SIST EN 50121-3-2:2015
(Main)Railway applications - Electromagnetic compatibility - Part 3-2: Rolling stock - Apparatus
Railway applications - Electromagnetic compatibility - Part 3-2: Rolling stock - Apparatus
This European Standard applies to emission and immunity aspects of EMC for electrical and electronic
apparatus intended for use on railway rolling stock. EN 50121-3-2 applies for the integration of
apparatus on rolling stock.
The frequency range considered is from DC to 400 GHz. No measurements need to be performed at
frequencies where no requirement is specified.
The application of tests shall depend on the particular apparatus, its configuration, its ports, its
technology and its operating conditions.
This standard takes into account the internal environment of the railway rolling stock and the external
environment of the railway, and interference to the apparatus from equipment such as hand-held radiotransmitters.
If a port is intended to transmit or receive for the purpose of radio communication (intentional radiators,
e.g. transponder systems), then the radiated emission requirement in this standard is not intended to
be applicable to the intentional transmission from a radio-transmitter as defined by the ITU.
Immunity limits do not apply in the exclusion bands as defined in the corresponding EMC related
standard for radio equipment.
This standard does not apply to transient emissions when starting or stopping the apparatus.
The objective of this standard is to define limits and test methods for electromagnetic emissions and
immunity test requirements in relation to conducted and radiated disturbances.
These limits and tests represent essential electromagnetic compatibility requirements.
Emission requirements have been selected so as to ensure that disturbances generated by the
apparatus operated normally on railway rolling stock do not exceed a level which could prevent other
apparatus from operating as intended. The emission limits given in this standard take precedence over
emission requirements for individual apparatus on board the rolling stock given in other standards.
Likewise, the immunity requirements have been selected so as to ensure an adequate level of
immunity for rolling stock apparatus.
The levels do not however cover all cases which may occur with an extremely low probability of
occurrence in any location. Specific requirements which deviate from this standard shall be specified.
Test requirements are specified for each port considered.
These specific provisions are to be used in conjunction with the general provisions in EN 50121-1.
Bahnanwendungen - Elektromagnetische Verträglichkeit - Teil 3-2: Bahnfahrzeuge - Geräte
Diese Europäische Norm legt Anforderungen zur EMV – Störaussendung und Störfestigkeit – für elektrische und elektronische Geräte fest, die zur Verwendung an Bord von Bahnfahrzeugen vorgese¬hen sind. Sie gilt für den Einbau von Geräten in Bahnfahrzeuge.
Der betrachtete Frequenzbereich reicht von 0 Hz bis 400 GHz. Für Frequenzen, für die keine Anforde-rungen festgelegt sind, brauchen keine Messungen durchgeführt zu werden.
Die Anwendung von Prüfungen muss von dem betreffenden Gerät, seiner Anordnung, seinen Anschlüssen, seiner Technologie und seinen Betriebsbedingungen abhängig gemacht werden.
Diese Norm berücksichtigt die internen Umgebungsbedingungen in Bahnfahrzeugen und die äußere Bahnumgebung sowie Störeinflüsse auf Geräte durch Ausrüstungen wie z. B. Handsprechfunkgeräte.
Wenn ein Anschluss dafür vorgesehen ist, Sende- oder Empfangsfunktionen für den Zweck der Funk-kommunikation auszuführen (Sendefunkgeräte, z. B. Transponder-Systeme), sind die Anforderungen dieser Norm an die gestrahlte Störaussendung nicht dafür vorgesehen, auf die Funkkommunikation eines Sende¬funkgerätes, wie sie von der ITU definiert ist, Anwendung zu finden.
Die Grenzwerte der Störfestigkeit gelten nicht in den ausgenommenen Frequenzbereichen (Ausschluss-bändern), wie in den korrespondierenden auf die EMV bezogenen Normen für Funkgeräte beschrieben.
Diese Norm gilt nicht für die kurzzeitige bzw. impulsförmige Störaussendungen (Transiente) beim Ein- oder Ausschalten des Geräts.
Zweck dieser Norm ist die Festlegung von Grenzwerten und Messverfahren für elektromagnetische Stör-aussendungen und von Prüfanforderungen zur Störfestigkeit bezogen auf leitungsgeführte und gestrahlte Störgrößen.
Diese Grenzwerte und Prüfungen stellen wesentliche Anforderungen zur Elektromagnetischen Verträglichkeit dar.
Die Anforderungen zur Störaussendung wurden so ausgewählt, dass die von Geräten, die an Bord von Bahnfahrzeugen bestimmungsgemäß betrieben werden, erzeugten Störgrößen keinen Pegel überschreiten, mit dem andere Geräte (Betriebsmittel, Einrichtungen) daran gehindert werden, wie beabsichtigt zu arbeiten. Die in dieser Norm angegebenen Grenzwerte der Störaussendung haben Vorrang gegenüber Anforderungen der Störaussendung an einzelne Geräte in Bahnfahrzeugen, die in anderen Normen angegeben werden.
