SIST EN IEC 60730-2-24:2026
(Main)Automatic electrical controls - Part 2-24: Particular requirements for displacement electrical controls
- Abstract
This clause of Part 1 is replaced by the following:
This part of IEC 60730 applies to automatic displacement electrical controls
– for use in, on, or in association with appliances for household and similar use;
NOTE 1 Through this document, the word "control" means "displacement electrical control".
EXAMPLE 1 Displacement electrical controls used in electrical pressure cookers with gross volume up to 25 l, with working pressure over 4 kPa and less than 150 kPa.
– that are AC or DC powered controls with a rated voltage not exceeding 690 V AC or 600 V DC;
– used in, on, or in association with equipment that use electricity;
– that are mechanically or electrically operated, responsive to change of position of point of action.
NOTE 2 Requirements for manual switches not forming part of an automatic control are covered in IEC 61058-1-1.
This document applies to
– inherent safety of automatic electro-mechanical displacement electrical controls;
– functional safety of automatic electro-mechanical displacement electrical controls;
– the operating values, operating times, and operating sequences where such are associated with equipment safety;
– displacement electrical controls having temperature sensing element(s), in which cases additional requirements can be considered to be necessary. Requirements for temperature sensing controls are included in IEC 60730-2-9.
This document specifies the requirements for construction, operation and testing of automatic displacement electrical controls used in, on, or in association with equipment.
This document does not
– apply to automatic electronic controls;
– take into account the response value of an automatic action of a control, if such a response value is dependent upon the method of mounting the control in the equipment. Where a response value is of significant purpose for the protection of the user, or surroundings, the value defined in the appropriate equipment standard or as determined by the manufacturer applies.
NOTE 3 For more information about guidance to the application of displacement electrical controls, see Annex AA.
- Status
- Published
- Public Enquiry End Date
- 31-Oct-2025
- Publication Date
- 09-Sep-2026
- Technical Committee
- ISS EIT.NZG - Household apliances
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 29-Jul-2026
- Due Date
- 03-Oct-2026
- Completion Date
- 10-Sep-2026
SIST EN IEC 60730-2-24:2026 is the Slovenian adoption of EN IEC 60730-2-24:2026, based on IEC 60730-2-24:2026. It specifies particular requirements for automatic displacement electrical controls used in household and similar appliances and in equipment that uses electricity. The document covers construction, operation and testing for electro-mechanical controls that respond to displacement of the point of action.
What does SIST EN IEC 60730-2-24:2026 specify?
SIST EN IEC 60730-2-24:2026 applies to automatic displacement electrical controls for use in, on, or in association with household and similar appliances, including AC or DC powered controls up to 690 V AC or 600 V DC. It is written for controls that are mechanically or electrically operated and respond to movement of the point of action.
The standard follows the Part 1 structure and then replaces or modifies the relevant clauses for this control type. The main body covers clauses 1 to 26, with Annex H for functional safety and Annex AA for application guidance.
| Annex | What it covers |
|---|---|
| H | Functional safety requirements, including drift and deviation checks |
| AA | Guidance for selection, installation and use in end products |
| ZA | Normative references to international publications and their European equivalents |
What are the key requirements of SIST EN IEC 60730-2-24:2026?
The control type and its intended use
SIST EN IEC 60730-2-24:2026 is for automatic electro-mechanical displacement electrical controls, not automatic electronic controls. Clause 1 also says that controls with temperature sensing elements may need additional requirements, and it points to IEC 60730-2-9 for temperature sensing controls.
In practice, this means a manufacturer has to choose the right control family before testing starts. The document is aimed at controls whose safety function depends on displacement, not on pressure sensing or a manual switch.
The manufacturer has to declare the key technical data
Clause 5 and Table 1 require the technical information needed to design, test and use the control. The table covers the control purpose, temperature limits, number of automatic cycles, free position, disconnection travel distance, self-locking travel distance, limit travel distance, reset travel distance, operation speed, maximum hold-on time, force limit and maximum ambient temperature.
That matters because the declared values become the reference for compliance testing and for end-product integration. If the application changes, the declared values and the installation method have to match the real appliance.
