Water meters for cold potable water and hot water - Part 2: Test methods

ISO 4064-2:2014|OIML R 49-2:2013 is applicable to the type evaluation and initial verification testing of water meters for cold potable water and hot water as defined in ISO 4064‑1:2014|OIML R 49‑1:2013. OIML Certificates of Conformity can be issued for water meters under the scope of the OIML Certificate System, provided that ISO 4064-2:2014|OIML R 49-2:2013, ISO 4064‑1:2014|OIML R 49‑1:2013 and ISO 4064‑3:2014|OIML R 49‑3:2013 are used in accordance with the rules of the system. ISO 4064-2:2014|OIML R 49-2:2013 sets out details of the test programme, principles, equipment and procedures to be used for the type evaluation, and initial verification of a meter type. The provisions of ISO 4064-2:2014|OIML R 49-2:2013 also apply to ancillary devices, if required by national regulations. The provisions include requirements for testing the complete water meter and for testing the measurement transducer (including the flow or volume sensor) and the calculator (including the indicating device) of a water meter as separate units.

Compteurs d'eau potable froide et d'eau chaude — Partie 2: Méthodes d'essai

L'ISO 4064-2:2014|OIML R 49-2:2013 est applicable aux essais d'évaluation de type et de vérification primitive des compteurs d'eau potable froide et d'eau chaude tels que définis dans l'ISO 4064‑1:2014|OIML R 49-1. Des certificats de conformité OIML peuvent être délivrés pour les compteurs d'eau couverts par le domaine d'application du système de certificats OIML, à condition que l'ISO 4064‑1:2014|OIML R 49‑1, l'ISO 4064-2:2014|OIML R 49-2:2013, et l'ISO 4064‑3:2014|OIML R 49‑3 soient utilisées conformément aux règles du système. L'ISO 4064-2:2014|OIML R 49-2:2013 donne des détails sur le programme d'essai, les principes, l'équipement et les modes opératoires à utiliser pour les essais d'évaluation de type et de vérification primitive d'un type de compteur. Les dispositions de l'ISO 4064-2:2014|OIML R 49-2:2013 s'appliquent également aux dispositifs auxiliaires, si les réglementations nationales l'exigent. Les dispositions incluent les exigences d'essai du compteur d'eau complet et des exigences d'essai du transducteur de mesure (incluant le capteur de débit ou de volume) et du calculateur (incluant le dispositif indicateur) d'un compteur d'eau en tant qu'unités séparées.

General Information

Status
Published
Publication Date
25-May-2014
Current Stage
9599 - Withdrawal of International Standard
Start Date
19-Dec-2024
Completion Date
13-Dec-2025
Ref Project

Relations

Overview

ISO 4064-2:2014 (identical with OIML R 49-2:2013) specifies the test methods for water meters intended for cold potable water and hot water. It defines the test programme, principles, equipment and procedures for type evaluation and initial verification of water meter types. The standard also covers testing of separable parts (measurement transducers, flow/volume sensors, calculators and indicating devices) and ancillary devices where required by national regulation. When used together with ISO 4064‑1 and ISO 4064‑3, ISO 4064-2 supports issuance of OIML Certificates of Conformity under the OIML Certificate System.

Key topics and technical requirements

ISO 4064-2:2014 details a comprehensive test framework, including:

  • External examination and preparation procedures for specimens.
  • Performance tests applicable to all water meters: static pressure, intrinsic error (of indication), water temperature and overload temperature checks, reverse flow, pressure loss and flow disturbance tests.
  • Durability and environmental tests (temperature, humidity, vibration, mechanical shock).
  • Electromagnetic compatibility (EMC) and electrical tests: electrostatic discharge, radiated/conducted fields, surges, mains voltage dips and power-supply variation.
  • Special tests for electronic meters and separable parts: checking facilities, signal-line bursts, magnetic field immunity and absence-of-flow tests.
  • Test programme structure for type evaluation and initial verification, including sample numbers, reporting and presentation of results.
  • Normative and informative annexes covering type examination of checking facilities, calculation of relative error, installation requirements for flow disturbance tests, flow disturbers, and guidance on measurement uncertainty and pressure-tapping details.

Practical applications and users

ISO 4064-2 is essential for stakeholders involved in water meter design, testing and conformity assessment:

  • Manufacturers of mechanical and electronic water meters (product development and pre-certification testing).
  • Testing and calibration laboratories and notified bodies performing type evaluation and initial verification.
  • Utilities and water authorities specifying acceptance test protocols for meter procurement.
  • Regulatory and metrology authorities assessing compliance and issuing OIML certificates.
  • OEMs of ancillary devices and integrators testing separable transducers or calculators.

Using ISO 4064-2 ensures consistent, repeatable test procedures, reduces conformity risk and supports market access when combined with ISO 4064‑1 (metrological requirements) and ISO 4064‑3 (test report format).

Related standards (for reference)

  • ISO 4064-1:2014 - Metrological and technical requirements
  • ISO 4064-3:2014 - Test report format
  • IEC/ISO documents referenced for environmental and EMC testing (listed in the standard’s normative references)

Keywords: ISO 4064-2:2014, water meters test methods, water meter type evaluation, initial verification, OIML R 49-2, performance tests, EMC, durability testing, flow disturbance.

Standard
ISO 4064-2:2014 - Water meters for cold potable water and hot water
English language
101 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
ISO 4064-2:2014 - Compteurs d'eau potable froide et d'eau chaude
French language
104 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


INTERNATIONAL ISO
STANDARD 4064-2
Fourth edition
2014-06-01
Water meters for cold potable water
and hot water —
Part 2:
Test methods
Compteurs d’eau potable froide et chaude —
Partie 2: Méthodes d’essai
Reference number
©
ISO 2014
© ISO 2014
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized otherwise in any form
or by any means, electronic or mechanical, including photocopying, or posting on the internet or an intranet, without prior
written permission. Permission can be requested from either ISO at the address below or ISO’s member body in the country of
the requester.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Published in Switzerland
ii © ISO 2014 – All rights reserved

Contents Page
Foreword .v
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 2
4 Reference conditions . 2
5 Symbols, units and equations . 3
6 External examination . 3
6.1 General . 3
6.2 Object of the examination . 3
6.3 Preparation . 3
6.4 Examination procedures . 4
7 Performance tests for all water meters . 8
7.1 General . 8
7.2 Required conditions for all tests . 8
7.3 Static pressure test (ISO 4064-1:2014|OIML R 49-1:2013, 4.2.10) . 9
7.4 Determination of intrinsic errors (of indication) (ISO 4064-1:2014|OIML R 49-1:2013,
7.2.3) .10
7.5 Water temperature test (ISO 4064-1:2014|OIML R 49-1:2013, 4.2.8) .18
7.6 Overload water temperature test (ISO 4064-1:2014|OIML R 49-1:2013, 7.2.5) .18
7.7 Water pressure test (ISO 4064-1:2014|OIML R 49-1:2013, 4.2.8) .19
7.8 Reverse flow test (ISO 4064-1:2014|OIML R 49-1:2013, 4.2.7) .19
7.9 Pressure loss test (ISO 4064-1:2014|OIML R 49-1:2013, 6.5) .21
7.10 Flow disturbance tests (ISO 4064-1:2014|OIML R 49-1:2013, 6.3.4) .25
7.11 Durability tests (ISO 4064-1:2014|OIML R 49-1:2013, 7.2.6) .26
7.12 Magnetic field testing .31
7.13 Tests on ancillary devices of a water meter .31
7.14 Environmental testing .32
8 Performance tests related to influence factors and disturbances .32
8.1 General requirements (ISO 4064-1:2014|OIML R 49-1:2013, A.1) .32
8.2 Dry heat (non-condensing) (ISO 4064-1:2014|OIML R 49-1:2013, A.5) .36
8.3 Cold (ISO 4064-1:2014|OIML R 49-1:2013, A.5).37
8.4 Damp heat, cyclic (condensing) (ISO 4064-1:2014|OIML R 49-1:2013, A.5) .38
8.5 Power supply variation (ISO 4064-1:2014|OIML R 49-1:2013, A.5) .39
8.6 Vibration (random) (ISO 4064-1:2014|OIML R 49-1:2013, A.5) .42
8.7 Mechanical shock (ISO 4064-1:2014|OIML R 49-1:2013, A.5) .43
8.8 AC mains voltage dips, short interruptions and voltage variations (ISO 4064-
1:2014|OIML R 49-1:2013, A.5) .44
8.9 Bursts on signal lines (ISO 4064-1:2014|OIML R 49-1:2013, A.5) .45
8.10 Bursts (transients) on AC and DC mains (ISO 4064-1:2014|OIML R 49-1:2013, A.5) .47
8.11 Electrostatic discharge (ISO 4064-1:2014|OIML R 49-1:2013, A.5) .48
8.12 Radiated electromagnetic fields (ISO 4064-1:2014|OIML R 49-1:2013, A.5) .49
8.13 Conducted electromagnetic fields (ISO 4064-1:2014|OIML R 49-1:2013, A.5) .51
8.14 Surges on signal, data and control lines (ISO 4064-1:2014|OIML R 49-1:2013, A.5) .53
8.15 Surges on AC and DC mains power lines (ISO 4064-1:2014|OIML R 49-1:2013, A.5) . .54
8.16 Static magnetic field (ISO 4064-1:2014|OIML R 49-1:2013, 7.2.8) .55
8.17 Absence of flow test .56
9 Test program for type evaluation .57
9.1 Number of samples required .57
9.2 Performance test applicable to all water meters .57
9.3 Performance tests applicable to electronic water meters, mechanical water meters fitted
with electronic devices, and their separable parts .58
9.4 Type evaluation of separable parts of a water meter .58
9.5 Families of water meters .59
10 Tests for initial verification .59
10.1 Initial verification of complete and combined water meters .59
10.2 Initial verification of separable parts of a water meter .60
11 Presentation of results .61
11.1 Object of the reports .61
11.2 Identification and test data to be included in records .61
Annex A (normative) Type examination and testing of checking facilities of electronic devices .63
Annex B (normative) Calculating the relative error (of indication) of a water meter .69
Annex C (normative) Installation requirements for flow disturbance tests .75
Annex D (normative) Type evaluation of a family of water meters .77
Annex E (informative) Examples of methods and components used for testing concentric
water meters .79
Annex F (informative) Determining the density of water .82
Annex G (informative) Maximum uncertainties in the measurement of influence factors
and disturbances .84
Annex H (informative) Pressure loss test pressure tappings, hole and slot details .87
Annex I (normative) Flow disturbers .90
Bibliography .101
iv © ISO 2014 – All rights reserved

Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out
through ISO technical committees. Each member body interested in a subject for which a technical
committee has been established has the right to be represented on that committee. International
organizations, governmental and non-governmental, in liaison with ISO, also take part in the work.
ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of
electrotechnical standardization.
The procedures used to develop this document and those intended for its further maintenance are
described in the ISO/IEC Directives, Part 1. In particular the different approval criteria needed for the
different types of ISO documents should be noted. This document was drafted in accordance with the
editorial rules of the ISO/IEC Directives, Part 2, www.iso.org/directives.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of any
patent rights identified during the development of the document will be in the Introduction and/or on
the ISO list of patent declarations received, www.iso.org/patents.
Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement.
The committees responsible for this document are Technical Committee ISO/TC 30, Measurement of fluid
flow in closed conduits, Subcommittee SC 7, Volume methods including water meters and OIML Technical
Subcommittee TC 8/SC 5 Water meters.
This fourth edition of ISO 4064-2 cancels and replaces the third edition (ISO 4064-2:2005), which has
been technically revised. Provisions of the third edition are addressed in ISO 4064-5:2014.
ISO 4064 consists of the following parts, under the general title Water meters for cold potable water and
hot water:
— Part 1: Metrological and technical requirements
— Part 2: Test methods
— Part 3: Test report format
— Part 4: Non-metrological requirements not covered in ISO 4064-1
— Part 5: Installation requirements
This edition of ISO 4064-2 is identical with the corresponding edition of OIML R 49-2, which has been
issued concurrently. OIML R 49-2 was approved for final publication by the International Committee of
Legal Metrology at its 48th meeting in Ho Chi Minh City, Vietnam in October 2013 and will be submitted
to the International Conference on Legal Metrology in 2016 for formal sanction.
INTERNATIONAL STANDARD ISO 4064-2:2014(E)
Water meters for cold potable water and hot water —
Part 2:
Test methods
1 Scope
This part of ISO 4064|OIML R 49 is applicable to the type evaluation and initial verification testing of
water meters for cold potable water and hot water as defined in ISO 4064-1:2014|OIML R 49-1:2013.
OIML Certificates of Conformity can be issued for water meters under the scope of the OIML Certificate
System, provided that this part of ISO 4064|OIML R 49, ISO 4064-1:2014|OIML R 49-1:2013 and
ISO 4064-3:2014|OIML R 49-3:2013 are used in accordance with the rules of the System.
This part of ISO 4064|OIML R 49 sets out details of the test programme, principles, equipment and
procedures to be used for the type evaluation, and initial verification of a meter type.
The provisions of this part of ISO 4064|OIML R 49 also apply to ancillary devices, if required by national
regulations.
The provisions include requirements for testing the complete water meter and for testing the
measurement transducer (including the flow or volume sensor) and the calculator (including the
indicating device) of a water meter as separate units.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.
ISO 4064-1:2014|OIML R 49-1:2013, Water meters for cold potable water and hot water — Part 1:
Metrological and technical requirements
ISO 4064-3:2014|OIML R 49-3:2013, Water meters for cold potable water and hot water — Part 3: Test
report format
ISO/IEC Guide 98-3:2008, Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in
measurement (GUM:1995)
IEC 60068-2-1, Environmental testing — Part 2-1: Tests — Test A: Cold
IEC 60068-2-2, Environmental testing — Part 2-2: Tests — Test B: Dry heat
IEC 60068-2-30, Environmental testing — Part 2-30: Tests — Test Db: Damp heat, cyclic (12 h + 12 h cycle)
IEC 60068-2-31, Environmental testing — Part 2-31: Tests — Test Ec: Rough handling shocks, primarily for
equipment-type specimens
IEC 60068-2-47, Environmental testing — Part 2-47: Tests — Mounting of specimens for vibration, impact
and similar dynamic tests
IEC 60068-2-64, Environmental testing — Part 2-64: Tests — Test Fh: Vibration, broadband random and
guidance
IEC 60068-3-4, Environmental testing — Part 3-4: Supporting documentation and guidance — Damp heat
tests
IEC 60654-2, Operating conditions for industrial process measurement and control equipment — Part 2:
Power
IEC 61000-2-1, Electromagnetic compatibility (EMC) — Part 2: Environment — Section 1: Description of
the environment — Electromagnetic environment for low-frequency conducted disturbances and signaling
in public power supply systems
IEC 61000-2-2, Electromagnetic compatibility (EMC) — Part 2-2: Environment — Compatibility levels for
low-frequency conducted disturbances and signaling in public low-voltage power supply systems
IEC 61000-4-1, Electromagnetic compatibility (EMC) — Part 4-1: Testing and measurement techniques —
Overview of IEC 61000-4 series
IEC 61000-4-2, Electromagnetic compatibility (EMC) — Part 4-2: Testing and measurement techniques —
Electrostatic discharge immunity test
IEC 61000-4-3, Electromagnetic compatibility (EMC) — Part 4-3: Testing and measurement techniques —
Radiated, radio frequency, electromagnetic field immunity test
IEC 61000-4-4, Electromagnetic compatibility (EMC) — Part 4-4: Testing and measurement techniques —
Electrical fast transient/burst immunity test
IEC 61000-4-5, Electromagnetic compatibility (EMC) — Part 4-5: Testing and measurement techniques —
Surge immunity test
IEC 61000-4-6, Electromagnetic compatibility (EMC) — Part 4-6: Testing and measurement techniques —
Immunity to conducted disturbances, induced by radio-frequency fields
IEC 61000-4-11, Electromagnetic compatibility (EMC) — Part 4-11: Testing and measurement techniques —
Voltage dips, short interruptions and voltage variations immunity tests
IEC 61000-6-1, Electromagnetic compatibility (EMC) — Part 6-1: Generic standards — Immunity for
residential, commercial and light-industrial environments
IEC 61000-6-2, Electromagnetic compatibility (EMC) — Part 6-2: Generic standards — Immunity for
industrial environments
OIML D 11:2004, General requirements for electronic measuring instruments
OIML G 13, Planning of metrology and testing laboratories
3 Terms and definitions
For the purposes of this document, the terms and definitions given in ISO 4064-1:2014|OIML R 49-
1:2013 apply.
4 Reference conditions
All applicable influence quantities, except for the influence quantity being tested, shall be held at the
following values during type evaluation tests on a water meter. However, for influence factors and
2 © ISO 2014 – All rights reserved

disturbances for electronic water meters, it is permissible to use the reference conditions defined in the
applicable IEC standard:
Flow rate: 0,7 × (Q + Q ) ± 0,03 × (Q + Q )
2 3 2 3
Water temperature: T30, T50 is 20 °C ± 5 °C
T70 to T180 is 20 °C ± 5 °C and 50 °C ± 5 °C
T30/70 to T30/180 is 50 °C ± 5 °C
Water pressure: Within rated operating conditions
(see ISO 4064-1:2014|OIML R 49-1:2013, 6.4)
Ambient temperature range: 15 °C to 25 °C
Ambient relative humidity range: 45 % to 75 %
Ambient atmospheric pressure range: 86 kPa to 106 kPa [0,86 bar to 1,06 bar]
Power supply voltage (mains AC): Nominal voltage, U ± 5 %
nom
Power supply frequency: Nominal frequency, f ± 2 %
nom
Power supply voltage (battery): A voltage V in the range U ≤ V ≤ U
bmin bmax
During each test, the temperature and relative humidity shall not vary by more than 5 °C or 10 %,
respectively, within the reference range. The reference conditions are permitted to deviate from the
defined tolerance values during the performance tests if evidence can be given to the body responsible
for type approval that the type of meter under consideration is not affected by the deviation of the
condition in question. The actual values of the deviating condition, however, shall be measured and
documented as part of the performance test documentation.
5 Symbols, units and equations
Equations, symbols and their units, concerning the calculation of the error (of indication) of a water
meter used in this part of ISO 4064|OIML R 49, are given in Annex B.
6 External examination
6.1 General
During the external examination, all relevant values, dimensions, and observations shall be recorded.
NOTE 1 For presentation of the results of type examinations, see Clause 11.
NOTE 2 The relevant subclauses of ISO 4064-1:2014|OIML R 49-1:2013 are shown in parentheses in the
following.
6.2 Object of the examination
To verify that a water meter meets the requirements of ISO 4064-1:2014|OIML R 49-1:2013 with respect
to the design of the indicating device, the marking of the meter and the application of protection devices.
6.3 Preparation
Linear measurements that have to be taken of a meter shall be made using traceable, calibrated
measuring devices.
The actual or apparent dimensions of the scales of the indicating device shall be taken without removing
the meter lens or disassembling the meter.
NOTE A travelling microscope (cathetometer) can be used to measure the width, spacing and height of the
scale divisions and the height of the numerals.
6.4 Examination procedures
6.4.1 General
The following aspects of a meter design shall be examined on at least one meter from the sample.
Either the same meter sample may be used for all the external examinations or different meters from
the samples submitted may be used for some of the examinations.
6.4.2 Marks and inscriptions (ISO 4064-1:2014|OIML R 49-1:2013, 6.6)
a) Verify that a place is provided for affixing the verification mark which is visible without dismantling
the water meter.
b) Verify that the water meter is clearly and indelibly marked with the information presented in
ISO 4064-1:2014|OIML R 49-1:2013, 6.6.2.
c) Complete the section reference ISO 4064-1:2014|OIML R 49-1:2013, 6.6.1 and 6.6.2 (r) in
ISO 4064-3:2014|OIML R 49-3:2013, 4.4.1.
6.4.3 Indicating device (ISO 4064-1:2014|OIML R 49-1:2013, 6.7)
6.4.3.1 Function (ISO 4064-1:2014|OIML R 49-1:2013, 6.7.1.1)
a) Verify that the indicating device provides an easily read, reliable and unambiguous visual indication
of the indicated volume.
b) Verify that the indicating device includes visual means for testing and calibration.
c) If the indicating device includes additional elements for testing and calibration by other methods,
e.g. for automatic testing and calibration, record the type(s) of device.
d) If the meter is a combination meter with two indicating devices, 6.4.3 applies to both indicating
devices.
e) Complete the section reference ISO 4064-1:2014|OIML R 49-1:2013, 6.7.1.1 in
ISO 4064-3:2014|OIML R 49-3:2013, 4.4.1.
6.4.3.2 Unit of measurement, symbol, and its placement (ISO 4064-1:2014|OIML R 49-1:2013,
6.7.1.2)
a) Verify that the indicated volume of water is expressed in cubic metres.
b) Verify that the symbol m appears on the dial or immediately adjacent to the numbered display.
c) Complete the section reference ISO 4064-1:2014|OIML R 49-1:2013, 6.7.1.2 in
ISO 4064-3:2014|OIML R 49-3:2013, 4.4.1.
6.4.3.3 Indicating range (ISO 4064-1:2014|OIML R 49-1:2013, 6.7.1.3)
a) Verify that the indicating device is able to record the indicated volume in cubic metres given in
ISO 4064-1:2014|OIML R 49-1:2013, Table 5 corresponding to the permanent flow rate Q without
passing through zero.
4 © ISO 2014 – All rights reserved