Entsprechend wurden die Anforderungen zur Störfestigkeit so ausgewählt, dass für Geräte in Bahn¬fahr-zeugen eine angemessener Störfestigkeitspegel sichergestellt ist.
Die Prüfpegel decken jedoch nicht extreme Fälle ab, die an jedem Betriebsort mit sehr geringer Wahr-scheinlichkeit auftreten können. Besondere Anforderungen, die von dieser Norm abweichen, müssen festgelegt werden.
Prüfanforderungen sind für jeden betrachteten Anschluss festgelegt.
Diese besonderen Festlegungen müssen in Verbindung mit den allgemeinen Festlegungen der EN 50121-1 angewendet werden.
Applications ferroviaires - Compatibilité électromagnétique - Partie 3-2: Matériel roulant - Appareils
La présente Norme Européenne s’applique aux aspects d’émission et d’immunité de CEM des appareils électriques et électroniques destinés à être utilisés à bord du matériel roulant ferroviaire. L'EN 50121 3 2 s’applique pour l’intégration des appareils à bord du matériel roulant.
La plage de fréquences concernée va du courant continu à 400 GHz. Aucune mesure n’est nécessaire aux fréquences pour lesquelles aucune exigence n’est spécifiée.
L’application des essais doit dépendre des appareils eux-mêmes, de leur configuration, de leurs accès, de leur technologie et de leurs conditions de fonctionnement.
La présente Norme prend en compte l’environnement interne du matériel roulant ferroviaire et l'environnement externe du système ferroviaire, ainsi que les perturbations affectant les appareils provenant d'équipements tels que les émetteurs radioélectriques portables.
Si un accès est destiné à émettre ou recevoir des communications radio (émetteurs intentionnels de rayonnement, par exemple, systèmes de balise), alors les exigences relatives aux émissions rayonnées de la présente Norme ne s'appliquent pas à la transmission intentionnelle à partir d'un émetteur radio tel que défini par l'UIT.
Les limites d'immunité ne s'appliquent pas dans les bandes d'exclusion telles que définies dans la norme CEM correspondante pour les équipements radio.
La présente Norme ne s’applique pas aux émissions de transitoires lors du démarrage ou de l'arrêt des appareils.
L’objectif de la présente Norme est de définir les limites et les méthodes d’essai concernant les émissions électromagnétiques et les exigences relatives aux essais d’immunité en matière de perturbations conduites et rayonnées.
Ces limites et ces essais représentent les exigences essentielles de compatibilité électromagnétique.
Les exigences relatives aux émissions ont été choisies pour assurer que les perturbations générées par l’appareil qui fonctionne normalement à bord du matériel roulant ferroviaire ne dépassent pas un niveau qui pourrait empêcher d’autres appareils de fonctionner comme prévu. Les limites d'émission données dans la présente Norme l'emportent sur les exigences relatives aux émissions des appareillages individuels embarqués sur le matériel roulant données dans les autres normes.
De la même manière, les exigences relatives à l'immunité ont été choisies pour assurer un niveau approprié d’immunité pour les appareils du matériel roulant.
Les niveaux ne couvrent cependant pas tous les cas qui peuvent apparaître avec une très faible probabilité en tout emplacement. Les exigences particulières qui s’écartent de la présente Norme doivent être spécifiées.
Les exigences relatives aux essais sont spécifiées pour chaque accès considéré.
Ces dispositions spécifiques doivent être utilisées avec les dispositions générales données dans l'EN 50121 1.