Position limiter and position regulator behaviour is tightly controlled
Clause 9.3.101 treats a displacement electrical control with an integrated protective function as a protective control. For a position limiter, once the self-locking travel distance is reached, the control must not reconnect automatically unless it is reset manually.
Clause 19.15.101 and 19.15.102 then test position regulators and position limiters separately. The tests check limit travel distance or self-locking travel distance after an initial cycle run, so the control must keep its function after repeated operation.
The disconnection point must stay within the declared tolerance
Clause 9.4.3 states that the disconnection travel distance is a type 2 action and shall not deviate from the declared value by more than ±5 %. Annex H uses a micrometer-based method to measure the travel distance and confirm the declared value.
For a buyer or test lab, this means the switching point is not just qualitative. It is a measurable setting that must stay close to the declared value during verification and after endurance testing.
Heating and endurance tests are part of the qualification
Clause 16.5 defines the heating test conditions for the switch head and mounting surface. Clause 19.3.1 then adapts the temperature conditions for endurance testing, including an additional low-temperature check when the switch head is below 0 °C.
Clause 19.1 and Table 1 also link the test programme to the number of automatic cycles. The document sets a minimum number of cycles for disconnection action and for the self-locking mechanism, so endurance is verified under repeated use rather than only at first operation.
Annex H adds functional safety checks
Annex H gives extra requirements for manufacturing deviation and drift. It covers how the control is mounted in a fixture, how sensing is checked, and how the disconnection travel distance is measured and recorded after repeated operation.
This matters when the control is part of a safety function in the end product. The annex focuses on stability, repeatability and the ability of the control to keep working after transport, storage and cycling.
Annex AA explains how to select and mount the control
Annex AA is guidance, not a test clause, but it is important for real applications. It says the end-product manufacturer is responsible for correct installation, and it gives examples for pressure cooker-type appliances.
The annex helps the user match pressure, temperature and current ratings to the appliance, and it describes two installation modes. That makes it easier to choose a control that fits both the appliance design and the safety function.
What terms does SIST EN IEC 60730-2-24:2026 define?
- Displacement electrical control - an automatic control in which the point of action moves because the container displacement changes with pressure.
- Position limiter - a displacement electrical control intended to keep the position below one value during normal use.
- Position regulator - a cycling displacement electrical control intended to keep the position between two values.
- Free position - the initial state of the point of action before displacement starts.
- Disconnection position - the point where the contact is opened by the action mechanism.
- Self-locking position - the point where the self-locking mechanism operates and further displacement can continue.
- Reset position - the position at which the disconnected contact reconnects when displacement is reduced.
- Point of action - the point on the control where displacement is applied.
Who uses SIST EN IEC 60730-2-24:2026?
SIST EN IEC 60730-2-24:2026 is used by control designers, appliance manufacturers, test laboratories, quality teams and buyers who need to specify or verify displacement electrical controls. The main application area is household and similar equipment, including pressure cooker-type appliances and other products where the control acts through movement of the point of action.
It is especially useful for end-product manufacturers who have to integrate the control correctly, set the declared travel values, and confirm that the safety function works in the assembled appliance.
Which standards are used with SIST EN IEC 60730-2-24:2026?
| Standard | How it is used |
|---|---|
| EN IEC 60730-1 / IEC 60730-1 | The general Part 1 document that Part 2-24 reads with and modifies |
| IEC 61058-1-1 | Covers manual switches that are not part of an automatic control |
| IEC 60730-2-9 | Covers temperature sensing controls |
| IEC 60730-2-6 | A related part for automatic pressure sensing controls, listed in the bibliography |
What does the SIST EN IEC 60730-2-24:2026 document contain?
The document contains clause-by-clause requirements for construction, operation and testing, together with specific modifications to Part 1. It includes required technical information in Table 1, and the main test and measurement arrangements are shown in Figures 101 to 103.
Annex H adds functional safety methods, including drift and deviation measurement with a test fixture and micrometer. Annex AA adds installation guidance and two example layouts for pressure cooker applications.
