SIST EN 50136-3:2014/A1:2021
(Amendment)Alarm systems - Alarm transmission systems and equipment - Part 3: Requirements for Receiving Centre Transceiver (RCT)
Alarm systems - Alarm transmission systems and equipment - Part 3: Requirements for Receiving Centre Transceiver (RCT)
This European Standard specifies the minimum equipment requirements for the performance, reliability, resilience, security and safety characteristics of the receiving centre transceiver (RCT) installed in ARC and used in alarm transmission systems. The alarm transmission system requirements and classifications are defined within EN 50136 1. Different types of alarm systems may in addition to alarm messages also send other types of messages, e.g. fault messages and status messages. These messages are also considered to be alarm messages. The term alarm message is used in this broad sense throughout the document. Where application specific standards exist, the RCT should comply with relevant standards called up by that application. The RCT can be either an integrated element of any receiving/annunciation equipment, or a stand-alone device. In either case, the requirements of this European Standard should apply. The function of the RCT is to monitor the ATPs, receive alarm messages, forward alarm messages to one or more AEs and send acknowledgements to the SPTs. Management of the transmission network is not in the scope of this European Standard.
Alarmanlagen - Alarmübertragungsanlagen und -einrichtungen - Teil 3: Anforderungen an Übertragungszentralen (ÜZ)
Systèmes d'alarme - Systèmes et équipements de transmission d'alarme - Partie 3: Exigences pour les transmetteurs du centre de réception (RCT)
La présente Norme Européenne spécifie les exigences matérielles minimales relatives au fonctionnement, à la fiabilité, à la résilience, à la sécurité et à la sûreté des transmetteurs du centre de réception (RCT) installés dans l'ARC et utilisés dans les systèmes de transmission d’alarme. Les exigences et les classifications des systèmes de transmission d’alarme sont définies dans la EN 50136-1. Différents types de systèmes d’alarme peuvent, outre des messages d’alarme, envoyer d’autres types de messages, par exemple des messages de défaut et des messages d’état. Ces messages sont également considérés comme des messages d'alarme. Le terme message d'alarme est utilisé dans ce sens large dans le document. Si des normes spécifiques à l'application existent, il convient que le RCT satisfasse aux normes correspondantes mentionnées par cette application. Le RCT peut être soit un élément intégré d'équipement de réception/d'annonce, soit un dispositif autonome. Dans les deux cas, il convient que les exigences de la présente Norme Européenne s'appliquent. Le RCT a pour fonction de surveiller les ATP, de recevoir les messages d'alarme, de transmettre les messages d'alarme vers un ou plusieurs AE et d'envoyer des accusés de réception aux SPT. La gestion du réseau de transmission ne fait pas partie du domaine d’application de la présente Norme Européenne.
