Fixed firefighting systems - Condensed aerosol extinguishing systems - Part 1: Requirements and test methods for components

This document specifies requirements, describes test methods for condensed aerosol extinguishing components and covers solely condensed aerosols. This document is not intended to indicate approval of the extinguishants listed herein by the appropriate authorities, as other extinguishants may be equally acceptable. This document is intended as a standard covering solely condensed aerosol. The condensed aerosol generator typically consists of the following main components: a) solid aerosol-forming compound; b) cooling mechanism; c) ignition device(s); d) end plate discharge outlet(s); e) housing; f) mounting bracket. This document does not cover dispersed aerosols. This document requires, as a precaution, that the room is evacuated and sealed off whenever a generator is activated. Precautions include evacuation of the proximity area, criteria for re-entering and other safeguards as stated in Clause 5 of CEN/TR 15276-2:2009.

Ortsfeste Brandbekämpfungsanlagen - Löschanlagen für kondensierte Aerosole - Teil 1: Anforderungen und Prüfverfahren für Bauteile

Dieses Dokument legt Anforderungen fest und beschreibt Prüfverfahren für Bauteile für Aerosol-Löschanlagen,
die ausschließlich kondensierte Aerosole verwenden.
Dieses Dokument ist nicht als Zulassung der hier aufgeführten Löschmittel durch die zuständigen Stellen
vorgesehen, da andere Löschmittel ebenso zulässig sein können.
Dieses Dokument behandelt keine Dispersions-Aerosole.

Installations fixes de lutte contre l'incendie - Systemes d'extinction a aérosol - Partie 1 : Exigences et méthodes d'essais pour les éléments constitutifs

Le présent document spécifie les exigences et décrit les méthodes d'essai relatives aux composants
d'extinction des aérosols concentrés et ne couvre que les aérosols concentrés.
Le présent document n'est pas destinée a indiquer l'approbation des agents extincteurs énumérés ici,
par les autorités compétentes, car d'autres agents extincteurs peuvent etre également acceptables.
Le présent document ne couvre pas les aérosols dispersés.

Vgrajeni gasilni sistemi - Sistemi za gašenje s kondenziranim aerosolom - 1. del: Zahteve in preskusne metode za sestavne dele

General Information

Status
Withdrawn
Publication Date
24-Feb-2009
Withdrawal Date
28-May-2019
Technical Committee
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
28-May-2019
Due Date
20-Jun-2019
Completion Date
29-May-2019

Relations

Buy Standard

Technical report
TP CEN/TR 15276-1:2009
English language
47 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST-TP CEN/TR 15276-1:2009
01-april-2009
Vgrajeni gasilni sistemi - Sistemi za gašenje s kondenziranim aerosolom - 1. del:
Zahteve in preskusne metode za sestavne dele
Fixed firefighting systems - Condensed aerosol extinguishing systems - Part 1:
Requirements and test methods for components
Ortsfeste Brandbekämpfungsanlagen - Löschanlagen für kondensierte Aerosole - Teil 1:
Anforderungen und Prüfverfahren für Bauteile
Installations fixes de lutte contre l'incendie - Systemes d'extinction a aérosol - Partie 1 :
Exigences et méthodes d'essais pour les éléments constitutifs
Ta slovenski standard je istoveten z: CEN/TR 15276-1:2009
ICS:
13.220.10 Gašenje požara Fire-fighting
SIST-TP CEN/TR 15276-1:2009 en,fr
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST-TP CEN/TR 15276-1:2009

---------------------- Page: 2 ----------------------

SIST-TP CEN/TR 15276-1:2009
TECHNICAL REPORT
CEN/TR 15276-1
RAPPORT TECHNIQUE
TECHNISCHER BERICHT
January 2009
ICS 13.220.20

