SIST EN 12574-2:2017
(Main)Stationary waste containers - Part 2: Performance requirements and test methods
Stationary waste containers - Part 2: Performance requirements and test methods
This part of EN 12574 specifies the test methods for stationary waste containers (in the text also called containers) according to prEN 12574-1. It also specifies the target requirements to be reached either during or after the tests.
Stationäre Abfallsammelbehälter - Teil 2: Anforderungen an die Ausführung und Prüfverfahren
Dieser Teil der Normenreihe EN 12574 legt die Prüfverfahren für stationäre Abfallsammelbehälter (im Folgenden auch kurz Behälter genannt) nach prEN 12574 1 fest. Sie legt auch die Soll Anforderungen fest, die während oder nach den Prüfungen erreicht werden müssen.
Conteneurs fixes à déchets - Partie 2 : Exigences de performance et méthodes d'essais
La présente partie du prEN 12574 spécifie les méthodes d’essais pour les conteneurs fixes à déchets (également appelés « conteneurs » dans le texte) conformes au prEN 12574-1. Elle indique aussi le niveau d’exigences à atteindre lors des essais ou après les essais.
Nepremični zabojniki za odpadke - 2. del: Izvedbene zahteve in preskusne metode
Ta del standarda EN 12574 določa preskusne metode za nepremične zabojnike za odpadke (v besedilu tudi zabojniki), ki so skladne s standardom prEN 12574-1. Poleg tega določa tudi ciljne zahteve, ki naj bi bile dosežene med ali po preskusih.
General Information
Relations
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Stationäre Abfallsammelbehälter - Teil 2: Anforderungen an die Ausführung und PrüfverfahrenConteneurs fixes à déchets - Partie 2 : Exigences de performance et méthodes d'essaisStationary waste containers - Part 2: Performance requirements and test methods13.030.40Naprave in oprema za odstranjevanje in obdelavo odpadkovInstallations and equipment for waste disposal and treatmentICS:Ta slovenski standard je istoveten z:EN 12574-2:2017SIST EN 12574-2:2017en,fr,de01-april-2017SIST EN 12574-2:2017SLOVENSKI
STANDARDSIST EN 12574-2:20061DGRPHãþD
SIST EN 12574-2:2017
EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 12574-2
February
t r s y ICS
s uä r u rä v r Supersedes EN
s t w y væ tã t r r xEnglish Version
Stationary waste containers æ Part
tã Performance requirements and test methods Conteneurs fixes à déchets æ Partie
t ã Exigences de performance et méthodes d 5essais
Stationäre Abfallsammelbehälter æ Teil
tã Anforderungen an die Ausführung und PrüfverfahrenThis European Standard was approved by CEN on
t s November
t r s xä
egulations which stipulate the conditions for giving this European Standard the status of a national standard without any alterationä Upætoædate lists and bibliographical references concerning such national standards may be obtained on application to the CENæCENELEC Management Centre or to any CEN memberä
translation under the responsibility of a CEN member into its own language and notified to the CENæCENELEC Management Centre has the same status as the official versionsä
CEN members are the national standards bodies of Austriaá Belgiumá Bulgariaá Croatiaá Cyprusá Czech Republicá Denmarká Estoniaá Finlandá Former Yugoslav Republic of Macedoniaá Franceá Germanyá Greeceá Hungaryá Icelandá Irelandá Italyá Latviaá Lithuaniaá Luxembourgá Maltaá Netherlandsá Norwayá Polandá Portugalá Romaniaá Serbiaá Slovakiaá Sloveniaá Spainá Swedená Switzerlandá Turkey and United Kingdomä
EUROPEAN COMMITTEE FOR STANDARDIZATION COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre:
Avenue Marnix 17,
B-1000 Brussels
9
t r s y CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Membersä Refä Noä EN
s t w y væ tã t r s y ESIST EN 12574-2:2017
