SIST EN 50065-2-1:2004
(Main)Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz -- Part 2-1: Immunity requirements for mains communications equipment and systems operating in the range of frequencies 95 kHz to 148,5 kHz and intended for use in residential, commercial and light industrial environments
Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz -- Part 2-1: Immunity requirements for mains communications equipment and systems operating in the range of frequencies 95 kHz to 148,5 kHz and intended for use in residential, commercial and light industrial environments
This standard applies to electrical equipment using signals in the frequency range 95 kHz to 148,5 kHz to transmit or receive information on low voltage electrical systems, residential, commercial and light industrial environments. In the case of equipment which includes functions other than the transmission or reception of information on low voltage electrical supplies, this standard applies only to that part of the equipment intended for such transmission or reception of information. Other parts of the equipment shall comply with the immunity standard or standards relevant to the functions of those other parts. In the event of tests being specified in those other standards of a different severity and where the construction of the equipment is such that the functions cannot be tested separately, the higher severity shall apply to all affected functions.
The object of this standard is to limit mutual influence between mains communication equipment and systems (MCES) operating in different frequency bands as defined in EN 50065-1 and to contribute to ensuring Electromagnetic Compatibility in general. It specifies essential immunity requirements and test methods, including those tests which are to be performed during type-testing of MCES on low-voltage installations, for electromagnetic interference in general and more specific interference coming from other MCES. It therefore defines the immunity test requirements for apparatus in relation to continuous and transient disturbances, both conducted and radiated, and electrostatic discharges. Test requirements are specified for each port considered.
This standard gives limits which are applicable to products operating in residential, commercial and light industrial environments. The levels do not however cover extreme cases which may occur in any location but with a low probability of occurrence. In special cases situations will arise where the level of disturbances may exceed the levels specified in this standard e.g. where a hand-held transmitter is used in proximity to an apparatus. In these instances special mitigation measures may have to be employed.
It does not specify immunity between mains communication systems operating in the same band (as defined in EN 50065-1) or immunity to signals originating from Power Line Carrier systems operating on high or medium voltage networks.
Safety considerations are not included in this standard.
Signalübertragung auf elektrischen Niederspannungsnetzen im Frequenzbereich 3 kHz bis 148,5 kHz -- Teil 2-1: Störfestigkeitsanforderungen an Netz-Datenübertragungsgeräte und -systeme, die im Frequenzbereich 95 kHz bis 148,5 kHz betrieben werden und für den Gebrauch in Wohnbereichen, Geschäfts- und Gewerbebereichen sowie in Kleinbetrieben bestimmt sind
Transmission de signaux sur les réseaux électriques basse tension dans la bande de fréquences de 3 kHz à 148,5 kHz -- Partie 2-1: Exigences d'immunité pour les appareils et les systèmes de communication sur le réseau électrique dans la bande de fréquences de 95 kHz à 148,5 kHz et destinés à être utilisés dans les environnements résidentiel, commercial et de l'industrie légère
Signalizacija po nizkonapetostnih električnih napeljavah v frekvenčnem območju od 3 kHz do 148,5 kHz – 2-1. del: Zahteve za odpornost omrežne komunikacijske opreme in sistemov, ki obratujejo v frekvenčnem območju od 95 kHz do 148,5 kHz in so namenjeni za uporabo v stanovanjskih, komercialnih in lahkoindustrijskih okoljih
General Information
Relations
Standards Content (Sample)
SLOVENSKI SIST EN 50065-2-1:2004
STANDARD
marec 2004
