 Geneva 20 info@iec.ch
Switzerland www.iec.ch
About the IEC
The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes
International Standards for all electrical, electronic and related technologies.
About IEC publications
The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the
latest edition, a corrigenda or an amendment might have been published.
IEC Catalogue - webstore.iec.ch/catalogue Electropedia - www.electropedia.org
The stand-alone application for consulting the entire The world's leading online dictionary of electronic and
bibliographical information on IEC International Standards, electrical terms containing more than 30 000 terms and
Technical Specifications, Technical Reports and other definitions in English and French, with equivalent terms in 14
documents. Available for PC, Mac OS, Android Tablets and additional languages. Also known as the International
iPad. Electrotechnical Vocabulary (IEV) online.
IEC publications search - www.iec.ch/searchpub IEC Glossary - std.iec.ch/glossary
The advanced search enables to find IEC publications by a More than 55 000 electrotechnical terminology entries in
variety of criteria (reference number, text, technical English and French extracted from the Terms and Definitions
committee,…). It also gives information on projects, replaced clause of IEC publications issued since 2002. Some entries
and withdrawn publications. have been collected from earlier publications of IEC TC 37,
77, 86 and CISPR.
IEC Just Published - webstore.iec.ch/justpublished
Stay up to date on all new IEC publications. Just Published IEC Customer Service Centre - webstore.iec.ch/csc
details all new publications released. Available online and If you wish to give us your feedback on this publication or
also once a month by email. need further assistance, please contact the Customer Service
Centre: csc@iec.ch.
ISO/IEC 29145-2
Edition 1.0 2014-03
INTERNATIONAL
STANDARD
Information technology – Wireless beacon-enabled energy efficient mesh
network (WiBEEM) standard for wireless home network services –
Part 2: MAC layer
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
PRICE CODE
U
ICS 35.200 ISBN 978-2-8322-1449-7
– 2 – ISO/IEC 29145-2 © ISO/IEC 2014
CONTENTS
FOREWORD . 5
INTRODUCTION . 6
1 Scope . 7
2 Normative reference . 7
3 Terms, definitions and abbreviations . 7
3.1 Terms and definitions . 7
3.2 Abbreviations . 8
3.3 Conventions . 9
4 Conformance . 10
5 Overview of the WiBEEM technology . 10
6 MAC layer specifications . 10
6.1 General . 10
6.2 MAC layer service specifications . 10
6.2.1 Service overview . 10
6.2.2 MAC data service . 11
6.2.3 MAC management service . 17
6.2.4 Association primitives . 17
6.2.5 Disassociation primitives . 22
6.2.6 Beacon notification primitive . 24
6.2.7 Primitives for reading PIB attributes . 27
6.2.8 RAP management primitives . 28
6.2.9 Primitives for orphan notification . 31
6.2.10 Primitives for resetting the MAC layer . 34
6.2.11 Primitives for specifying the receiver enable time . 35
6.2.12 Primitives for channel scanning . 37
6.2.13 Communication status primitive . 39
6.2.14 Primitives for writing MAC PIB attributes . 41
6.2.15 Primitives for updating the superframe configuration . 42
6.2.16 Primitives for synchronising with a WRC . 45
6.2.17 Primitives for requesting data from a WRC . 47
6.3 MAC frame formats . 49
6.3.1 General . 49
6.3.2 General MAC frame format . 50
6.3.3 Beacon frame format . 52
6.3.4 MAC command frame format . 52
Bibliography . 62
Figure 1 – MAC layer structure . 11
Figure 2 – Message sequence chart describing the MAC data service . 16
Figure 3 – Message sequence chart for association . 22
Figure 4 – Message sequence chart for disassociation . 24
Figure 5 – Message sequence chart for RAP allocation initiated by a device . 31
Figure 6 – Message sequence chart for RAP deallocation initiated by a device and the
WMC . 31
ISO/IEC 29145-2 © ISO/IEC 2014 – 3 –
Figure 7 – Beacon lost (orphan notification) message sequence chart . 33
Figure 8 – Message sequence chart for updating the superframe configuration . 45
Figure 9 – Message sequence chart for synchronising to a WRC in a beacon-enabled
WPAN . 47
Figure 10 – Message sequence chart for requesting data from the WRC. 49
Figure 11 – General MAC frame format . 50
Figure 12 – Beacon frame format . 52
Table 1 – MLDE-DATA.request parameters . 12
Table 2 – MLDE-DATA.confirm parameters . 13
Table 3 – MLDE-DATA.indication parameters . 14
Table 4 – MLDE-ERASE.request parameters . 15
Table 5 – MLDE-ERASE.confirm parameters . 16
Table 6 – Summary of the primitives accessed through the MLME-SAP . 17
Table 7 – MLME-ASSOCIATE.request parameters . 18
Table 8 – MLME-ASSOCIATE.indication parameters . 19
Table 9 – MLME-ASSOCIATE.response parameters . 20
Table 10 – MLME-ASSOCIATE.confirm parameters . 21
Table 11 – MLME-DISASSOCIATE.request parameters . 22
Table 12 – MLME-DISASSOCIATE.indication parameters . 23
Table 13 – MLME-DISASSOCIATE.confirm parameters . 24
Table 14 – MLME-BEACON-NOTIFY.indication parameters . 25
Table 15 – Elements of mesh descriptor . 26
Table 16 – MLME-READ-MIB.request parameters . 27
Table 17 – MLME-READ-MIB.confirm parameters . 28
Table 18 – MLME- RAP-MANAGEMENT.request parameters . 29
Table 19 – MLME-RAP-MANAGEMENT.confirm parameters . 29
Table 20 – MLME-RAP-MANAGEMENT.indication parameters . 30
Table 21 – MLME-BEACON-LOST.indication parameters . 32
Table 22 – MLME-BEACON-LOST.indication parameters . 33
Table 23 – MLME-RESET.request parameters . 34
Table 24 – MLME-RESET.confirm parameters . 35
Table 25 – MLME-RX-ON.request parameters . 35
Table 26 – MLME-RX-ON.confirm parameters . 36
Table 27 – MLME-SCAN.request parameters . 37
Table 28 – MLME-SCAN.confirm parameters . 39
Table 29 – MLME-COMM-RESULT.indication parameters . 40
Table 30 – MLME-WRITE-MIB.request parameters . 41
Table 31 – MLME-WRITE-MIB.confirm parameters . 42
Table 32 – MLME-START.request parameters . 43
Table 33 – MLME-START.confirm parameters . 44
Table 34 – MLME-SYNC.request parameters . 45
Table 35 – MLME-SYNC-LOSS.indication parameters . 46
– 4 – ISO/IEC 29145-2 © ISO/IEC 2014
Table 36 – MLME-INDIRECT-COMM.request parameters . 48
Table 37 – MLME-INDIRECT-COMM.confirm parameters . 48
Table 38 – MAC command frame . 53
Table 39 – Association request command . 53
Table 41 – Association response command . 54
Table 42 – Association status field . 55
Table 43 – Disassociation notification command format . 55
Table 44 – Disassociation reason code . 56
Table 45 – Data request command format . 57
Table 46 – Mesh ID conflict notification command format . 57
Table 47 – Orphan notification command format . 58
Table 48 – Beacon request command format . 58
Table 49 – Co-ordinator realignment command format . 59
Table 50 – CFP request command
...