SIST EN 16165:2021
(Main)Determination of slip resistance of pedestrian surfaces - Methods of evaluation
Determination of slip resistance of pedestrian surfaces - Methods of evaluation
This document specifies test methods for the determination of the slip resistance of surfaces in the most commonly encountered situations in which pedestrians walk.
NOTE It is also possible to use this document for measurements where persons might walk on trafficked areas.
Bestimmung des Gleitwiderstandes von Fußgängerbereichen - Ermittlungsverfahren
Dieses Dokument legt Prüfverfahren zur Bestimmung des Gleitwiderstands von Oberflächen für die am häufigsten auftretenden Situationen, in denen Fußgänger gehen, fest.
ANMERKUNG Es ist auch möglich, dieses Dokument für Messungen anzuwenden, bei denen Personen möglicherweise auf Verkehrsflächen gehen.
Détermination de la résistance à la glissance des surfaces piétonnières - Méthodes d'évaluation
Le présent document spécifie les méthodes d’essai pour la détermination de la résistance à la glissance des surfaces sur lesquelles des piétons marchent dans les situations les plus courantes.
NOTE Il est également possible d’utiliser le présent document pour les mesurages aux endroits où des personnes peuvent marcher sur des zones de circulation.
Ugotavljanje odpornosti talnih površin proti zdrsu - Metoda vrednotenja
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
SIST EN 16165:2021
01-december-2021
Nadomešča:
SIST-TS CEN/TS 16165:2016
Ugotavljanje odpornosti talnih površin proti zdrsu - Metoda vrednotenja
Determination of slip resistance of pedestrian surfaces - Methods of evaluation
Bestimmung des Gleitwiderstandes von Fußgängerbereichen - Ermittlungsverfahren
Détermination de la résistance à la glissance des surfaces piétonnières - Méthodes
d'évaluation
Ta slovenski standard je istoveten z: EN 16165:2021
ICS:
17.040.20 Lastnosti površin Properties of surfaces
93.080.10 Gradnja cest Road construction
SIST EN 16165:2021 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
SIST EN 16165:2021
---------------------- Page: 2 ----------------------
SIST EN 16165:2021
EN 16165
EUROPEAN STANDARD
NORME EUROPÉENNE
October 2021
EUROPÄISCHE NORM
ICS 17.040.20; 91.060.30; 93.080.10 Supersedes CEN/TS 16165:2016
English Version
Determination of slip resistance of pedestrian surfaces -
Methods of evaluation
Détermination de la résistance à la glissance des Bestimmung der Rutschhemmung von Fußböden -
surfaces piétonnières - Méthodes d'évaluation Ermittlungsverfahren
This European Standard was approved by CEN on 25 July 2021.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this
European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references
concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN
member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by
translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management
Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and
United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2021 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 16165:2021 E
worldwide for CEN national Members.
---------------------- Page: 3 ----------------------
SIST EN 16165:2021
EN 16165:2021 (E)
Contents Page
European foreword . 3
Introduction . 4
1 Scope . 5
2 Normative references . 5
3 Terms and definitions . 5
3.1 General terms . 5
3.2 Terms related to ramp tests . 6
3.3 Terms related to pendulum tests . 6
3.4 Terms related to tribometer tests . 6
4 Test methods . 7
Annex A (normative) Barefoot ramp test . 8
Annex B (normative) Shod ramp test . 14
Annex C (normative) Pendulum test . 21
Annex D (normative) Tribometer test . 46
Bibliography . 53
2
---------------------- Page: 4 ----------------------
SIST EN 16165:2021
EN 16165:2021 (E)
European foreword
This document (EN 16165:2021) has been prepared by Technical Committee CEN/TC 339 “Slip
resistance of pedestrian surfaces - Methods of evaluation”, the secretariat of which is held by DIN.
This European Standard shall be given the status of a national standard, either by publication of an
identical text or by endorsement, at the latest by April 2022, and conflicting national standards shall be
withdrawn at the latest by April 2022.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN shall not be held responsible for identifying any or all such patent rights.
This document supersedes CEN/TS 16165:2016.
The main changes compared to the previous edition are as follows:
a) description of test surface used in the barefoot ramp test and the shod ramp test changed;
b) calibration procedure of the test device used in the barefoot ramp test changed;
c) angles of slip for the three standard surfaces used in the barefoot ramp test changed;
d) procedure for verification and correction in the barefoot ramp test changed;
e) description of the test procedure used in the barefoot ramp test changed;
f) description of test footwear used in the shod ramp test changed;
g) angles of slip for the three standard surfaces used in the shod ramp test changed;
h) information when slider pads and slider assemblies shall be re-prepared or discarded added to the
pendulum test;
i) description of the verification procedure used in the pendulum test and the tribometer test
changed;
j) Reference surfaces for pendulum test and tribometer tests were removed;
k) procedure for the preparation of sliders used in the tribometer test changed.
Any feedback and questions on this document should be directed to the users’ national standards body.
A complete listing of these bodies can be found on the CEN website.
According to the CEN-CENELEC Internal Regulations, the national standards organisations of the
following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria,
Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland,
Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Republic of
North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the
United Kingdom.
