Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz -- Part 2-2: Immunity requirements for mains communications equipment and systems operating in the range of frequencies 95 kHz to 148,5 kHz and intended for use in industrial environments

Corrigendum to EN issued October 2006

Signalübertragung auf elektrischen Niederspannungsnetzen im Frequenzbereich 3 kHz bis 148,5 kHz -- Teil 2-2: Störfestigkeitsanforderungen an Netz-Datenübertragungsgeräte und -systeme, die im Frequenzbereich 95 kHz bis 148,5 kHz betrieben werden und für den Gebrauch im Industriebereich bestimmt sind

Transmission de signaux sur les réseaux électriques basse tension dans la bande de fréquences de 3 kHz à 148,5 kHz -- Partie 2-2: Exigences d'immunité pour les appareils et les systèmes de communication sur le réseau électrique dans la bande de fréquences de 95 kHz à 148,5 kHz et destinés à être utilisés dans un environnement industriel

Signalizacija po nizkonapetostnih električnih napeljavah v frekvenčnem območju od 3 kHz do 148,5 kHz – 2-2. del: Zahteve za odpornost omrežne komunikacijske opreme in sistemov, ki obratujejo v frekvenčnem območju od 95 kHz do 148,5 kHz in so namenjeni za uporabo v industrijskih okoljih

General Information

Status
Published
Publication Date
31-Dec-2005
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
01-Jan-2006
Due Date
01-Jan-2006
Completion Date
01-Jan-2006

Relations

Effective Date
21-Sep-2010

Overview

EN 50065-2-2:2003/A1:2005 (with Corrigendum October 2006) is a CENELEC / CLC amendment specifying immunity requirements for mains communications equipment and systems operating in the frequency band 95 kHz to 148.5 kHz on low-voltage electrical installations, intended for use in industrial environments. It focuses on electromagnetic compatibility (EMC) and aims to limit mutual influence between mains communication systems (as defined in EN 50065-1). This copy incorporates amendment A1 and the October 2006 corrigendum; the record indicates a 2021 legacy conversion by DCLab NISOSTS.

Key Topics

  • Scope and applicability
    • Applies only to the communication portion of multi-function equipment; other functions must meet their relevant immunity standards.
    • Excludes safety requirements and immunity between systems operating in the same EN 50065-1 band or PLC on medium/high voltage networks.
  • Immunity types and test methods
    • Defines immunity to continuous and transient disturbances: conducted and radiated interference, electrostatic discharge (ESD), fast transients and surge events.
    • Test requirements are specified per port (enclosure, signal/control ports, DC and AC power ports, earth/functional ground).
  • Notable amendments and limits (selected)
    • Enclosure port radiated field level revised from 3 V/m to 10 V/m and magnetic field from 3 A/m to 30 A/m.
    • Signal/control line ESD increased from ±0.5 kV to ±1 kV (both common and differential mode).
    • AC power port test level changed from 3 V to 10 V; surge levels adjusted (e.g., common mode reduced from ±4 kV to ±2 kV, differential to ±1 kV).
    • New Table 5 added for Earth port (functional ground) immunity: RF common-mode 0.15–80 MHz at 3 V, and fast transients ±0.5 kV under specified conditions.
    • Normative reference updates: replace EN 50082-2 with EN 61000-6-2; update EN 50065-1 references.
  • Notes and exceptions
    • Special provisions for ITU broadcast bands (87–108 MHz and 470–790 MHz) where specified field levels differ.
    • Levels are tailored to industrial environments and do not cover extremely rare high-disturbance scenarios.

Applications

  • Manufacturers of mains communication devices and PLC (power line communication) modules for industrial automation.
  • EMC test laboratories validating compliance of equipment operating 95–148.5 kHz.
  • Design and compliance engineers in utilities, industrial control systems, building automation, and system integrators ensuring robust PLC performance on low-voltage networks.
  • Regulatory and certification bodies referencing immunity limits for industrial mains signalling equipment.

Related Standards

  • EN 50065-1 (band definitions and general rules for signalling on low-voltage installations)
  • EN 61000-6-2 (industrial immunity standard)
  • CISPR 16-1 (measurement methods – referenced in the original standard)

Keywords: EN 50065-2-2, mains communications, power line communication, PLC, immunity requirements, EMC testing, industrial environments, low-voltage electrical installations, 95 kHz to 148.5 kHz.

Amendment

SIST EN 50065-2-2:2004/A1:2006

English language
6 pages
Preview
Preview
e-Library read for
1 day

Frequently Asked Questions

SIST EN 50065-2-2:2004/A1:2006 is a amendment published by the Slovenian Institute for Standardization (SIST). Its full title is "Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz -- Part 2-2: Immunity requirements for mains communications equipment and systems operating in the range of frequencies 95 kHz to 148,5 kHz and intended for use in industrial environments". This standard covers: Corrigendum to EN issued October 2006

Corrigendum to EN issued October 2006

SIST EN 50065-2-2:2004/A1:2006 is classified under the following ICS (International Classification for Standards) categories: 33.040.30 - Switching and signalling systems; 33.100.20 - Immunity. The ICS classification helps identify the subject area and facilitates finding related standards.