English Version
Fixed firefighting systems - Condensed aerosol extinguishing
systems - Part 1: Requirements and test methods for
components
Installations fixes de lutte contre l'incendie - Systèmes Ortsfeste Brandbekämpfungsanlagen - Löschanlagen für
d'extinction à aérosol - Partie 1 : Exigences et méthodes kondensierte Aerosole - Teil 1: Anforderungen und
d'essais pour les éléments constitutifs Prüfverfahren für Bauteile
This Technical Report was approved by CEN on 9 September 2008. It has been drawn up by the Technical Committee CEN/TC 191.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,
France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,
Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: rue de Stassart, 36  B-1050 Brussels
© 2009 CEN All rights of exploitation in any form and by any means reserved Ref. No. CEN/TR 15276-1:2009: E
worldwide for CEN national Members.

---------------------- Page: 3 ----------------------

SIST-TP CEN/TR 15276-1:2009
CEN/TR 15276-1:2009 (E)
Contents Page
Foreword .4
Introduction .5
1 Scope .6
2 Normative references .6
3 Terms and definitions .7
4 Component requirements .9
4.1 Condensed aerosol generator .9
4.2 Solid aerosol-forming compound .9
4.3 Cooling mechanism .9
4.4 Ignition device .9
4.4.1 General .9
4.4.2 Electrical ignition device .9
4.4.3 Thermal ignition device .9
4.4.4 Other methods of ignition device.9
4.5 End plate and housing . 10
4.6 Extinguishants . 10
5 Condensed aerosol generators requirements . 10
5.1 General . 10
5.2 Extinguishing factor . 10
5.3 Agent distribution . 10
5.4 Discharge time . 10
5.5 Ambient temperature and humidity operation ranges . 10
5.6 Service life . 10
5.7 Shelf life and storage conditions . 11
5.8 Corrosion . 11
5.9 Vibration . 11
5.10 Mechanical shock . 11
5.11 Discharge temperature . 11
5.11.1 General . 11
5.11.2 Casing temperature . 11
5.11.3 Aerosol flow temperature . 11
5.12 Ignition device . 11
5.12.1 General . 11
5.12.2 Electrical ignition device . 11
5.12.3 Thermal ignition device . 12
5.13 Function reliability . 12
5.14 Open fire conditions . 12
5.15 Accessories . 12
5.16 Documentation . 12
6 Marking . 12
7 Test methods . 13
7.1 Conditions . 13
7.2 Samples . 13
7.3 Conformity . 14
7.4 Extinguishing factor determination . 14
7.5 Coverage determination . 14
7.6 Discharge time test . 14
7.7 Temperature and humidity operation range tests . 15
2

---------------------- Page: 4 ----------------------

SIST-TP CEN/TR 15276-1:2009
CEN/TR 15276-1:2009 (E)
7.7.1 Object of the test . 15
7.7.2 Test procedure . 15
7.7.3 Low temperature Test . 15
7.8 Accelerated ageing test . 15
7.8.1 Test time . 15
7.8.2 Test procedure . 16
7.9 Corrosion test . 16
7.10 Stress corrosion test. 17
7.11 Vibration test . 17
7.12 Impact test . 18
7.12.1 Test procedure . 18
7.12.2 Test apparatus . 18
7.13 Drop test . 20
7.13.1 Impact surface . 20
7.13.2 Procedure . 20
7.13.3 Requirements . 20
7.14 Casing and aerosol flow temperatures test . 20
7.14.1 Casing temperature test . 20
7.14.2 Aerosol flow temperature test . 20
7.15 Ignition performance test . 20
7.16 Function test . 20
7.16.1 Discharge time . 21
7.16.2 Aerosol flow temperatures . 21
7.16.3 Test procedure . 21
7.16.4 Casing temperature test . 21
7.16.5 Discharged mass . 21
7.16.6 Explosive atmosphere actuation test . 21
7.16.7 Requirements . 22
7.17 Heat exposure test . 22
7.17.1 Object of the test . 22
7.17.2 Test procedure . 22
7.17.3 Requirements . 22
7.18 Explosive atmosphere test . 22
7.18.1 Object of the test. . 22
7.18.2 Test procedure . 23
7.18.3 Requirements . 23
Annex A (normative) Extinguishing factor/coverage test procedure . 24
Bibliography . 47