Alarmni sistemi - Sistemi in oprema za prenos alarma - 3. del: Zahteve za oddajnik sprejemnega centra (RCT) - Dopolnilo A1
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
SIST EN 50136-3:2014/A1:2021
01-julij-2021
Alarmni sistemi - Sistemi in oprema za prenos alarma - 3. del: Zahteve za oddajnik
sprejemnega centra (RCT) - Dopolnilo A1
Alarm systems - Alarm transmission systems and equipment - Part 3: Requirements for
Receiving Centre Transceiver (RCT)
Alarmanlagen - Alarmübertragungsanlagen und -einrichtungen - Teil 3: Anforderungen
an Übertragungszentralen (ÜZ)
Systèmes d'alarme - Systèmes et équipements de transmission d'alarme - Partie 3:
Exigences pour les transmetteurs du centre de réception (RCT)
Ta slovenski standard je istoveten z: EN 50136-3:2013/A1:2021
ICS:
13.320 Alarmni in opozorilni sistemi Alarm and warning systems
SIST EN 50136-3:2014/A1:2021 en,fr
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
SIST EN 50136-3:2014/A1:2021
---------------------- Page: 2 ----------------------
SIST EN 50136-3:2014/A1:2021
EUROPEAN STANDARD EN 50136-3:2013/A1
NORME EUROPÉENNE
EUROPÄISCHE NORM
May 2021
ICS 13.320
English Version
Alarm systems - Alarm transmission systems and equipment -
Part 3: Requirements for Receiving Centre Transceiver (RCT)
Systèmes d'alarme - Systèmes et équipements de Alarmanlagen - Alarmübertragungsanlagen und -
transmission d'alarme - Partie 3: Exigences pour les einrichtungen - Teil 3: Anforderungen an
transmetteurs du centre de réception (RCT) Übertragungszentralen (ÜZ)
This amendment A1 modifies the European Standard EN 50136-3:2013; it was approved by CENELEC on 2021-04-12. CENELEC
members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this amendment the
status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This amendment exists in three official versions (English, French, German). A version in any other language made by translation under the
responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as
the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the
Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2021 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN 50136-3:2013/A1:2021 E
---------------------- Page: 3 ----------------------
SIST EN 50136-3:2014/A1:2021
EN 50136-3:2013/A1:2021
Contents
1 Modification to Clause 2, “Normative references” . 4
2 Modification to Clause 4, “Object” . 4
3 Modifications to Clause 6, “Functional requirement” . 4
4 Modifications to Clause 7, “Tests” . 5
2
---------------------- Page: 4 ----------------------
SIST EN 50136-3:2014/A1:2021
EN 50136-3:2013/A1:2021
European foreword
This document (EN 50136-3:2013/A1:2021) has been prepared by CLC/TC 79, “Alarm systems”.
The following dates are fixed:
• latest date by which this document has (dop) 2022-04-12
to be implemented at national level by
publication of an identical national
standard or by endorsement
• latest date by which the national (dow) 2024-04-12
standards conflicting with this document
have to be withdrawn
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC shall not be held responsible for identifying any or all such patent rights.
3
---------------------- Page: 5 ----------------------
SIST EN 50136-3:2014/A1:2021
EN 50136-3:2013/A1:2021
1 Modification to Clause 2, “Normative references”
Replace the normative reference EN 50136-1:2012 as follows:
1
"EN 50136-1:2012 , Alarm systems - Alarm transmission systems and equipment - Part 1: General
requirements for alarm transmission systems"
2 Modification to Clause 4, “Object”
Replace the existing text with the following:
“This document specifies the minimum equipment requirements for the performance, reliability,
resilience, security and safety characteristics of the Receiving Centre Transceiver (RCT) installed in
alarm receiving centres and/or in a secure location, and to define parameters that shall be tested to
ensure its compatibility with ATS categories.”
3 Modifications to Clause 6, “Functional requirement”
In 6.2, replace the 7th paragraph with:
“Where it is possible to attempt to gain access more than 3 times in a 60-s period the RCT shall have
the ability to delay repeated attempts. After the third attempt, each further attempt shall be prevented
for a minimum of 90 s. This should be recorded in the RCT and a notification should be sent to the
ATSP.
This kind of behaviour should be considered as an attempted hacking.”
In 6.5, replace the 1st paragraph with:
“For compliance to the relevant standards of the application, the RCT shall monitor ATP and ATS.
1
Failures shall be reported to the AMS as defined in EN 50136-1:2012 , 6.6, Table 4 and made available
to the ATSP.”
Replace the title of 6.6 from “Interface(s) to the AE(s)” to “Interface(s) to the AMS(s)”.
In 6.6, replace the 2nd paragraph with:
“The manufacturer shall state in their product documentation the specifications of the interface(s) to the
I (AMS) and how the fault signal is presented and logged.”
RCT
In 6.7, replace the entire subclause with the following:
“The RCT shall have a means to signal faults when any of the following faults occur:
— transmission link failure between RCT (or RCT-A for hosted solution) and AMS (I );
RCT
It may not be possible to signal this failure to the AMS over a failed link.