6LJQDOL]DFLMDSRQL]NRQDSHWRVWQLKHOHNWULþQLKQDSHOMDYDKYIUHNYHQþQHP
REPRþMXRGN+]GRN+]±GHO=DKWHYH]DRGSRUQRVWRPUHåQH
NRPXQLNDFLMVNHRSUHPHLQVLVWHPRYNLREUDWXMHMRYIUHNYHQþQHPREPRþMXRG
95 kHz do 148,5 kHz in so namenjeni za uporabo v stanovanjskih,
komercialnih in lahkoindustrijskih okoljih
Signalling on low-voltage electrical installations in the frequency range 3 kHz to
148,5 kHz - Part 2-1: Immunity requirements for mains communications equipment
and systems operating in the range of frequencies 95 kHz to 148,5 kHz and
intended for use in residential, commercial and light industrial environments
ICS 5HIHUHQþQDãWHYLOND
33.040.30; 33.100.20
SIST EN 50065-2-1:2004(en)
! "#$%!&!%’()*#+’
---------------------- Page: 1 ----------------------
EUROPEAN STANDARD EN 50065-2-1
NORME EUROPÉENNE
EUROPÄISCHE NORM January 2003
ICS 33.040.30
English version
Signalling on low-voltage electrical installations
in the frequency range 3 kHz to 148,5 kHz
Part 2-1: Immunity requirements for mains communications equipment
and systems operating in the range of frequencies 95 kHz to 148,5 kHz
and intended for use in residential, commercial
and light industrial environments
Transmission de signaux sur les réseaux Signalübertragung auf elektrischen
électriques basse tension dans la bande Niederspannungsnetzen
de fréquences de 3 kHz à 148,5 kHz im Frequenzbereich 3 kHz bis 148,5 kHz
Partie 2-1: Exigences d'immunité Teil 2-1 : Störfestigkeitsanforderungen
pour les appareils et les systèmes an Netz-Datenübertragungsgeräte
de communication sur le réseau und -systeme, die im Frequenzbereich
électrique dans la bande de fréquences 95 kHz bis 148,5 kHz betrieben werden
de 95 kHz à 148,5 kHz et destinés und für den Gebrauch in Wohnbereichen,
à être utilisés dans les environnements Geschäfts- und Gewerbebereichen
résidentiel, commercial et de l'industrie sowie in Kleinbetrieben bestimmt sind
légère
This European Standard was approved by CENELEC on 2001-12-04. CENELEC members are bound to
comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and
notified to the Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Czech Republic,
Denmark, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Luxembourg, Malta,
Netherlands, Norway, Portugal, Slovakia, Spain, Sweden, Switzerland and United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Central Secretariat: rue de Stassart 35, B - 1050 Brussels
© 2003 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 50065-2-1:2003 E
---------------------- Page: 2 ----------------------
EN 50065-2-1:2003 – 2 –
Foreword
This European Standard was prepared by SC 205A, Mains communicating systems, of Technical Committee
CENELEC TC 205, Home and Building Electronic Systems (HBES).
The text of the draft was submitted to the Unique Acceptance Procedure and was approved by CENELEC as
EN 50065-2-1 on 2001-12-04.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2003-10-01
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2004-10- 01
This part of this standard defines limits and test methods for the immunity of mains communication
equipment and systems (MCES) operating in the range of frequencies from 95 kHz to 148,5 kHz and
intended for use in residential, commercial and light industrial environments. Immunity requirements
for similar equipment intended for operation in industrial environments are given in Part 2-2 of this
standard. Immunity requirements and tests applicable to Electricity Suppliers' equipment and
systems operating in the band 3 kHz to 95 kHz are given in Part 2-3.
These tests and limits represent essential electromagnetic compatibility and immunity requirements.
Correspondingly not all known disturbances have been included for testing purposes which have
been limited to those disturbances known to be critical for the operation of such equipment including
specific MCES disturbances such as conducted narrow band.
The immunity requirements have been selected to ensure an adequate level of immunity for MCES
in residential, commercial and light industrial environments. The levels do not however cover
extreme cases which may occur in any location but with an extremely low probability of occurrence.