3
---------------------- Page: 5 ----------------------
SIST EN 16165:2021
EN 16165:2021 (E)
Introduction
This document describes four test methods commonly used in Europe for the determination of the slip
resistance of floorings.
The method in Annex A describes the test method based on the ramp using water as the test liquid and
with the operator barefoot. This method cannot be used in situ. It is referred to as the “Barefoot ramp
method”.
The method in Annex B describes the test method based on the ramp using oil as the test liquid and
with the operator wearing specified shoes. This method cannot be used in situ. It is referred to as the
“Shod ramp test”.
NOTE Oil is used as the test liquid to make the test more sensitive.
The method in Annex C describes the test method based on the pendulum in dry and wet conditions
using specified rubber sliders. This method can be used in situ. It is referred to as the “Pendulum test”.
The method in Annex D describes the test method based on the tribometer in dry and wet conditions
using specified rubber sliders. This method can be used in situ. It is referred to as the “Tribometer test”.
The purpose of this document is to harmonize the procedures used when using any of the above test
methods. It is not intended to promote any particular test method to Product Group Technical
Committees or to limit their choice.
The test methods given in this document cannot be compared with each other. The results can only be
compared with results that are obtained with the same test method.
4
---------------------- Page: 6 ----------------------
SIST EN 16165:2021
EN 16165:2021 (E)
1 Scope
This document specifies test methods for determining the slip resistance of surfaces used by
pedestrians.
NOTE It is also possible to use this document for measurements where persons might walk on trafficked
areas.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments) applies.
EN ISO 868, Plastics and ebonite — Determination of indentation hardness by means of a durometer
(Shore hardness) (ISO 868)
ISO 48-2, Rubber, vulcanized or thermoplastic — Determination of hardness — Part 2: Hardness between
10 IRHD and 100 IRHD
ISO 48-4, Rubber, vulcanized or thermoplastic — Determination of hardness — Part 4: Indentation
hardness by durometer method (Shore hardness)
ISO 5725-2, Accuracy (trueness and precision) of measurement methods and results — Part 2: Basic
method for the determination of repeatability and reproducibility of a standard measurement method
ISO 5725-5, Accuracy (trueness and precision) of measurement methods and results — Part 5: Alternative
methods for the determination of the precision of a standard measurement method
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
ISO and IEC maintain terminological databases for use in standardization at the following addresses:
— ISO Online browsing platform: available at https://www.iso.org/obp
— IEC Electropedia: available at https://www.electropedia.org/
3.1 General terms
3.1.1
pedestrian surface
surface which is designed for people to walk upon
3.1.2
test liquid
standardized liquid applied on the surface for the purpose of the test
3.1.3
friction
resistance to relative motion between two bodies in contact, e.g. the test slider or the footwear sole and
the pedestrian surface
Note 1 to entry: The frictional force is the force acting tangentially in the contact area.
5
---------------------- Page: 7 ----------------------
SIST EN 16165:2021
EN 16165:2021 (E)
3.1.4
slip
loss of traction which can cause the test persons to lose their footing
3.1.5
slip resistance
measure of dynamic friction between two surfaces in contact with or without the presence of a specified
test liquid
Note 1 to entry: The frictional force opposing movement of an object across a surface, usually with reference to
the sole (including the heel) of a shoe or to the barefoot contact area on a floor. Slip resistance of a pedestrian
surface is the property of the surface which counteracts the relative sliding movement.
3.2 Terms related to ramp tests
3.2.1
angle of slip
lowest angle of the inclined ramp at which the test person reaches the limit of safe walking when
slipping occurs
3.2.2
test person
person who walks on the test surface or standard surface
3.2.3
test walk
walk to determine a single angle of slip
3.3 Terms related to pendulum tests
3.3.1
pendulum test value
PTV
standardized value of the slip resistance as measure of the friction between the slider and the test
surface obtained with the pendulum friction tester which incorporates a slider manufactured of rubber
3.4 Terms related to tribometer tests
3.4.1
dynamic coefficient of friction
μ
quotient of the horizontal frictional force and the vertically acting force between the slider and the
horizontal surface during movement at a constant speed
3.4.2
sliding distance
distance over which the body is pulled during a single measurement
3.4.3
measuring distance
distance over which the sliding friction coefficient is determined
6
---------------------- Page: 8 ----------------------
SIST EN 16165:2021
EN 16165:2021 (E)
3.4.4
measurement series
series consisting of five single measurements on one measuring distance
4 Test methods
Carry out a test according to Annex A to Annex D. If tests are performed in the laboratory, the room
temperature should be (20 ± 5) °C unless otherwise stated.
7
---------------------- Page: 9 ----------------------
SIST EN 16165:2021
EN 16165:2021 (E)
Annex A
(normative)
Barefoot ramp test
A.1 Principle
Two bare-foot test persons are used to determine the angle of slip, while the pedestrian surface
material being tested is continuously coated with water containing a wetting agent. The test persons,
each in turn, facing down the ramp and with an upright posture, move forwards and backwards over
the test surface, as they increase their angle of inclination, until the safe limit of walking is reached and
a slip occurs. The mean angle of slip obtained is used to express the degree of slip resistance. Subjective
influences on the angle of slip are limited by means of a correction procedure.
