Alarm and electronic security systems - Part 11-5: Electronic access control systems - Open supervised device protocol (OSDP)

IEC 60839-11-5:2020 specifies the Open supervised device protocol (OSDP) for electronic access control systems. This includes communication settings, commands and replies between the ACU and the peripheral devices. It also includes a mapping of mandatory and optional requirements as per IEC 60839-11-1:2013 as covered by Annex.
This document applies to physical security only. Physical security prevents unauthorized personnel, attackers or accidental intruders from physically accessing a building, room, etc.

Comptage d'électricité - Echange de données pour la lecture des compteurs, le contrôle des tarifs et de la charge - Partie 51: Protocoles de couche application

Décrit une architecture de couche application utilisée pour communiquer avec les équipements de comptage. Le support physique et les protocoles de couches basses qui y sont associés dans un modèle réduit à 3 couches ne sont pas specifiés. Le protocole DLMS est couvert par la CEI 61334-4-41. C'est un Rapport technique de type 2.

Electricity metering - Data exchange for meter reading, tariff and load control - Part 51: Application layer protocols

General Information

Status
Published
Publication Date
07-Jul-2020
Current Stage
PPUB - Publication issued
Completion Date
08-Jul-2020

Buy Standard

Standard
IEC 60839-11-5:2020 - Alarm and electronic security systems - Part 11-5: Electronic access control systems - Open supervised device protocol (OSDP)
English language
85 pages
sale 15% off
Preview
sale 15% off
Preview
Technical report
IEC/TR2 62056-51:2001
English language
35 pages
sale 10% off
Preview
sale 10% off
Preview

e-Library read for
1 day

Standards Content (sample)

IEC 60839-11-5
Edition 1.0 2020-07
INTERNATIONAL
STANDARD
Alarm and electronic security systems –
Part 11-5: Electronic access control systems – Open supervised device protocol
(OSDP)
IEC 60839-11-5:2020-07(en)
---------------------- Page: 1 ----------------------
THIS PUBLICATION IS COPYRIGHT PROTECTED
Copyright © 2020 IEC, Geneva, Switzerland

All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form

or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from

either IEC or IEC's member National Committee in the country of the requester. If you have any questions about IEC

copyright or have an enquiry about obtaining additional rights to this publication, please contact the address below or

your local IEC member National Committee for further information.
IEC Central Office Tel.: +41 22 919 02 11
3, rue de Varembé info@iec.ch
CH-1211 Geneva 20 www.iec.ch
Switzerland
About the IEC

The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes

International Standards for all electrical, electronic and related technologies.
About IEC publications

The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the

latest edition, a corrigendum or an amendment might have been published.

IEC publications search - webstore.iec.ch/advsearchform Electropedia - www.electropedia.org

The advanced search enables to find IEC publications by a The world's leading online dictionary on electrotechnology,

variety of criteria (reference number, text, technical containing more than 22 000 terminological entries in English

committee,…). It also gives information on projects, replaced and French, with equivalent terms in 16 additional languages.

and withdrawn publications. Also known as the International Electrotechnical Vocabulary

(IEV) online.
IEC Just Published - webstore.iec.ch/justpublished

Stay up to date on all new IEC publications. Just Published IEC Glossary - std.iec.ch/glossary

details all new publications released. Available online and 67 000 electrotechnical terminology entries in English and

once a month by email. French extracted from the Terms and Definitions clause of

IEC publications issued since 2002. Some entries have been

IEC Customer Service Centre - webstore.iec.ch/csc collected from earlier publications of IEC TC 37, 77, 86 and

If you wish to give us your feedback on this publication or CISPR.
need further assistance, please contact the Customer Service
Centre: sales@iec.ch.
---------------------- Page: 2 ----------------------
IEC 60839-11-5
Edition 1.0 2020-07
INTERNATIONAL
STANDARD
Alarm and electronic security systems –
Part 11-5: Electronic access control systems – Open supervised device protocol
(OSDP)
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
ICS 13.320 ISBN 978-2-8322-8480-3

Warning! Make sure that you obtained this publication from an authorized distributor.

