Coating plants - Combined booths - Safety requirements

This document is applicable to combined booths for the application of organic liquid coating materials by an operator with maximum drying temperature of 100 °C and deals with all hazards significant for combined booths, when they are used as intended and under the conditions foreseen by the manufacturer (see clause 4).
To the extent of this document, a combined booth is considered an assembly of the following equipment:
-   forced ventilation by one or more fans,
-   ventilation air heating system (e. g. heat exchanger or burner),
-   power driven dampers, forced ventilation ducting,
-   dry air filtering and/or wet air washing systems,
-   automatic fire extinguishing equipment and additional specific electrical equipment,
-   control and power circuits joined together for the spraying and drying process of liquid coating material in a space totally enclosed provided with forced ventilation.
-   working pit, in special case.
This document does not cover:
a)   booths for automatic spraying, powder spray booths, open booths, and portable heaters.
b)   design of the building foundations upon which a booth is installed;
c)   the civil engineering and building design where a booth is constructed as, or to use part of, a new or existing building;
d)   spraying equipment (see EN 1953), automatic devices for spraying systems like robots (see EN 775) or reciprocators or similar systems, conveyors, lifts and continuous handling equipment and systems (see EN 619).
This document is not applicable to combined booths which are manufactured before the date of publication of this standard by CEN.

Beschichtungsanlagen - Kombinierte Spritz- und Trocknungskabinen - Sicherheitsanforderungen

Dieses Dokument gilt für kombinierte Kabinen zum Auftragen von organischen flüssigen Beschichtungsstoffen
durch Bedienungspersonen bei einer höchsten Trocknungstemperatur von 100 °C und behandelt alle signifikanten
Gefährdungen, die auf kombinierte Kabinen zutreffen, wenn sie bestimmungsgemäß und entsprechend
den vorhersehbaren Bedingungen des Herstellers verwendet werden (siehe Abschnitt 4).
Im Sinne dieses Dokuments ist eine kombinierte Kabine eine Gesamtheit der folgenden Ausrüstung:
⎯ technische Lüftung durch einen oder mehrere Ventilator(en),
⎯ Heizsystem für die technische Lüftung (z. B. Wärmetauscher oder Brenner),
⎯ kraftbetriebene Drossel- und Umschaltklappen,
⎯ Trockenluftfilter- und/oder Luft-Nassreinigungssysteme,
⎯ automatische Brandlöscheinrichtung/elektrische Ausrüstung,
⎯ Steuer- und Energiekreise, die zum Auftragen und Trocknen der flüssigen Beschichtungsstoffe in einem
mit einer technischen Lüftung ausgestatteten geschlossenen Raum zusammengefügt sind,
⎯ in besonderen Fällen: Arbeitsgrube.
Dieses Dokument gilt nicht für:
a) Spritzkabinen mit automatischen Spritzsystemen, Spritzkabinen für organische Pulverlacke (Pulverbeschichtungskabinen),
offene Spritzkabinen (Spritzstände und -wände) und ortsbewegliche Heizeinrichtungen,
b) Gestaltung und Konstruktion von Fundament und Gebäude, wo die kombinierte Kabine aufgestellt ist;
c) Bauwesen und Architektur, wenn die Kabine als Teil eines neuen oder bereits vorhandenen Gebäudes
gestaltet und konstruiert ist;
d) Spritzeinrichtungen (siehe EN 1953), automatische Einrichtungen für Spritzsysteme, z. B. Roboter (siehe
EN 775) oder Bewegungseinrichtungen oder ähnliche Systeme, Förderer, Hubeinrichtungen und Stetigförderer
(siehe EN 619).
Dieses Dokument gilt nicht für kombinierte Kabinen, die hergestellt wurden, bevor CEN dieses Dokument
veröffentlichte.