A.2 Test equipment
A.2.1 Test apparatus with safety devices
The test device (Figure A.1) is a level and torsion-free platform of approximately 600 mm width and
2 000 mm length which can be adjusted longitudinally as a continuous movement to gradients from 0°
to approximately 45°. The lifting stroke is controlled by the test person. An angle indicator on the test
device shall show the platform tilt away from the horizontal plane at an accuracy of ± 0,2°. The test
apparatus shall be rigid such that the angle does not vary by more than ± 0,5° during the walking. The
display of the angle measurement system shall be fixed in such a way that the test person cannot read it
during the test. The test person is safeguarded by railings along the sides and protected from falling by
a safety harness, which shall not cause a hindrance to the test person when walking on the pedestrian
surface material under test.
8
---------------------- Page: 10 ----------------------
SIST EN 16165:2021
EN 16165:2021 (E)
Dimensions in millimetres
Key
1 safety harness and fall arrest system
2 drive unit
3 inclinable walkway area on which the test surface or standard surface is fixed
4 angle indicator
Figure A.1 — Example of a typical test apparatus
A.2.2 Standard surfaces
Three standard surfaces, St-A, St-B and St-C, are used for the training and verification of test persons
and the correction of the test results. The angle of slip (α) of these surfaces are given in Table A.1 and
are specified as angles of slip α , α and α of the three standard surfaces. The critical
S,St-A S,St-B S,St-C
differences of CrD are determined for the three standard surfaces for a significance level of 95 % from
95
the comparison and repetition limits according to ISO 5725-2 or ISO 5725-5. [7]
NOTE The critical difference of CrD95 indicates the spreading of measured values during measurements on
the same object at various test locations, or coincidental deviations during repeated measurements at the same
test location.
9
---------------------- Page: 11 ----------------------
SIST EN 16165:2021
EN 16165:2021 (E)
Table A.1 — Angle of slip and critical difference values of the three standard surfaces
Standard surface (n) Angle of slip α [°] Critical difference
S,n
CrD [°]
95
St-A 12,4 3,9
St-B 20,9 4,3
St-C 26,7 4,4
When testing barefoot, the standard surfaces can become contaminated with body fats/oils. This may
affect the performance of the surface. It is important to know, when verifying or correcting, that any
changes in the surface are due to wear or the operator and not contamination. It is recommended to
thoroughly clean the surfaces regularly.
A.2.3 Test liquid
Aqueous solution of a low foaming non-ionic surfactant such as LS45 (CAS-No. 68439-51-0) in a
concentration of 1 g/l (aqueous solution: 0,1 % LS45 in water) shall be used as the test liquid. Prior to
and during testing the aqueous solution shall be applied at (6,0 ± 1,0) l/min using appropriate means so
as to form a largely uniform distribution of test liquid across the test surface. The temperature range of
the solution shall be in between (29,0 ± 2,0) °C.
The test liquid may only be used once and shall not be re-circulated.
A.2.4 Test surface
The test surface shall have a minimum length of 1 000 mm and a minimum width of 400 mm. The test
surface shall be either self-supporting, or securely mounted on a suitable flat surface.
The test surface shall be clean.
NOTE The floor manufacturer's instructions can be useful for cleaning.
If the slip resistance differs depending on the direction of walking, then it will be necessary to
determine the direction of lowest slip resistance. It is recommended that tests are carried out in at least
two directions (longitudinally and laterally) to establish whether there is directionality of the slip
resistance of the sample. Once a lack of directionality has been established, it is acceptable to test in a
single direction. If the test surface is produced by the customer, they are responsible that the direction
of the lowest slip resistance is mounted in the longitudinal direction of the test surface.
Materials designed to be used in one direction should be tested in the intended direction of use.
A.3 Calibration of the test device
The inclination of the inclinable walkway surface shall be calibrated annually and checked periodically.
A.4 Training of test persons
The test persons shall be trained for the test (e.g. gait, walking speed, skin condition). The training
procedure of the test person shall be carried out as follows:
Each test person j shall walk according to A.5, a) to n) on each standard surface (A.2.2) four times and
the average training values are determined out of the last three values:
α ; αα;
T,St−A,j T,St−B,j T,St−C,j
10
---------------------- Page: 12 ----------------------
SIST EN 16165:2021
EN 16165:2021 (E)
For each test-person the individual differences according to Formula (A.1):
∆αα= −α (n = St-A, St-B and St-C) (A.1)
nj, S,n T,nj,
are calculated and result in:
∆α ; ∆∆αα;
St−A,j St−B,j St−C,j
If each of the individual differences ∆α ; ∆∆αα; are inside of the critical differences,
St−A,j St−B,j St−C,j
the test person is trained for the test.
