Liquid-applied water impermeable products for use beneath ceramic tiling bonded with adhesives - Requirements, test methods, evaluation of conformity, classification and designation

This European Standard applies to all liquid-applied water impermeable products, based on polymer modified cementitious mortars, dispersions and reaction resin coatings, used beneath ceramic tiling, for external tile installations on walls and floors and in swimming pools.
This European Standard gives the terminology concerning the products and specifies the test methods and the values of performance requirements for liquid-applied water impermeable products associated with tile adhesives.
This European Standard specifies the evaluation of conformity and the classification and designation of liquid-applied water impermeable products beneath ceramic tiling.
This European Standard does not contain recommendations for the design and installation of ceramic tiles and grouts in combination with water impermeable products.
NOTE 1   Liquid-applied water impermeable products may also be used beneath other types of tiles (natural and agglomerated stones, etc.), where they do not adversely affect these materials.
NOTE 2   The user of this European Standard should be familiar with normal laboratory practice. This European Standard does not purport to address all the safety problems associated with its use. It is the responsibility of the user to establish appropriate health and safety practices and to ensure compliance with any European and national regulatory conditions.

Flüssig zu verarbeitende wasserundurchlässige Produkte im Verbund mit keramischen Fliesen und Plattenbelägen - Anforderungen, Prüfverfahren, Konformitätsbewertung, Klassifizierung und Bezeichnung

Diese Europäische Norm gilt für alle flüssig zu verarbeitenden wasserundurchlässigen Produkte, die aus Schichten auf der Basis von polymermodifiziertem Zementmörtel, Dispersions- und Reaktionsharzen bestehen und unter keramischen Fliesen und Platten für Wand und Boden und in Schwimmbecken im Außenbereich verwendet werden. Diese Europäische Norm enthält die Terminologie für die Produkte und legt die Prüfverfahren und die Werte für die Leistungsanforderungen an flüssig zu verarbeitende wasserundurchlässige Produkte in Verbindung mit Fliesenkleber fest. Diese Europäische Norm legt die Konformitätsbewertung sowie die Klassifizierung und Bezeichnung von flüssig zu verarbeitenden wasserundurchlässigen Produkten, die unter keramischen Fliesen und Platten verwendet werden, fest. Diese Europäische Norm enthält keine Empfehlungen für die Anwendung und Verarbeitung der Keramikfliesen und ihre Verlegung in Verbindung mit wasserundurchlässigen Produkten. ANMERKUNG 1 Flüssig zu verarbeitende wasserundurchlässige Produkte dürfen auch unter anderen Fliesenarten (Natur- und Kunststeinfliesen usw.) angewendet werden, sofern sie keinen nachteiligen Einfluss auf diese Materialien ausüben. ANMERKUNG 2 Die Anwender dieser Europäischen Norm sollten mit der üblichen Laborpraxis vertraut sein. Diese Europäische Norm berücksichtigt nicht alle bei ihrer Anwendung möglicherweise auftretenden Sicherheitsprobleme. Es liegt in der Verantwortung des Anwenders, geeignete Verhaltensregeln zur Sicherheit und zur Gesundheit festzulegen und deren Übereinstimmung mit den Bestimmungen aller europäischen und nationalen Regelungen sicherzustellen.

Produits d'imperméabilisation appliqués en phase liquide utilisés sous carrelage collé - Spécifications, méthodes d'essai, évaluation de la conformité, classification et désignation