3

---------------------- Page: 5 ----------------------

SIST-TP CEN/TR 15276-1:2009
CEN/TR 15276-1:2009 (E)
Foreword
This document (CEN/TR 15276-1:2009) has been prepared by Technical Committee CEN/TC 191 “Fixed
firefighting systems”, the secretariat of which is held by BSI.
This document has the general title Fixed fire-fighting systems – Condensed aerosol extinguishing systems
and will consist of the following parts:
 Part 1: Requirements and test methods for components;
 Part 2: Design, installation and maintenance.
4

---------------------- Page: 6 ----------------------

SIST-TP CEN/TR 15276-1:2009
CEN/TR 15276-1:2009 (E)

Introduction
It has been assumed in the preparation of this document that the execution of its provisions is entrusted to
appropriately qualified and experienced people in the specification, design, installation, testing, approval,
inspection, operation and maintenance of systems and equipment, for whose guidance it has been prepared,
and who can be expected to exercise a duty of care to avoid unnecessary release of extinguishant.
Product certification: Users of this document are advised to consider the desirability of independent
certification of product conformity with this document based on testing and continuing surveillance, which may
be coupled with assessment of manufacturer quality systems against EN ISO 9001.
Fire-fighting systems covered in this document are designed to provide a supply of fixed condensed aerosol
extinguishing medium to extinguish fire.
The requirements of this document are made in the light of the best technical data known to the working group
at the time of writing but, since a wide field is covered, it has been impracticable to consider every possible
factor or circumstance that might affect implementation of the requirements.
It is important that the fire protection of a building or plant be considered as a whole. Aerosol extinguishant
systems form only a part, though an important part, of the available facilities, but it should not be assumed that
their adoption necessarily removes the need to consider supplementary measures, such as the provision of
portable fire extinguishers or other mobile appliances for first aid or emergency use, or to deal with special
hazards.
Aerosol extinguishants have been recognized as effective media for the extinction of Class A fires (solid
surface burning fires) and Class B and Class C fires according to EN 2, but it should not be forgotten, in the
planning of comprehensive schemes, that there may be hazards for which these mediums are not suitable, or
that in certain circumstances or situations there may be dangers in their use requiring special precautions.
Advice on these matters can be obtained from the appropriate manufacturer of the aerosol generators or the
extinguishing system. Information may also be sought from the appropriate fire authority, the health and safety
authorities and insurers. In addition, reference should be made as necessary to other national standards and
statutory regulations.
It is essential that fire-fighting equipment be carefully maintained to ensure instant readiness when required.
Routine maintenance is liable to be overlooked or given insufficient attention by the owner of the system. It is,
however, neglected at peril to the lives of occupants of the premises and at the risk of crippling financial loss.
The importance of maintenance cannot be too highly emphasised.
Condensed aerosol may contain traces of toxic substances like those produced by a fire, and will obscure
vision like smoke from fire.
5

---------------------- Page: 7 ----------------------

SIST-TP CEN/TR 15276-1:2009
CEN/TR 15276-1:2009 (E)

1 Scope
This document specifies requirements, describes test methods for condensed aerosol extinguishing
components and covers solely condensed aerosols.
This document is not intended to indicate approval of the extinguishants listed herein by the appropriate
authorities, as other extinguishants may be equally acceptable.
This document is intended as a standard covering solely condensed aerosol.
The condensed aerosol generator typically consists of the following main components:
a) solid aerosol-forming compound;
b) cooling mechanism;
c) ignition device(s);
d) end plate discharge outlet(s);
e) housing;
f) mounting bracket.
This document does not cover dispersed aerosols.
This document requires, as a precaution, that the room is evacuated and sealed off whenever a generator is
activated. Precautions include evacuation of the proximity area, criteria for re-entering and other safeguards
as stated in Clause 5 of CEN/TR 15276-2:2009.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
EN 316, Wood fibreboards – Definition, classification and symbols
EN 622 (all parts), Fibreboards – Specifications
EN 60068-2-6, Environmental testing – Part 2-6: Tests – Test Fc: Vibration (sinusoidal) (IEC 60068-2-6:2007)
EN 60068-2-30, Environmental testing – Part 2-30: Tests – Test Db: Damp Heat, cyclic (12 h + 12 h cycle)
(IEC 60068-2-30:2005)
ISO 209, Aluminium and aluminium alloys – Chemical composition
ISO 5660-1, Reaction-to-fire tests – Heat release, smoke production and mass loss rate – Part 1: Heat
release rate (cone calorimeter method)
6