Železniške naprave - Elektromagnetna združljivost - 3-2. del: Vozna sredstva - Naprave
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
SIST EN 50121-3-2:2015
01-julij-2015
Železniške naprave - Elektromagnetna združljivost - 3-2. del: Vozna sredstva -
Naprave
Railway applications - Electromagnetic compatibility - Part 3-2: Rolling stock - Apparatus
Bahnanwendungen - Elektromagnetische Verträglichkeit - Teil 3-2: Bahnfahrzeuge -
Geräte
Applications ferroviaires - Compatibilité électromagnétique - Partie 3-2: Matériel roulant -
Appareils
Ta slovenski standard je istoveten z: EN 50121-3-2:2015
ICS:
33.100.01 Elektromagnetna združljivost Electromagnetic compatibility
na splošno in general
45.060.01 Železniška vozila na splošno Railway rolling stock in
general
SIST EN 50121-3-2:2015 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
SIST EN 50121-3-2:2015
---------------------- Page: 2 ----------------------
SIST EN 50121-3-2:2015
EUROPEAN STANDARD
EN 50121-3-2
NORME EUROPÉENNE
EUROPÄISCHE NORM
March 2015
ICS 33.100.01; 45.060.01 Supersedes EN 50121-3-2:2006
English Version
Railway applications - Electromagnetic compatibility - Part 3-2:
Rolling stock - Apparatus
Applications ferroviaires - Compatibilité électromagnétique - Bahnanwendungen - Elektromagnetische Verträglichkeit -
Partie 3-2: Matériel roulant - Appareils Teil 3-2: Bahnfahrzeuge - Geräte
This European Standard was approved by CENELEC on 2015-01-05. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any
alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2015 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN 50121-3-2:2015 E
---------------------- Page: 3 ----------------------
SIST EN 50121-3-2:2015
EN 50121-3-2:2015 - 2 -
Contents
Foreword . 3
1 Scope . 4
2 Normative references . 4
3 Terms, definitions and abbreviations . 5
4 Performance criteria . 6
5 Conditions during testing . 6
6 Applicability . 7
7 Emission tests and limits . 7
8 Immunity tests and limits . 12
Annex A (informative) Examples of apparatus and ports . 17
Annex B (informative) Conducted disturbances generated by power converters . 23
Annex ZZ (informative) Coverage of Essential Requirements of EU Directives . 24
---------------------- Page: 4 ----------------------
SIST EN 50121-3-2:2015
- 3 - EN 50121-3-2:2015
Foreword
This document (EN 50121-3-2:2015) has been prepared by CLC/TC 9X: “Electrical and electronic
applications for railways”.
The following dates are fixed:
• latest date by which this document has to be (dop) 2016-01-05
implemented at national level by publication of
an identical national standard or by
endorsement
• latest date by which the national standards (dow) 2018-01-05
conflicting with this document have to
be withdrawn
This document supersedes EN 50121-3-2:2006.
EN 50121-3-2:2015 includes the following significant technical changes with respect to
EN 50121-3-2:2006:
- clarification of scope (Clause 1);
- set dated normative references (Clause 2);
- new definition of ports and clarification in Tables 1 to 6;
- emission requirement extended in the frequency range 1 GHz to 6 GHz following EN 61000-6-4;
- immunity requirement extended in the frequency range 5,1 GHz to 6 GHz;
- revision of Annex B.
This European Standard is to be read in conjunction with EN 50121-1.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such
patent rights.
This document has been prepared under a mandate given to CENELEC by the European Commission
and the European Free Trade Association, and supports essential requirements of EU Directive(s).
For the relationship with EU Directive(s) see informative Annex ZZ, which is an integral part of this
document.
This standard forms Part 3-2 of the European Standard series EN 50121, published under the general
title “Railway applications - Electromagnetic compatibility”. The series consists of:
− Part 1: General
− Part 2: Emission of the whole railway system to the outside world
− Part 3-1: Rolling stock - Train and complete vehicle
− Part 3-2: Rolling stock - Apparatus
− Part 4: Emission and immunity of the signalling and telecommunications apparatus
− Part 5: Emission and immunity of fixed power supply installations and apparatus
---------------------- Page: 5 ----------------------
SIST EN 50121-3-2:2015
EN 50121-3-2:2015 - 4 -
1 Scope
This European Standard applies to emission and immunity aspects of EMC for electrical and electronic
apparatus intended for use on railway rolling stock. EN 50121-3-2 applies for the integration of
apparatus on rolling stock.
The frequency range considered is from DC to 400 GHz. No measurements need to be performed at
frequencies where no requirement is specified.
The application of tests shall depend on the particular apparatus, its configuration, its ports, its
technology and its operating conditions.
This standard takes into account the internal environment of the railway rolling stock and the external
environment of the railway, and interference to the apparatus from equipment such as hand-held radio-
transmitters.
If a port is intended to transmit or receive for the purpose of radio communication (intentional radiators,
e.g. transponder systems), then the radiated emission requirement in this standard is not intended to
be applicable to the intentional transmission from a radio-transmitter as defined by the ITU.
Immunity limits do not apply in the exclusion bands as defined in the corresponding EMC related
standard for radio equipment.
This standard does not apply to transient emissions when starting or stopping the apparatus.
The objective of this standard is to define limits and test methods for electromagnetic emissions and
immunity test requirements in relation to conducted and radiated disturbances.
These limits and tests represent essential electromagnetic compatibility requirements.
Emission requirements have been selected so as to ensure that disturbances generated by the
apparatus operated normally on railway rolling stock do not exceed a level which could prevent other
apparatus from operating as intended. The emission limits given in this standard take precedence over
emission requirements for individual apparatus on board the rolling stock given in other standards.
