ISO 4064-5:2014 applies to water meters used to meter the volume of cold potable water and hot water flowing through a fully charged, closed conduit. These water meters incorporate devices which indicate the integrated volume. ISO 4064-5:2014 specifies criteria for the selection of single, combination and concentric water meters, associated fittings, installation, special requirements for meters, and the first operation of new or repaired meters to ensure accurate constant measurement and reliable reading of the meter. In addition to meters based on mechanical principles, ISO 4064-5:2014 also applies to water meters based on electrical or electronic principles, and to water meters based on mechanical principles incorporating electronic devices, used to measure the volume of cold potable water and hot water. It also applies to electronic ancillary devices. Ancillary devices are optional. However, national or international regulations may make some ancillary devices mandatory in relation to the utilization of the water meter. The recommendations of ISO 4064-5:2014 apply to water meters, irrespective of technology, defined as integrating measuring instruments continuously determining the volume of water flowing through them.

  • Standard
    12 pages
    English language
    sale 15% off
  • Standard
    13 pages
    French language
    sale 15% off

ISO 4064-3:2014|OIML R 49-3:2013 specifies a test report format to be used in conjunction with ISO 4064-1:2014|OIML R 49-1:2013 and ISO 4064-2:2014|OIML R 49-2:2013 for water meters for cold potable water and hot water.

  • Standard
    71 pages
    English language
    sale 15% off
  • Standard
    97 pages
    French language
    sale 15% off

ISO 4064-4:2014 applies to water meters used to meter the volume of cold potable water and hot water flowing through a fully charged, closed conduit. These water meters incorporate devices which indicate the integrated volume. ISO 4064-4:2014 specifies technical characteristics and pressure loss requirements for meters for cold potable water and hot water. It applies to water meters which can withstand: a) a maximum admissible working pressure (MAP) equal to at least 1 MPa [0,6 MPa for meters for use with pipe nominal diameters (DNs) ≥500 mm]; b) a maximum admissible temperature (MAT) for cold potable water meters of 30 °C; c) a MAT for hot water meters up to 180 °C, depending on class. In addition to meters based on mechanical principles, ISO 4064-4:2014 also applies to water meters based on electrical or electronic principles, and to water meters based on mechanical principles incorporating electronic devices, used to meter the volume flow of hot water and cold potable water. It also applies to electronic ancillary devices. As a rule ancillary devices are optional. However, national or international regulations may make some ancillary devices mandatory in relation to the utilization of the water meter.

  • Standard
    26 pages
    English language
    sale 15% off
  • Standard
    27 pages
    French language
    sale 15% off

ISO 4064-2:2014|OIML R 49-2:2013 is applicable to the type evaluation and initial verification testing of water meters for cold potable water and hot water as defined in ISO 4064‑1:2014|OIML R 49‑1:2013. OIML Certificates of Conformity can be issued for water meters under the scope of the OIML Certificate System, provided that ISO 4064-2:2014|OIML R 49-2:2013, ISO 4064‑1:2014|OIML R 49‑1:2013 and ISO 4064‑3:2014|OIML R 49‑3:2013 are used in accordance with the rules of the system. ISO 4064-2:2014|OIML R 49-2:2013 sets out details of the test programme, principles, equipment and procedures to be used for the type evaluation, and initial verification of a meter type. The provisions of ISO 4064-2:2014|OIML R 49-2:2013 also apply to ancillary devices, if required by national regulations. The provisions include requirements for testing the complete water meter and for testing the measurement transducer (including the flow or volume sensor) and the calculator (including the indicating device) of a water meter as separate units.

  • Standard
    101 pages
    English language
    sale 15% off
  • Standard
    104 pages
    French language
    sale 15% off

ISO 4064-1:2014|OIML R 49-1:2013 specifies metrological and technical requirements of water meters for cold potable water and hot water flowing through a fully charged, closed conduit. These water meters incorporate devices which indicate the integrated volume. In addition to water meters based on mechanical principles, ISO 4064-1:2014|OIML R 49-1:2013 applies to devices based on electrical or electronic principles, and mechanical principles incorporating electronic devices, used to measure the volume of cold potable water and hot water. ISO 4064-1:2014|OIML R 49-1:2013 also applies to electronic ancillary devices. Ancillary devices are optional. However, it is possible for national or regional regulations to make some ancillary devices mandatory in relation to the utilization of water meters.