Installations d'application - Cabines mixtes d'application et de séchage - Prescriptions de sécurité

Le présent document est applicable aux cabines mixtes utilisées pour l’application de produits de revêtement
organiques liquides par un opérateur, avec séchage à une température maximum de 100 °C ; elle traite de tous les
phénomènes dangereux significatifs spécifiques des cabines mixtes lorsqu’elles sont utilisées normalement et dans
les conditions prévues par le !fabricant" (voir Article 4).
Dans le cadre du présent document, une cabine mixte est considérée comme un assemblage des équipements
suivants :
— ventilation forcée via un ou plusieurs ventilateurs ;
— système de chauffage de l’air de ventilation (par exemple, échangeur de chaleur, brûleur) ;
— registres motorisés, système de gaines pour la ventilation forcée ;
— système de filtration d’air sec et/ou d’assainissement d’air humide ;
— équipement automatique d’extinction d’incendie et équipement électrique spécifique supplémentaire ;
— circuits de commande et de puissance combinés pour les processus de pulvérisation et de séchage des produits
de revêtement liquide dans un espace totalement clos doté d’une ventilation forcée ;
— fosse de travail, dans des cas spéciaux.
Le présent document n’est pas applicable :
a) aux cabines de pulvérisation automatique, aux cabines de poudrage, aux cabines ouvertes et aux appareils
de chauffage mobiles ;
b) à la conception des fondations sur lesquelles est installée la cabine ;
c) à la conception architecturale des bâtiments neufs ou anciens utilisés partiellement comme cabines ;
d) aux équipements de pulvérisation (voir EN 1953), aux dispositifs automatiques pour les systèmes de pulvérisation
comme les robots industriels (voir EN 775) ou les appareils à mouvements de va-et-vient ou systèmes similaires,
les convoyeurs, les appareils de levage et les systèmes et équipements de manutention continue (voir EN 619).
La présent document ne s’applique pas aux cabines mixtes fabriquées avant la date de publication de cette norme
par le CEN.

Premazne naprave - Kombinirane kabine za brizganje in sušenje - Varnostne zahteve

General Information

Status
Withdrawn
Publication Date
06-Apr-2009
Withdrawal Date
07-Mar-2019
Technical Committee
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
14-Dec-2018
Due Date
06-Jan-2019
Completion Date
08-Mar-2019

Relations

Buy Standard

Standard
EN 13355:2005+A1:2009
English language
47 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Premazne naprave - Kombinirane kabine za brizganje in sušenje - Varnostne zahteveBeschichtungsanlagen - Kombinierte Spritz- und Trocknungskabinen - SicherheitsanforderungenInstallations d'application - Cabines mixtes d'application et de séchage - Prescriptions de sécuritéCoating plants - Combined booths - Safety requirements87.100Oprema za nanašanje premazovPaint coating equipmentICS:Ta slovenski standard je istoveten z:EN 13355:2004+A1:2009SIST EN 13355:2005+A1:2009en,fr01-maj-2009SIST EN 13355:2005+A1:2009SLOVENSKI
STANDARDSIST EN 13355:20051DGRPHãþD



SIST EN 13355:2005+A1:2009



EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 13355:2004+A1
April 2009 ICS 87.100 Supersedes EN 13355:2004English Version
Coating plants - Combined booths - Safety requirements
Installations d'application - Cabines mixtes d'application et de séchage - Prescriptions de sécurité
Beschichtungsanlagen - Kombinierte Spritz- und Trocknungskabinen - Sicherheitsanforderungen This European Standard was approved by CEN on 22 November 2004 and includes Amendment 1 approved by CEN on 22 February 2009. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2009 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 13355:2004+A1:2009: ESIST EN 13355:2005+A1:2009



