SIST EN 14716:2005
(Main)Stretched ceilings - Requirements and test methods
Stretched ceilings - Requirements and test methods
This document specifies the characteristics, specifications and test methods for stretched ceilings made up of
single or multi-layer sheets, coated fabrics or fabrics made up of coated or monofilament yarn with a fastening
system.
It also specifies the method of conformity assessment for stretched ceilings.
Spanndecken - Anforderungen und Prüfverfahren
Diese Europäische Norm legt die Kenndaten, Anforderungen und Prüfverfahren für Spanndecken fest, die aus einer bzw. mehreren Schichten Folie, beschichteten Gewebe bzw. Gewebe aus beschichteten Fasern (Garnen) oder beschichteten Einzelfäden (Monofilament) und einem Befestigungssystem zusammengesetzt sind.
Des Weiteren werden die Verfahren zur Konformitätsbewertung der Spanndecken festgelegt.
Plafonds tendus - Exigences et méthodes d'essai
Napeti stropovi – Zahteve in preskusne metode
General Information
Relations
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Stretched ceilings - Requirements and test methodsNapeti stropovi – Zahteve in preskusne metodePlafonds tendus - Exigences et méthodes d'essaiSpanndecken - Anforderungen und PrüfverfahrenTa slovenski standard je istoveten z:EN 14716:2004SIST EN 14716:2005en91.060.30ICS:SLOVENSKI
STANDARDSIST EN 14716:200501-februar-2005
EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 14716December 2004ICS 91.060.30English versionStretched ceilings - Requirements and test methodsPlafonds tendus - Exigences et méthodes d'essaiSpanndecken - Anforderungen und PrüfverfahrenThis European Standard was approved by CEN on 22 October 2004.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the Central Secretariat or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the officialversions.CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France,Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia,Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2004 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 14716:2004: E
EN 14716:2004 (E) 2 Contents Page Foreword.5 1 Scope.6 2 Normative references.6 3 Terms and definitions.7 4 Requirements relating to sheets and coated fabrics or fabrics made up of coated yarn or monofilaments.7 4.1 Essential requirements.7 4.1.1 Reaction to fire.7 4.1.2 Release of other dangerous substances.8 4.1.3 Water vapour permeability.10 4.2 Requirements of single or multi-layered sheets.10 4.3 Requirements of coated fabrics and fabrics made up of coated yarn or monofilaments.10 4.4 Requirements of attachment systems (edge profiles and anchoring devices).11 4.4.1 Suitability for dismantling and re- assembly.11 4.4.2 Mechanical strength.11 5 Assessment of conformity.12 5.1 General.12 5.2 Type tests.12 5.2.1 Initial type tests.12 5.2.2 Sampling, tests and conformity criteria.12 6 Marking and data sheet.13 6.1 Marking of the product.13 6.2 Data sheet.13 Annex A (normative)
SBI test.14 Annex B (normative)
Determination of the mass per unit area and thickness of the sheets.18 B.1 Determination of the mass per unit area.18 B.1.1 Apparatus.18 B.1.2 Test pieces.18 B.1.3 Conditioning.18 B.1.4 Procedure.18 B.1.5 Calculation and expression of results.18 B.2 Determination of the thickness.19 B.2.1 Apparatus.19 B.2.2 Conditioning.19 B.2.3 Procedure.19 B.2.4 Calculation and expression of results.19 B.3 Test report.19 Annex C (normative)
Determination of dimensional stability after exposure to moisture.20 C.1 Scope.20 C.2 Principle.20 C.3 Apparatus and reagents.20 C.3.1 Enclosure (see Figure C.1).20 C.3.2 Test solution.20 C.4 Preparation of the test pieces.21 C.4.1 General.21 C.4.2 Stretched ceiling.21 C.4.3 Related materials.21