® Registered trademark of the International Electrotechnical Commission
---------------------- Page: 3 ----------------------
– 2 – IEC 60839-11-5:2020 © IEC 2020
CONTENTS

FOREWORD ........................................................................................................................... 8

INTRODUCTION ................................................................................................................... 10

1 Scope ............................................................................................................................ 11

2 Normative references .................................................................................................... 11

3 Terms, definitions and abbreviated terms ...................................................................... 11

3.1 Terms and definitions ............................................................................................ 11

3.2 Abbreviated terms ................................................................................................. 12

4 Overview ....................................................................................................................... 12

5 Communication settings................................................................................................. 13

5.1 Physical interface ................................................................................................. 13

5.2 Signaling ............................................................................................................... 13

5.3 Character encoding ............................................................................................... 13

5.4 Channel access .................................................................................................... 13

5.5 Multi-byte data encoding ....................................................................................... 13

5.6 Packet size limits .................................................................................................. 14

5.7 Timing................................................................................................................... 14

5.8 Message synchronization ...................................................................................... 14

5.9 Packet format ....................................................................................................... 15

5.10 Multi-part messages .............................................................................................. 17

5.10.1 General ......................................................................................................... 17

5.10.2 Multi-part message usage rules ..................................................................... 17

5.11 Smartcard handling ............................................................................................... 18

6 Commands .................................................................................................................... 19

6.1 General ................................................................................................................. 19

6.2 Poll request (osdp_POLL) ..................................................................................... 19

6.3 ID report request (osdp_ID) .................................................................................. 19

6.4 Peripheral device capabilities request (osdp_CAP) ............................................... 20

6.5 Local status report request (osdp_LSTAT) ............................................................ 20

6.6 Input status report request (osdp_ISTAT).............................................................. 20

6.7 Output status report request (osdp_OSTAT) ......................................................... 21

6.8 Reader status report request (osdp_RSTAT) ......................................................... 21

6.9 Output control command (osdp_OUT) ................................................................... 21

6.10 Reader LED control command (osdp_LED) ........................................................... 22

6.11 Reader buzzer control command (osdp_BUZ) ....................................................... 24

6.12 Reader text output command (osdp_TEXT) ........................................................... 25

6.13 Communication configuration command (osdp_COMSET) ..................................... 26

6.14 Scan and send biometric data (osdp_BIOREAD) ................................................... 27

6.15 Scan and match biometric template (osdp_BIOMATCH) ........................................ 28

6.16 Encryption key set (osdp_KEYSET) ...................................................................... 29

6.17 Challenge and secure session initialization request (osdp_CHLNG) ...................... 29

6.18 Server's random number and server cryptogram (osdp_SCRYPT) ......................... 29

6.19 Manufacturer specific command (osdp_MFG) ....................................................... 29

6.20 ACU receive size (osdp_ACURXSIZE) .................................................................. 30

6.21 Keep reader active (osdp_KEEPACTIVE).............................................................. 30

6.22 Abort current operation (osdp_ABORT) ................................................................. 31

6.23 Get PIV data (osdp_PIVDATA) .............................................................................. 31

---------------------- Page: 4 ----------------------
IEC 60839-11-5:2020 © IEC 2020 – 3 –

6.24 General authenticate (osdp_GENAUTH) ............................................................... 31

6.25 Authentication challenge (osdp_CRAUTH) ............................................................ 32

6.26 File transfer command (osdp_FILETRANSFER) .................................................... 33

6.27 Extended write data (osdp_XWR) ......................................................................... 33

6.27.1 General ......................................................................................................... 33

6.27.2 Mode set command ....................................................................................... 34

6.27.3 Mode-00 read setting ..................................................................................... 35

6.27.4 Mode specific command codes for XRW_MODE=1 ........................................ 35

6.27.5 Mode-01 transparent content send request .................................................... 35

6.27.6 Mode-01 connection done .............................................................................. 35

6.27.7 Mode-01 request secure PIN entry command ................................................. 36

6.27.8 Mode-01 smartcard scan ............................................................................... 37

7 Replies .......................................................................................................................... 37

7.1 General ................................................................................................................. 37