b) Complete the section reference ISO 4064-1:2014|OIML R 49-1:2013, 6.7.1.3, in
ISO 4064-3:2014|OIML R 49-3:2013, 4.4.1.
6.4.3.4 Colour coding for indicating devices (ISO 4064-1:2014|OIML R 49-1:2013, 6.7.1.4)
a) Verify that either:
1) the colour black is used to indicate the cubic metre and its multiples; and
2) the colour red is used to indicate sub-multiples of a cubic metre; and
3) the colours are applied either to the pointers, indexes, numbers, wheels discs, dials or aperture
frames;
or other means of indicating the cubic metre are used in which there is no ambiguity in
distinguishing between the primary indication and alternative displays, e.g. sub-multiples for
verification and testing.
b) Complete the section reference ISO 4064-1:2014|OIML R 49-1:2013, 6.7.1.4, in
ISO 4064-3:2014|OIML R 49-3:2013, 4.4.1.
6.4.3.5 Types of indicating device (ISO 4064-1:2014|OIML R 49-1:2013, 6.7.2)
6.4.3.5.1 Type 1 — Analogue device (ISO 4064-1:2014|OIML R 49-1:2013, 6.7.2.1)
a) If a type 1 indicating device has been used, verify that volume is indicated by:
— either continuous movement of one or more pointers moving relative to graduated scales;
— or continuous movement of one or more circular scales or drums, each passing an index.
n
b) Verify that the value expressed in cubic metres for each scale division is of the form 10 , where n is a
positive or a negative whole number or zero, thereby establishing a system of consecutive decades.
c) Verify that each scale is either graduated in values expressed in cubic metres or accompanied by a
multiplication factor (×0,001; ×0,01; ×1; ×10; ×100; ×1 000, etc.).
d) Verify that the rotational movements of the pointers or circular scales are clockwise.
e) Verify that the linear movement of the pointers or scales is from left to right.
f) Verify that the movement of the numbered roller indicators is upwards.
g) Complete the section reference ISO 4064-1:2014|OIML R 49-1:2013, 6.7.2.1, in
ISO 4064-3:2014|OIML R 49-3:2013, 4.4.1.
6.4.3.5.2 Type 2 — Digital device (ISO 4064-1:2014|OIML R 49-1:2013, 6.7.2.2)
a) Verify that the indicated volume is given by a line of digits, appearing in one or more apertures.
b) Verify that the advance of one digit is completed while the digit of the next immediately lower decade
changes from 9 to 0.
c) Verify that the actual or apparent height of the digits is at least 4 mm.
d) For non-electronic devices:
1) verify that the movement of the numbered roller indicators (drums) is upwards;
2) if the lowest value decade has a continuous movement, verify that the aperture is large enough
to permit a digit to be read without ambiguity.
For electronic devices:
3) verify that for non-permanent displays the volume can be displayed at any time for at least 10 s;
4) check the entire display visually in the following sequence:
i) for seven segment type verify that all the elements can be correctly displayed (e.g. an
“eights” test),
ii) for seven segment type verify that all the elements can be blanked (a “blanks” test),
iii) for graphical displays use an equivalent test to verify that display faults cannot result in
any digit being misinterpreted,
iv) verify that each step of the sequence lasts at least 1 s.
e) Complete the section reference ISO 4064-1:2014|OIML R 49-1:2013, 6.7.2.2 in
ISO 4064-3:2014|OIML R 49-3:2013, 4.4.1.
6.4.3.5.3 Type 3 — Combination of analogue and digital devices (ISO 4064-
1:2014|OIML R 49-1:2013, 6.7.2.3)
a) If the indicating device is a combination of type 1 and 2 devices, verify that the respective
requirements of each apply (see 6.4.3.5.1 and 6.4.3.5.2).
b) Complete the section reference ISO 4064-1:2014|OIML R 49-1:2013, 6.7.2.3 in
ISO 4064-3:2014|OIML R 49-3:2013, 4.4.1.
6.4.3.6 Verification devices — First element of an indicating device — Verification interval
(ISO 4064-1:2014|OIML R 49-1:2013, 6.7.3)
6.4.3.6.1 General requirements (ISO 4064-1:2014|OIML R 49-1:2013, 6.7.3.1)
a) Verify that the indicating device has the means for visual, non-ambiguous verification testing and
calibration.
b) Note whether the visual verification display has a continuous or a discontinuous movement.
c) Note whether, in addition to the visual verification display, the indicating device includes provisions
for rapid testing by the inclusion of complementary elements (e.g. star wheels or discs), providing
signals through externally attached sensors. Note the relationship, stated by the manufacturer,
between the visual indication of volume and the signals emitted by these complementary devices.
d) Complete the section reference ISO 4064-1:2014|OIML R 49-1:2013, 6.7.3.1 in
ISO 4064-3:2014|OIML R 49-3:2013, 4.4.1.
6.4.3.6.2 Visual verification display (ISO 4064-1:2014|OIML R 49-1:2013, 6.7.3.2)
6.4.3.6.2.1 Value of the verification scale interval (ISO 4064-1:2014|OIML R 49-1:2013,
6.7.3.2.1)
a) Verify that the value of the verification scale interval, expressed in cubic metres, is of the form 1 ×
n n n
10 , or 2 × 10 , or 5 × 10 , where n is a positive or negative whole number, or zero.
b) For analogue and digital indicating devices with continuous movement of the first element, verify
that the verification scale interval is formed from the division into 2, 5 or 10 equal parts of the
interval between two consecutive digits of the first element.
6 © ISO 2014 – All rights reserved

c) For analogue and digital indicating devices with continuous movement of the first element, verify
that numbering is not applied to the divisions between consecutive digits of the first element.
d) For digital indicating devices with discontinuous movement of the first element, the verification
scale interval is the interval between two consecutive digits or incremental movements of the first
element.
e) Complete the section reference ISO 4064-1:2014|OIML R 49-1:2013, 6.7.3.2.1 in
ISO 4064-3:2014|OIML R 49-3:2013, 4.4.1.
6.4.3.6.2.2 Form of the verification scale (ISO 4064-1:2014|OIML R 49-1:2013, 6.7.3.2.2)
a) If the indicating device has continuous movement of the first element, check that the apparent scale
spacing is not less than 1 mm and not more than 5 mm.
b) Verify that the scale consists of:
— either lines of equal thickness not exceeding one-quarter of the scale spacing and differing only
in length;
— or contrasting bands of a constant width equal to the scale spacing.
c) Verify that the apparent width of the pointer at its tip does not exceed one-quarter of the scale
spacing.
d) Verify that the apparent width of the pointer at its tip does not exceed 0,5 mm.
e) Complete the section reference ISO 4064-1:2014|OIML R 49-1:2013, 6.7.3.2.2, in
ISO 4064-3:2014|OIML R 49-3:2013, 4.4.1.
6.4.3.6.2.3 Resolution of the indicating device (ISO 4064-1:2014|OIML R 49-1:2013, 6.7.3.2.3)
a) Note the value of the verification scale interval, δV m3
b) Calculate the actual volume V in m passed during  h 30 min at the minimum flow rate Q , from
a 1
V = Q × 1,5
a 1
c) Calculate the resolution error εr of the indicating device, expressed as a percentage, from:
1) for continuous movement of the first element:
05,,δδVV+05
ε = ×100%
r
V
a
δV
= ×100%
V
a
2) For discontinuous movement of the first element:
δδVV+
ε = ×100%
r
V
a
2δV
= ×100%
V
a
d) Verify that for accuracy class 1 meters, the value of the verification scale interval is small enough
to ensure that the resolution error ε of the indicating device does not exceed 0,25 % of the actual
r
volume required during 1 h 30 min at the minimum flow rate, Q .
ε ≤ 0,25 %
r
e) Verify that for accuracy class 2 meters, the verification scale interval is small enough to ensure that
the resolution error ε of the indicating device does not exceed 0,5 % of the actual volume required
r
during 1 h 30 min at the minimum flow rate, Q .
ε ≤ 0,5 %
r
f) Complete the section reference ISO 4064-1:2014|OIML R 49-1:2013, 6.7.3.2.3 in
ISO 4064-3:2014|OIML R 49-3:2013, 4.4.1.
When the display of the first element is continuous, an allowance shall be made for a maximum error in
each reading of not more than half of the verification scale interval.
When the display of the first element is discontinuous, an allowance shall be made for a maximum error
in each reading of not more than one digit of the verification scale.
6.4.4 Protection devices (ISO 4064-1:2014|OIML R 49-1:2013, 6.8)
a) Verify that the water meter includes protection devices as specified in
ISO 4064-1:2014|OIML R 49-1:2013, 6.8.
b) Complete the section reference ISO 4064-1:2014|OIML R 49-1:2013, 6.8.1 and 6.8.2.3 in
ISO 4064-3:2014|OIML R 49-3:2013, 4.4.1.
7 Performance tests for all water meters
7.1 General
During the performance tests, all relevant values, dimensions and observations shall be recorded.
NOTE 1 For presentation of the results of type evaluation tests see Clause 11.
NOTE 2 The relevant sub-clauses of ISO 4064-1:2014|OIML R 49-1:2013 are shown in parentheses in the
following.
7.2 Required conditions for all tests
7.2.1 Water quality
Water meter tests shall be carried out using water. The water shall be that of the public potable water
supply or shall meet the same requirements.
The water shall not contain any substance which might damage the meter or adversely affect its
operation. It shall not contain air bubbles.
If water is being recycled, measures shall be taken to prevent residual water in the meter from becoming
harmful to human beings.
7.2.2 General rules concerning test installation and location
7.2.2.1 Freedom from spurious influences
Test rigs shall be so designed, constructed, and used, that the performance of the rig itself shall not
contribute significantly to the test error. To this end, high standards of rig maintenance, plus adequate
supports and fittings, are necessary to prevent vibration of the meter, the test rig, and its accessories.
The test rig environment shall be such that the reference conditions of the test are met (see Clause 4).
8 © ISO 2014 – All rights reserved