EN 14716:2004 (E) 3 C.5 Procedure.21 C.6 Expression of results.21 C.7 Test report.21 Annex D Determination of the operating stress.24 D.1 Determination of the tensile strain at break.24 D.1.1 Preparation of the test pieces.24 D.1.2 Procedure.26 D.2 Calculation of the rate of elongation resulting in the length and the width of a sample of single or multi-layered sheet (see Figure D.6).26 D.2.1 Definition.26 D.2.2 Schematic presentation of the calculation.28 D.2.3 Calculation of the reduction of lo (Rvl %) during the elongation of Lo.29 D.2.4 Calculation of the reduction of Lo (RvL%) during the elongation of lo.30 D.2.5 Calculation of the percentage elongation resulting in the length and the width of the sheet.31 D.3 Numerical application.31 D.3.1 Hypothesis.31 D.3.2 Calculation of lo and Lo.32 D.3.3 Calculation of Al % and AL %.32 D.3.4 Calculation of the percentage reduction Rvl % of lo according to Poisson's ratio.33 D.3.5 Calculation of the width l’ reduced by Poisson's ratio.33 D.3.6 Calculation of the resulting percentage elongation in width: AlR %.33 D.3.7 Calculation of the percentage reduction Rvl% of Lo according to Poisson's ratio.33 D.3.8 Calculation of the reduced width l’ by Poisson's ratio.34 D.3.9 Calculation of the resulting percentage elongation in the length and the width of the sample.34 D.4 Determination of the operating stress.34 Annex E (normative)
Determination of dimensional changes after exposure to heat (kaolin bed method).36 E.1 Principle.36 E.2 Apparatus.36 E.3 Test pieces.36 E.3.1 Shape and dimensions.36 E.3.2 Taking of test pieces.36 E.4 Procedure.37 E.4.1 Test temperature.37 E.4.2 Test.37 E.5 Expression of results.37 E.6 Test report.38 Annex F (normative)
Method of assessing the weldability of sheets assembled by the high frequency welding process.39 F.1 Scope.39 F.2 Definitions.39 F.2.1 General.39 F.3 Principles used for assessing HF weldability.40 F.3.1 Methodology.40 F.3.2 HF welding criteria.40 F.4 Welding strips.42 F.4.1 Shape and dimensions of the strips.42 F.4.2 Taking of test pieces.42 F.5 Procedure.43 F.5.3 Weld quality.44 F.6 Expression of results.45 F.6.1 Assessment of weldability.45 Annex G Factory production control.50 G.1 General.50
EN 14716:2004 (E) 4 G.2 Control of the raw materials.50 G.3 Control of the procedure.50 G.4 Calibration plan.50 G.5 Testing of the finished products.51 G.5.1 Direct testing.51 G.5.2 Indirect evaluation.51 G.6 Inspection and testing.51 G.7 Traceability.51 Annex ZA (informative)
Clauses of this European Standard addressing provisions of the EU Construction Products Directive.52 ZA.1 Scope and relevant characteristics.52 ZA.2 Procedure for attestation of conformity of stretched ceilings.53 ZA.2.1 Systems of attestation of conformity.53 ZA.2.2 EC certificate and declaration of conformity.56 ZA.3 CE marking and labelling.57 Bibliography.59
EN 14716:2004 (E) 5 Foreword This document (EN 14716:2004) has been prepared by Technical Committee CEN/TC BT/TF 119 “Stretched ceilings”, the secretariat of which is held by AFNOR. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by June 2005, and conflicting national standards shall be withdrawn at the latest by June 2005. This European Standard has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirements of EC Directive(s). For relationship with EC Directive(s), see informative Annex ZA, which is an integral part of this standard. It does not supersede any existing standard. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom.
EN 14716:2004 (E) 6 1 Scope This document specifies the characteristics, specifications and test methods for stretched ceilings made up of single or multi-layer sheets, coated fabrics or fabrics made up of coated or monofilament yarn with a fastening system. It also specifies the method of conformity assessment for stretched ceilings. 2 Normative references The following referenced documents are indispensable for the application of this document.
For dated references, only the edition cited applies.