Likewise, the immunity requirements have been selected so as to ensure an adequate level of
immunity for rolling stock apparatus.
The levels do not however cover all cases which may occur with an extremely low probability of
occurrence in any location. Specific requirements which deviate from this standard shall be specified.
Test requirements are specified for each port considered.
These specific provisions are to be used in conjunction with the general provisions in EN 50121-1.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.
EN 50121-1:2015, Railway applications - Electromagnetic compatibility - Part 1: General
EN 50121-3-1:2015, Railway applications - Electromagnetic compatibility - Part 3-1: Rolling stock -
Train and complete vehicle
---------------------- Page: 6 ----------------------
SIST EN 50121-3-2:2015
- 5 - EN 50121-3-2:2015
EN 50155:2007, Railway applications - Electronic equipment used on rolling stock
EN 55016-1-1:2010, Specification for radio disturbance and immunity measuring apparatus and
methods - Part 1-1: Radio disturbance and immunity measuring apparatus - Measuring apparatus
(CISPR 16-1-1:2010)
EN 55016-1-4:2010, Specification for radio disturbance and immunity measuring apparatus and
methods - Part 1-4: Radio disturbance and immunity measuring apparatus - Antennas and test sites for
radiated disturbance measurements (CISPR 16-1-4:2010)
EN 55016-2-1:2009, Specification for radio disturbance and immunity measuring apparatus and
methods - Part 2-1: Methods of measurement of disturbances and immunity - Conducted disturbance
measurements (CISPR 16-2-1:2008)
EN 55016-2-3:2010, Specification for radio disturbance and immunity measuring apparatus and
methods - Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance
measurements (CISPR 16-2-3:2010)
EN 55022:2010, Information technology equipment - Radio disturbance characteristics - Limits and
methods of measurement (CISPR 22:2008, mod.)
EN 61000-4-2:2009, Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement
techniques - Electrostatic discharge immunity test (IEC 61000-4-2:2008)
EN 61000-4-3:2006, Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement
techniques - Radiated, radio-frequency, electromagnetic field immunity test (IEC 61000-4-3:2006)
EN 61000-4-4:2004, Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement
techniques - Electrical fast transient/burst immunity test (IEC 61000-4-4:2004)
EN 61000-4-5:2006, Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement
techniques - Surge immunity test (IEC 61000-4-5:2005)
EN 61000-4-6:2009, Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement
techniques - Immunity to conducted disturbances, induced by radio-frequency fields (IEC 61000-4-
6:2008)
EN 61000-4-30:2009, Electromagnetic compatibility (EMC) - Part 4-30: Testing and measurement
techniques - Power quality measurement methods (IEC 61000-4-30:2008)
EN 61000-6-4:2007, Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission
standard for industrial environments (IEC 61000-6-4:2006)
3 Terms, definitions and abbreviations
3.1 Terms and definitions
For the purposes of this document, the following terms and definitions apply
3.1.1
rolling stock apparatus
a finished product with an intrinsic function intended for implementation into the rolling stock installation
3.1.2
port
the particular interface of the specified apparatus with the external environment e.g. auxiliary AC or DC
power port, I/O (input/output) port
---------------------- Page: 7 ----------------------
SIST EN 50121-3-2:2015
EN 50121-3-2:2015 - 6 -
3.1.3
enclosure port
the physical boundary of the apparatus through which electromagnetic fields may radiate or impinge
The main categories of ports for rolling stock apparatus are presented in Figure 1.
Enclosure port
Signal & communication
Auxiliary AC or DC
ROLLING
STOCK
t
Process measurement &
APPARATUS
Battery power supply
l
Figure 1 – Main categories of ports
Typical examples of rolling stock apparatus with their ports are listed in Annex A.
Traction power ports are not covered in EN 50121-3-2:2015, see Annex B.
3.2 Abbreviations
a.c. Alternating current
AM Amplitude modulation
CISPR Comité international spécial des perturbations radioélectriques
d.c. Direct current
EMC Electromagnetic compatibility
EUT Equipment under test
I/O Input / Output
ITU International Telegraph Union
OATS Open area test site
PC Personal computer
SAC Semi-anechoic chamber
THD Total harmonic distortion
TV Television
4 Performance criteria
The variety and the diversity of the apparatus within the scope of this standard make it difficult to define
precise criteria for the evaluation of the immunity test results.
A functional description and a definition of performance criteria, during or as a consequence of the
EMC testing, shall be provided by the manufacturer and noted in the test report, based on the criteria
A, B, C defined in EN 50121-1:2015.