SIST EN 50065-2-2:2004/A1:2006 has the following relationships with other standards: It is inter standard links to SIST EN 50065-2-2:2004. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

SIST EN 50065-2-2:2004/A1:2006 is associated with the following European legislation: EU Directives/Regulations: 2004/108/EC, 2004/108/EU, 2014/30/EU, 89/336/EEC; Standardization Mandates: M/404. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

You can purchase SIST EN 50065-2-2:2004/A1:2006 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of SIST standards.

Standards Content (Sample)


SLOVENSKI SIST EN 50065-2-
2:2004/A1:2006
STANDARD
januar 2006
6LJQDOL]DFLMDSRQL]NRQDSHWRVWQLKHOHNWULþQLKQDSHOMDYDKYIUHNYHQþQHP
REPRþMXRGN+]GRN+]±GHO=DKWHYH]DRGSRUQRVWRPUHåQH
NRPXQLNDFLMVNHRSUHPHLQVLVWHPRYNLREUDWXMHMRYIUHNYHQþQHPREPRþMXRG
95 kHz do 148,5 kHz in so namenjeni za uporabo v industrijskih okoljih
(istoveten EN 50065-2-2:2003/A1:2005)
Signalling on low-voltage electrical installations in the frequency range 3 kHz to
148,5 kHz - Part 2-2: Immunity requirements for mains communications equipment
and systems operating in the range of frequencies 95 kHz to 148,5 kHz and
intended for use in industrial environments
ICS 5HIHUHQþQDãWHYLOND
33.040.30; 33.100.20
! "#$%!&!%’()*#+’
EUROPEAN STANDARD EN 50065-2-2/A1
NORME EUROPÉENNE
EUROPÄISCHE NORM September 2005

ICS 33.040.30 Incorporates Corrigendum October 2006

English version
Signalling on low-voltage electrical installations
in the frequency range 3 kHz to 148,5 kHz
Part 2-2: Immunity requirements for mains communications equipment
and systems operating in the range of frequencies 95 kHz to 148,5 kHz
and intended for use in industrial environments

Transmission de signaux sur les réseaux Signalübertragung auf elektrischen
électriques basse tension dans la bande Niederspannungsnetzen im
de fréquences de 3 kHz à 148,5 kHz Frequenzbereich 3 kHz bis 148,5 kHz
Partie 2-2: Exigences d'immunité pour Teil 2-2: Störfestigkeitsanforderungen an
les appareils et les systèmes de Netz-Datenübertragungsgeräte und -
communication sur le réseau électrique systeme, die im Frequenzbereich 95 kHz
dans la bande de fréquences de 95 kHz bis 148,5 kHz betrieben werden und für
à 148,5 kHz et destinés à être utilisés den Gebrauch im Industriebereich
dans un environnement industriel bestimmt sind

This amendment A1 modifies the European Standard EN 50065-2-2:2003; it was approved by CENELEC
on 2005-07-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations
which stipulate the conditions for giving this amendment the status of a national standard without any
alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This amendment exists in three official versions (English, French, German). A version in any other language
made by translation under the responsibility of a CENELEC member into its own language and notified to the
Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Cyprus, Czech
Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden,
Switzerland and United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Central Secretariat: rue de Stassart 35, B - 1050 Brussels

© 2005 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.

Ref. No. EN 50065-2-2:2003/A1:2005 E

Foreword
This amendment to the European Standard EN 50065-2-2:2003 was prepared by SC 205A, Mains
communicating systems, of Technical Committee CENELEC TC 205, Home and Building Electronic
Systems (HBES).
The text of the draft was submitted to the Unique Acceptance Procedure and was approved by
CENELEC as amendment A1 to EN 50065-2-2:2003 on 2005-07-01.
The following dates were fixed:
– latest date by which the amendment has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2006-07-01
– latest date by which the national standards conflicting
with the amendment have to be withdrawn (dow) 2008-07-01
The contents of the corrigendum of October 2006 have been included in this copy.
__________
- 3 - EN 50065-2-2:2003/A1:2005
1 Scope
This standard applies to electrical equipment using signals in the frequency range 95 kHz to
148,5 kHz to transmit or receive information on low voltage electrical systems, in industrial
environments. In the case of equipment which includes functions other than the transmission or
reception of information on low voltage electrical supplies, this standard applies only to that part of the
equipment intended for such transmission or reception of information. Other parts of the equipment
shall comply with the immunity standard or standards relevant to the functions of those other parts. In
the event of tests being specified in those other standards of a different severity and where the
construction of the equipment is such that the functions cannot be tested separately, the higher
seve
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...