For undated references, the latest edition of the referenced document (including any amendments) applies. EN 1875-3, Rubber- or plastics-coated fabrics - Determination of tear strength. Part 3: Trapezoidal method. EN 12149, Wall coverings in roll form - Determination of migration of heavy metals and certain other elements, of vinyl chloride monomer and of formaldehyde release. EN 12280-1, Rubber- or plastics-coated fabrics - Accelerated ageing tests - Part 1: Heat ageing. EN 13238, Reaction to fire tests for building products - Conditioning procedures and general rules for selection of substrates. EN 13501-1, Fire classification of construction products and building elements - Part 1:
Classification using test data from
reaction to fire tests. EN 13823, Reaction to fire tests for building products - Building products excluding floorings exposed to the hermal attack
by a single burning item. EN ISO 105-B02, Textiles - Tests for colour fastness - Part B02: Colour fastness to artificial light: Xenon arc fading lamp test (ISO 105-B02:1994,
including Amendment 1:1998). EN ISO 527-1, Plastics - Determination of tensile properties - Part 1: General principles (ISO 527-1:1993 including Corr 1:1994). EN ISO 527-3, Determination of tensile properties - Part 3: Test conditions for films and sheets
(ISO 527-3:1995).
EN ISO 846, Plastics - Evaluation of the action of microorganisms (ISO 846:1997). EN ISO 1182, Reaction to fire tests for building products - Non-combustibility test
(ISO 1182:2002). EN ISO 1421, Rubber- or plastics-coated fabrics - Determination of tensile strength and elongation at break (ISO 1421:1998). EN ISO 1716, Reaction to fire tests for building products - Determination of the heat of combustion
(ISO 1716:2002). EN ISO 2286-2, Rubber- or plastics-coated fabrics - Determination of roll characteristics - Part 2: Methods for determination of total mass per unit area, mass per unit area of coating and mass per unit area of substrate (ISO 2286-2:1998). EN ISO 9001, Quality management systems - Requirements (ISO 9001:2000).
EN 14716:2004 (E) 7 EN ISO 11925-2, Reaction to fire tests - Ignitability of building products subjected to direct impingement of flame - Part 2:
Single-flame source (ISO 11925-2:2002).
ISO 2528:1995, Sheet materials - Determination of water vapour transmission rate - Gravimetric (dish) method.
3 Terms and definitions For the purposes of this document, the following terms and definitions apply: 3.1 stretched ceilings ceiling coverings comprising a continuous area obtained from one width or assembled widths kept under tension at its edges by a fastening system permitting dismantling and re-assembly These widths may be single or multi-layered sheets, coated fabrics or fabrics made up of coated yarn or monofilaments. Stretched ceilings may be perforated or not 3.2 product family total range of products within specific variability limits (defined by the manufacturer or a technical specification) of the product parameters and, if appropriate, of the final use parameters for which the specified safety characteristics do not change (do not deteriorate) This means that the test results obtained for one product in the family remain valid for all the products in the family 3.3 edge profile element fixed at the periphery of the ceiling to keep the ceiling stretched 3.4 anchoring device element connecting the stretched ceiling to the edge profile 4 Requirements relating to sheets and coated fabrics or fabrics made up of coated yarn or monofilaments 4.1 Essential requirements 4.1.1 Reaction to fire 4.1.1.1 Preparation and conditioning of test pieces The test pieces shall be conditioned prior to the test in accordance with EN 13238. 4.1.1.2 Ignitability test The ignitability test shall be carried out in accordance with EN ISO 11925-2. The flame shall be applied to the surface of the test piece fixed on the test piece holder by means of small pins incorporated in the surface of the U-shaped frame
EN 14716:2004 (E) 8 4.1.1.3 SBI "Single Burning Item" test Carry out the reaction to fire test in accordance with EN 13823. The stretched ceilings shall be tested perpendicularly in the test piece holder trolley for the SBI comprising one small wing (550 ± 5) mm × (1 500 ± 5) mm and one large wing (1 000 ± 5) mm × (1 500 ± 5) mm. a) In the case of single or multi-layered sheets, take 850 mm × 1 800 mm of the sheet to make the small
wing and 1 300 mm × 1 800 mm to make the large wing. Stretch the sheet in the transverse direction across a calcium silicate panel with a tensile force of 30 daN/m determined in accordance with EN ISO 527-3.