5 Conditions during testing
It is not always possible to test every function of the apparatus. The tests shall be made at a typical
operating mode considered by the manufacturer to produce the largest emission or maximum
---------------------- Page: 8 ----------------------
SIST EN 50121-3-2:2015
- 7 - EN 50121-3-2:2015
susceptibility to noise as appropriate in the frequency band being investigated consistent with normal
applications. The conditions during testing shall be defined in a test plan (see basic standard of
EN 61000-4-x series).
If the apparatus is part of a system, or can be connected to auxiliary apparatus, then the apparatus
shall be tested while connected to the minimum configuration of auxiliary apparatus necessary to
exercise the ports in accordance e.g. with EN 55022:2010, Clause 8.
The configuration and mode of operation shall be specified in the test plan and the actual conditions,
during the tests, shall be precisely noted in the test report.
If the apparatus has a large number of similar ports or ports with many similar connections, then a
sufficient number shall be selected to simulate actual operating conditions and to ensure that all the
different types of termination are covered (e.g. 20 % of the ports or at least four ports).
The tests shall be carried out within the specified operating range for the apparatus and at its nominal
supply voltage, unless otherwise indicated.
6 Applicability
The measurements in this standard shall be made on the relevant ports of the apparatus.
It may be determined from consideration of the electrical characteristics, the connection and the usage
of a particular apparatus that some of the tests are not applicable (e.g. radiated immunity of induction
motors, transformers). In such cases, the decision not to test has to be recorded in the test plan and
test report.
If not otherwise specified, the EMC tests shall be type tests.
7 Emission tests and limits
The emission tests and limits for apparatus covered by this standard are given on a port by port basis.
Measurements shall be performed in well-defined and reproducible conditions for each type of
disturbance.
The description of the test, the test methods and the test set-up are given in Basic Standards which
are referred to in Tables 1 to 3.
The contents of these Basic Standards are not repeated here, however modifications or additional
information needed for the practical application of the tests are given in this standard.
NOTE The reference to “Basic Standard“ is intended to be limited to those parts of the standard that give the
description of the test, the test methods and the test set-up.
---------------------- Page: 9 ----------------------
SIST EN 50121-3-2:2015
EN 50121-3-2:2015 - 8 -
Table 1 – Emission – Auxiliary AC or DC power ports (input and output)
Test Basic Test set- Applicabili
Port Remarks
specification Standard up ty note
1.1 Auxiliary supply 150 kHz to 500 kHz 99 dBμV quasi- EN 55016–2- EN 55016– See a, b For the time being there are no limits
peak 1 2-1 and c for shore supply mode. Therefore the
sinusoidal AC or DC
limits given in this table are valid.
(port 9 on Figures A.1,
500 kHz to 30 MHz 93 dBμV quasi-
Other limits may apply if connected
A.2 and A.4)
peak
e.g. to the public low voltage power
supply and should be specified by
the train operator.
1.2 AC power outlet port 50 Hz to 2 kHz THD < 8 % EN 61000–4- 230 V AC power outlet ports for
30 public use shall offer a power quality,
for public use
(THD: total
which is sufficient for the use of
harmonic
intended equipment like PC and
distortion)
mobile telephone chargers. The
harmonic distortion in differential
mode shall be limited by a sine-filter
to < 8 %.
a Wherever applicable the method defined by EN 55016–2-1 is to be used. At present the existing method of measuring conducted emissions (EN 55016–2-1) has
limitations in terms of voltage and current rating of coupling networks. In addition the method of measuring voltage has safety impl
...
SLOVENSKI STANDARD
oSIST prEN 50121-3-2:2014
01-januar-2014
1DGRPHãþD
SIST EN 50121-3-2:2007
Železniške naprave - Elektromagnetna združljivost - 3-2. del: Vozna sredstva -
Naprave
Railway applications - Electromagnetic compatibility - Part 3-2: Rolling stock - Apparatus
Bahnanwendungen - Elektromagnetische Verträglichkeit - Teil 3-2: Bahnfahrzeuge -
Geräte
Applications ferroviaires - Compatibilité électromagnétique - Partie 3-2: Matériel roulant -
Appareils
Ta slovenski standard je istoveten z: prEN 50121-3-2:2013
ICS:
33.100.01 Elektromagnetna združljivost Electromagnetic compatibility
na splošno in general
45.060.01 Železniška vozila na splošno Railway rolling stock in
general
oSIST prEN 50121-3-2:2014 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
oSIST prEN 50121-3-2:2014
---------------------- Page: 2 ----------------------
oSIST prEN 50121-3-2:2014
DRAFT
EUROPEAN STANDARD
prEN 50121-3-2
NORME EUROPÉENNE
September 2013
EUROPÄISCHE NORM
ICS Will supersede EN 50121-3-2:2006
English version
Railway applications -
Electromagnetic compatibility -
Part 3-2: Rolling stock -
Apparatus
Applications ferroviaires - Bahnanwendungen -
Compatibilité électromagnétique - Elektromagnetische Verträglichkeit -
Partie 3-2: Matériel roulant - Teil 3-2: Bahnfahrzeuge -
Appareils Geräte
This draft European Standard is submitted to CENELEC members for CENELEC enquiry.