(see Table A.1) (A.2)
∆≤α CrD
nj; 95
A.5 Test procedure
a) The test surface shall be mounted on the test device so that the direction of the lowest slip
resistance is in the direction of walking movement. For determining the slip resistance
characteristics of surfaces with directional surface profiles or texture, see A.2.4.
b) The test surface (see A.2.4) shall be clean.
c) The test person j shall soak their feet in water containing the test liquid (see A.2.3) for ten minutes
before starting the test.
d) The test person shall put on the harness (see A.2.1). The test person shall then attach to the fall
arrest system (see A.2.1).
e) The test person shall mount the ramp (which shall be set to the horizontal position) so as to stand
on the test surface.
f) Application of the test liquid (see A.2.3).
g) Facing down the ramp and looking at their feet, the test person, using a half-step gait and using the
flat of the foot, shall take a minimum of four steps down the test surface (walking forwards), and
then take half-steps up the test surface (walking backwards) to return to their starting position.
The test person shall walk up and down the test surface twice before raising the ramp by a small
amount. This continues until a slip occurs. When high angles are achieved, the steps for raising the
ramp may be higher in the lower angle area.
h) It is essential to maintain a rhythm of about 144 half steps per minute. A metronome or similar
should be used to keep pace. Above a ramp angle of 20°, the pace is less important.
i) Once a slip occurs the walk shall be repeated at the angle of slip and if a further slip occurs then this
angle is recorded.
j) If there is no second slip the test is continued, raising the angle by a small amount until two slips
occur at the same angle.
k) It is important that around the point of slip the angle is not raised too much in one step.
Incremental rises shall therefore be small at this point.
l) If it is suspected that the angle has been raised by too great an amount around the point of slip then
the angle shall be lowered to below the angle of slip and the run repeated using smaller increments.
11
---------------------- Page: 13 ----------------------
SIST EN 16165:2021
EN 16165:2021 (E)
m) If the test person is still able to walk on the test sample at an angle of 30° then the test shall be
stopped unless there is agreement between parties to go to higher angles.
n) Record the angle, α with i = 1;2;3;4 rounded to the nearest 0,1°.
0,i,j
o) Repeat the procedure (steps d) to n)) from the horizontal or from an angle approximately 10°
below the angle of slip three more times. Discard the first angle of slip with i = 1 and calculate the
mean value α , from the last three angles of slip with i = 2;3;4.
0 j
p) Depending on the mean value α , one of the three standard surfaces shall be selected and mounted
0 j
on the test device for a verification and correction procedure (see Table A.2).
Table A.2 —Selection of a standard surface for correction
Case Standard surface
St-A
α <°16,7
0,j
St-B
16,7° ≤α <23,8°
0,j
St-C
23,8° ≤α
0,j
q) The test steps a) to l) shall be carried out four times on the selected standard surface and given the
angles of slip for correction α with n = St-A, St-B or St-C and i = 1;2;3;4. Discard the first angle
C,ni, ,j
of slip with i = 1 and calculate the mean value from the last three angles of slip with
α α
Cn,,j C,ni,,j
i = 2;3;4.
The test [test steps a) to q)] shall be repeated by a second test person.
A.6 Verification and correction
A.6.1 General
For every single test surface and test person the verification and correction procedure shall be carried
out.
A.6.2 Verification
For each test-person the individual difference between the angle of slip of the standard surface
(Table A.1) and the angle of slip for correction (see A.5 q)) according to Formula (A.3) is calculated:
. (n = St-A, St-B or St-C) (A.3)
∆αα= −α
nj, S,n C,nj,
If the individual difference is inside of the critical difference (see Formula (A.4)) the test person is
verified. The correction according to A.6.3 can be made and the result can be used.
∆≤α CrD (see Table A.1) (A.4)
nj; 95
If the individual difference is higher than the critical difference, the result for that test surface from this
test person has to be discarded and the test person has to be replaced by another test person.
The results of other tested surfaces on that test day, that was verified correctly, are still valid.
12
---------------------- Page: 14 ----------------------
SIST EN 16165:2021
EN 16165:2021 (E)
A.6.3 Correction
For two test persons a correction value, D (D and D ) is calculated for each tested surface from the
j 1 2
value obtained from the selected standard surface. The calculated correction value, D , is added to the
j
mean value of each test surface α giving the corrected value for one test person α (α or α ).
j 1 2
0,j
The calculation of D shall be carried out in accordance with one of the three cases given in Table A.3.
j
Table A.3 — Correction value depending on the size of the mean angle of slip
Case Correction value D for test surface
j
α <°16,7 1
0,j
D 12,4°−α ×
j C,St−A, j
2
16,7° ≤α <23,8° 1
0,j
D 20,9°−α ×
j C,St−B, j
2
1
23,8° ≤α
0,j
D 26,7°−α ×
j C,St−C, j
2
where
α is the mean angle of slip for test person j;
0,j
D is the correction value for test person j for the current test surface;
j
α is the average correction value for test person j walking on standard surface St-A;
C,St-A,j
α is the average correction value for test person j walking on standard surface St-B;
C,St-B,j
α is the average correction value for test person j walking on standard surface St-C.