There shall be an air gap of 40 mm between the stretched ceiling and the substrate when assembling the ceiling. This air gap is obtained by means of a calcium silicate frame of desired thickness fixed to the perimeter of the substrate of the small and the large wing. The final configuration may be obtained by pinching the stretched ceiling at the back of the substrate by means of an aluminium track and a PVC ring. Adequate tension shall be applied to obtain a satisfactory degree of flatness and no creasing over the whole of the exposed surface (see Figure A.1 in Annex A). b) In the case of coated fabrics or those made of coated yarn or monofilaments, take a 1 500 mm × 1 500 mm test piece. Fix the test piece to a metallic frame (see Figures A.2, A.3 and A.4 in Annex A). This frame comprises an assembly of stainless steel tubes of rectangular cross-section forming two perpendicular wings, one small and one large. Attach the test piece to the peripheral members of the frame by means of the steel pins.
Prior to the test, the test piece shall be adequately stretched and flat so that no more that 30 % of the total exposed surface shrinks by more than 10 mm from the coplanar vertical plane at the back of the U-profile Then place the frame against the U-profile on the test piece holder trolley. To be representative of the final use, conduct the test with a ventilated space 80 mm wide at the back of the test piece in accordance with EN 13823. Attach two calcium silicate walls made up of one small wing of (580 ± 5) mm × (1 500 ± 5) mm and one large wing of (1 080 ± 5) mm × (1 500 ± 5) mm vertically 80 mm from the test piece. The sides furthest away from the angle and the spaces behind each wing shall be left open. 4.1.1.4 Requirements If the manufacturer wishes to make a declaration of the reaction to fire performance (i.e. if the stretched ceiling is subject to regulations), the stretched ceilings shall be subjected to the test and be classified in accordance with the requirements of EN 13501-1 and the resulting class shall be declared. If it is decided not to declare a reaction to fire performance, i.e. to place a product family on the market as a class F product, no test is required for this product family. 4.1.2 Release of other dangerous substances 4.1.2.1 Heavy metals and other elements 4.1.2.1.1 Requirements The migration of heavy metals and other elements, expressed in mg/kg of stretched ceiling, shall not exceed the values given in Table 1 (after correction as specified in 4.1.2.1.2) when measured in accordance with test A in EN 12149.
EN 14716:2004 (E) 9 If none of these substances is added during manufacture and if the raw materials are certified by the supplier as not containing these substances, the test is not necessary. 4.1.2.1.2 Interpretation of results The analytical results obtained in the tests specified in EN 12149 shall be corrected by subtracting the analytical correction factors given in Table 2 to obtain a corrected analytical result. The stretched ceilings are considered as satisfying the requirements of this document if the corrected analytical result is equal to or less than the limits indicated in Table 1. NOTE 1 Given the reliability of the methods specified in this EN 12149, it is necessary to use the corrected analytical results to take into account the results of the interlaboratory tests (see Annex D of EN 71-3). Example: analytical result for lead: 120 mg/kg. Corresponding analytical correction in Table 2: 30 %. Corrected analytical result = 120 - (120 × 30) / 100 = 120 - 36 = 84 mg/kg. This is considered to meet the requirements of the standard (lead: 90 mg/kg). NOTE 2 The measuring methods used in EN 12149 are derived directly from EN 71-3 on the safety of toys. Annex D of EN 71-3, in particular D.4 "Statistical uncertainty of the test procedure and interpretation of results", justifies the introduction of a correction factor. Table 1 — Maximum migration of heavy metals and other elements Heavy metal or element Symbol Maximum migration in mg/kg of stretched ceiling Antimony
Sb 60 Arsenic
As 25 Barium Ba 500 Cadmium Cd 25 Chromium Cr 60 Lead Pb 90 Mercury Hg 20 Selenium Se 165 Table 2 — Analytical correction factor Element Sb As Ba Cd Cr Pb Hg Se Analytical correction factor (in percentage) 60 60 30 30 30 30 50 60 4.1.2.2 Vinyl chloride monomer The maximum content of vinyl chloride monomer shall be less than 10 mg/kg measured as described in test B of EN 12149. If vinyl chloride or the products containing vinyl chloride are not added during manufacture and if the raw materials are certified by the supplier as containing less than 10 mg/kg of vinyl chloride, the test is not necessary.
EN 14716:2004 (E) 10 4.1.3 Water vapour permeability Stretched ceilings in the form of single or multi-layered sheets and full coated fabrics have a water vapour permeability of < 50 g/m2/24 h (measured in accordance with the conditions of procedure B in ISO 2528) wh
...