La présente Norme européenne s’applique à tous les produits d’imperméabilisation à base de mortiers de ciment modifiés par des polymères, de résine réactive et de résine en dispersion appliqués en phase liquide et utilisés sous carrelage collé, pour la pose, en extérieur, des carreaux céramiques au sol et mur et dans les piscines.
La présente Norme européenne donne la terminologie concernant les produits et prescrit les méthodes d’essai ainsi que les exigences performancielles des produits d’imperméabilisation appliqués en phase liquide en association avec des colles à carrelage.
La présente Norme européenne spécifie l’évaluation de la conformité, la classification et la désignation des produits d’imperméabilisation destinés à être utilisés sous du carrelage céramique.
La présente Norme européenne ne contient pas de recommandations relatives à la conception et à la pose de carreaux céramiques ni à la réalisation de joints, en association avec les produits d’imperméabilisation.
NOTE 1   Les produits d’imperméabilisation appliqués en phase liquide peuvent également être utilisés pour la pose d’autres types de carreaux (pierres naturelles ou agglomérées, etc.), si ils sont compatibles avec ces matériaux.
NOTE 2   L’utilisateur de la présente Norme européenne doit bien connaître les pratiques courantes de laboratoire. La présente Norme européenne n’a pas pour but de traiter tous les problèmes de sécurité qui sont, le cas échéant, liés à son utilisation. Il incombe à l’utilisateur de la présente norme d’établir des pratiques appropriées en matière d’hygiène et de sécurité, et de s’assurer de la conformité à toute réglementation nationale et européenne en vigueur.

Tekoče vgrajevani za vodo neprepustni izdelki za uporabo pod keramičnimi ploščicami, lepljenimi z lepili - Zahteve, preskusne metode, ugotavljanje skladnosti, klasifikacija in označevanje

Ta evropski standard se uporablja za vse tekoče vgrajevane za vodo neprepustne izdelke na osnovi polimer-cementnih malt, disperzij in malt na osnovi smol, ki se uporabljajo pod keramičnimi ploščicami za namestitev zunanjih ploščic na zidove in tla ter v bazene. Ta evropski standard podaja terminologijo na področju izdelkov in določa preskusne metode in vrednosti zahtev glede zmogljivosti tekoče vgrajevanih za vodo neprepustnih izdelkov, povezanih z lepili za ploščice. Ta evropski standard določa vrednotenje skladnosti ter klasifikacijo in označevanje tekoče vgrajevanih za vodo neprepustnih izdelkov pod keramičnimi ploščicami. Ta evropski standard ne vključuje priporočil za načrtovanje in vgradnjo keramičnih ploščic in lepil v kombinaciji z za vodo neprepustnimi izdelki.

General Information

Status
Withdrawn
Publication Date
10-Jun-2012
Withdrawal Date
03-Apr-2017
Technical Committee
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
04-Apr-2017
Due Date
27-Apr-2017
Completion Date
04-Apr-2017

Relations

Buy Standard

Standard
EN 14891:2012
English language
33 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.PLþQLPLDYOMDQMHFlüssig zu verarbeitende wasserundurchlässige Produkte im Verbund mit keramischen Fliesen und Plattenbelägen - Anforderungen, Prüfverfahren, Konformitätsbewertung, Klassifizierung und BezeichnungProduits d'imperméabilisation appliqués en phase liquide utilisés sous carrelage collé - Spécifications, méthodes d'essai, évaluation de la conformité, classification et désignationLiquid-applied water impermeable products for use beneath ceramic tiling bonded with adhesives - Requirements, test methods, evaluation of conformity, classification and designation91.100.50Veziva. Tesnilni materialiBinders. Sealing materials91.100.23Ceramic tilesICS:Ta slovenski standard je istoveten z:EN 14891:2012SIST EN 14891:2012en,fr,de01-julij-2012SIST EN 14891:2012SLOVENSKI
STANDARDSIST EN 14891:2008/AC:2009SIST EN 14891:2008/AC:2010SIST EN 14891:2008SIST EN 14891:2008/AC:20081DGRPHãþD



SIST EN 14891:2012



EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 14891
April 2012 ICS 91.100.25; 91.100.50 Supersedes EN 14891:2007English Version
Liquid-applied water impermeable products for use beneath ceramic tiling bonded with adhesives - Requirements, test methods, evaluation of conformity, classification and designation Produits d'imperméabilisation appliqués en phase liquide utilisés sous carrelage collé - Spécifications, méthodes d'essai, évaluation de la conformité, classification et désignation
Flüssig zu verarbeitende wasserundurchlässige Produkte im Verbund mit keramischen Fliesen und Plattenbelägen - Anforderungen, Prüfverfahren, Konformitätsbewertung, Klassifizierung und Bezeichnung This European Standard was approved by CEN on 9 March 2012.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2012 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 14891:2012: ESIST EN 14891:2012