During the tests, the gauge pressure at the outlet of each water meter shall be at least 0,03 MPa (0,3 bar)
and shall be sufficient to prevent cavitation.
It shall be possible to carry out test readings rapidly and easily.
7.2.2.2 Group testing of meters
Meters are tested either individually or in groups. In the latter case, the individual characteristics of
the meters shall be precisely determined. The presence of any meter in the test rig shall not contribute
significantly to the test error of any other meter.
7.2.2.3 Location
The environment chosen for meter tests shall be in accordance with the principles elaborated in
OIML G 13 and shall be free from disturbing influences (e.g. ambient temperature, vibration).
7.3 Static pressure test (ISO 4064-1:2014|OIML R 49-1:2013, 4.2.10)
7.3.1 Object of the test
To verify that the water meter can withstand the specified hydraulic test pressure for the specified time
without leakage or damage.
7.3.2 Preparation
a) Install the meters in the test rig either singly or in groups.
b) Bleed the test rig pipework and the water meters of air.
c) Ensure that the test rig is free from leaks.
d) Ensure that the supply pressure is free from pressure pulsations.
7.3.3 Test procedure
7.3.3.1 In-line meters
a) Increase the hydraulic pressure to 1,6 times the maximum admissible pressure (MAP) of the meter
and hold it for 15 min.
b) Examine the meters for physical damage, for external leaks and for leaks into the indicating device.
c) Increase the hydraulic pressure to twice the MAP and hold this pressure level for 1 min.
d) Examine the meters for physical damage, for external leaks and for leaks into the indicating device.
e) Complete the test report in ISO 4064-3:2014|OIML R 49-3:2013, 4.5.1.
Additional requirements:
1) Increase and decrease the pressure gradually without pressure surges.
2) Apply only the reference temperatures for this test.
3) The flow rate shall be zero during the test.
7.3.3.2 Concentric meters
The test procedure in 7.3.3.1 also applies to pressure testing of concentric water meters; however, the
seals located at the concentric meter/manifold interface (see example in Figure E.1) shall also be tested
to ensure that undisclosed internal leaks between the inlet and outlet passages of the meter do not
occur.
When the pressure test is carried out, the meter and manifold shall be tested together. Requirements
for testing concentric meters may vary according to the design; therefore an example of a test method
is shown in Figures E.2 and E.3.
7.3.4 Acceptance criteria
There shall be no leakage from the meter or leakage into the indicating device, or physical damage,
resulting from any of the pressure tests specified in 7.3.3.1 and 7.3.3.2.
7.4 Determination of intrinsic errors (of indication) (ISO 4064-
1:2014|OIML R 49-1:2013, 7.2.3)
7.4.1 Object of the test
To determine the intrinsic errors (of indication) of a water meter and the effects of the meter orientation
on the error (of indication).
7.4.2 Preparation
7.4.2.1 Description of the test rig
The method specified here for determining the meter errors (of indication) is the so-called “collection”
method, in which the quantity of water passed through a water meter is collected in one or more
collecting vessels and the quantity determined volumetrically or by weighing. Other methods may be
used, provided the requirements of 7.4.2.2.6.1 are met.
The checking of the errors (of indication) consists in comparing the volume indications given by the
meter under reference conditions against a calibrated reference device.
For the purpose of these tests, at least one meter should be tested without its temporary ancillary
devices attached (if any) unless the device is essential for the testing of the meter.
The test rig consists, typically, of:
a) a water supply (non-pressurized tank, pressurized tank, pump, etc.);
b) pipework;
c) a calibrated reference device (calibrated volumetric tank, weighing system, reference meter, etc.);
d) means for measuring the time of the test;
e) devices for automating the tests (if required);
f) means for measuring water temperature;
g) means for measuring water pressure;
h) means to determine density, if necessary;
i) means to determine conductivity, if necessary.
10 © ISO 2014 – All rights reserved

7.4.2.2 Pipework
7.4.2.2.1 Description
Pipework shall include:
a) a test section in which the meter(s) is (are) placed;
b) means for establishing the desired flow rate;
c) one or two isolating devices;
d) means for determining the flow rate;
and if necessary:
e) means for checking that the pipework is filled to a datum level before and after each test;
f) one or more air bleeds;
g) a non-return device;
h) an air separator;
i) a filter.
During the test, flow leakage, flow input and flow drainage shall not be permitted either between the
meter(s) and the reference device or from the reference device.
7.4.2.2.2 Test section
The test section shall include, in addition to the meter(s):
a) one or more pressure tappings for the measurement of pressure, of which one pressure tapping is
situated upstream of, and close to, the (first) meter;
b) means for measuring the temperature of the water close to the entry to the (first) meter.
The presence of any pipe components or devices placed in or near the measuring section shall not cause
cavitation or flow disturbances capable of altering the performance of the meters or causing errors (of
indication).
7.4.2.2.3 Precautions to be taken during tests
a) Check that the operation of the test rig is such that, during a test, the actual volume of water that
flows through the meter(s) is equal to that measured by the reference device.
b) Check that the pipe (e.g. the swan-neck in the outlet pipe) is filled to the same datum level at the
beginning and at the end of the test.
c) Bleed all air from the interconnecting pipework and the meter(s). The manufacturer may recommend
a procedure that ensures that all air is bled from the meter.
d) Take all precautions necessary to avoid the effects of vibration and shock.
7.4.2.2.4 Special arrangements for the installation of meters
7.4.2.2.4.1 Avoidance of erroneous measurements
The following reminder of the most frequent causes of erroneous measurements and the necessary
precautions for the installation of water meters on the test bench is prompted by the need to achieve a
test installation in which:
a) the hydrodynamic flow characteristics cause no discernible difference to the meter functioning
when compared with hydrodynamic flow characteristics which are undisturbed; and
b) the expanded uncertainty of the method employed does not exceed the stipulated value (see
7.4.2.2.6.1).
7.4.2.2.4.2 Need for straight lengths of pipe or a flow straightener
The accuracy of non-volumetric water meters can be affected by upstream disturbance caused, for
example, by the presence of bends, tees, valves or pumps.
In order to counteract these effects:
a) the meter shall be installed in accordance with the manufacturer’s instructions;
b) the connecting pipework shall have an internal diameter matched to the relevant meter connection;
and
c) if necessary, a flow straightener shall be installed upstream of the straight pipe length.
7.4.2.2.4.3 Common causes of flow disturbance
A flow can be subject to two types of disturbance: velocity-profile distortion and swirl, both of which
may affect the errors of indication of a water meter.
Velocity-profile distortion is typically caused by an obstruction partially blocking the pipe, e.g. the
presence of a partly closed valve or a misaligned flange joint. This can easily be eliminated by careful
application of installation procedures.
Swirl can be caused by two or more bends in different planes or by a single bend in combination with an
eccentric reducer or partially closed valve. This effect can be controlled either by ensuring an adequate
length of straight pipe upstream of the water meter, or by installing a flow straightening device, or by
a combination of the two. However, where possible, these types of pipework configurations should be
avoided.
7.4.2.2.4.4 Volumetric water meters
Some types of water meter, e.g. volumetric water meters (i.e. involving measuring chambers with
mobile walls), such as oscillating piston or nutating disc meters, are considered insensitive to upstream
installation conditions; hence no special conditions are required.
7.4.2.2.4.5 Meters employing electromagnetic induction
Meters employing electromagnetic induction as a measuring principle may be affected by the conductivity
of the test water.
The conductivity of the water used for testing this type of meter should be within the operational range
of conductivity specified by the meter manufacturer.
12 © ISO 2014 – All rights reserved

7.4.2.2.4.6 Other measuring principles
Other types of meter may require flow condition
...


NORME ISO
INTERNATIONALE 4064-2
Quatrième édition
2014-06-01
Compteurs d’eau potable froide et
d’eau chaude —
Partie 2:
Méthodes d’essai
Water meters for cold potable water and hot water —
Part 2: Test methods
Numéro de référence
©
ISO 2014
DOCUMENT PROTÉGÉ PAR COPYRIGHT
© ISO 2014
Droits de reproduction réservés. Sauf indication contraire, aucune partie de cette publication ne peut être reproduite ni utilisée
sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie, l’affichage sur
l’internet ou sur un Intranet, sans autorisation écrite préalable. Les demandes d’autorisation peuvent être adressées à l’ISO à
l’adresse ci-après ou au comité membre de l’ISO dans le pays du demandeur.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Publié en Suisse
ii © ISO 2014 – Tous droits réservés