---------------------- Page: 8 ----------------------

SIST-TP CEN/TR 15276-1:2009
CEN/TR 15276-1:2009 (E)
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
3.1
authority
organisation, office or individual responsible for approving equipment, installations or procedures in
determining acceptability
NOTE The authority may base acceptance on conformity to the appropriate standards.
3.2
clearance

3.2.1
electrical clearance
unobstructed air distance between extinguishing system equipment and unenclosed or uninsulated live
electrical components not at ground potential
3.2.2
thermal clearance
air distance between a condensed aerosol generator and any structure or components sensitive to the
temperature developed by the generator
3.3
condensed aerosol
extinguishing medium consisting of finely divided solid particles and gaseous matter, these being generated
by a combustion process of a solid aerosol-forming compound
3.4
condensed aerosol generator
non-pressurised device which, when activated, generates an aerosol. It includes the mounting brackets
3.5
design factor
extinguishing factor multiplied by the safety factor, required for system design purposes
NOTE 1 The design factor is expressed in grams per cubic metre.
NOTE 2 Extinguishing factor and design factor have been introduced as an alternative to extinguishing concentration
and design concentration respectively as concentration of the actual aerosol cannot be measured or even assessed in
some cases (the discharged medium, apart from the condensed aerosol, may contain products of the thermal
decomposition of a chemical coolant).
3.6
discharge time
time from the generator activation to the end of its discharge
3.7
extinguishing application density

minimum mass of a specific aerosol-forming compound per cubic metre of enclosure volume required to
extinguish fire involving a specific fuel under defined experimental conditions, excluding any safety factors
NOTE The extinguishing factor is expressed in grams per cubic metre.
3.8
family
group of generators with same solid compound, same kind of cooling device, same kind of discharge outlet,
same ignition device, same layout and same internal/external architecture
7

---------------------- Page: 9 ----------------------

SIST-TP CEN/TR 15276-1:2009
CEN/TR 15276-1:2009 (E)
3.9
ignition device
any device which is able to ignite the solid aerosol-forming compound
3.10
listing authority
recognized fire protection testing and approval body (notified laboratory)
3.11
maintenance
thorough check to give maximum assurance that the extinguishing system will operate as intended
NOTE It includes a thorough examination and any necessary repair or replacement of system components.
3.12
manufacturer
legal person that is responsible for the design, manufacturing, packaging and quality assurance of a device
before it is placed on the market
3.13
monitoring
supervision of the operating integrity of an electrical, mechanical, pneumatic or hydraulic control feature of a
system
3.14
protected volume
volume enclosed by the building elements around the protected enclosure, minus the volume of any
permanent impermeable building element within the enclosure
3.15
release
physical discharge or emission of an aerosol as a consequence of the generator actuation
3.16
safety factor
multiplier of the extinguishing factor to determine the design factor
3.17
solid aerosol-forming compound
mixture of oxidant, combustible component and technical admixtures producing fire extinguishing aerosol
upon ignition
3.18
supplier
legal person that is responsible for the product and is able to ensure that its quality is ensured
3.19
thermal ignition device
device which automatically operates at a rated temperature and is arranged for the ignition of the solid
aerosol-forming compound
3.20
test house
establishment having all relevant test equipment to carry out the required tests
8