EN 14891:2012 (E) 2 Contents Page Foreword .41 Scope .52 Normative references .53 Terms and definitions .64 Requirements .64.1 General .64.2 Release of dangerous substances .75 Evaluation of conformity .75.1 General .75.2 Initial type testing .75.3 Factory Production Control .85.3.1 General .85.3.2 Finished products .95.3.3 Equipment .95.3.4 Statistical techniques . 105.4 Registration, traceability and nonconforming materials . 105.4.1 Registration . 105.4.2 Identification and traceability . 105.4.3 Non-conforming materials and corrective actions . 105.4.4 Management and personnel . 106 Classification and designation . 107 Marking and labelling . 12Annex A (normative)
Test methods . 13A.1 Sampling . 13A.2 Test conditions . 13A.3 Test materials . 13A.3.1 General . 13A.3.2 Ceramic tiles . 13A.3.3 Test substrate . 14A.3.4 Ceramic tile adhesive . 14A.3.5 Sodium hypochlorite . 14A.4 Apparatus . 14A.5 Mixing of liquid-applied water impermeable products . 18A.6 Tensile adhesion tests . 18A.6.1 Preparation of test pieces . 18A.6.2 Initial tensile adhesion strength . 19A.6.3 Tensile adhesion strength after water contact . 19A.6.4 Alternative method for tensile adhesion strength after water contact . 19A.6.5 Tensile adhesion strength after heat ageing . 20A.6.6 Tensile adhesion strength after freeze-thaw cycle . 20A.6.7 Tensile adhesion strength after contact with chlorinated water . 20A.6.8 Alternative method for tensile adhesion strength after contact with chlorinated water . 21A.6.9 Tensile adhesion strength after contact with lime water . 21A.6.10 Evaluation and expression of the results . 22A.7 Water impermeability . 22A.8 Crack bridging ability . 24A.8.1 General . 24A.8.2 Crack bridging ability under standard conditions . 25SIST EN 14891:2012



EN 14891:2012 (E) 3 A.8.3 Crack bridging ability at low temperature. 25A.9 Test report . 25Annex ZA (informative)
Relationship between this European Standard and the Essential Requirements of EU Directive (89/106/EEC EU Construction Products Directive) . 27ZA.1 General . 27ZA.2 Procedure(s) for attestation of conformity of liquid applied water impermeable products . 29ZA.2.1 System of attestation of conformity . 29ZA.2.2 EC Declaration of conformity . 29ZA.3
CE marking and labelling. 30Bibliography . 33 SIST EN 14891:2012



EN 14891:2012 (E) 4 Foreword This document (EN 14891:2012) has been prepared by Technical Committee CEN/TC 67 “Ceramic tiles”, the secretariat of which is held by UNI. This document shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by October 2012 and conflicting national standards shall be withdrawn at the latest by October 2012. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 14891:2007. The significant technical changes between this European Standard and the previous edition are listed herewith: − new Annex ZA (informative); − modified clauses, subclauses (Foreword, 1, 4.1, 5.1, 5.3.3, 5.4.1, 6, 7 f), A.6.7, A.6.8, A.7) and tables (Tables 2 and 3). This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirements of EU Directive(s). For relationship with EU Directive(s), see informative Annex ZA, which is an integral part of this document. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. SIST EN 14891:2012