Sommaire Page
Avant-propos .v
1 Domaine d’application . 1
2 Références normatives . 1
3 Termes et définitions . 2
4 Conditions de référence . 2
5 Symboles, unités et équations . 3
6 Examen externe . 3
6.1 Généralités . 3
6.2 Objectif de l’examen . 3
6.3 Préparation . 4
6.4 Modes opératoires d’examen . 4
7 Essais de performance applicables à tous les compteurs d’eau . 8
7.1 Généralités . 8
7.2 Conditions exigées pour tous les essais . 9
7.3 Essai de tenue à la pression statique (ISO 4064-1:2014|OIML R 49-1:2013, 4.2.10) . 9
7.4 Détermination des erreurs (d’indication) intrinsèques (ISO 4064-
1:2014|OIML R 49-1:2013, 7.2.3) .10
7.5 Essai de température de l’eau (ISO 4064-1:2014|OIML R 49-1:2013, 4.2.8) .18
7.6 Essai de dépassement de la température maximale de l’eau (ISO 4064-
1:2014|OIML R 49-1:2013, 7.2.5) .19
7.7 Essai de pression de l’eau (ISO 4064-1:2014|OIML R 49-1:2013, 4.2.8) .20
7.8 Essai de flux inversé (ISO 4064-1:2014|OIML R 49-1:2013, 4.2.7) .20
7.9 Essai de perte de pression (ISO 4064-1:2014|OIML R 49-1:2013, 6.5) .22
7.10 Essais de perturbation d’écoulement (ISO 4064-1:2014|OIML R 49-1:2013, 6.3.4) .26
7.11 Essais de durabilité (ISO 4064-1:2014|OIML R 49-1:2013, 7.2.6) .27
7.12 Essais de champ magnétique .33
7.13 Essais sur les dispositifs auxiliaires d’un compteur d’eau .33
7.14 Essais d’environnement .34
8 Essais de performance liés aux facteurs d’influence et aux perturbations.34
8.1 Exigences générales (ISO 4064-1:2014|OIML R 49-1:2013, A.1) .34
8.2 Chaleur sèche (sans condensation) (ISO 4064-1:2014|OIML R 49-1:2013, A.5) .37
8.3 Froid (ISO 4064-1:2014|OIML R 49-1:2013, A.5) .38
8.4 Chaleur humide, cyclique (avec condensation) (ISO 4064-1:2014|OIML R 49-1:2013, A.5) .
8.5 Variation de l’alimentation électrique (ISO 4064-1:2014|OIML R 49-1:2013, A.5) .40
8.6 Vibrations (aléatoires) (ISO 4064-1:2014|OIML R 49-1:2013, A.5) .44
8.7 Choc mécanique (ISO 4064-1:2014|OIML R 49-1:2013, A.5) .45
8.8 Creux de tension d’alimentation en courant alternatif, coupures brèves et variations de
tension (ISO 4064-1:2014|OIML R 49-1:2013, A.5) .46
8.9 Salves sur lignes de transmission de signaux (ISO 4064-1:2014|OIML R 49-1:2013, A.5) 48
8.10 Salves (transitoires) sur alimentation en courant alternatif et continu (ISO 4064-
1:2014|OIML R 49-1:2013, A.5) .49
8.11 Décharges électrostatiques (ISO 4064-1:2014|OIML R 49-1:2013, A.5) .50
8.12 Champs électromagnétiques rayonnés (ISO 4064-1:2014|OIML R 49-1:2013, A.5) .51
8.13 Champs électromagnétiques conduits (ISO 4064-1:2014|OIML R 49-1:2013, A.5) .53
8.14 Surtensions sur les lignes de transmission de signaux, de données et de contrôle
(ISO 4064-1:2014|OIML R 49-1:2013, A.5) .55
8.15 Surtensions sur les lignes d’alimentation en courant alternatif et continu (ISO 4064-
1:2014|OIML R 49-1:2013, A.5) .56
8.16 Champ magnétique statique (ISO 4064-1:2014|OIML R 49-1:2013, 7.2.8) .58
8.17 Essai d’absence de débit .59
9 Programme d’essais pour l’évaluation de type.59
9.1 Nombre d’échantillons requis .59
9.2 Essais de performance applicables à tous les compteurs d’eau .60
9.3 Essais de performance applicables aux compteurs d’eau électroniques, aux compteurs
d’eau mécaniques équipés de dispositifs électroniques et à leurs parties séparables .61
9.4 Évaluation de type des parties séparables d’un compteur d’eau .61
9.5 Familles de compteurs d’eau .62
10 Essais de vérification primitive .62
10.1 Vérification primitive des compteurs d’eau complets et des compteurs de combinaison .62
10.2 Vérification primitive des parties séparables d’un compteur d’eau .63
11 Présentation des résultats .64
11.1 Objectif des rapports .64
11.2 Données d’identification et d’essai à inclure dans les dossiers .64
Annexe A (normative) Examen de type et essais des systèmes de contrôle des
dispositifs électroniques .66
Annexe B (normative) Calcul de l’erreur (d’indication) relative d’un compteur d’eau .72
Annexe C (normative) Exigences d’installation pour les essais de perturbation d’écoulement .78
Annexe D (normative) Évaluation de type d’une famille de compteurs d’eau .80
Annexe E (informative) Exemples de méthodes et de composants utilisés pour soumettre à essai
les compteurs d’eau concentriques .82
Annexe F (informative) Détermination de la densité de l’eau .85
Annexe G (informative) Incertitudes de mesure maximales des facteurs d’influence et
des perturbations .87
Annexe H (informative) Détails des prises, orifices et fentes de pression pour l’essai de perte
de pression .90
Annexe I (normative) Perturbateurs d’écoulement .93
Bibliographie .104
iv © ISO 2014 – Tous droits réservés

Avant-propos
L’ISO (Organisation internationale de normalisation) est une fédération mondiale d’organismes
nationaux de normalisation (comités membres de l’ISO). L’élaboration des Normes internationales est
en général confiée aux comités techniques de l’ISO. Chaque comité membre intéressé par une étude
a le droit de faire partie du comité technique créé à cet effet. Les organisations internationales,
gouvernementales et non gouvernementales, en liaison avec l’ISO participent également aux travaux.
L’ISO collabore étroitement avec la Commission électrotechnique internationale (IEC) en ce qui concerne
la normalisation électrotechnique.
Les procédures utilisées pour élaborer le présent document et celles destinées à sa mise à jour sont
décrites dans les Directives ISO/IEC, Partie 1. Il convient, en particulier de prendre note des différents
critères d’approbation requis pour les différents types de documents ISO. Le présent document a été
rédigé conformément aux règles de rédaction données dans les Directives ISO/IEC, Partie 2, www.iso.
org/directives.
L’attention est appelée sur le fait que certains des éléments du présent document peuvent faire l’objet de
droits de propriété intellectuelle ou de droits analogues. L’ISO ne saurait être tenue pour responsable
de ne pas avoir identifié de tels droits de propriété et averti de leur existence. Les détails concernant les
références aux droits de propriété intellectuelle ou autres droits analogues identifiés lors de l’élaboration
du document sont indiqués dans l’Introduction et/ou sur la liste ISO des déclarations de brevets reçues,
www.iso.org/patents.
Les éventuelles appellations commerciales utilisées dans le présent document sont données pour
information à l’intention des utilisateurs et ne constituent pas une approbation ou une recommandation.
Le comité chargé de l’élaboration du présent document est l’ISO/TC 30, Mesure de débit des fluides dans
les conduites fermées, sous-comité SC 7, Méthodes volumétriques, y compris les compteurs d’eau et du sous-
comité de l’OIML TC 8/SC 5 Compteurs d’eau. Les dispositions de la troisième édition sont traitées dans
l’ISO 4064-5:2014.
Cette quatrième édition de l’ISO 4064-2 annule et remplace la troisième édition (ISO 4064-2:2005), qui
a fait l’objet d’une révision technique.
L’ISO 4064 comprend les parties suivantes, présentées sous le titre général Compteurs d’eau potable
froide et d’eau chaude:
— Partie 1: Exigences métrologiques et techniques
— Partie 2: Méthodes d’essai
— Partie 3: Format du rapport d’essais
— Partie 4: Exigences non métrologiques non couvertes par l’ISO 4064-1
— Partie 5: Exigences d’installation
Cette édition de l’ISO 4064-2 est identique à l’édition correspondante de l’OIML R 49-2, qui a été publiée
en même temps. L’OIML R 49-2 a été approuvée pour la publication finale par le Comité International de
Métrologie Légale à sa 48ème réunion à Ho Chi Minh City, Vietnam en Octobre 2013. Elle sera soumise à
la Conférence Internationale sur la Métrologie Légale en 2016 pour une sanction formelle.
NORME INTERNATIONALE ISO 4064-2:2014(F)
Compteurs d’eau potable froide et d’eau chaude —
Partie 2:
Méthodes d’essai
1 Domaine d’application
La présente partie de l’ISO 4064|OIML R 49 est applicable aux essais d’évaluation de type et de
vérification primitive des compteurs d’eau potable froide et d’eau chaude tels que définis dans
l’ISO 4064-1:2014|OIML R 49-1:2013. Des certificats de conformité OIML peuvent être délivrés
pour les compteurs d’eau couverts par le domaine d’application du système de certificats OIML,
à condition que la présente partie de ISO 4064|OIML R 49, ISO 4064-1:2014|OIML R 49-1:2013 et
ISO 4064-3:2014|OIML R 49-3:2013 soient utilisées conformément aux règles du système.
La présente partie de l’ISO 4064|OIML R 49 donne des détails sur le programme d’essai, les principes,
l’équipement et les modes opératoires à utiliser pour les essais d’évaluation de type et de vérification
primitive d’un type de compteur.
Les dispositions de la présente partie de l’ISO 4064|OIML R 49 s’appliquent également aux dispositifs
auxiliaires, si les réglementations nationales l’exigent.
Les dispositions incluent les exigences d’essai du compteur d’eau complet et des exigences d’essai
du transducteur de mesure (incluant le capteur de débit ou de volume) et du calculateur (incluant le
dispositif indicateur) d’un compteur d’eau en tant qu’unités séparées.
2 Références normatives
Les documents suivants, en tout ou partie, sont référencés de manière normative dans le présent
document et sont indispensables pour son application. Pour les références datées, seule l’édition citée
s’applique. Pour les références non datées, la dernière édition du document de référence s’applique (y
compris les éventuels amendements).
ISO 4064-1:2014|OIML R 49-1:2013, Compteurs d’eau potable froide et d’eau chaude — Partie 1: Exigences
métrologiques et techniques
ISO 4064-3:2014|OIML R 49-3:2013, Compteurs d’eau potable froide et d’eau chaude — Partie 3: Format
du rapport d’essai
Guide ISO/IEC 98-3:2008, Incertitude de mesure — Partie 3: Guide pour l’expression de l’incertitude de
mesure (GUM:1995)
IEC 60068-2-1, Essais d’environnement —Partie 2-1: Essai A: Froid
IEC 60068-2-2, Essais d’environnement — Partie 2-2: Essais - Essai B: Chaleur sèche
IEC 60068-2-30, Essais d’environnement — Partie 2-30: Essais - Essai Db: Essai cyclique de chaleur humide
(cycle de 12 h + 12 h)
IEC 60068-2-31, Essais d’environnement — Partie 2-31: Essais - Essai Ec: Choc lié à des manutentions
brutales, essai destiné en premier lieu aux matériels
IEC 60068-2-47, Essais d’environnement — Partie 2-47: Essais - Fixation de spécimens pour essais de
vibrations, d’impacts et autres essais dynamiques
IEC 60068-2-64, Essais d’environnement — Partie 2-64: Essais — Essai Fh Vibrations aléatoires à large
bande et guide
IEC 60068-3-4, Essais d’environnement — Partie 3-4: Documentation d’accompagnement et guide —Essais
de chaleur humide
IEC 60654-2, Conditions de fonctionnement pour les matériels de mesure et commande dans les processus
industriels. Partie 2: Alimentation
IEC 61000-2-1, Compatibilité électromagnétique (CEM) —Partie 2: Environnement. Section 1: Description
de l’environnement —Environnement électromagnétique pour les perturbations conduites basse fréquence
et la transmission de signaux sur les réseaux publics d’alimentation
IEC 61000-2-2, Compatibilité électromagnétique (CEM) —Partie 2: Environnement. Section 2: Niveaux
de compatibilité pour les perturbations conduites à basse fréquence et la transmission des signaux sur les
réseaux publics d’alimentation basse tension
IEC 61000-4-1, Compatibilité électromagnétique (CEM) —Partie 4-1: Techniques d’essai et de mesure —Vue
d’ensemble de la série IEC 61000-4
IEC 61000-4-2, Compatibilité électromagnétique (CEM) —Partie 4-2: Techniques d’essai et de mesure —
Essais d’immunité aux décharges électrostatiques
IEC 61000-4-3, Compatibilité électromagnétique (CEM) —Partie 4-3: Techniques d’essai et de mesure —
Essais d’immunité aux champs électromagnétiques rayonnés aux fréquences radioélectriques
IEC 61000-4-4, Compatibilité électromagnétique (CEM) — Partie 4-4: Techniques d’essai et de mesure —
Essais d’immunité aux transitoires électriques rapides en salves. Publication fondamentale en CEM
IEC 61000-4-5, Compatibilité électromagnétique (CEM) — Partie 4-5: Techniques d’essai et de mesure —
Essai d’immunité aux ondes de choc
IEC 61000-4-6, Compatibilité électromagnétique (CEM) — Partie 4-6: Techniques d’essai et de mesure —
Immunité aux perturbations conduites, induites par les champs radioélectriques
IEC 61000-4-11, Compatibilité électromagnétique (CEM) —Partie 4-11: Techniques d’essai et de mesure —
Essais d’immunité aux creux de tension, coupures brèves et variations de tension
IEC 61000-6-1, Compatibilité électromagnétique (CEM) — Partie 6-1: normes génériques - Immunité pour
les environnements résidentiels, commerciaux et de l’industrie légère
IEC 61000-6-2, Compatibilité électromagnétique (CEM) — Partie 6-2: normes génériques - Immunité pour
les environnements industriels
OIML D 11:2004, Exigences générales pour les instruments de mesure électroniques
OIML G 13, Planification de laboratoires de métrologie et d’essais
3 Termes et définitions
Pour les besoins du présent document, les termes et définitions donnés dans
l’ISO 4064-1:2014|OIML R 49-1:2013 s’appliquent.
4 Conditions de référence
Toutes les grandeurs d’influence applicables, excepté la grandeur d’influence soumise à essai, doivent
être maintenues aux valeurs suivantes pendant les essais d’évaluation de type sur un compteur
2 © ISO 2014 – Tous droits réservés