NOTE This standard closely follows EN 50082-1, the Generic Immunity Standard for the residential, commercial and light
industrial environment, from which much of the material is taken. However the nature of MCES is such that the
performance criteria given in clause 5 of this standard differ from those given in EN 50082-1, particularly regarding the
recovery of equipment following a disturbance. For clarity and completeness all the affected sections of EN 50082-1 are
therefore repeated in this part.
Annexes designated "normative" are part of the body of the standard.
In this standard, annex A is normative.
---------------------- Page: 3 ----------------------
– 3 – EN 50065-2-1:2003
Contents
Page
1 Scope. 4
2 Normative references. 4
3 Definitions. 5
4 Description of locations . 6
5 Performance criteria. 7
6 Conditions during testing . 7
7 Immunity specifications. 7
7.1 Applicability of immunity test requirements . 7
7.2 Test specifications. 8
7.2.1 Immunity requirements. 8
7.2.2 Narrow-band conducted interference . 12
Annex A (normative) Test circuit . 14
A.1 Test circuit specification . 14
A.2 Method of testing. 15
Figure 1 - Examples of ports. 6
Figure 2 - Signal source and coupling network for narrow-band conducted interference test . 12
Figure A.1 - Test circuit. 14
Table 1 - Immunity: Enclosure port . 9
Table 2 - Immunity: Ports for signal and control lines . 9
Table 3 - Immunity: d.c. input and d.c. output power ports . 10
Table 4 - Immunity: a.c. input and a.c. output power ports . 11
Table 5 - Input a.c. power ports . 13
---------------------- Page: 4 ----------------------
EN 50065-2-1:2003 – 4 –
1 Scope
This standard applies to electrical equipment using signals in the frequency range 95 kHz to
148,5 kHz to transmit or receive information on low voltage electrical systems, residential,
commercial and light industrial environments. In the case of equipment which includes functions
other than the transmission or reception of information on low voltage electrical supplies, this
standard applies only to that part of the equipment intended for such transmission or reception of
information. Other parts of the equipment shall comply with the immunity standard or standards
relevant to the functions of those other parts. In the event of tests being specified in those other
standards of a different severity and where the construction of the equipment is such that the
functions cannot be tested separately, the higher severity shall apply to all affected functions.
The object of this standard is to limit mutual influence between mains communication equipment and
systems (MCES) operating in different frequency bands as defined in EN 50065-1 and to contribute
to ensuring Electromagnetic Compatibility in general. It specifies essential immunity requirements
and test methods, including those tests which are to be performed during type-testing of MCES on
low-voltage installations, for electromagnetic interference in general and more specific interference
coming from other MCES. It therefore defines the immunity test requirements for apparatus in
relation to continuous and transient disturbances, both conducted and radiated, and electrostatic
discharges. Test requirements are specified for each port considered.
This standard gives limits which are applicable to products operating in residential, commercial and
light industrial environments. The levels do not however cover extreme cases which may occur in
any location but with a low probability of occurrence. In special cases situations will arise where the
level of disturbances may exceed the levels specified in this standard e.g. where a hand-held
transmitter is used in proximity to an apparatus. In these instances special mitigation measures may
have to be employed.
It does not specify immunity between mains communication systems operating in the same band (as
defined in EN 50065-1) or immunity to signals originating from Power Line Carrier systems operating
on high or medium voltage networks.
Safety considerations are not included in this standard.
2 Normative references
This European Standard incorporates by dated or undated reference, provisions from other
publications. These normative references are cited at the appropriate places in the text and the
publications are listed hereafter. For dated references, subsequent amendments to or revisions of
any of these publications apply to this European Standard only when incorporated in it by
amendment or revision. For undated references the latest edition of the publication referred to
applies (including amendments).
EN 50065-1 Signalling on low voltage electrical installations in the frequency range
3 kHz to 148,5 kHz – Part 1: General requirements, frequency bands
and electromagnetic disturbances
EN 50082-1 Electromagnetic compatibility – Generic immunity standard
Part 1: Residential, commercial and light industry
EN 55022 1998 Information technology equipment – Radio disturbance characteristics -
Limits and methods of measurement
(CISPR 22:1997, mod.)