— in case of hosted solution, transmission link failure between RCT-H and RCT-A;
— transmission network interfaces between RCT (or for hosted solution RCT-H) and SPT (for example
encryption issue);
— internal RCT system failure including time deviation after the commissioning.
The manufacturer shall specify in the RCT documentation how these faults are signalled to the AMS
and to the ATSP. The manufacturer shall describe how this can be tested.”
1
As impacted by EN 50136-1:2012/A1:2018.
4
---------------------- Page: 6 ----------------------
SIST EN 50136-3:2014/A1:2021
EN 50136-3:2013/A1:2021
In 6.8, replace the 3rd paragraph:
“The event log may be stored outside of the RCT.” with: “The event log archives may be stored outside
of the RCT.”
4 Modifications to Clause 7, “Tests”
For every subclauses in 7.3, replace all the references of “AE” to “AMS”.
In 7.3.1, replace the 4th paragraph:
“All AE interfaces shall be tested.” with: “All AMS interfaces shall be tested.”
In 7.3.1, replace the entire Table 3 with the following:
“Table 3 — Summary of functional tests
Section Requirement to test Test/validation objective Validate or test
reference
6.1 Processing of alarm signals Demonstrate the ability of the Test (7.3.9)
RCT to receive, process and
forward a signal or message
from the ATS.
6.2 Access levels Demonstrate that all access Test (7.3.2)
levels exist.
6.3 Upload and download of Demonstrate that the RCT will Test (7.3.3)
software recover after an unsuccessful
software upload/download.
6.4 Storage of parameters and Demonstrate that the RCT will Test (7.3.4)
customer specific data not lose any parameters or
customer specific data after a
reset or power cycle.
6.5a Notification of an ATS failure Demonstrate that the RCT Test (7.3.5)
for a single path ATS signals an ATS failure to the
AMS as defined in
1
EN 50136-1:2012 , Table 4.
6.5b Notification of an ATS failure Demonstrate that the RCT Test (7.3.6)
for a dual path ATS signals an ATS failure to the
AMS as defined in
1
EN 50136-1:2012 , Table 4.
6.6 Interface(s) to the AMS(s) Demonstrate that the Test (7.3.7)
interface(s) to the AMS(s) are
monitored.
6.7 Fault signalling Demonstrate that faults are Test (7.3.8)
signalled according to the
manufacturer RCT
documentation.
6.8a Event recording Demonstrate that all Test (7.3.10)
mandatory events are
recorded as required in
Table 2.
6.8b Clock resolution and Demonstrate that the Test (7.3.11)
synchronisation accuracy of the timestamps as
attached to events in the log
complies with the
requirements of 6.9.
5
---------------------- Page: 7 ----------------------
SIST EN 50136-3:2014/A1:2021
EN 50136-3:2013/A1:2021
Section Requirement to test Test/validation objective Validate or test
reference
6.8c Endurance of the log Verify that the manu
...