d’eau. Cependant, pour les facteurs d’influence et les perturbations concernant les compteurs d’eau
électroniques, il est possible d’utiliser les conditions de référence définies dans la norme IEC applicable:
Débit: 0,7 × (Q + Q ) ± 0,03 × (Q + Q )
2 3 2 3
Température de l’eau: T 30, T 50: température de 20 °C ± 5 °C
T70 à T180, température de 20 °C ± 5 °C et 50 °C ± 5 °C
T30/70 à T30/180 température de 50 °C ± 5 °C
Pression de l’eau: Conforme aux conditions assignées de fonctionnement
(Voir l’ISO 4064-1:2014|OIML R 49-1:2013, 6.4)
Plage de température ambiante: 15 °C à 25 °C
Plage d’humidité relative ambiante: 45 % à 75 %
Plage de pression atmosphérique ambiante: 86 kPa à 106 kPa [0,86 bar à 1,06 bar]
Tension d’alimentation (courant alternatif): Tension nominale (U ) ± 5 %
nom
Fréquence d’alimentation: Fréquence nominale ( f ) ± 2 %
nom
Tension d’alimentation (batterie): Une tension V dans la plage U ≤ V ≤ U
bmin bmax
Pendant chaque essai, la température et l’humidité relative ne doivent pas varier de plus de 5 °C ou
10 %, respectivement, par rapport à la plage de référence. Les conditions de référence peuvent s’écarter
des valeurs de tolérance définies pendant les essais de performance si l’on peut prouver à l’organisme
responsable de l’approbation de type que le type de compteur considéré n’est pas affecté par le
changement de condition en question. Cependant, les valeurs réelles de la condition déviante doivent
être mesurées et consignées dans la documentation relative aux essais de performance.
5 Symboles, unités et équations
Les équations, symboles et unités concernant le calcul de l’erreur (d’indication) d’un compteur d’eau
utilisé dans la présente partie de l’ISO 4064|OIML R 49, sont donnés dans l’Annexe B.
6 Examen externe
6.1 Généralités
Pendant l’examen externe, toutes les valeurs, dimensions et observations pertinentes doivent être
consignées.
NOTE 1 Pour une présentation des résultats des examens de type, voir l’Article 11.
NOTE 2 Les paragraphes appropriés de l’ISO 4064-1:2014|OIML R 49-1:2013 sont indiqués ci-dessous entre
parenthèses.
6.2 Objectif de l’examen
Vérifier qu’un compteur d’eau satisfait aux exigences de l’ISO 4064-1:2014|OIML R 49-1:2013 concernant
la conception du dispositif indicateur, le marquage du compteur et l’application des dispositifs de
protection.
6.3 Préparation
Des mesurages linéaires devant être effectués d’un compteur doivent être réalisés en utilisant des
dispositifs de mesure étalonnés et traçables.
Les dimensions réelles ou apparentes des échelles du dispositif indicateur doivent être prises sans
enlever le verre du compteur et sans démonter le compteur.
NOTE Un microscope de voyage (cathétomètre) peut être utilisé pour mesurer la largeur, l’espacement et la
hauteur des divisions d’échelle ainsi que la hauteur des chiffres.
6.4 Modes opératoires d’examen
6.4.1 Généralités
Les aspects suivants de la conception d’un compteur doivent être examinés sur au moins un compteur
de l’échantillon.
Soit le même échantillon de compteur peut être utilisé pour tous les examens externes, soit différents
compteurs des échantillons soumis peuvent être utilisés pour certains examens.
6.4.2 Marquages et inscriptions (ISO 4064-1:2014|OIML R 49-1:2013, 6.6)
a) Vérifier qu’un emplacement est disponible pour apposer la marque de vérification qui est visible
sans démonter le compteur d’eau.
b) Vérifier que le compteur d’eau porte, de manière lisible et indélébile, les informations présentées
dans l’ISO 4064-1:2014|OIML R 49-1:2013, 6.6.2.
c) Compléter la référence de section ISO 4064-1:2014|OIML R 49-1:2013, 6.6.1 et 6.6.2 (r) dans
l’ISO 4064-3:2014|OIML R 49-3:2013, 4.4.1.
6.4.3 Dispositif indicateur (ISO 4064-1:2014|OIML R 49-1:2013, 6.7)
6.4.3.1 Fonction (ISO 4064-1:2014|OIML R 49-1:2013, 6.7.1.1)
a) Vérifier que le dispositif indicateur fournit une indication visuelle facilement lisible, fiable et non
ambiguë du volume indiqué.
b) Vérifier que le dispositif indicateur inclut des éléments visuels pour les essais et l’étalonnage.
c) Si le dispositif indicateur inclut des éléments supplémentaires pour les essais et l’étalonnage par
d’autres méthodes, par exemple pour les essais et l’étalonnage automatiques, enregistrer le ou les
types de dispositif.
d) Si le compteur est un compteur combiné équipé de deux dispositifs indicateurs, le paragraphe 6.4.3
s’applique aux deux dispositifs indicateurs.
e) Compléter la référence de section ISO 4064-1:2014|OIML R 49-1:2013, 6.7.1.1 dans
l’ISO 4064-3:2014|OIML R 49-3:2013, 4.4.1.
6.4.3.2 Unité de mesure, symbole et son emplacement (ISO 4064-1:2014|OIML R 49-1:2013,
6.7.1.2)
a) Vérifier que le volume d’eau indiqué est exprimé en mètres cubes.
b) Vérifier que le symbole m apparaît sur le cadran ou qu’il est immédiatement adjacent à l’afficheur
numérique.
4 © ISO 2014 – Tous droits réservés