C,St-C,j
The corrected mean angle of slip of test person 1 (α ) and test person 2 (α ) shall be added together and
1 2
divided by 2 creating the test result α rounded to the nearest 1°.
barefoot
A.7 Test report
The following information shall be given in the test report:
a) reference to this European Standard (including its year of publication);
b) method used (i.e. Annex A);
c) test organization and name of the person responsible for the test;
d) date of test;
e) identity of test surfaces or designation, manufacturer, product, where applicable quality class,
colour and dimensions of products used for the surface (if this information is known);
f) surface structure (e.g. smooth, profiled, structured);
g) ramp test value, α , rounded to the nearest 1 degree.
barefoot
h) any further remarks when appropriate such as, surface conditions tested and cleaning method,
regular maintenance procedures, surface treatments and/or the sampling method.
13
=
=
=
---------------------- Page: 15 ----------------------
SIST EN 16165:2021
EN 16165:2021 (E)
Annex B
(normative)
Shod ramp test
B.1 Principle
Two test persons wearing shoes are used to determine the angle of slip, after the pedestrian surface
material being tested has been evenly coated with oil. The test persons, each in turn, facing down the
ramp and with an upright posture, move forwards and backwards over the test surface, as they increase
their angle of inclination, until the safe limit of walking is reached and a slip occurs. The mean angle of
slip obtained is used to express the degree of slip resistance. Subjective influences on the angle of slip
are limited by means of a correction procedure.
B.2 Test equipment
B.2.1 Test apparatus with safety devices
The test device (Figure B.1) is a level and torsion-free platform of approximately 600 mm width and
2 000 mm length which can be adjusted longitudinally as a continuous movement to gradients from 0°
to approximately 45°. The lifting stroke is controlled by the test person. An angle indicator on the test
device shall show the platform tilt away from the horizontal plane at an accuracy of ± 0,2°. The test
apparatus shall be rigid such that the angle does not vary by more than ± 0,5° during the walking. The
display of the angle measurement system shall be fixed in such a way that the test person cannot read it
during the test.
The test person is safeguarded by railings along the sides and protected from falling by a safety harness
which shall not cause a hindrance to the test person when walking on the pedestrian surface material
under test.
14
---------------------- Page: 16 ----------------------
SIST EN 16165:2021
EN 16165:2021 (E)
Dimensions in millimetres
Key
1 safety harness and fall arrest system
2 drive unit
3 inclinable walkway area on which the test surface or standard surface is fixed
4 angle indicator
Figure B.1 — Example of typical test apparatus
B.2.2 Test surface
The test surface shall have a minimum length of 1 000 mm and a minimum width of 400 mm. The test
surface shall be either self-supporting, or securely mounted on a suitable flat surface.
The test surface shall be clean.
NOTE The floor manufacturer's instructions can be useful for cleaning.
If the slip resistance differs depending on the direction of walking, then it will be necessary to
determine the direction of lowest slip resistance. It is recommended that tests are carried out in at least
two directions (longitudinally and laterally) to establish whether there is directionality of the slip
resistance of the sample. Once a lack of directionality has been established, it is acceptable to test in a
single direction. If the test surface is produced by the customer, they are responsible that the direction
of the lowest slip resistance is mounted in the longitudinal direction of the test surface.
15
---------------------- Page: 17 ----------------------
SIST EN 16165:2021
EN 16165:2021 (E)
Materials designed to be used in one direction should be tested in the intended direction of use.
B.2.3 Test Liquid
Engine oil of SAE viscosity grade 10 W 30 according to SAE J300 [5] shall be used as the test liquid
2
(200 ± 20) ml/m oil shall be evenly brushed onto the test surface prior to test walk of the first test
person and then re-distributed using a brush prior to the test walk of the second test person.
Some surfaces may have an open structure (e.g. grids and gratings) which makes it impossible to
determine how much oil
...
SLOVENSKI STANDARD
oSIST prEN 16165:2020
01-junij-2020
Ugotavljanje odpornosti talnih površin proti zdrsu - Metoda vrednotenja
Determination of slip resistance of pedestrian surfaces - Methods of evaluation
Bestimmung des Gleitwiderstandes von Fußgängerbereichen - Ermittlungsverfahren
Détermination de la résistance à la glissance des surfaces piétonnières - Méthodes
d'évaluation
Ta slovenski standard je istoveten z: prEN 16165
ICS:
17.040.20 Lastnosti površin Properties of surfaces
93.080.10 Gradnja cest Road construction
oSIST prEN 16165:2020 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
oSIST prEN 16165:2020
---------------------- Page: 2 ----------------------
oSIST prEN 16165:2020
DRAFT
EUROPEAN STANDARD
prEN 16165
NORME EUROPÉENNE
EUROPÄISCHE NORM
April 2020
ICS 17.040.20; 91.060.30; 93.080.10 Will supersede CEN/TS 16165:2016
English Version
Determination of slip resistance of pedestrian surfaces -
Methods of evaluation
Détermination de la résistance à la glissance des Bestimmung des Gleitwiderstandes von
surfaces piétonnières - Méthodes d'évaluation Fußgängerbereichen - Ermittlungsverfahren
This draft European Standard is submitted to CEN members for enquiry. It has been drawn up by the Technical Committee
CEN/TC 339.
If this draft becomes a European Standard, CEN members are bound to comply with the CEN/CENELEC Internal Regulations
which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
This draft European Standard was established by CEN in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC
Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and
United Kingdom.
Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are
aware and to provide supporting documentation.
Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without
notice and shall not be referred to as a European Standard.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2020 CEN All rights of exploitation in any form and by any means reserved Ref. No. prEN 16165:2020 E
worldwide for CEN national Members.
---------------------- Page: 3 ----------------------
oSIST prEN 16165:2020
prEN 16165:2020 (E)
Contents Page
European foreword . 5
Introduction . 6
1 Scope . 7
2 Normative references . 7
3 Terms and definitions . 7
3.1 General terms . 7
3.2 Terms related to ramp tests . 8
3.3 Terms related to pendulum tests . 8
3.4 Terms related to tribometer tests . 8
4 Test methods . 9
Annex A (normative) Barefoot ramp test . 10
A.1 Principle . 10
A.2 Test equipment . 10
A.2.1 Test apparatus. 10
A.2.2 Test surface . 11
A.2.3 Contaminant . 12
A.3 Calibration of the test device . 12
A.4 Selecting and checking of the test persons . 12
A.5 Test procedure . 13
A.6 Evaluation . 14
A.7 Test report . 15
Annex B (normative) Shod ramp test . 16
B.1 Principle . 16
B.2 Test equipment . 16
B.2.1 Test apparatus with safety devices . 16
B.2.2 Test surface . 17
B.2.3 Contaminant . 18
B.2.4 Test footwear . 18
B.3 Calibration . 18
B.3.1 General . 18
B.3.2 Validation of the test person . 19
B.4 Test procedure . 20
B.5 Evaluation . 21
B.6 Test report . 22
Annex C (normative) Pendulum test . 23
2
---------------------- Page: 4 ----------------------
oSIST prEN 16165:2020
prEN 16165:2020 (E)
C.1 Principle . 23
C.2 Apparatus . 23
C.2.1 Pendulum friction tester . 23
C.2.2 Additional items required for testing . 28
C.3 Preparation . 28
C.3.1 General . 28
C.3.2 Preparation of the slider . 30
C.3.3 Small units . 32
C.3.4 Flatness of the surface . 32
C.3.5 Profiled surfaces . 32
C.4 Verification . 32
C.5 Conducting the test . 33
C.5.1 Procedure . 33
C.5.2 Checking for error . 34
C.5.3 Calculating the pendulum test value (PTV) . 34
C.6 Pendulum measurements on site, additional information . 35
C.7 Test report . 36
C.8 Pendulum scale dimensions . 37
C.9 Calibration procedure for the pendulum friction tester . 39
C.9.1 General . 39
C.9.2 Pre-calibration verification . 39
C.9.3 Detailed condition check . 39
C.9.4 Checking/setting the centre of gravity of the pendulum arm and slider assembly . 40
C.9.5 Checking/setting the effective spring tension . 42
C.9.6 Checking/setting the slider force/deflection characteristics . 44
C.9.7 Checking/setting the levelness of the frame . 45
C.9.8 Final calibration . 46
C.9.9 Calibration report and marking (external calibration). 46
Annex D (normative) Tribometer test . 48
D.1 Principle . 48
D.2 Apparatus and test equipment . 48
D.2.1 Apparatus . 48
D.3 Test equipment . 49
D.4 Verification and checking . 50
D.4.1 Verification of the load cell . 50
D.4.2 Verification of the slider material and test apparatus . 50
3
---------------------- Page: 5 ----------------------
oSIST prEN 16165:2020
prEN 16165:2020 (E)
D.5 Preparation of the test surface area for laboratory tests . 51
D.6 Preparation of the test surface for on-site tests . 51
D.7 Preparation of the sliders . 52
D.8 Procedure. 52
D.9 Calculation and expression of results . 53
D.10 Test report . 53
Bibliography . 54
4
---------------------- Page: 6 ----------------------
oSIST prEN 16165:2020
prEN 16165:2020 (E)
European foreword
This document (prEN 16165:2020) has been prepared by Technical Committee CEN/TC 339 “Slip
resistance of pedestrian surfaces - Methods of evaluation”, the secretariat of which is held by DIN.
This document is currently submitted to the CEN Enquiry.
This document will supersede CEN/TS 16165:2016.
The main changes compared to the previous edition are as follows:
a) description of test surface used in the barefoot ramp test and the shod ramp test changed;
b) calibration procedure of the test device used in the barefoot ramp test changed:
c) procedure for selecting and checking of test persons used in the barefoot ramp test changed;
d) description of the test procedure used in the barefoot ramp test changed:
e) description of test footwear used in the shod ramp test changed;
f) acceptance angles for the three standard surfaces used in the shod ramp test changed;
g) information when slider pads and slider assemblies shall be re-prepared or discarded added to the
pendulum test;
h) description of the verifaction procedure used in the pendulum test changed;
i) float glass plate removed as reference surface used in the tribometer test;
j) description of the verification of the slider material and test apparatus used in the tribometer test
changed;
k) description of the procedures for the preparation of test surfaces and sliders used in the tribometer
test changed.
5
---------------------- Page: 7 ----------------------
oSIST prEN 16165:2020
prEN 16165:2020 (E)
Introduction
This document describes four test methods commonly used in Europe for the determination of the slip
resistance of floorings.