Relations
- Effective Date
- 28-Jul-2026
- Effective Date
- 28-Jul-2026
- Effective Date
- 28-Jul-2026
- Effective Date
- 28-Jul-2026
- Effective Date
- 28-Jul-2026
Frequently Asked Questions
SIST EN IEC 60730-2-24:2026 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Automatic electrical controls - Part 2-24: Particular requirements for displacement electrical controls". This standard covers: This clause of Part 1 is replaced by the following: This part of IEC 60730 applies to automatic displacement electrical controls – for use in, on, or in association with appliances for household and similar use; NOTE 1 Through this document, the word "control" means "displacement electrical control". EXAMPLE 1 Displacement electrical controls used in electrical pressure cookers with gross volume up to 25 l, with working pressure over 4 kPa and less than 150 kPa. – that are AC or DC powered controls with a rated voltage not exceeding 690 V AC or 600 V DC; – used in, on, or in association with equipment that use electricity; – that are mechanically or electrically operated, responsive to change of position of point of action. NOTE 2 Requirements for manual switches not forming part of an automatic control are covered in IEC 61058-1-1. This document applies to – inherent safety of automatic electro-mechanical displacement electrical controls; – functional safety of automatic electro-mechanical displacement electrical controls; – the operating values, operating times, and operating sequences where such are associated with equipment safety; – displacement electrical controls having temperature sensing element(s), in which cases additional requirements can be considered to be necessary. Requirements for temperature sensing controls are included in IEC 60730-2-9. This document specifies the requirements for construction, operation and testing of automatic displacement electrical controls used in, on, or in association with equipment. This document does not – apply to automatic electronic controls; – take into account the response value of an automatic action of a control, if such a response value is dependent upon the method of mounting the control in the equipment. Where a response value is of significant purpose for the protection of the user, or surroundings, the value defined in the appropriate equipment standard or as determined by the manufacturer applies. NOTE 3 For more information about guidance to the application of displacement electrical controls, see Annex AA.
This clause of Part 1 is replaced by the following: This part of IEC 60730 applies to automatic displacement electrical controls – for use in, on, or in association with appliances for household and similar use; NOTE 1 Through this document, the word "control" means "displacement electrical control". EXAMPLE 1 Displacement electrical controls used in electrical pressure cookers with gross volume up to 25 l, with working pressure over 4 kPa and less than 150 kPa. – that are AC or DC powered controls with a rated voltage not exceeding 690 V AC or 600 V DC; – used in, on, or in association with equipment that use electricity; – that are mechanically or electrically operated, responsive to change of position of point of action. NOTE 2 Requirements for manual switches not forming part of an automatic control are covered in IEC 61058-1-1. This document applies to – inherent safety of automatic electro-mechanical displacement electrical controls; – functional safety of automatic electro-mechanical displacement electrical controls; – the operating values, operating times, and operating sequences where such are associated with equipment safety; – displacement electrical controls having temperature sensing element(s), in which cases additional requirements can be considered to be necessary. Requirements for temperature sensing controls are included in IEC 60730-2-9. This document specifies the requirements for construction, operation and testing of automatic displacement electrical controls used in, on, or in association with equipment. This document does not – apply to automatic electronic controls; – take into account the response value of an automatic action of a control, if such a response value is dependent upon the method of mounting the control in the equipment. Where a response value is of significant purpose for the protection of the user, or surroundings, the value defined in the appropriate equipment standard or as determined by the manufacturer applies. NOTE 3 For more information about guidance to the application of displacement electrical controls, see Annex AA.