c) Compléter la référence de section ISO 4064-1:2014|OIML R 49-1:2013, 6.7.1.2 dans
l’ISO 4064-3:2014|OIML R 49-3:2013, 4.4.1.
6.4.3.3 Étendue d’indication (ISO 4064-1:2014|OIML R 49-1:2013, 6.7.1.3)
a) Vérifier que le dispositif indicateur peut enregistrer le volume en mètres cubes indiqué dans
l’ISO 4064-1:2014|OIML R 49-1:2013, Tableau 5, correspondant au débit permanent q sans passer
par zéro.
b) Compléter la référence de section ISO 4064-1:2014|OIML R 49-1:2013, 6.7.1.3 dans
l’ISO 4064-3:2014|OIML R 49-3:2013, 4.4.1.
6.4.3.4 Couleur de codification pour les dispositifs indicateurs (ISO 4064-
1:2014|OIML R 49-1:2013, 6.7.1.4)
a) Vérifier soit:
1) que la couleur noire est utilisée pour indiquer le mètre cube et ses multiples; et
2) que la couleur rouge est utilisée pour indiquer des sous-multiples du mètre cube; et
3) que les couleurs sont appliquées soit aux aiguilles, repères, chiffres, volants, disques, cadrans
ou ouvertures;
soit que d’autres éléments indicateurs du mètre cube sont utilisés à condition qu’il n’y ait pas
d’ambiguïté dans la distinction entre l’indication primaire et les affichages alternatifs, par exemple
les sous-multiples pour la vérification et les essais.
b) Compléter la référence de section ISO 4064-:2014|OIML R 49-1:2013, 6.7.1.4 dans
l’ISO 4064-3:2014|OIML R 49-3:2013, 4.4.1.
6.4.3.5 Types de dispositif indicateur (ISO 4064-1:2014|OIML R 49-1:2013, 6.7.2)
6.4.3.5.1 Type 1 —Dispositif analogique (ISO 4064-1:2014|OIML R 49-1:2013, 6.7.2.1)
a) Si un dispositif indicateur de type 1 a été utilisé, vérifier que le volume est indiqué:
— soit par le mouvement continu d’une ou plusieurs aiguilles mobiles par rapport à des échelles
graduées;
— soit par le mouvement continu d’une ou plusieurs échelles circulaires ou tambours chacun défilant
devant un index.
n
b) Vérifier que la valeur exprimée en mètres cubes pour chaque division d’échelle est de la forme 10 ,
où n est un nombre entier positif ou négatif ou zéro, constituant de ce fait un système de décades
consécutives.
c) Vérifier que chaque échelle est soit graduée en valeurs exprimées en mètres cubes soit accompagnée
d’un facteur multiplicateur (×0,001; ×0,01; ×1; ×10; ×100; ×1 000, etc.).
d) Vérifier que le mouvement de rotation des aiguilles ou échelles circulaires s’effectue dans le sens
des aiguilles d’une montre.
e) Vérifier que le mouvement linéaire des aiguilles ou échelles s’effectue de gauche à droite.
f) Vérifier que le mouvement des indicateurs à cylindre gradué est dirigé vers le haut.
g) Compléter la référence de section ISO 4064-1:2014|OIML R 49-1:2013, 6.7.2.1 dans
l’ISO 4064-3:2014|OIML R 49-3:2013, 4.4.1.
6.4.3.5.2 Type 2 —Dispositif numérique (ISO 4064-1:2014|OIML R 49-1:2013, 6.7.2.2)
a) Vérifier que le volume indiqué est donné par une ligne de chiffres apparaissant dans une ou plusieurs
ouvertures.
b) Vérifier que le passage à un chiffre se fait en même temps que le chiffre de la décade adjacente
immédiatement inférieure passe de 9 à 0.
c) Vérifier que la hauteur réelle ou apparente des chiffres est d’au moins 4 mm.
d) Pour les dispositifs non électroniques:
1) vérifier que le mouvement des indicateurs à cylindre gradué (tambours) est dirigé vers le haut;
2) si la valeur de la décade la plus basse a un mouvement continu, vérifier que l’ouverture est
suffisamment grande pour permettre la lecture non ambiguë d’un chiffre.
Pour les dispositifs électroniques:
3) vérifier que, pour l’affichage temporaire, le volume peut être affiché à tout moment pendant au
moins 10 s;
4) contrôler visuellement l’ensemble du système d’affichage dans l’ordre suivant:
i) pour le type à sept segments, vérifier que tous les éléments peuvent être correctement
affichés (par exemple, un essai des «huit»;)
ii) pour le type à sept segments, vérifier que tous les éléments peuvent être supprimés (un
essai des «blancs»);
iii) pour l’affichage graphique, utiliser un essai équivalent pour vérifier que les défauts
d’affichage ne peuvent pas fausser l’interprétation des chiffres;
iv) vérifier que chaque étape de la séquence dure au moins 1 s.
e) Compléter la référence de section ISO 4064-1:2014|OIML R 49-1:2013, 6.7.2.2 dans
l’ISO 4064-3:2014|OIML R 49-3:2013, 4.4.1.
6.4.3.5.3 Type 3 —Combinaison de dispositifs analogiques et numériques (ISO 4064-
1:2014|OIML R 49-1:2013, 6.7.2.3)
a) Si le dispositif indicateur est une combinaison des dispositifs des types 1 et 2, vérifier que les
exigences respectives de chacun s’appliquent (voir en 6.4.3.5.1 et 6.4.3.5.2).
b) Compléter la référence de section ISO 4064-1:2014|OIML R 49-1:2013, 6.7.2.3 dans
l’ISO 4064-3:2014|OIML R 49-3:2013, 4.4.1.
6.4.3.6 Dispositifs de vérification — Premier élément d’un dispositif indicateur — Échelon de
vérification (ISO 4064-1:2014|OIML R 49-1:2013, 6.7.3)
6.4.3.6.1 Exigences générales (ISO 4064-1:2014|OIML R 49-1:2013, 6.7.3.1)
a) Vérifier que le dispositif indicateur dispose d’éléments visuels, non ambigus, pour les essais de
vérification et l’étalonnage.
b) Noter si le dispositif de vérification visuelle a un mouvement continu ou discontinu.
c) Noter si, en plus du dispositif de vérification visuelle, le dispositif indicateur inclut des dispositions
pour contrôle rapide par l’inclusion d’éléments complémentaires (par exemple, étoiles, roues ou
disques), fournissant des signaux par l’intermédiaire de détecteurs externes. Noter la relation,
indiquée par le fabricant, entre l’indication visuelle du volume et les signaux émis par ces dispositifs
complémentaires.
6 © ISO 2014 – Tous droits réservés

d) Compléter la référence de section ISO 4064-1:2014|OIML R 49-1:2013 6.7.3.1 dans
l’ISO 4064-3:2014|OIML R 49-3:2013, 4.4.1.
6.4.3.6.2 Dispositif de vérification visuelle (ISO 4064-1:2014|OIML R 49-1:2013, 6.7.3.2)
6.4.3.6.2.1 Valeur de l’échelon de vérification (ISO 4064-1:2014|OIML R 49-1:2013, 6.7.3.2.1)
n
a) Vérifier que la valeur de l’échelon de vérification, exprimée en mètres cubes, est de la forme: 1 × 10
n n
ou 2 × 10 ou 5 × 10 , où n est zéro ou un nombre entier positif ou négatif.
b) Pour les dispositifs indicateurs analogiques et numériques à mouvement continu du premier
élément, vérifier que l’échelon de vérification est formé par la division en 2, 5 ou 10 parties égales
de l’intervalle entre deux chiffres consécutifs du premier élément.
c) Pour les dispositifs indicateurs analogiques et numériques à mouvement continu du premier
élément, vérifier que le numérotage ne s’applique pas aux divisions entre les chiffres consécutifs du
premier élément.
d) Pour les dispositifs indicateurs numériques à mouvement discontinu du premier élément, l’échelon
de vérification est l’intervalle entre deux chiffres consécutifs ou deux variations incrémentielles du
premier élément.
e) Compléter la référence de section ISO 4064-1:2014|OIML R 49-1:2013, 6.7.3.2.1 dans
l’ISO 4064-3:2014|OIML R 49-3:2013, 4.4.1.
6.4.3.6.2.2 Forme de l’échelle de vérification (ISO 4064-1:2014|OIML R 49-1:2013, 6.7.3.2.2)
a) Si le dispositif indicateur a un mouvement continu du premier élément, vérifier que la longueur
apparente d’une division d’échelle n’est pas inférieure à 1 mm ou supérieure à 5 mm.
b) Vérifier que l’échelle consiste:
— soit en des lignes d’épaisseur égale ne dépassant pas un quart de la longueur d’une division d’échelle
et différant seulement par leur longueur;
— soit en des bandes contrastées de largeur constante égale à la longueur d’une division d’échelle.
c) Vérifier que la largeur apparente de la pointe de l’aiguille ne dépasse pas un quart de la longueur
d’une division d’échelle.
d) Vérifier que la largeur apparente de la pointe de l’aiguille ne dépasse pas 0,5 mm.
e) Compléter la référence de section ISO 4064-1:2014|OIML R 49-1:2013, 6.7.3.2.2 dans
l’ISO 4064-3:2014|OIML R 49-3:2013, 4.4.1.
6.4.3.6.2.3 Résolution du dispositif indicateur (ISO 4064-1:2014|OIML R 49-1:2013, 6.7.3.2.3)
a) Noter la valeur de l’échelon de vérification, δV m
b) Calculer le volume réel V en m écoulé pendant 1 h 30 min au débit minimal q , au moyen de la
a 1
formule:
V = Q × 1,5
a 1
c) Calculer l’erreur de résolution du dispositif indicateur ε en pourcentage, au moyen des formules:
r
1) pour un mouvement continu du premier élément:
05,,δδVV+05
ε = ×100%
r
V
a
δV
= ×100%
V
a
2) pour un mouvement discontinu du premier élément:
δδVV+
ε = ×100%
r
V
a
2δV
= ×100%
V
a
d) Vérifier que, pour les compteurs de classe d’exactitude 1, la valeur de l’échelon de vérification est
suffisamment faible pour garantir que l’erreur de résolution ε du dispositif indicateur ne dépasse
r
pas 0,25 % du volume réel requis pendant 1 h 30 min au débit minimal Q .
ε ≤ 0,25 %
r
e) Vérifier que, pour les compteurs de classe d’exactitude 2, l’échelon de vérification est suffisamment
faible pour garantir que l’erreur de résolution ε du dispositif indicateur ne dépasse pas 0,5 % du
r
volume réel requis pendant 1 h 30 min au débit minimal Q .
ε ≤ 0,5 %
r
f) Compléter la référence de section ISO 4064-1:2014|OIML R 49-1:2013, 6.7.3.2.3 dans
l’ISO 4064-3:2014|OIML R 49-3:2013, 4.4.1.
Lorsque l’affichage du premier élément est continu, une déduction doit être faite pour une erreur
maximale de chaque mesure ne dépassant pas la moitié de l’échelon de vérification.
Lorsque l’affichage du premier élément est discontinu, une déduction doit être faite pour une erreur
maximale de chaque mesure ne dépassant pas un chiffre de l’échelle de vérification.
6.4.4 Dispositifs de protection (ISO 4064-1:2014|OIML R 49-1:2013, 6.8)
a) Vérifier que le compteur d’eau inclut des dispositifs de protection tels que spécifiés dans
l’ISO 4064-1:2014|OIML R 49-1:2013, 6.8.
b) Compléter la référence de section ISO 4064-1:2014|OIML R 49-1:2013, 6.8.1 et 6.8.2.3 dans
l’ISO 4064-3:2014|OIML R 49-3:2013, 4.4.1.
7 Essais de performance applicables à tous les compteurs d’eau
7.1 Généralités
Pendant les essais de performance, toutes les valeurs, dimensions et observations pertinentes doivent
être consignées.
NOTE 1 Pour une présentation des résultats des essais d’évaluation de type, voir l’Article 11.
NOTE 2 Les paragraphes appropriés de l’ISO 4064-1:2014|OIML R 49-1:2013 sont indiqués ci-dessous entre
parenthèses.
8 © ISO 2014 – Tous droits réservés