Deadline for CENELEC: 2014-02-28.
It has been drawn up by CLC/TC 9X.
If this draft becomes a European Standard, CENELEC members are bound to comply with the CEN/CENELEC Internal
Regulations which stipulate the conditions for giving this European Standard the status of a national standard without
any alteration.
This draft European Standard was established by CENELEC in three official versions (English, French, German). A
version in any other language made by translation under the responsibility of a CENELEC member into its own
language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the
Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece,
Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal,
Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.
Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they
are aware and to provide supporting documentation.
Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change
without notice and shall not be referred to as a European Standard.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Avenue Marnix 17, B - 1000 Brussels
© 2013 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Project: 23683 Ref. No. prEN 50121-3-2:2013 E
---------------------- Page: 3 ----------------------
oSIST prEN 50121-3-2:2014
prEN 50121-3-2:2013 (E)
1 Contents Page
2 Foreword . 4
3 1 Scope . 5
4 2 Normative references . 6
5 3 Terms, definitions and abbreviations . 7
6 3.1 Terms and definitions . 7
7 3.2 Abbreviations . 7
8 4 Performance criteria . 8
9 5 Conditions during testing . 8
10 6 Applicability . 8
11 7 Emission tests and limits . 9
12 8 Immunity tests and limits . 13
13 Annex A (informative) Examples of apparatus and ports . 17
14 Annex B (informative) Conducted disturbances generated by power converters . 22
15 Annex ZZ (informative) Coverage of Essential Requirements of EU Directives . 23
16 Bibliography . 24
17
18 Figure 1 – Main categories of ports . 7
19 Figure A.1 – AC fed loco with AC traction drive and psophometric filter on the line side . 19
20 Figure A.2 – AC/AC system with power factor correction filter on the converter side and with DC or three-
21 phase auxiliary and train power supply. 19
22 Figure A.3 – Conventional system with AC input and DC traction motors fed by phase control converter . 20
23 Figure A.4 – DC fed system with AC traction drive . 20
24 Figure A.5 – Additional ports of converter and control electronics . 21
25 Figure B.1 – Test set-up . 22
2
---------------------- Page: 4 ----------------------
oSIST prEN 50121-3-2:2014
prEN 50121-3-2:2013 (E)
26
27 Table 1 – Emission – Auxiliary AC or DC power ports (input and output) . 10
28 Table 2 – Emission – Battery power supply (Input and output) . 10
29 Table 3 – Emission – Enclosure port . 11
30 Table 4 – Immunity – Battery referenced ports (except at the output of energy sources), auxiliary AC
31 power input ports (rated voltage ≤ 400 Vrms) . 14
32 Table 5 – Immunity – Signal & communication, process measurement & control ports . 15
33 Table 6 – Immunity – Enclosure ports . 16
34 Table A.1 – Typical examples of apparatus . 17
35 Table A.2 – Typical port descriptions . 18
36 Table B.1 – Emission requirements for AC and DC power ports . 22
37
38
3
---------------------- Page: 5 ----------------------
oSIST prEN 50121-3-2:2014
prEN 50121-3-2:2013 (E)
39 Foreword
40 This document [prEN 50121-3-2:2013] has been prepared by CLC/TC 9X " Electrical and electronic
41 applications for railways".
42 This document is currently submitted to the Enquiry.
43 This document will supersede EN 50121-3-2:2006.
44 prEN 50121-3-2:2013 includes the following significant technical changes with respect to EN 50121-3-2:2006:
45 clarification of scope (Clause 1);
46 set dated normative references (Clause 2);
47 new definition of ports and clarification in Tables 1 – 6;
48 emission requirement extended in the frequency range 1 GHz – 6 GHz following EN 61000-6-4;
49 immunity requirement extended in the frequency range 5,1 GHz – 6 GHz;
50 revision of Annex B.
51 EN 50121 "Railway applications – Electromagnetic compatibility" consists of the following parts:
52 • Part 1: General;
53 • Part 2: Emission of the whole railway system to the outside world;
54 • Part 3-1: Rolling stock – Train and complete vehicle;
55 • Part 3-2: Rolling stock – Apparatus;
56 • Part 4: Emission and immunity of the signalling and telecommunications apparatus;
57 • Part 5: Emission and immunity of fixed power supply installations and apparatus.