EN 14891:2012 (E) 5 1 Scope This European Standard applies to all liquid-applied water impermeable products, based on polymer modified cementitious mortars, dispersions and reaction resin coatings, used beneath ceramic tiling, for external tile installations on walls and floors and in swimming pools. This European Standard gives the terminology concerning the products and specifies the test methods and the values of performance requirements for liquid-applied water impermeable products associated with tile adhesives. This European Standard specifies the evaluation of conformity and the classification and designation of liquid-applied water impermeable products beneath ceramic tiling. This European Standard does not contain recommendations for the design and installation of ceramic tiles and grouts in combination with water impermeable products. NOTE 1 Liquid-applied water impermeable products may also be used beneath other types of tiles (natural and agglomerated stones, etc.), where they do not adversely affect these materials. NOTE 2 The user of this European Standard should be familiar with normal laboratory practice. This European Standard does not purport to address all the safety problems associated with its use. It is the responsibility of the user to establish appropriate health and safety practices and to ensure compliance with any European and national regulatory conditions. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 196-1:2005, Methods of testing cement — Part 1: Determination of strength EN 197-1:2011, Cement — Part 1: Composition, specifications and conformity criteria for common cements EN 480-1:2006+A1:2011, Admixtures for concrete, mortar and grout — Test methods — Part 1: Reference concrete and reference mortar for testing EN 1008, Mixing water for concrete — Specification for sampling, testing and assessing the suitability of water, including water recovered from processes in the concrete industry, as mixing water for concrete EN 1067, Adhesives — Examination and preparation of samples for testing EN 1323, Adhesives for tiles — Concrete slabs for tests EN 12004, Adhesives for tiles — Requirements, evaluation of conformity, classification and designation EN 12390-2, Testing hardened concrete — Part 2: Making and curing specimens for strength tests EN 12620:2002+A1:2008, Aggregates for concrete EN 14411:2006, Ceramic tiles — Definitions, classification, characteristics and marking EN ISO 15605, Adhesives — Sampling (ISO 15605) SIST EN 14891:2012



EN 14891:2012 (E) 6 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 liquid-applied water impermeable product single- or multicomponent waterproofing material applied in a uniform layer, beneath ceramic tiling Note 1 to entry: The water impermeable layer can include a reinforcing cloth or mesh. 3.2 polymer modified cementitious liquid-applied water impermeable product
CM mixture of hydraulic binding agents, aggregates and organic additives that has only to be mixed with water or liquid admixture just before use 3.3 dispersion liquid-applied water impermeable product
DM mixture of organic binding agent(s) in the form of an aqueous polymer dispersion, organic additives and mineral fillers Note 1 to entry: The mixture is ready for use. 3.4 reaction resin liquid-applied water impermeable product
RM mixture of synthetic resin, mineral fillers and organic additives in which hardening occurs by chemical reaction Note 1 to entry: They are available in one or more component forms. 3.5 crack bridging ability ability of the hardened waterproofing material to withstand propagation of the cracks without deterioration 3.6 primer liquid coating applied to the surface, prior to the application of a liquid product, to improve adhesion and durability of the bond 3.7 fundamental characteristics characteristics that a liquid-applied water impermeable product always needs to have 3.8 optional characteristics characteristics for specific service conditions where enhanced levels of performance are required or which provide further information about its general performance 4 Requirements 4.1 General The liquid-applied water impermeable products shall comply with the characteristics specified in Table 1, section 1 a. Table 1, section 1 b gives the additional characteristics that might be required for special service conditions. SIST EN 14891:2012



EN 14891:2012 (E) 7 The amount of water and/or liquid admixture required for preparing the cementitious liquid-applied water impermeable products shall be the same for all tests. Table 1 — Product requirements 1 a FUNDAMENTAL CHARACTERISTICS Characteristic Requirement Test method Initial tensile adhesion strength ≥ 0,5 N/mm2 A.6.2 Tensile adhesion strength after water contact ≥ 0,5 N/mm2 A.6.3 or A.6.4 Tensile adhesion strength after heat ageing ≥ 0,5 N/mm2 A.6.5 Tensile adhesion strength after freeze-thaw cycles ≥ 0,5 N/mm2 A.6.6 Tensile adhesion strength after contact with lime water ≥ 0,5 N/mm2 A.6.9 Waterproofing No penetration and ≤ 20 g weight gain A.7 Crack bridging ability under standard conditions ≥ 0,75 mm A.8.2 1 b OPTIONAL CHARACTERISTICS Characteristic Requirement Test method Tensile adhesion strength after contact with chlorinated water ≥ 0,5 N/mm2 A.6.7 or A.6.8 Crack bridging ability at low temperature (- 5°C) ≥ 0,75 mm A.8.3 Crack bridging ability at very low temperature (- 20°C) ≥ 0,75 mm A.8.3
4.2 Release of dangerous substances Materials used in products shall not release any dangerous substances in excess of the maximum permitted levels specified in a relevant European Standard for the material of permited in the national regulations of the member state of destination. 5 Evaluation of conformity 5.1 General
The compliance of liquid-applied water impermeable products with the requirements of this standard and with the declared values (including classes) shall be demonstrated by:  Initial Type Testing (ITT);  Factory Production Control (FTP) by the manufacturer, including product assessment. 5.2 Initial type testing On first evaluation of a product to the requirements of this European Standard, or before the beginning of sale of a new product, appropriate initial type testing shall be carried out to confirm that the characteristics of the product meet the requirements of this European Standard. Tests which have previously been performed in accordance with the provisions of this European Standard (same product, same characteristic, test method, SIST EN 14891:2012