7.2 General acknowledge – Nothing to report (osdp_ACK) .......................................... 38

7.3 Negative acknowledge – Error response (osdp_NAK) ........................................... 38

7.4 Device identification report (osdp_PDID) ............................................................... 39

7.5 Device capabilities report (osdp_PDCAP) ............................................................. 40

7.6 Local status report (osdp_LSTATR) ...................................................................... 41

7.7 Input status report (osdp_ISTATR) ........................................................................ 41

7.8 Output status report (osdp_OSTATR) ................................................................... 41

7.9 Reader tamper status report (osdp_RSTATR) ....................................................... 42

7.10 Card data report, raw bit array (osdp_RAW) .......................................................... 42

7.11 Card data report, character array (osdp_FMT) ...................................................... 43

7.12 Keypad data report (osdp_KEYPAD) ..................................................................... 43

7.13 Communication configuration report (osdp_COM) ................................................. 44

7.14 Scan and send biometric data (osdp_BIOREADR) ................................................ 44

7.15 Scan and match biometric template (osdp_BIOMATCHR) ..................................... 45

7.16 Client's ID and client's random number (osdp_CCRYPT) ...................................... 45

7.17 Client cryptogram packet and the initial R-MAC (osdp_RMAC_I) ........................... 46

7.18 Manufacturer specific reply (osdp_MFGREP) ........................................................ 46

7.19 PD busy reply (osdp_BUSY) ................................................................................. 46

7.20 PIV data reply (osdp_PIVDATAR) ......................................................................... 46

7.21 osdp_GENAUTHR................................................................................................. 47

7.22 Response to challenge (osdp_CRAUTHR) ............................................................ 47

7.23 Manufacturer specific status reply (osdp_MFGSTATR) ......................................... 48

7.24 Manufacturer specific error reply (osdp_MFGERRR) ............................................. 48

7.25 File transfer status (osdp_FTSTAT) ...................................................................... 48

7.26 Extended read reply (osdp_XRD) .......................................................................... 49

7.26.1 General ......................................................................................................... 49

7.26.2 Mode specific reply codes for XRW_MODE=0 ................................................ 50

7.26.3 Mode-00 error reply (osdp_PR00ERROR)...................................................... 50

7.26.4 Mode setting report (osdp_PR00REQR)......................................................... 50

7.26.5 Card information report (osdp_PR00CIRR) .................................................... 51

7.26.6 Mode specific reply codes for XRW_MODE=1 ................................................ 51

7.26.7 Mode-01 NAK or error reply (osdp_PR01ERROR) ......................................... 52

7.26.8 Card present notification reply (osdp_PR01PRES)......................................... 52

7.26.9 Transparent card data reply (osdp_PR01SCREP) .......................................... 52

7.26.10 Secure PIN entry complete reply (osdp_PR01SPER) ..................................... 53

---------------------- Page: 5 ----------------------
– 4 – IEC 60839-11-5:2020 © IEC 2020

Annex A (normative) Command and reply code numbers commands ................................... 54

A.1 Commands ........................................................................................................... 54

A.2 Replies ................................................................................................................. 55

Annex B (normative) Function code definitions list ............................................................... 56

B.1 General ................................................................................................................. 56

B.2 Function code 1 – Contact status monitoring ......................................................... 56

B.3 Function code 2 – Output control .......................................................................... 57

B.4 Function code 3 – Card data format ...................................................................... 57

B.5 Function code 4 – Reader LED control .................................................................. 57

B.6 Function code 5 – Reader audible output .............................................................. 58

B.7 Function code 6 – Reader text output .................................................................... 58

B.8 Function code 7 – Time keeping ........................................................................... 58

B.9 Function code 8 – Check character support .......................................................... 58

B.10 Function code 9 – Communication security ........................................................... 59

B.11 Function code 10 – Receive bufferSize ................................................................. 59

B.12 Function code 11 – Largest combined message size ............................................. 59

B.13 Function code 12 – Smart card support ................................................................. 59

B.14 Function code 13 – Readers ................................................................................. 60

B.15 Function code 14 – Biometrics .............................................................................. 60

B.16 Function code 15 – Secure PIN entry support ....................................................... 60

B.17 Function code 16 – OSDP version ........................................................................ 60

Annex C (normative) CRC definition .................................................................................... 61

Annex D (normative) Encryption ........................................................................................... 64

D.1 Encryption method: OSDP-SC .............................................................................. 64

D.1.1 General ......................................................................................................... 64

D.1.2 Overview ....................................................................................................... 65

D.1.3 The process ................................................................................................... 65

D.1.4 Secure channel session connection sequence (SCS-CS) ............................... 65

D.1.5 Communication during a secure channel session ........................................... 67

D.1.6 SCS_16 PD->ACU ......................................................................................... 67

D.1.7 SCS_17 ACU->PD ......................................................................................... 67

D.1.8 SCS_18 PD->ACU ......................................................................................... 67

D.2 Commands ........................................................................................................... 67

D.2.1 Encryption key set (osdp_KEYSET) ............................................................... 67

D.2.2 Challenge and secure session initialization request (osdp_CHLNG) .............. 68