SIST EN IEC 60730-2-24:2026 is classified under the following ICS (International Classification for Standards) categories: 97.120 - Automatic controls for household use. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN IEC 60730-2-24:2026 has the following relationships with other standards: It is inter standard links to SIST EN 15500-1:2018, SIST EN 12977-5:2012, SIST EN 12098-5:2018, SIST EN 15500:2008, SIST EN 12977-5:2018. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
SIST EN IEC 60730-2-24:2026 is associated with the following European legislation: EU Directives/Regulations: 2014/30/EU, 2014/35/EU, 2014/53/EU; Standardization Mandates: M/511, M/536, M/552. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
SIST EN IEC 60730-2-24:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-oktober-2026
Avtomatske električne krmilne naprave - 2-24. del: Posebne zahteve za premične
električne krmilne naprave
Automatic electrical controls - Part 2-24: Particular requirements for displacement
electrical controls
Automatische elektrische Regel- und Steuergeräte - Teil 2-24: Besondere
Anforderungen an elektrische Verschiebung messende Regel- und Steuergeräte
Dispositifs de commande électrique automatiques - Partie 2-24: Exigences particulières
pour les dispositifs de commande électriques de déplacement
Ta slovenski standard je istoveten z: EN IEC 60730-2-24:2026
ICS:
97.120 Avtomatske krmilne naprave Automatic controls for
za dom household use
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD EN IEC 60730-2-24
NORME EUROPÉENNE
EUROPÄISCHE NORM July 2026
ICS 97.120
English Version
Automatic electrical controls - Part 2-24: Particular requirements
for displacement electrical controls
(IEC 60730-2-24:2026)
Dispositifs de commande électrique automatiques - Partie Automatische elektrische Regel- und Steuergeräte - Teil 2-
2-24: Exigences particulières pour les dispositifs de 24: Besondere Anforderungen an elektrische Verschiebung
commande électriques de déplacement messende Regel- und Steuergeräte
(IEC 60730-2-24:2026) (IEC 60730-2-24:2026)
This European Standard was approved by CENELEC on 2026-07-01. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the
Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Türkiye and the United Kingdom.
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2026 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN IEC 60730-2-24:2026 E
European foreword
The text of document 72/1506/CDV, future edition 1 of IEC 60730-2-24, prepared by TC 72 "Automatic
electrical controls" was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as
The following dates are fixed:
• latest date by which the document has to be implemented at national (dop) 2027-07-31
level by publication of an identical national standard or by endorsement
• latest date by which the national standards conflicting with the (dow) 2029-07-31
document have to be withdrawn
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC shall not be held responsible for identifying any or all such patent rights.
This document is read in conjunction with EN IEC 60730-1.
Any feedback and questions on this document should be directed to the users’ national committee. A
complete listing of these bodies can be found on the CENELEC website.
Endorsement notice
The text of the International Standard IEC 60730-2-24:2026 was approved by CENELEC as a
European Standard without any modification.
In the official version, for Bibliography, the following notes have to be added for the standard indicated:
IEC 60730-2-6 NOTE Approved as EN IEC 60730-2-6
IEC 60730-2-9 NOTE Approved as EN IEC 60730-2-9
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments)
applies.
NOTE 1 Where an International Publication has been modified by common modifications, indicated by (mod),
the relevant EN/HD applies.
NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is available
here: www.cencenelec.eu.
Annex ZA of EN IEC 60730-1 applies.
IEC 60730-2-24 ®
Edition 1.0 2026-05
INTERNATIONAL
STANDARD
Automatic electrical controls -
Part 2-24: Particular requirements for displacement electrical controls
ICS 97.120 ISBN 978-2-8327-1192-7
IEC 60730-2-24:2026-05(en)
IEC 60730-2-24:2026 © IEC 2026
CONTENTS
FOREWORD . 2
1 Scope . 4
2 Normative references . 4
3 Terms and definitions . 5
4 General . 6
5 Required technical information . 7
6 Protection against electric shock . 8
7 Provision for protective earthing . 9
8 Terminals and terminations. 9
9 Constructional requirements . 9
10 Threaded parts and connections . 9
11 Creepage distances, clearances and distances through solid insulation . 9
12 Components . 10
13 Fault assessment on electronic circuits . 10
14 Moisture and dust resistance . 10
15 Electric strength and insulation resistance . 10
16 Heating . 10
17 Manufacturing deviation and drift . 10
18 Environmental stress . 10
19 Endurance . 11
20 Mechanical strength . 12
21 Resistance to heat, fire and tracking . 13
22 Resistance to corrosion . 13
23 Electromagnetic compatibility (EMC) requirements – Emission . 13
24 Normal operation . 13
25 Electromagnetic compatibility (EMC) requirements – Immunity . 13
26 Abnormal operation tests . 13
Annex H (normative) Requirements related to functional safety . 16
Annex AA (informative) Guide to the application of displacement electrical controls
within the scope of this standard . 19
Bibliography . 23
Figure 101 – Positions and travel distance of displacement electrical controls . 14
Figure 102 – Drawing for measuring the disconnection travel distance. 15
Figure 103 – An example of test fixture . 15
Figure AA.1 – Diagram of example 1 . 20
Figure AA.2 – Diagram of example 2 . 21
Table 1 – Required technical information and methods of providing these information . 7
IEC 60730-2-24:2026 © IEC 2026
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
Automatic electrical controls -
Part 2-24: Particular requirements for displacement electrical controls
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international
co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and
in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports,
Publicly Available Specifications (PAS) and Guides (hereafter referred to as "IEC Publication(s)"). Their
preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with
may participate in this preparatory work. International, governmental and non-governmental organizations liaising
with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for
Standardization (ISO) in accordance with conditions determined by agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence between
any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) IEC draws attention to the possibility that the implementation of this document may involve the use of (a)
patent(s). IEC takes no position concerning the evidence, validity or applicability of any claimed patent rights in
respect thereof. As of the date of publication of this document, IEC had not received notice of (a) patent(s), which
may be required to implement this document. However, implementers are cautioned that this may not represent
the latest information, which may be obtained from the patent database available at https://patents.iec.ch. IEC
shall not be held responsible for identifying any or all such patent rights.