EN 14891:2012 (E) 8 sampling procedure, etc.) may be taken into account for the purpose of demonstrating satisfactory initial type testing. In these cases the appropriate initial type testing to be carried out shall be for those characteristics and properties that can be affected and need confirmation; any new property or properties arising from a change of formulation or manufacturing procedure shall be tested and the results reported. The initial type testing shall be performed as listed in Table 2. The results of initial tests shall be recorded and be available for inspection. They shall be kept for at least 10 years after the date of last manufacture of the product to which they relate. Only one ITT is required where different manufacturing units are producing the same product, for the same manufacturer, using the same materials (having the same performance) and documented production and process control. Where components (e.g. cement) are used whose characteristics have already been determined by the component supplier on the basis of conformity with other product standards, these characteristics need not be re-assessed to demonstrate compliance with the European Standard. Retesting due to a new method of production or product modification, or change of supplier of components, shall only be performed if one or more of the stated performance characteristics will be downgraded, i.e. the mix design becomes dissimilar. A manufacturer may, however, always retest if he wishes to declare improved performance. 5.3 Factory Production Control 5.3.1 General 5.3.1.1 Factory Production Control plan and procedures A Factory Production Control (FPC) plan shall be established and documented in a manual. Any change in raw materials, manufacturing procedures or control plan that can affect the properties of the product shall be recorded. The manual shall include the FPC procedures relevant to the declared properties, as confirmed by the initial tests. The FPC procedures shall consist of a system for the production quality control to ensure that the product conforms to this European Standard. The production control shall consist of the following main phases:  inspection and testing of raw materials;  inspection and testing of production equipment and process;  inspection and testing of finished products. NOTE Manufacturers having a Quality System complying with EN ISO 9001 [3] and made specific to the requirements of this European Standard are assumed to meet the requirements related to Factory Production Control.
5.3.1.2 Raw materials The acceptance criteria and control procedures for incoming materials shall be defined by the manufacturer, to ensure that these are not used until it has been verified that they conform to the required specifications. SIST EN 14891:2012



EN 14891:2012 (E) 9 5.3.1.3 Production process The manufacturer shall identify and define the plant and production processes and ensure that the processes are carried out under controlled conditions clearly described in documented operating procedures. The processes shall be verified by means of inspections and testing documented in a plan, as frequency and values or criteria required, both on equipment and on operations in the process. The action to be taken when control values or criteria are not obtained shall be given. 5.3.2 Finished products As appropriate, the factory production control system incorporates a sampling plan and the frequency of testing for the finished product. The number and size of the samples, the frequency of sampling, the tests performed and the results obtained, shall be recorded. The frequency of sampling and testing can be determined from statistical principles, ensuring that the corresponding production conforms to the compliance criteria in this European Standard and achieves the required values for products. The tests can also be performed with the frequency described in Table 2. These records shall be available for inspection. Table 2 — Initial type testing and production control frequency Characteristic Test method Initial type test Production control frequency Initial tensile adhesion strength A.6.2 y A Tensile adhesion strength after water contact A.6.3 or A.6.4 y A Tensile adhesion strength after heat ageing A.6.5 y A Tensile adhesion strength after freeze-thaw cycles A.6.6 y A Tensile adhesion strength after contact with lime water A.6.9 y A Waterproofing A.7 y A Crack-bridging ability under standard conditions A.8.2 y A Tensile adhesion strength after contact with chlorinated water A.6.7 or A.6.8 (y) (A) Crack-bridging ability at low temperature A.8.3 (y) (A) NOTE y means « yes » ; (y) means « yes, if relevant for the product ».
A means «at six month interval»; (A) means «at six month interval, if relevant for the product».
For the purpose of the Factory Production Control alternative tests to those given in Table 2 may be used, provided that a correlation of the results between both tests, for the product in question, is established. The use of alternative tests shall be recorded, maintained and be made available on request. 5.3.3 Equipment All the measuring instruments used for production or testing shall be identified, calibrated and kept in good order, in accordance with documented procedures and instructions. The manufacturer shall establish an appropriate plan detailing the procedures and frequency of these checks and shall maintain the registrations. Test equipment shall be calibrated to traceable standards. SIST EN 14891:2012