D.2.3 Server's random number and server cryptogram (osdp_SCRYPT) ................. 68

D.3 Replies ................................................................................................................. 68

D.3.1 Client's ID and client's random number (osdp_CCRYPT) ............................... 68

D.3.2 Client cryptogram packet and the initial R-MAC (osdp_RMAC_I) ................... 69

D.4 Algorithms and support functions .......................................................................... 69

D.4.1 Session key derivation ................................................................................... 69

D.4.2 Key diversification ......................................................................................... 69

D.4.3 Client cryptogram .......................................................................................... 70

D.4.4 Server cryptogram ......................................................................................... 70

D.4.5 Padding ......................................................................................................... 70

D.5 Message authentication code (MAC) generation ................................................... 70

D.5.1 General ......................................................................................................... 70

D.5.2 The wrap operation for security block types SCS_15, SCS-16, SCS_17,

and SCS_18 .................................................................................................. 71

---------------------- Page: 6 ----------------------
IEC 60839-11-5:2020 © IEC 2020 – 5 –

D.5.3 The unwrap operation .................................................................................... 72

D.6 Error recovery ....................................................................................................... 72

D.7 Field deployment and configuration ....................................................................... 72

Annex E (normative) Test vectors ........................................................................................ 74

Annex F (informative) Mapping of mandatory functions in IEC 60839-11-1 ........................... 75

Bibliography .......................................................................................................................... 85

Figure 1 – Schematic overview of an OSDP connection ........................................................ 12

Figure D.1 – MAC algorithm .................................................................................................. 71

Table 1 – Packet format ........................................................................................................ 15

Table 2 – Message control information .................................................................................. 16

Table 3 – The security block (SB) ......................................................................................... 17

Table 4 – Multi-part message structure ................................................................................. 17

Table 5 – Behaviour modes .................................................................................................. 18

Table 6 – Poll request ........................................................................................................... 19

Table 7 – ID report request ................................................................................................... 20

Table 8 – Peripheral device capabilities request ................................................................... 20

Table 9 – Local status report request .................................................................................... 20

Table 10 – Input status report request................................................................................... 20

Table 11 – Output status report request ................................................................................ 21

Table 12 – Reader status report request ............................................................................... 21

Table 13 – Output control command ..................................................................................... 22

Table 14 – Control code values ............................................................................................. 22

Table 15 – Reader LED control command ............................................................................. 23

Table 16 – Temporary control code values ............................................................................ 24

Table 17 – Permanent control code values ........................................................................... 24

Table 18 – Color values ........................................................................................................ 24

Table 19 – Reader buzzer control command (osdp_BUZ) ...................................................... 25

Table 20 – Reader text output command (osdp_TEXT) ......................................................... 26

Table 21 – Text command values .......................................................................................... 26

Table 22 – Communication configuration command (osdp_COMSET) ................................... 27

Table 23 – Scan and send biometric data (osdp_BIOREAD) ................................................. 27

Table 24 – Biometric types.................................................................................................... 28

Table 25 – Fingerprint formats .............................................................................................. 28

Table 26 – Command structure: 6-byte header followed by a variable length template .......... 29

Table 27 – Manufacturer specific commands (osdp_MFG) .................................................... 30

Table 28 – ACU receive size (osdp_ACURXSIZE) ................................................................ 30

Table 29 – Keep reader active (osdp_KEEPACTIVE) ............................................................ 30

Table 30 – Abort current operation (osdp_ABORT) ............................................................... 31

Table 31 – Get PIV data (osdp_PIVDATA) ............................................................................ 31

Table 32 – General authenticate (osdp_GENAUTH) fragment ............................................... 32

Table 33 – Authentication challenge (osdp_CRAUTH) fragment ............................................ 32

---------------------- Page: 7 ----------------------
– 6 – IEC 60839-11-5:2020 © IEC 2020

Table 34 – File transfer command ......................................................................................... 33

Table 35 – Extended write command structure ...................................................................... 34

Table 36 – Mode set command ............................................................................................. 34

Table 37 – Mode 0 configuration ........................................................................................... 34

Table 38 – Mode 1 configuration ........................................................................................... 34

Table 39 – Read setting request ........................................................................................... 35

Table 40 – Mode specific command codes ............................................................................ 35

Table 41 – Transparent content send request ....................................................................... 35

Table 42 – Smartcard connection done ................................................................................. 36