58 This European Standard is to be read in conjunction with EN 50121-1.
59 This document has been prepared under a mandate given to CENELEC by the European Commission and the
60 European Free Trade Association, and supports essential requirements of EU Directive(s).
61 For the relationship with EU Directive(s) see informative Annex ZZ, which is an integral part of this document.
4
---------------------- Page: 6 ----------------------
oSIST prEN 50121-3-2:2014
prEN 50121-3-2:2013 (E)
62 1 Scope
63 This European Standard applies to emission and immunity aspects of EMC for electrical and electronic
64 apparatus intended for use on railway rolling stock. EN 50121-3-2 applies for the integration of apparatus on
65 rolling stock.
66 The frequency range considered is from DC to 400 GHz. No measurements need to be performed at
67 frequencies where no requirement is specified.
68 The application of tests shall depend on the particular apparatus, its configuration, its ports, its technology and
69 its operating conditions.
70 This European Standard takes into account the internal environment of the railway rolling stock and the
71 external environment of the railway, and interference to the apparatus from equipment such as hand-held radio
72 transmitters.
73 If a port is intended to transmit or receive for the purpose of radio communication (intentional radiators, e.g.
74 transponder systems), then the radiated emission requirement in this European Standard are not intended to
75 be applicable to the intentional transmission from a radio transmitter as defined by the ITU.
76 Immunity limits do not apply in the exclusion bands as defined in the corresponding EMC related standard for
77 radio equipment.
78 This European Standard does not apply to transient emissions when starting or stopping the apparatus.
79 The objective of this European Standard is to define limits and test methods for electromagnetic emissions
80 and immunity test requirements in relation to conducted and radiated disturbances.
81 These limits and tests represent essential electromagnetic compatibility requirements.
82 Emission requirements have been selected so as to ensure that disturbances generated by the apparatus
83 operated normally on railway rolling stock do not exceed a level which could prevent other apparatus from
84 operating as intended. The emission limits given in this European Standard take precedence over emission
85 requirements for individual apparatus onboard the rolling stock given in other standards.
86 Likewise, the immunity requirements have been selected so as to ensure an adequate level of immunity for
87 rolling stock apparatus.
88 The levels do not however cover all cases which may occur with an extremely low probability of occurrence in
89 any location. Specific requirements which deviate from this European Standard shall be specified.
90 Test requirements are specified for each port considered.
91 These specific provisions are to be used in conjunction with the general provisions in EN 50121-1.
5
---------------------- Page: 7 ----------------------
oSIST prEN 50121-3-2:2014
prEN 50121-3-2:2013 (E)
92 2 Normative references
93 The following documents, in whole or in part, are normatively referenced in this document and are
94 indispensable for its application. For dated references, only the edition cited applies. For undated references,
95 the latest edition of the referenced document (including any amendments) applies.
EN 50121-1 date Railway applications – Electromagnetic compatibility
Part 1: General
EN 50121-3-1 Date Railway applications – Electromagnetic compatibility
Part 3-1: Rolling stock – Train and complete vehicle
EN 50155 07.2007 Railway applications – Electronic equipment used on rolling stock
EN 55016-1-4 2010 Specification for radio disturbance and immunity measuring apparatus and
methods - Part 1-4: Radio disturbance and immunity measuring apparatus –
Antennas and test sites for radiated disturbance Measurements (IEC/CISPR
16-1-4:2010 + Cor.:2010)
EN 55016-2-1 03.2009 Specification for radio disturbance and immunity measuring apparatus and
methods - Part 2-1: Methods of measurement of disturbances and immunity -
Conducted disturbance measurements (CISPR 16-2-1:2008)
EN 55016-2-3 06.2010 Specification for radio disturbance and immunity measuring apparatus and
+A1 10.2010 methods - Part 2-3: Methods of measurement of disturbances and immunity –
Radiated disturbance measurements
(IEC/CISPR 16-2-3:2010 + A1:2010)
EN 55022 12.2010 Information technology equipment – Radio disturbance characteristics – Limits
and methods of measurement (CISPR 22, mod.)