EN 12574-2:2017 (E) 2 Contents Page European foreword . 3 1 Scope . 4 2 Normative references . 4 3 Terms and definitions . 4 4 Tests . 5 4.1 General . 5 4.2 Control before the tests. 5 4.2.1 Visual aspects . 5 4.2.2 Correspondence with EN 12574-1:2017 . 5 4.2.3 Masses limit deviations . 6 4.2.4 Colour . 6 4.2.5 Marking . 6 4.3 Control after the tests . 6 4.4 Conditions of the tests . 6 4.5 Test load . 6 4.6 Tests on the containers . 6 4.6.1 General . 6 4.6.2 Impact test by ball drop . 6 4.6.3 Impact on an inclined plane . 8 4.7 Stability test . 9 4.8 Dynamic tests . 9 4.8.1 General . 9 4.8.2 Pulling test . 9 4.8.3 Immobilization test . 10 4.9 Lifting-tilting tests . 10 4.9.1 General . 10 4.9.2 Lifting-tilting empty container . 10 4.9.3 Lifting-tilting of the loaded container. 10 4.10 Miscellaneous tests . 11 4.10.1 Internal stress-cracking tests (for thermo plastics only) . 11 4.10.2 Corrosion test . 11 4.10.3 Weathering . 11 4.10.4 Test method with child mannequin for containers with sliding mobile flap . 12 4.10.5 Test for locked lid . 13 4.10.6 Sequence of the tests . 13 5 Tests report . 14 Annex A (normative)
Device for ball drop test . 15 Annex B (informative)
Apparatus for lateral impact test on inclined plane . 16 Annex C (normative)
Weathering tests . 17 Annex D (informative)
A–deviations . 18 Bibliography . 19
SIST EN 12574-2:2017
EN 12574-2:2017 (E) 3 European foreword This document (EN 12574-2:2017) has been prepared by Technical Committee CEN/TC 183 “Waste management”, the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by August 2017, and conflicting national standards shall be withdrawn at the latest by August 2017. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 12574-2:2006. This European Standard is one part of the series of standards EN 12574 about “Stationary waste containers” comprising the following parts: — Part 1: Containers with a capacity up to 10 000 l with flat or dome lid(s), for trunnion, double trunnion or pocket lifting device — Dimensions and design; — Part 2: Performance requirements and test methods; — Part 3:
Safety and health requirements; According to the CEN-CENELEC Internal Regulations, the national standards organisations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. SIST EN 12574-2:2017
EN 12574-2:2017 (E) 4 1 Scope This part of EN 12574 specifies the test methods for stationary waste containers (in the text also called containers) according to EN 12574-1:2017. It also specifies the target requirements to be reached either during or after the tests. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 1501-1, Refuse collection vehicles and their associated lifting devices - General requirements and safety requirements - Part 1: Rear-end loaded refuse collection vehicles EN 1501-2, Refuse collection vehicles and their associated lifting devices - General requirements and safety requirements - Part 2: Side loaded refuse collection vehicles EN 1501-3:2008, Refuse collection vehicles and their associated lifting devices - General requirements and safety requirements - Part 3: Front loaded refuse collection vehicles EN 1501-5, Refuse collection vehicles - General requirements and safety requirements - Part 5: Lifting devices for refuse collection vehicles EN 10346, Continuously hot-dip coated steel flat products for cold forming - Technical delivery conditions EN 12574-1:2017, Stationary waste containers - Part 1: Containers with a capacity up to 10 000 l with flat or dome lid(s), for trunnion, double trunnion or pocket lifting device - Dimensions and design EN ISO 105-B02, Textiles - Tests for colour fastness - Part B02: Colour fastness to artificial light: Xenon arc fading lamp test (ISO 105-B02) EN ISO 1461, Hot dip galvanized coatings on fabricated iron and steel articles - Specifications and test methods (ISO 1461) EN ISO 4892-2, Plastics - Methods of exposure to laboratory light sources - Part 2: Xenon-arc lamps (ISO 4892-2) EN ISO 8256, Plastics - Determination of tensile-impact strength (ISO 8256) ISO 2081, Metallic and other inorganic coatings - Electroplated coatings of zinc with supplementary treatments on iron or steel 3 Terms and definitions For the purposes of this document, the terms and definitions given in EN 12574-1:2017 apply. SIST EN 12574-2:2017