Table 43 – Request secure PIN entry command .................................................................... 36

Table 44 – Smartcard scan ................................................................................................... 37

Table 45 – General acknowledge (osdp_ACK) ...................................................................... 38

Table 46 – Negative acknowledge (osdp_NAK) ..................................................................... 38

Table 47 – Error codes ......................................................................................................... 39

Table 48 – Device identification report (osdp_PDID) ............................................................. 40

Table 49 – Device capabilities report (osdp_PDCAP) ............................................................ 40

Table 50 – Local status report (osdp_LSTATR) ..................................................................... 41

Table 51 – Input status report (osdp_ISTATR) ...................................................................... 41

Table 52 – Output status report (osdp_OSTATR) .................................................................. 42

Table 53 – Reader tamper status report (osdp_RSTATR) ..................................................... 42

Table 54 – Card data report, raw bit array (osdp_RAW) ........................................................ 43

Table 55 – Card data report, character array (osdp_FMT) ..................................................... 43

Table 56 – Keypad data report (osdp_KEYPAD) ................................................................... 44

Table 57 – Communication configuration report (osdp_COM) ................................................ 44

Table 58 – Scan and send biometric data (osdp_BIOREADR) ............................................... 45

Table 59 – Scan and match biometric template (osdp_BIOMATCHR) .................................... 45

Table 60 – Manufacturer specific reply (osdp_MFGREP) ...................................................... 46

Table 61 – PD busy reply (osdp_BUSY) ................................................................................ 46

Table 62 – PIV data reply (osdp_PIVDATAR) ........................................................................ 47

Table 63 – General authenticate response (osdp_GENAUTHR) ............................................ 47

Table 64 – Response to challenge (osdp_CRAUTHR) ........................................................... 48

Table 65 – Manufacturer specific status reply (osdp_MFGSTATR) ........................................ 48

Table 66 – Manufacturer specific error reply (osdp_MFGERRR) ........................................... 48

Table 67 – File transfer status (osdp_FTSTAT) ..................................................................... 49

Table 68 – Extended read reply ............................................................................................ 50

Table 69 – Mode specific reply codes ................................................................................... 50

Table 70 – Error reply ........................................................................................................... 50

Table 71 – Mode setting report ............................................................................................. 51

Table 72 – Card information report ....................................................................................... 51

Table 73 – Mode specific reply codes ................................................................................... 51

Table 74 – Error reply ........................................................................................................... 52

...

SLOVENSKI STANDARD
SIST IEC/TR2 62056-51:2001
01-februar-2001

Electricity metering - Data exchange for meter reading, tariff and load control - Part

51: Application layer protocols

Electricity metering - Data exchange for meter reading, tariff and load control - Part 51:

Application layer protocols

Comptage d'électricité - Echange de données pour la lecture des compteurs, le contrôle

des tarifs et de la charge - Partie 51: Protocoles de couche application
Ta slovenski standard je istoveten z: IEC/TS 62056-51
ICS:
17.220.20 0HUMHQMHHOHNWULþQLKLQ Measurement of electrical
PDJQHWQLKYHOLþLQ and magnetic quantities
35.100.70 Uporabniški sloj Application layer
91.140.50 Sistemi za oskrbo z elektriko Electricity supply systems
SIST IEC/TR2 62056-51:2001 en

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
SIST IEC/TR2 62056-51:2001
---------------------- Page: 2 ----------------------
SIST IEC/TR2 62056-51:2001
---------------------- Page: 3 ----------------------
SIST IEC/TR2 62056-51:2001
---------------------- Page: 4 ----------------------
SIST IEC/TR2 62056-51:2001
---------------------- Page: 5 ----------------------
SIST IEC/TR2 62056-51:2001
---------------------- Page: 6 ----------------------
SIST IEC/TR2 62056-51:2001
---------------------- Page: 7 ----------------------
SIST IEC/TR2 62056-51:2001
---------------------- Page: 8 ----------------------
SIST IEC/TR2 62056-51:2001
---------------------- Page: 9 ----------------------
SIST IEC/TR2 62056-51:2001
---------------------- Page: 10 ----------------------
SIST IEC/TR2 62056-51:2001
---------------------- Page: 11 ----------------------
SIST IEC/TR2 62056-51:2001
---------------------- Page: 12 ----------------------
SIST IEC/TR2 62056-51:2001
---------------------- Page: 13 ----------------------
SIST IEC/TR2 62056-51:2001
---------------------- Page: 14 -
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.