EN 61000-4-2 03.2009 Electromagnetic compatibility (EMC)
Part 4-2: Testing and measurement techniques – Electrostatic discharge
immunity test (IEC 61000-4-2)
EN 61000-4-3 05.2006 Electromagnetic compatibility (EMC)
Part 4-3: Testing and measurement techniques – Radiated, radio-frequency,
electromagnetic field immunity test (IEC 61000-4-3)
EN 61000-4-4 12.2004 Electromagnetic compatibility (EMC)
Part 4-4: Testing and measurement techniques – Electrical fast transient/burst
immunity test (IEC 61000-4-4)
EN 61000-4-5 11.2006 Electromagnetic compatibility (EMC)
Part 4-5: Testing and measurement techniques – Surge immunity test
(IEC 61000-4-5)
EN 61000-4-6 03.2009 Electromagnetic compatibility (EMC)
Part 4-6: Testing and measurement techniques – Immunity to conducted
disturbances, induced by radio-frequency fields (IEC 61000-4-6)
EN 61000-4-30 01.2009 Electromagnetic compatibility (EMC) - Part 4-30: Testing and measurement
techniques - Power quality measurement methods (IEC 61000-4-30:2008)
EN 61000-6-4 01.2007 Electromagnetic Compatibility (EMC) – Part 6-4 Generic standards – Emission
02.2011 standard for industrial environments (IEC 61000-6-4: 2006 + A1: 2010)
6
---------------------- Page: 8 ----------------------
oSIST prEN 50121-3-2:2014
prEN 50121-3-2:2013 (E)
96 3 Terms, definitions and abbreviations
97 3.1 Terms and definitions
98 For the purposes of this document, the following terms and definitions apply
99 3.1.1
100 rolling stock apparatus
101 finished product with an intrinsic function intended for implementation into the rolling stock installation
102 3.1.2
103 port
104 particular interface of the specified apparatus with the external environment e.g. auxiliary AC or DC power port,
105 I/O (input/output) port
106 3.1.3
107 enclosure port
108 physical boundary of the apparatus through which electromagnetic fields may radiate or impinge
109 The main categories of ports for rolling stock apparatus are presented in Figure 1.
Enclosure port
Signal &
Auxiliary AC or DC
ROLLING
communication port
power port
STOCK
APPARATUS Process measurement &
Battery power supply
control port
110
111 Figure 1 – Main categories of ports
112 Typical examples of rolling stock apparatus with their ports are listed in Annex A.
113 Traction power ports are not covered in EN 50121-3-2, see Annex B.
114 3.2 Abbreviations
115 For the purposes of this document, the following abbreviations apply.
116 AC Alternating current
117 AM Amplitude modulation
118 CISPR Comité international spécial des perturbations radioélectriques
119 DC Direct current
120 EMC Electromagnetic compatibility
121 EUT Equipment under test
122 I/O Input / Output
123 OATS Open area test site
7
---------------------- Page: 9 ----------------------
oSIST prEN 50121-3-2:2014
prEN 50121-3-2:2013 (E)
124 PC Personal computer
125 SAC Semi anechoic chamber
126 THD Total harmonic distortion
127 TV Television
128 4 Performance criteria
129 The variety and the diversity of the apparatus within the scope of this European Standard make it difficult to
130 define precise criteria for the evaluation of the immunity test results.
131 A functional description and a definition of performance criteria, during or as a consequence of the EMC
132 testing, shall be provided by the manufacturer and noted in the test report, based on the criteria A, B, C
133 defined in EN 50121-1.
134 5 Conditions during testing
135 It is not always possible to test every function of the apparatus. The tests shall be made at a typical operating
136 mode considered by the manufacturer to produce the largest emission or maximum susceptibility to noise as
137 appropriate in the frequency band being investigated consistent with normal applications. The conditions
138 during testing shall be defined in a test plan (see basic standard).
139 If the apparatus is part of a system, or can be connected to auxiliary apparatus, then the apparatus shall be
140 tested while connected to the minimum configuration of auxiliary apparatus necessary to exercise the ports in
141 accordance e.g. with EN 55022 (Clause 8).
142 The configuration and mode of operation shall be specified in the test plan and the actual conditions, during
143 the tests, shall be precisely noted in the test report.
144 If the apparatus has a large number of similar ports or ports with many similar connections, then a sufficient
145 number shall be selected to simulate actual operating conditions and to ensure that all the different types of
146 termination are covered (e.g. 20 % of the ports or at least four ports).
147 The tests shall be carried out within the specified operating range for the apparatus and at its nominal supply
148 voltage, unless otherwise indicated.
149 6 Applicability
150 The measurements in this European Standard shall be made on the relevant ports of the apparatus.
151 It may be determined from consideration of the electrical characteristics, the connection and the usage of a
152 particular apparatus that some of the tests are not applicable (e.g. radiated immunity of induction motors,
153 transformers). In such cases, the decision not to test has to be recorded in the test plan and test report.
154 If not otherwise specified, the EMC tests shall be type tests.
8
---------------------- Page: 10 ----------------------
oSIST prEN 50121-3-2:2014
prEN 50121-3-2:2013 (E)
155 7 Emission tests and limits
156 The emission tests and limits for apparatus covered by this European Standard are given on a port by port
157 basis.
158 Measurements shall be performed in well-defined and reproducible conditions for each type of disturbance.
159 The description of the test, the test methods and the test set-up are given in Basic Standard
...