EN 14891:2012 (E) 10 5.3.4 Statistical techniques Where and when possible and applicable, the results of inspections and testing shall be interpreted by means of statistical techniques, by attributes or by variables, to verify the product characteristics and to determine if the production conforms with the compliance criteria and the product conforms to the declared values. 5.4 Registration, traceability and nonconforming materials 5.4.1 Registration The records of inspections and testing shall be collected, stored and retained in a way to prevent damage, deterioration or loss. These records shall be maintained for 5 years and shall be made available on request from a relevant party. 5.4.2 Identification and traceability Where appropriate, the manufacturer shall establish and maintain in the FPC manual suitable procedures for the identification and traceability of materials from receipt of raw materials and during all stages of production and delivery. 5.4.3 Non-conforming materials and corrective actions The manufacturer shall ensure by means of procedures, documented in the FPC manual, that the materials (raw materials, packaging, finished products) that do not conform to the specified requirements are clearly identified and/or segregated to prevent their use or despatch. The non-conforming material may be reworked to meet the specifications, reclassified or rejected and discarded, with a corrective action described and recorded in a non-conformity report. 5.4.4 Management and personnel The management activities to ensure that all of the above requirements operate shall be described in the manual. The manufacturer shall ensure that all personnel involved in the process receive the appropriate training to perform their duties. Where appropriate, all educational and training activities shall be recorded to prove the personnel qualification. The job description and the responsibilities of the operatives shall be given in the FPC manual. 6 Classification and designation The liquid-applied water impermeable products are classified into one of the three types, according to the definitions given in Clause 3:  CM
cementitious liquid-applied water impermeable products;  DM
dispersion liquid-applied water impermeable products;  RM
reaction resin liquid-applied water impermeable products. For each type it is possible to have different classes, related to the different optional characteristics given in
Table 1, section 1b. These classes are designated by the following abbreviations: SIST EN 14891:2012



EN 14891:2012 (E) 11  O1 with improved crack bridging ability at low temperature (-5°C);  O2 with improved crack bridging ability at low temperature (-20°C);  P resistant to contact with chlorinated water (i.e. for use in swimming pools). The product is designated by the symbol for the type (CM, DM or RM), followed by the abbreviation of the class or classes it belongs to. Table 3 describes the designation of the products types and classes which shall be used. Table 3 — Classification and designation of liquid-applied water impermeable products SYMBOL DESCRIPTION TYPE CLASS CM
Normal cementitious liquid-applied water impermeable product DM
Normal dispersion liquid-applied water impermeable product RM
Normal reaction resin liquid-applied water impermeable product CM O1 Cementitious liquid-applied water impermeable product with improved crack bridging ability at low temperature (-5°C) CM O2 Cementitious liquid-applied water impermeable product with improved crack bridging ability at low temperature (-20°C) DM O1 Dispersion liquid-applied water impermeable product with improved crack bridging ability at low temperature (-5°C) DM O2 Dispersion liquid-applied water impermeable product with improved crack bridging ability at low temperature (-20°C) RM O1 Reaction resin liquid-applied water impermeable product with improved crack bridging ability at low temperature (-5°C) RM O2 Reaction resin liquid-applied water impermeable product with improved crack bridging ability at low temperature (-20°C) CM P Cementitious liquid-applied water impermeable product resistant to contact with chlorinated water DM P Dispersion liquid-applied water impermeable product resistant to contact with chlorinated water RM P Reaction resin liquid-a
...