EN 12574-2:2017 (E) 5 4 Tests 4.1 General The following tests refer to EN 12574-1:2017. Before and after the tests a visual inspection of the container shall be done for the purpose of: a) checking that the container is not damaged and has no visual defect; b) checking that the manufacturing characteristics of the container to be tested are those specified in EN 12574-1:2017; c) comparing the condition of the container before and after the sequence of tests. After completing the tests some deformation of the container is permissible, however, it shall remain entirely functional. 4.2 Control before the tests 4.2.1 Visual aspects Conformity of the container to EN 12574-1:2017, no damage, no cracks, bubbles, large flashes or sharp edges shall be present. No surface defects (unsmooth areas; trails in colour) perceivable from a distance of 1 m by a naked eye shall be visible. 4.2.2 Correspondence with EN 12574-1:2017 4.2.2.1 Components Body, lid, wheels and other fittings shall be tested in line with the relevant container standard. 4.2.2.2 Sizes and dimensions Dimensions of the containers and components shall correspond to EN 12574-1:2017. 4.2.2.3 Capacities Capacities of the container and its parts shall correspond to EN 12574-1:2017. a) For the body, by tank method (see 4.2.2.4), up to 1 700 l, and by calculation for containers over 1 700 l; b) for the lid, if possible by tank method (see 4.2.2.4), if not by calculation; c) for the container, add the results obtained in a) and b) minus any duplicated capacities. 4.2.2.4 Tank method The test equipment shall consist of a tank with sufficient capacity to receive the container to be tested. The test procedure is as follows: a) place the empty container in a tank, the container shall not be inclined; b) simultaneously fill the tank and the container with water at a temperature of (15 ± 5) °C; c) measure the quantity of water inside the container. The result of measurement shall be ± 1 % of the stated capacity of the container. SIST EN 12574-2:2017
EN 12574-2:2017 (E) 6 4.2.3 Masses limit deviations The limit deviations on the claimed container mass are ± 5 % for all materials. 4.2.4 Colour The colour shall be defined and agreed upon between customer and supplier. 4.2.5 Marking The marking of the container shall correspond to EN 12574-1:2017, Clause 10.
4.3 Control after the tests In spite of variations in deflection and sizes, it shall be possible to lift and tilt the container loaded according to 4.5 with nominal load safely on a designated lifting device and to move the container on its wheels if any. 4.4 Conditions of the tests The tests shall be carried out at the following temperatures: T1 = (23 ± 5) °C T2 =
(-180-2)°C. The minimum duration of conditioning before testing shall be 12 h. If the test is carried out outside the conditioned room and if the duration of the test is more than 5 min, then for each 5 min period of testing the container shall be reconditioned for at least 15 min before continuing the test. For special purposes a temperature lower than
« s z °C or higher than +23 °C can be agreed; in this case it shall be indicated in the test report. 4.5 Test load For the calculation of test loads either of the two following density values shall be taken: — 0,25 kg/dm3 for light waste (e.g. for plastics, plastic bottles, flasks, mixed waste); — 0,40 kg/dm3 for heavy waste (e.g. for glass, paper, organic waste, cardboard). The test load shall be the value of density as above multiplied by nominal volume and shall be HDPE granules in 25 kg bags having a specific mass of 0,5 kg/dm3 but no more than
2 500 kg. 4.6 Tests on the containers 4.6.1 General All tests shall be carried out on new containers, as per the sequence of tests in 4.10.4. 4.6.2 Impact test by ball drop The ball drop test is not compulsory for steel containers. The ability of the sensitive points such as welds and corners of the container to resist under impacts at temperature T2 shall be tested. The stationary containers shall stand on their wheels (if they are fitted) or on their supports. Ball drop test shall b
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.