EN 61000-3-2 Electromagnetic compatibility (EMC) – Part 3-2: Limits - Limits for
harmonic current emissions (equipment input current up to and
including 16 A per phase) (IEC 61000-3-2)
---------------------- Page: 5 ----------------------
– 5 – EN 50065-2-1:2003
EN 61000-4-2 Electromagnetic compatibility (EMC) – Part 4-2: Testing and
measurement techniques – Electrostatic discharge immunity test
(IEC 61000-4-2)
EN 61000-4-3 Electromagnetic compatibility (EMC) – Part 4-3: Testing and
measurement techniques – Radiated, radio-frequency, electromagnetic
field immunity test
(IEC 61000-4-3, mod.)
EN 61000-4-4 Electromagnetic compatibility (EMC) – Part 4-4: Testing and
measurement techniques – Electrical fast transient/burst immunity test
(IEC 61000-4-4)
EN 61000-4-5 Electromagnetic compatibility (EMC) – Part 4-5: Testing and
measurement techniques – Surge immunity test (IEC 61000-4-5)
EN 61000-4-6 Electromagnetic compatibility (EMC) – Part 4-6: Testing and
measurement techniques – Immunity to conducted disturbances,
induced by radio-frequency fields
(IEC 61000-4-6)
EN 61000-4-8 Electromagnetic compatibility (EMC) – Part 4-8: Testing and
measurement techniques – Power frequency magnetic field immunity
test (IEC 61000-4-8)
EN 61000-4-11 Electromagnetic compatibility (EMC) – Part 4-11: Testing and
measurement techniques – Voltage dips, short interruptions and
voltage variations immunity tests (IEC 61000-4-11)
CISPR 16-1 1999 Specification for radio disturbance and immunity measuring apparatus
and methods – Part 1: Radio disturbance and immunity measuring
apparatus
IEC 60050-161 International Electrotechnical Vocabulary – Chapter 161:
Electromagnetic compatibility
3 Definitions
For the purpose of this standard, the following definitions together with those in IEC 60050-161
apply.
3.1
electromagnetic interference
See definition given in IEC 60050-161.
3.2
immunity
the ability of MCES to perform within specified limits in the presence of an electromagnetic
disturbance
NOTE 1 Influences between MCES operating in the same frequency band (see EN 50065-1) are not taken into account.
NOTE 2 See IEC 60050 Chapter 161 for a more general definition.
3.3
immunity level
the maximum level of a given electromagnetic disturbance incident on the equipment for which it
remains capable of operating at a specified degree of performance
(Definition given in IEV 60050-161)
---------------------- Page: 6 ----------------------
EN 50065-2-1:2003 – 6 –
3.4
port
particular interface of the specified accessory with the external electromagnetic environment (see
Figure 1)
3.5
cable port
a point at which a conductor or a cable is connected to the accessory. Examples are signal, control
and power ports
3.6
enclosure port
the physical boundary of the accessory through which electromagnetic fields may radiate or impinge
3.7
public mains network
electricity lines to which all categories of consumers have access and which are operated by a
supply or distribution undertaking for the purpose of supplying electrical energy
3.8
severity level
value of an influencing electromagnetic quantity specified for an immunity test
Enclosure port
AC power port Signal/control port
APPARATUS
DC power port Earth port
Figure 1 - Examples of ports
4 Description of locations
The environments encompassed by this standard are residential, commercial and light-industrial
locations, both indoor and outdoor. The following list, although not comprehensive, gives an
indication of locations which are included:
• residential properties, e.g. houses, apartments,
• retail outlets, e.g. shops, supermarkets,
• business premises, e.g. offices, banks,
• areas of public entertainment, e.g. cinemas, public bars, dance halls,
• outdoor locations, e.g. petrol stations, car parks, amusement and sports centres,
...