7.2 Conditions exigées pour tous les essais
7.2.1 Qualité de l’eau
Les essais sur les compteurs d’eau doivent être effectués avec de l’eau. L’eau doit provenir d’une
alimentation en eau potable publique ou doit satisfaire à de telles exigences.
L’eau ne doit contenir aucune substance susceptible d’endommager le compteur ou de perturber son
fonctionnement. Elle doit être exempte de bulles d’air.
Si l’eau est recyclée, des mesures doivent être prises pour que l’eau résiduaire présente dans le compteur
ne devienne pas dangereuse pour l’homme.
7.2.2 Règles générales concernant l’installation et l’emplacement d’essai
7.2.2.1 Absence d’influences parasites
Les montages d’essai doivent être conçus, construits et utilisés de façon à ce que les performances du
montage lui-même ne contribuent pas significativement à l’erreur d’essai. Pour cela, des normes strictes
concernant la maintenance de montage ainsi que des supports et des raccords adéquats sont nécessaires
pour empêcher toute vibration du compteur, du montage d’essai et de ses accessoires.
L’environnement du montage d’essai doit être tel que les conditions de référence de l’essai sont satisfaites
(voir l’Article 4).
Pendant les essais, la pression manométrique à la sortie de chaque compteur d’eau doit être d’au moins
0,03 MPa (0,3 bar) et doit être suffisante pour empêcher la cavitation.
Il doit être possible de procéder aux lectures d’essai rapidement et facilement.
7.2.2.2 Essais groupés des compteurs
Les compteurs sont soumis à essai individuellement ou en groupes. Dans ce dernier cas, les caractéristiques
individuelles des compteurs doivent être déterminées avec précision. La présence d’un compteur quel
qu’il soit dans le montage d’essai ne doit pas influer de manière significative sur l’erreur d’essai d’un
autre compteur quel qu’il soit.
7.2.2.3 Emplacement
L’environnement choisi pour les essais sur les compteurs doit être conforme aux principes élaborés
dans la publication OIML G 13 et doit être protégé contre toute perturbation (par exemple, température
ambiante, vibrations).
7.3 Essai de tenue à la pression statique (ISO 4064-1:2014|OIML R 49-1:2013, 4.2.10)
7.3.1 Objectif de l’essai
Vérifier que le compteur d’eau peut supporter la pression d’essai hydraulique spécifiée pendant la durée
spécifiée, sans fuites ni dommages.
7.3.2 Préparation
a) Installer les compteurs dans le montage d’essai individuellement ou en groupes.
b) Évacuer l’air de la tuyauterie du montage d’essai et des compteurs d’eau.
c) S’assurer que le montage d’essai est étanche.
d) S’assurer que la pression d’alimentation n’oscille pas.
7.3.3 Mode opératoire d’essai
7.3.3.1 Compteurs en ligne
a) Augmenter la pression hydraulique à 1,6 fois la pression maximale admissible (PMA) du compteur
et la maintenir pendant 15 min.
b) Vérifier que les compteurs ne présentent pas de dommages physiques, de fuites externes et de fuites
dans le dispositif indicateur.
c) Augmenter la pression hydraulique à deux fois la PMA et maintenir ce niveau de pression pendant
1 min.
d) Vérifier que les compteurs ne présentent pas de dommages physiques, de fuites externes et de fuites
dans le dispositif indicateur.
e) Compléter le rapport d’essai dans l’ISO 4064-3:2014|OIML R 49-3:2013, 4.5.1.
Exigences supplémentaires:
1) augmenter et diminuer la pression graduellement, sans à-coups de pression;
2) appliquer uniquement les températures de référence pour cet essai;
3) le débit doit être nul pendant l’essai.
7.3.3.2 Compteurs concentriques
Le mode opératoire d’essai de 7.3.3.1 s’applique également aux essais de pression des compteurs d’eau
concentriques; toutefois, les joints situés à l’interface compteur concentrique/embase (voir l’exemple
dans la Figure E.1) doivent aussi être soumis à essai pour garantir qu’il n’y a pas de fuites internes non
révélées entre les orifices d’entrée et de sortie du compteur.
Le compteur et l’embase doivent être soumis à essai ensemble lors de l’essai de pression. Les exigences
d’essai des compteurs concentriques peuvent varier en fonction de la conception; par conséquent, un
exemple d’une méthode d’essai est présenté dans les Figures E.2 et E.3.
7.3.4 Critères d’acceptation
Il ne doit y avoir aucune fuite émanant du compteur ou s’introduisant dans le dispositif indicateur, ni
aucun dommage physique résultant des essais de pression spécifiés en 7.3.3.1 et 7.3.3.2.
7.4 Détermination des erreurs (d’indication) intrinsèques (ISO 4064-
1:2014|OIML R 49-1:2013, 7.2.3)
7.4.1 Objectif de l’essai
Déterminer les erreurs (d’indication) intrinsèques d’un compteur d’eau et les effets de l’orientation du
compteur sur l’erreur (d’indication).
7.4.2 Préparation
7.4.2.1 Description du montage d’essai
La méthode spécifiée ici pour déterminer les erreurs (d’indication) du compteur est la méthode dite de
«collecte», selon laquelle la quantité d’eau écoulée à travers un compteur d’eau est collectée dans un
ou plusieurs récipients de collecte, puis déterminée par volumétrie ou par pesée. D’autres méthodes
peuvent être utilisées, à condition que les exigences de 7.4.2.2.6.1 soient satisfaites.
10 © ISO 2014 – Tous droits réservés

Le contrôle des erreurs (d’indication) consiste à comparer les indications de volume données par le
compteur dans les conditions de référence avec un dispositif de référence étalonné.
Pour les besoins de ces essais, il convient de soumettre à essai au moins un compteur sans ses dispositifs
auxiliaires temporaires fixés (s’il en est équipé), à moins que ces dispositifs soient essentiels pour les
essais du compteur.
Le montage d’essai comprend en général:
a) une alimentation d’eau (réservoir non pressurisé, réservoir pressurisé, pompe, etc.);
b) une tuyauterie;
c) un dispositif de référence étalonné (capacité jaugée étalonnée, système de pesée, compteur de
référence, etc.);
d) un dispositif de chronométrage de l’essai;
e) un dispositif d’automatisation des essais (si nécessaire);
f) un dispositif de mesure de la température de l’eau;
g un dispositif de mesure de la pression de l’eau;
h) un dispositif de détermination de la densité, si nécessaire;
i) un dispositif de détermination de la conductivité, si nécessaire.
7.4.2.2 Tuyauterie
7.4.2.2.1 Description
La tuyauterie dont inclure:
a) une section d’essai dans laquelle le ou les compteurs sont placés;
b) un dispositif de réglage du débit;
c) un ou deux dispositifs d’isolation;
d) un dispositif de détermination du débit;
et, si nécessaire:
e) un dispositif de contrôle du remplissage de la tuyauterie à un niveau de référence avant et après
chaque essai;
f) un ou plusieurs dispositifs d’évacuation d’air;
g) un dispositif de non-retour;
h) un séparateur d’air;
i) un filtre.
Pendant l’essai, il ne doit y avoir aucune fuite, entrée et écoulement de flux soit entre le ou les compteurs
et le dispositif de référence, soit depuis le dispositif de référence.
7.4.2.2.2 Section d’essai
La section d’essai doit inclure, en plus du ou des compteurs:
a) une ou plusieurs prises de pression pour mesurer la pression, une prise de pression étant située en
amont et à proximité du (premier) compteur;
b) un dispositif de mesure de la température de l’eau à proximité de l’entrée du (premier) compteur.
La présence de composants ou de dispositifs de tuyauterie placés dans ou à proximité de
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...

Frequently Asked Questions

ISO 4064-2:2014 is a standard published by the International Organization for Standardization (ISO). Its full title is "Water meters for cold potable water and hot water - Part 2: Test methods". This standard covers: ISO 4064-2:2014|OIML R 49-2:2013 is applicable to the type evaluation and initial verification testing of water meters for cold potable water and hot water as defined in ISO 4064‑1:2014|OIML R 49‑1:2013. OIML Certificates of Conformity can be issued for water meters under the scope of the OIML Certificate System, provided that ISO 4064-2:2014|OIML R 49-2:2013, ISO 4064‑1:2014|OIML R 49‑1:2013 and ISO 4064‑3:2014|OIML R 49‑3:2013 are used in accordance with the rules of the system. ISO 4064-2:2014|OIML R 49-2:2013 sets out details of the test programme, principles, equipment and procedures to be used for the type evaluation, and initial verification of a meter type. The provisions of ISO 4064-2:2014|OIML R 49-2:2013 also apply to ancillary devices, if required by national regulations. The provisions include requirements for testing the complete water meter and for testing the measurement transducer (including the flow or volume sensor) and the calculator (including the indicating device) of a water meter as separate units.

ISO 4064-2:2014|OIML R 49-2:2013 is applicable to the type evaluation and initial verification testing of water meters for cold potable water and hot water as defined in ISO 4064‑1:2014|OIML R 49‑1:2013. OIML Certificates of Conformity can be issued for water meters under the scope of the OIML Certificate System, provided that ISO 4064-2:2014|OIML R 49-2:2013, ISO 4064‑1:2014|OIML R 49‑1:2013 and ISO 4064‑3:2014|OIML R 49‑3:2013 are used in accordance with the rules of the system. ISO 4064-2:2014|OIML R 49-2:2013 sets out details of the test programme, principles, equipment and procedures to be used for the type evaluation, and initial verification of a meter type. The provisions of ISO 4064-2:2014|OIML R 49-2:2013 also apply to ancillary devices, if required by national regulations. The provisions include requirements for testing the complete water meter and for testing the measurement transducer (including the flow or volume sensor) and the calculator (including the indicating device) of a water meter as separate units.

ISO 4064-2:2014 is classified under the following ICS (International Classification for Standards) categories: 91.140.60 - Water supply systems. The ICS classification helps identify the subject area and facilitates finding related standards.

ISO 4064-2:2014 has the following relationships with other standards: It is inter standard links to ISO 4064-2:2024, ISO 4064-2:2005, ISO 4064-3:2005. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

You can purchase ISO 4064-2:2014 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of ISO standards.