SLOVENSKI STANDARD
SIST EN 50136-3:2014/oprA1:2020
01-maj-2020
Alarmni sistemi - Sistemi in oprema za prenos alarma - 3. del: Zahteve za oddajnik
sprejemnega centra (RCT) - Dopolnilo A1
Alarm systems - Alarm transmission systems and equipment - Part 3: Requirements for
Receiving Centre Transceiver (RCT)
Alarmanlagen - Alarmübertragungsanlagen und -einrichtungen - Teil 3: Anforderungen
an Übertragungszentralen (ÜZ)
Systèmes d'alarme - Systèmes et équipements de transmission d'alarme - Partie 3:
Exigences pour les transmetteurs du centre de réception (RCT)
Ta slovenski standard je istoveten z: EN 50136-3:2013/prA1
ICS:
13.320 Alarmni in opozorilni sistemi Alarm and warning systems
SIST EN 50136-3:2014/oprA1:2020 en,fr
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
SIST EN 50136-3:2014/oprA1:2020
---------------------- Page: 2 ----------------------
SIST EN 50136-3:2014/oprA1:2020
EUROPEAN STANDARD DRAFT
EN 50136-3:2013
NORME EUROPÉENNE
EUROPÄISCHE NORM
prA1
March 2020
ICS 13.320
English Version
Alarm systems - Alarm transmission systems and equipment -
Part 3: Requirements for Receiving Centre Transceiver (RCT)
Systèmes d'alarme - Systèmes et équipements de Alarmanlagen - Alarmübertragungsanlagen und -
transmission d'alarme - Partie 3: Exigences pour les einrichtungen - Teil 3: Anforderungen an
transmetteurs du centre de réception (RCT) Übertragungszentralen (ÜZ)
This draft amendment prA1, if approved, will modify the European Standard EN 50136-3:2013; it is submitted to CENELEC members for
enquiry.
Deadline for CENELEC: 2020-05-29.
It has been drawn up by CLC/TC 79.
If this draft becomes an amendment, CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which
stipulate the conditions for giving this amendment the status of a national standard without any alteration.
This draft amendment was established by CENELEC in three official versions (English, French, German).
A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to
the CEN-CENELEC Management Centre has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the
Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.
Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are aware and to
provide supporting documentation.
Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without notice and
shall not be referred to as a European Standard.
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2020 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Project: 68892 Ref. No. EN 50136-3:2013/prA1 E
---------------------- Page: 3 ----------------------
SIST EN 50136-3:2014/oprA1:2020
EN 50136-3:2013/prA1:2020
15 Contents
16 European foreword .3
17 6 Modification to Clause 4, Object .4
18 7 Modifications to Clause 6, Functional requirement .4
19 8 Modifications to Clause 7, Tests .5
20
2
---------------------- Page: 4 ----------------------
SIST EN 50136-3:2014/oprA1:2020
EN 50136-3:2013/prA1:2020
21 European foreword
22 This document (EN 50136-3:2013/prA1:2020) has been prepared by CLC/TC 79, “Alarm systems”.
23 This document is currently submitted to the Enquiry.
24 Amendment 1 to this standard improves the additional requirements for so-called hosted RCT alarm
25 transmission systems and makes miscellaneous changes to correct errors and to reflect better the
26 current state of the art.
27 The following dates are proposed:
— latest date by which the existence of (doa) dor + 6 months
this document has to be announced
at national level
— latest date by which this document has to be (dop) dor + 12 months
implemented at national level by publication of
an identical national standard or by
endorsement
— latest date by which the national standards (dow) dor + 36 months
conflicting with this document have to (to be confirmed or
be withdrawn modified when voting)
28
3
---------------------- Page: 5 ----------------------
SIST EN 50136-3:2014/oprA1:2020
EN 50136-3:2013/prA1:2020
29 1 Modification to Clause 4, Object
30 Replace the existing text with the following:
31 “This European standard specifies the minimum equipment requirements for the performance,
32 reliability, resilience, security and safety characteristics of the Receiving Centre Transceiver (RCT)
33 installed in alarm receiving centres and/or in a secure location, and to define parameters that shall be
34 tested to ensure its compatibility with ATS categories.”.
35 2 Modifications to Clause 6, Functional requirement
36 6.2 Access levels
37 Replace the 7th paragraph of 6.2 with: “
38 Where it is possible to attempt to gain access more than 3 times in a 60-s period the RCT shall have
39 the ability to delay repeated attempts. After the third attempt, each further attempt shall be prevented
40 for a minimum of 90 s. This should be recorded in the RCT and an alarm should be sent to the ATSP.
41 This kind of behaviour should be considered as an attempted hacking.”.
42
43 6.5 Monitoring and notification of failure of the ATP and ATS
44 Replace the 1st paragraph of 6.5 with: “
45 For compliance to the relevant standards of the application, the RCT shall monitor ATP and ATS.
46 Failures shall be reported to the AMS as defined in EN 50136-1:2012/A1:2018, 6.6, Table 4 and made
47 available to the ATSP.”.