  • Standard
    38 pages
    English language
    sale 15% off
  • Standard
    39 pages
    French language
    sale 15% off

ISO 22158:2011 specifies the minimum communication requirements for water meters which have the capability to exchange or provide data by means of an electronic interface. ISO 22158:2011 only specifies the interface conditions present at the electrical and electronic connections of water meters and does not prescribe any specific equipment such as transponders and inductive pads, which might be connected to the water meter for automatic meter reading or remote meter reading purposes.

  • Standard
    52 pages
    English language
    sale 15% off
  • Standard
    55 pages
    French language
    sale 15% off

ISO 4064-2:2005 specifies criteria for the selection of single, combination and concentric water meters, associated fittings, installation, special requirements for meters and the first operation of new or repaired meters to ensure accurate constant measurement and reliable reading of the meter. ISO 4064-2:2005 also applies to water meters, based on electrical or electronic principles and to water meters based on mechanical principles incorporating electronic devices, used to meter the actual volume flow of cold potable water. It also applies to electronic ancillary devices. The recommendations of this ISO 4064-2:2005 apply to water meters, irrespective of technology, defined as integrating measuring instruments continuously determining the volume of water flowing through them.

  • Standard
    10 pages
    English language
    sale 15% off
  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

ISO 4064-1:2005 specifies terminology, technical characteristics, metrological characteristics and pressure loss requirements for cold potable water and hot water meters. It applies to water meters that can withstand maximum admissible working pressures (MAP) at least 1 MPa (0,6 MPa for meters for use with pipe nominal diameters, DN at least 500 mm) and a maximum admissible temperature, MAT, for cold potable water meters of 30 ºC and for hot water meters up to 180 ºC, depending on class. ISO 4064-1:2005 also applies to water meters, based on electrical or electronic principles and to water meters based on mechanical principles incorporating electronic devices, used to meter the actual volume flow of cold potable water and hot water. It also applies to electronic ancillary devices. Generally ancillary devices are optional. The specifications of ISO 4064-1:2005 apply to water meters, irrespective of technology, defined as integrating measuring instruments continuously determining the volume of water flowing through them.

  • Standard
    42 pages
    English language
    sale 15% off
  • Standard
    46 pages
    English language
    sale 10% off
    e-Library read for
    1 day

ISO 4064-3:2005 specifies the test methods and means to be employed in determining the principal characteristics of water meters. ISO 4064-3:2005 is applicable to cold potable water and hot water concentric and combination meters, which can withstand maximum admissible working pressures equal to at least 1 MPa (10 bar) (0,6 MPa (6 bar) for meters greater than DN 500 and a maximum admissible temperature for cold potable water meters of 30 °C and for hot water meters of up to 180 °C, depending on the class. ISO 4064-3:2005 also applies to water meters based on electrical or electronic principles and to water meters based on mechanical principles incorporating electrical devices, used to meter the actual volume flow of cold potable water and hot water.

  • Standard
    71 pages
    English language
    sale 15% off
  • Standard
    76 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    7 pages
    English language
    sale 15% off
  • Standard
    7 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    7 pages
    French language
    sale 15% off
  • Standard
    14 pages
    English language
    sale 15% off
  • Standard
    14 pages
    French language
    sale 15% off
  • Standard
    4 pages
    English language
    sale 15% off
  • Standard
    4 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    4 pages
    French language
    sale 15% off
  • Standard
    24 pages
    English language
    sale 15% off
  • Standard
    24 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    24 pages
    French language
    sale 15% off
  • Standard
    5 pages
    English language
    sale 15% off
  • Standard
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    5 pages
    French language
    sale 15% off

Deals with terminology, technical characteristics, metrological characteristics and pressure loss. Applies to water meters of various metrological classes which can withstand permanent flow-rates from 0,6 m^3/h to 4000 m^3/h, maximum admissible working pressures equal to or greater than 10 bar and a maximum admissible temperature of 30 °C. Legal requirements take precedence over the recommendations of this part.

  • Standard
    10 pages
    English language
    sale 15% off
  • Standard
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    10 pages
    French language
    sale 15% off

The tests are related with determination of measurement errors, change-over flow rates, pressure, pressure loss, and accelerated wear. Also gives examples of test programmes.

  • Standard
    6 pages
    English language
    sale 15% off
  • Standard
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    6 pages
    French language
    sale 15% off
  • Standard
    6 pages
    French language
    sale 15% off
  • Standard
    16 pages
    English language
    sale 15% off
  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    16 pages
    French language
    sale 15% off
  • Standard
    2 pages
    English language
    sale 15% off
  • Standard
    2 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    2 pages
    French language
    sale 15% off
  • Standard
    2 pages
    French language
    sale 15% off