IEC 60730-2-24 has been prepared by IEC technical committee 72: Automatic electrical
controls. It is an International Standard.
The text of this International Standard is based on the following documents:
Draft Report on voting
72/1506/CDV 72/1525/RVC
Full information on the voting for its approval can be found in the report on voting indicated in
the above table.
The language used for the development of this International Standard is English.
IEC 60730-2-24:2026 © IEC 2026
This document was drafted in accordance with ISO/IEC Directives, Part 2, and developed in
accordance with ISO/IEC Directives, Part 1 and ISO/IEC Directives, IEC Supplement, available
at www.iec.ch/members_experts/refdocs. The main document types developed by IEC are
described in greater detail at www.iec.ch/publications.
This part 2-24 is intended to be used in conjunction with IEC 60730-1. It was established on the
basis of the sixth edition of that standard (2022). Consideration may be given to future editions
of, or amendments to, IEC 60730-1.
This part 2-24 supplements or modifies the corresponding clauses in IEC 60730-1, so as to
convert that publication into the IEC standard: Particular requirements for displacement
electrical controls.
Where this part 2-24 states "addition", "modification" or "replacement", the relevant requirement,
test specification or explanatory matter in Part 1 should be adapted accordingly.
Where no change is necessary, part 2-24 indicates that the relevant clause or subclause applies.
In the development of a fully international standard, it has been necessary to take into
consideration the differing requirements resulting from practical experience in various parts of
the world and to recognize the variation in national electrical systems and wiring rules.
In this publication:
– The following print types are used:
• requirements proper: in roman type;
• test specifications: in italic type;
• explanatory matter: in smaller roman type.
• Defined terms: bold type.
– Subclauses, notes or items which are additional to those in Part 1 are numbered starting
from 101, additional annexes are lettered AA, BB, etc.
A list of all parts of the IEC 60730 series, under the general title Automatic electrical controls,
can be found on the IEC website.
The committee has decided that the contents of this document will remain unchanged until the
stability date indicated on the IEC website under webstore.iec.ch in the data related to the
specific document. At this date, the document will be
– reconfirmed,
– withdrawn, or
– revised.
IEC 60730-2-24:2026 © IEC 2026
1 Scope
This clause of Part 1 is replaced by the following:
This part of IEC 60730 applies to automatic displacement electrical controls
– for use in, on, or in association with appliances for household and similar use;
NOTE 1 Through this document, the word "control" means "displacement electrical control".
EXAMPLE 1 Displacement electrical controls used in electrical pressure cookers with gross volume up to 25 l,
with working pressure over 4 kPa and less than 150 kPa.
– that are AC or DC powered controls with a rated voltage not exceeding 690 V AC or 600 V
DC;
– used in, on, or in association with equipment that use electricity;
– that are mechanically or electrically operated, responsive to change of position of point of
action.
NOTE 2 Requirements for manual switches not forming part of an automatic control are covered in IEC 61058-1-1.
This document applies to
– inherent safety of automatic electro-mechanical displacement electrical controls;
– functional safety of automatic electro-mechanical displacement electrical controls;
– the operating values, operating times, and operating sequences where such are associated
with equipment safety;
– displacement electrical controls having temperature sensing element(s), in which cases
additional requirements can be considered to be necessary. Requirements for temperature
sensing controls are included in IEC 60730-2-9.