The method in Annex A describes the test method based on the ramp using water as the contaminant
and with the operator barefoot. This method cannot be used in situ. It is referred to as the “Barefoot
ramp method”.
The method in Annex B describes the test method based on the ramp using oil as the contaminant and
with the operator wearing specified shoes. This method cannot be used in situ. It is referred to as the
“Shod ramp test”.
NOTE Oil is used as the contaminant to make the test more sensitive.
The method in Annex C describes the test method based on the pendulum in dry and wet conditions
using specified rubber sliders. This method can be used in situ. It is referred to as the “Pendulum test”.
The method in Annex D describes the test method based on the tribometer in dry and wet conditions
using specified rubber sliders. This method can be used in situ. It is referred to as the “Tribometer test”.
The purpose of this document is to harmonize the procedures used when using any of the above test
methods. It is not intended to promote any particular test method to Product Group Technical
Committees or to limit their choice.
6
---------------------- Page: 8 ----------------------
oSIST prEN 16165:2020
prEN 16165:2020 (E)
1 Scope
This document specifies test methods for the determination of the slip resistance of surfaces in the most
commonly encountered situations in which pedestrians walk.
NOTE It is also possible to use this document for measurements where persons might walk on trafficked
areas.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments) applies.
EN 438-4, High-pressure decorative laminates (HPL) — Sheets based on thermosetting resins (usually
called laminates) — Part 4: Classification and specifications for compact laminates of thickness 2 mm and
greater
EN ISO 868, Plastics and ebonite — Determination of indentation hardness by means of a durometer
(Shore hardness) (ISO 868)
ISO 5725-2, Accuracy (trueness and precision) of measurement methods and results — Part 2: Basic
method for the determination of repeatability and reproducibility of a standard measurement method
ISO 5725-5, Accuracy (trueness and precision) of measurement methods and results — Part 5: Alternative
methods for the determination of the precision of a standard measurement method
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
ISO and IEC maintain terminological databases for use in standardization at the following addresses:
— ISO Online browsing platform: available at http://www.iso.org/obp
— IEC Electropedia: available at http://www.electropedia.org/
3.1 General terms
3.1.1
pedestrian surface
surface which is designed for people to walk upon
3.1.2
contaminant
material on the surface which is not an inherent part of the surface and which can affect the frictional
properties of that surface
3.1.3
friction
resistance to relative motion between two bodies in contact, e.g. the test slider or the footwear sole and
the pedestrian surface
Note 1 to entry: The frictional force is the force acting tangentially in the contact area.
7
---------------------- Page: 9 ----------------------
oSIST prEN 16165:2020
prEN 16165:2020 (E)
3.1.4
slip
loss of traction which can cause the test persons to lose their footing
3.1.5
slip resistance
measure of dynamic friction between two surfaces in contact with or without the presence of a specified
contaminant
Note 1 to entry: The frictional force opposing movement of an object across a surface, usually with reference to
the sole (including the heel) of a shoe or to the barefoot contact area on a floor. Slip resistance of a pedestrian
surface is the property of the surface which limits the relative sliding movement.
3.2 Terms related to ramp tests
3.2.1
angle of slip
lowest angle of the inclined ramp at which the test person reaches the limit of safe walking when
slipping occurs
3.2.2
test person
person who walks on the test surface or calibration surface
3.2.3
test walk
walk to determine a single angle of slip
3.3 Terms related to pendulum tests
3.3.1
pendulum test value
PTV
standardized value of the slip resistance as measure of the friction between the slider and the test
surface obtained with the pendulum friction tester which incorporates a slider manufactured of rubber
3.4 Terms related to tribometer tests
3.4.1
dynamic coefficient of friction
μ
quotient of the horizontal frictional force and the vertically acting force between the slider and the
horizontal surface during movement at a constant speed
3.4.2
sliding distance
distance over which the body is pulled during a single measurement
3.4.3
measuring distance
distance over which the sliding friction coefficient is determined
8
---------------------- Page: 10 ----------------------
oSIST prEN 16165:2020
prEN 16165:2020 (E)
3.4.4
measurement series
series consisting of five single measurements on one measuring distance
4 Test methods
Carry out a test according to Annex A to Annex D. If tests are performed in the laboratory the room
temperature should be (20 ± 5) °C unless otherwise stated.
9
---------------------- Page: 11 ----------------------
oSIST prEN 16165:2020
prEN 16165:2020 (E)
Annex A
(normative)
Barefoot ramp test
A.1 Principle
Two bare-foot test persons are used to determine the angle of slip, after the pedestrian surface material
being tested has been continuously coated with water containing a wetting agent. The test persons,
each in turn, facing downhill and with an upright posture, move forwards and backwards over the test
surface, as they increase their angle of inclination, until the safe limit of walking is reached and a slip
occurs. The mean angle of slip obtained is used to express the degree of slip resistance. Subjective
influences on the angle of slip are limited by means of a calibration procedure.