48
49 6.6 Interface(s) to the AE(s)
50 Replace the title and the 2nd paragraph 6.6 with: “
51 “6.6 Interface(s) to the AMS(s)”
52 and
53 “The manufacturer shall state in their product documentation the specifications of the interface(s) to
54 the I (AMS) and how the fault signal is presented and logged.”.
RCT
55
56 6.7 Fault signalling
57 Replace the paragraphs of 6.7 with: “
58 The RCT shall have a means to signal faults when any of the following faults occur:
59 - transmission link failure between RCT (or RCT-A for hosted solution) and AMS (I );
RCT
60 It may not be possible to signal this failure to the AMS over a failed link.
61 - in case of hosted solution, transmission link failure between RCT-H and RCT-A;
62 - transmission network interfaces between RCT (or for hosted solution RCT-H) and SPT (for
63 example encryption issue);
64 - internal RCT system failure including time deviation after the commissioning.
65 The manufacturer shall specify in the RCT documentation how these faults are signalled to the AMS
66 and to the ATSP. The manufacturer shall describe how this can be tested.”.
67
4
---------------------- Page: 6 ----------------------
SIST EN 50136-3:2014/oprA1:2020
EN 50136-3:2013/prA1:2020
68 6.8 Event recording
69 Replace the 3rd paragraph:
70 “The event log may be stored outside of the RCT.”
71 with:
72 “The event log archives may be stored outside of the RCT.”.
73 3 Modifications to Clause 7, Tests
74 7.3 Functional tests
75 For all the subclauses in 7.3 all the references to “AE” have to be replaced with “AMS”.
76
77 7.3.1 General
78 Replace:
79 “All AE interfaces shall be tested.”
80 with:
81 “All AMS interfaces shall be tested.”.
82
83 Replace Table 3 with this new table: “
Section Requirement to test Test/validation objective Validate or test
reference
6.1 Processing of alarm signals Demonstrate the ability of Test (7.3.9)
the RCT to receive,
process and forward a
signal or message from
the ATS.
6.2 Access levels Demonstrate that all Test (7.3.2)
access levels exist.
6.3 Upload and download of Demonstrate that the RCT Test (7.3.3)
software will recover after an
unsuccessful software
upload/download.
6.4 Storage of parameters and Demonstrate that the RCT Test (7.3.4)
customer specific data will not lose any
parameters or customer
specific data after a reset
or power cycle.
6.5a Notification of an ATS failure Demonstrate that the RCT Test (7.3.5)
for a single path ATS signals an ATS failure to
the AMS as defined in
EN 50136-1:2012,
Table 4.
6.5b Notification of an ATS failure Demonstrate that the RCT Test (7.3.6)
for a dual path ATS signals an ATS failure to
the AMS as defined in
EN 50136-1:2012,
Table 4.
6.6 Interface(s) to the AMS(s) Demonstrate that the Test (7.3.7)
interface(s) to the AMS(s)
5
---------------------- Page: 7 ----------------------
SIST EN 50136-3:2014/oprA1:2020
EN 50136-3:2013/prA1:2020
Section Requirement to test Test/validation objective Validate or test
reference
are monitored.
6.7 Fault signalling Demonstrate that faults Test (7.3.8)
are signalled according to
the manufacturer RCT
documentation.
6.8a Event recording Demonstrate that all Test (7.3.10)
mandatory events are
recorded as required in
Table 2.
6.8b Clock resolution and Demonstrate that the Test (7.3.11)
synchronisation accuracy of the
timestamps as attached to
events in the log complies
with the requirements of
6.9.
6.8c Endurance of the log Verify that the Validate (7.3.12)
manufacturer
documentation specifies
how 3-year endurance
...