This document specifies the requirements for construction, operation and testing of automatic
displacement electrical controls used in, on, or in association with equipment.
This document does not
– apply to automatic electronic controls;
– take into account the response value of an automatic action of a control, if such a response
value is dependent upon the method of mounting the control in the equipment. Where a
response value is of significant purpose for the protection of the user, or surroundings, the
value defined in the appropriate equipment standard or as determined by the manufacturer
applies.
NOTE 3 For more information about guidance to the application of displacement electrical controls, see
Annex AA.
2 Normative references
This clause of Part 1 is applicable.
IEC 60730-2-24:2026 © IEC 2026
3 Terms and definitions
This clause of Part 1 is applicable except as follows:
3.2 Definitions of types of control according to purpose
Additional definitions:
3.2.101
displacement electrical control
automatic control where the displacement of point of action occurs through the displacement
of the container due to pressure change
Note 1 to entry: The container is an inner pot in the case of rice cooker.
Note 2 to entry: The displacement electrical control is considered an operating control with a type 2 action and
normally a protective control is provided on the end product to prevent a hazard, therefore there is no need to verify
the robustness of the self-locking mechanism.
3.2.102
position limiter
displacement electrical control which is intended to keep a position below one particular
value during normal operating conditions and which may have provision for setting by the end-
product manufacturer
Note 1 to entry: A position limiter can be manual reset type.
3.2.103
position regulator
cycling displacement electrical control, which is intended to keep a position between two
particular values under normal operating conditions and which may have provision for setting
by the end-product manufacturer
3.4 Definitions relating to disconnection and interruption
Additional definitions:
3.4.101
free position
P
f
initial state of the point of action of the displacement electrical control
Note 1 to entry: P is indicated as the position of 0 displacement in Figure 101.
f
Note 2 to entry: In general, free position is at located position.
3.4.102
disconnection position
P
d
position where the contact is disconnected from the circuit by the action mechanism under the
external force
Note 1 to entry: P is indicated in Figure 101.
d
3.4.103
self-locking position
P
s
position in which the self-locking mechanism just operates while the displacement can continue
to increase when the contact is disconnected
IEC 60730-2-24:2026 © IEC 2026
3.4.104
limit position
P
l
farthest position of the action mechanism of the displacement electrical control that can be
reached under external force where the action mechanism can recover to the free position
when the external force is released
Note 1 to entry: P is indicated in Figure 101.
l
3.4.105
reset position
P
r
position of the action mechanism where the disconnected contact will be re-connected when
the displacement is reduced
Note 1 to entry: P is indicated in Figure 101.
r
3.4.106
disconnection travel distance
distance between free position and disconnection position
3.4.107
self-locking travel distance
distance between disconnection position and self-locking position
3.4.108
limit travel distance
distance between free position and limit position
3.4.109
reset travel distance
distance between free position and reset position
3.4.110
point of action
point on the displacement electrical control at which the displacement is made
3.8 Definitions relating to component parts of controls
3.8.3
actuating member
Additional note:
Note 101 to entry: In Clause 19 of this document, the term "actuating member" includes that part which is
mechanically moved, pulled, pushed or turned to cause initiation of a control action.
4 General
This clause of Part 1 is applicable except as follows:
4.3.4.5.1
Additional paragraph:
For the displacement electrical controls designed with two or more sensing positions for
multiple functions, the relevant tests shall be applied to the individual sensing position, one at
a time.
IEC 60730-2-24:2026 © IEC 2026
5 Required technical information
This clause of Part 1 is applicable except as follows:
Table 1 – Required technical information and methods
of providing these information
Information Clause or subclause Method
Modifications:
3.2, 4.3.4.2, 4.3.4.5,
6 Purpose of control D or E
19.15, 3.2.101, 3.2.102
16 Temperature limits of mounting surfaces (T ) 16.5, C
s
19.3.1
Maximum temperature of mounting surface (T ) if it is more than
smax
20 K above T
19.15.101
max
19.15.102
NOTE 1 If the displacement electrical control is intended for