---------------------- Page: 10 ----------------------

SIST-TP CEN/TR 15276-1:2009
CEN/TR 15276-1:2009 (E)
4 Component requirements
4.1 Condensed aerosol generator
The condensed aerosol generator typically consists of the following main components:
a) solid aerosol-forming compound;
b) cooling mechanism;
c) ignition device(s);
d) end plate discharge outlet(s);
e) housing;
f) mounting bracket.
The generator is a non-pressurised canister, because aerosol is generated and distributed by the combustion
process of the solid aerosol-forming compound.
4.2 Solid aerosol-forming compound
Upon actuation of the condensed aerosol generator, the solid aerosol-forming compound shall undergo the
combustion reaction producing a fire extinguishing aerosol.
4.3 Cooling mechanism
The cooling mechanism shall provide an adequate cooling of the hot aerosol prior to its discharge into the
enclosure.
4.4 Ignition device
4.4.1 General
The ignition device is arranged to initiate the aerosol-forming compound.
If the ignition device is a complex device incorporating several components, all such components shall be
specified by the manufacturer.
4.4.2 Electrical ignition device
The electrical ignition device shall be capable of operating via an electrical input and arranged to initiate the
aerosol-forming compound.
4.4.3 Thermal ignition device
The thermal ignition device shall be capable of operating at a rated temperature and arranged to initiate the
aerosol-forming compound.
4.4.4 Other methods of ignition device
Methods capable to ignite the aerosol-forming compound, other than 4.4.2 and 4.4.3, shall be specified.
9

---------------------- Page: 11 ----------------------

SIST-TP CEN/TR 15276-1:2009
CEN/TR 15276-1:2009 (E)
4.5 End plate and housing
The outer case and all parts inside the generator shall be made of corrosion-resistant material or shall be
suitably treated to resist corrosion. The manufacturer shall ensure that the materials of construction are also
compatible with the solid aerosol-forming compound and the cooling device so that corrosion or chemical
action does not occur.
Materials for non-metallic components that are exposed to ultraviolet light shall be UV-stabilised.
4.6 Extinguishants
The extinguishants referred to in this document are electrically non-conductive media.
5 Condensed aerosol generators requirements
5.1 General
The test samples shall conform to the technical description (drawings, parts list, description of function,
operating instructions) as stated by the manufacturer (see 5.16 and 7.3).
The manufacturer shall specify the minimum distance from the generator outlet to the first obstacle.
The manufacturer shall specify the minimum and maximum mass of aerosol compound discharged from the
generator
5.2 Extinguishing factor
The extinguishing factor for specific fuels under different classes of fires shall be determined by test using the
fire test protocol described in Annex A.
5.3 Agent distribution
The maximum area coverage and the related maximum and minimum height of the protected enclosure for
each aerosol generator unit size shall be determined by test using the fire test protocol described in 7.5.
5.4 Discharge time
The discharge time required to achieve 95 % of the minimum design application density shall be specified by
the manufacturer and shall not exceed 90 s when tested in accordance with 7.6.
5.5 Ambient temperature and humidity operation ranges
Condensed aerosol generators shall operate at ambient temperatures as specified by the manufacturer and
as a minimum requirement from – 20 °C to + 50 °C.
Condensed aerosol generators shall operate at ambient humidity up to 95 %.
These operation ranges shall be verified by the temperature and humidity operation range tests as described
in 7.7.
5.6 Service life
The service life of condensed aerosol generator under specific conditions, as described in 5.5, shall be
specified by the manufacturer and as a minimum requirement shall not be less than 5 years.
10

---------------------- Page: 12 ----------------------

SIST-TP CEN/TR 15276-1:2009
CEN/TR 15276-1:2009 (E)
The specified service life shall be verified by test using the accelerated ageing test as described in 7.8.
5.7 Shelf life and storage conditions
The shelf life and storage conditions shall be specified by the manufacturer.
5.8 Corrosion
The aerosol generator shall operate according to 7.16 and shall show no sign of
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.