A.2 Test equipment
A.2.1 Test apparatus
The test device (Figure A.1) is a level and torsion-free platform of approximately 600 mm width and
2 000 mm length which can be adjusted longitudinally as a continuous movement to gradients from 0°
to approximately 45°. The lifting stroke is controlled by the test person. An angle indicator on the test
device shall show the platform tilt away from the horizontal plane at an accuracy of ± 0,2°. The test
apparatus shall be rigid such that the angle does not vary by more than ± 0,5° during the walking. The
display of the angle measurement system shall be fixed in such a way that the test person cannot read it
during the test. The test person is safeguarded by railings along the sides and protected from falling by
a safety harness which shall not cause a hindrance to the test person when walking on the pedestrian
surface material under test.
10
---------------------- Page: 12 ----------------------
oSIST prEN 16165:2020
prEN 16165:2020 (E)
Dimensions in millimetres
Key
1 safety harness and fall arrest system
2 drive unit
3 inclinable walkway area on which the test surface or verification/calibration surface is fixed
4 angle indicator
Figure A.1 — Example of a typical test apparatus
A.2.2 Test surface
The test surface area shall have a minimum length of 1 000 mm and a minimum width of 400 mm. The
test surface shall be clean. The test surface shall be either self-supporting, or securely mounted on a
suitable flat surface.
If the slip resistance differs depending on the direction of walking, then it will be necessary to
determine the direction of lowest slip resistance. It is recommended that tests are carried out in at least
two directions (longitudinally and laterally) to establish whether there is directionality of the slip
resistance of the sample. Once a lack of directionality has been established, it is acceptable to test in a
single direction. If the test surface is produced by the customer, he is responsible that the direction of
the lowest slip resistance is mounted in the longitudinal direction of the test surface.
Materials designed to be used in one direction should be tested in the direction of slip of the intended
use.
11
---------------------- Page: 13 ----------------------
oSIST prEN 16165:2020
prEN 16165:2020 (E)
A.2.3 Contaminant
Aqueous solution of a low foaming non-ionic surfactant such as LS45 (CAS-No. 68439-51-0) in a
concentration of 1 g/l (aqueous solution: 0,1 % LS45 in water) shall be used as the contaminant. Prior
to and during testing the aqueous solution shall be applied at (6,0 ± 1,0) l/min using appropriate jets so
as to form a largely uniform spray of contaminant across the test specimen. The temperature range of
the solution shall be in between (29,0 ± 2,0) °C.
The contaminant may only be used once and shall not be re-circulated.
A.3 Calibration of the test device
The inclination of the inclinable walkway surface shall be calibrated annually and checked periodically.
When testing barefoot the standard surfaces can become contaminated with body fats/oils. This may
affect the performance of the surface. It is important to know, when calibrating or checking that any
changes in the surface are due to wear or the operator and not contamination and it is recommended
that the surfaces are thoroughly and properly cleaned before use.
A.4 Selecting and checking of the test persons
The test persons shall be qualified and trained for the test (e.g. gait, walking speed, skin condition). This
shall be checked with the following procedure.
Three standard surfaces, St-A, St-B and St-C, are used for the process. The angle of slip (α) of these
surfaces are given in Table A.1 and are specified as acceptance angles α , α and α of the three
S,St-A S,St-B S,St-C
standard surfaces. The critical differences of CrD are determined for the three standard surfaces for a
95
significance level of 95 % from the comparison and repetition limits according to ISO 5725-2 or
ISO 5725-5.
NOTE The critical difference of CrD95 indicates the spreading of measured values during measurements on
the same object at various test locations, or coincidental deviations during repeated measurements at the same
test location.
Table A.1 — Angle of slip and critical difference values of the three standard surfaces
Standard surface α CrD
S,i 95
St-A 12,4° 3,9°
St-B 20,9° 4,3°
St-C 26,7° 4,4°
Each test person j shall walk according to A.5, a) to l) on each standard surface four times and the
average calibration values are determined out of the last three values:
ααα;;
Q,,St−−−A j Q,,St B j Q,St C, j
For each test-person the individual differences according to Formula (A.1):
∆α α−α (A.1)
ij, S,i Q,,ij
(i = St-A, St-B and St-C)
are calculated and result in Formula (A.2):
12
=
---------------------- Page: 14 ----------------------
oSIST prEN 16165:2020
prEN 16165:2020 (E)
∆α ∆α ∆α (A.2)
St− A, j St−B,,j St−C j
∆α ; ∆α ; ∆α
If each of the individual differences are inside of the critical differences the
St−−−A, j St B, j St C, j
test person is qualified for the test. The test person shall be rejected if the condition in Formula (A.3) is
met.
|∆α |> CrD (see Table A.1) (A.3)
ij, 95
This qualification test shall be carried out periodically, at least every 2 months.
The qualification test should not be carried out on every test day.
A.5 Test procedure
a) The test surface shall be mounted on the test device so that the direction of the lowest slip
resistance properties is in the direction of walking movement. For determining the slip resistance
characteristics of surfaces with directional surface profiles or texture, see A.2.2.
b) The test surface (see A.2.2) shall be clean.
c) The test person shall soak their feet in water containing the contaminant for ten minutes before
starting the test.
d) The test person shall put on the harness (see A.2.1). The test person shall then attach to the fall
arrest system (see A.2.1).
e) The test person shall mount the ramp (which shall be set to the
...