EN 13355:2004+A1:2009 (E) 2 Contents Page Foreword . 4Introduction . 51Scope . 62Normative references . 73Terms and definitions . 94List of significant hazards . 114.1General . 114.2Mechanical hazards . 114.3Electrical hazards . 124.4Thermal hazards . 124.5Hazards generated by noise . 124.6Hazards generated by radiation . 134.7Hazards resulting from dangerous substances . 134.8Fire and explosion hazards . 134.9Hazards caused by failure of the energy supply and malfunction of the control system . 144.10Hazards caused by emergency stop devices . 145Safety requirements and/or measures . 145.1General . 145.2Mechanical . 155.3Electrical . 165.4Thermal . 165.5Noise . 165.6Radiation . 175.7Safety requirements against dangerous substances . 175.8Fire and explosion prevention and protection . 195.9Failure of energy supply and malfunction of the control system . 235.10Emergency stop devices . 246Verification of the safety measure and/or measures . 246.1General . 246.2Mechanical . 246.3Electrical . 246.4Thermal . 246.5Noise . 246.6Radiation . 246.7Dangerous substances . 246.8Fire and explosion . 256.9Failure of energy supply . 266.10Emergency stop devices . 267Information for use . 267.1General . 267.2Instruction handbook . 277.3Marking . 29Annex A (normative)
Determination of concentration of flammable solvents in terms of LEL (spraying mode) . 31A.1Equations . 31A.2Examples of calculation . 32Annex B (normative)
Measurement of air velocities . 34SIST EN 13355:2005+A1:2009



EN 13355:2004+A1:2009 (E) 3 B.1Instrumentation . 34B.2Measurement conditions . 34Annex C (informative)
Classification of material’s reaction to the fire – National standards . 41Annex D (informative)
References to national exposure limit values . 42Annex E (informative)
Equivalence between zone description and categories of ignition protection . 43Annex ZA (informative)
Relationship between this European Standard and the Essential Requirements of EU Directive 98/37/EC !, amended by 98/79/EC" . 44Annex ZB (informative)
!Relationship between this European Standard and the Essential Requirements of EU Directive 2006/42/EC" . 45Bibliography . 46 SIST EN 13355:2005+A1:2009



EN 13355:2004+A1:2009 (E) 4 Foreword This document (EN 13355:2004+A1:2009) has been prepared by Technical Committee CEN/TC 271 “Surface treatment equipment — Safety”, the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by October 2009, and conflicting national standards shall be withdrawn at the latest by December 2009. This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirements of EU Directive(s) 98/37/EC and 94/9/EC. !For relationship with EU Directive(s), see informative Annexes ZA and ZB, which are integral parts of this document." This document includes Amendment 1, approved by CEN on 2009-02-22. This document supersedes EN 13355:2004. The start and finish of text introduced or altered by amendment is indicated in the text by tags ! ". This document is part of a series of standards in the area of safety for development and construction of machines and plants for the coating of surfaces with organic substances (paints, varnishes and similar products). This document is mainly based on EN 12215 and EN 1539. NOTE Although a spray booth, as an integral whole, formally does not fall under the scope of the ATEX Directive 94/9/EC, the document is based upon a fundamental risk analysis according to this directive. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
SIST EN 13355:2005+A1:2009



EN 13355:2004+A1:2009 (E) 5 Introduction This document is a C-type standard as stated in EN ISO 12100. The machinery concerned and the extent to which hazards, hazardous situations and events are covered are indicated in the scope of this document. When provisions of this type C standard are different from those which are stated in type A or B standards, the provisions of this type C standard take precedence over the provisions of the other standards, for machines that have been designed and built according to the provisions of this type C standard. SIST EN 13355:2005+A1:2009



EN 13355:2004+A1:2009 (E) 6 1 Scope This document is applicable to combined booths for the application of organic liquid coating materials by an operator with maximum drying temperature of 100 °C and deals with all hazards significant for combined booths, when they are used as intended and under the conditions foreseen by the manufacturer (see clause 4). To the extent of this document, a combined booth is considered an assembly of the following equipment:  forced ventilation by one or more fans,
 ventilation air heating system (e. g. heat exchanger or burner),
 power driven dampers, forced ventilation ducting,
 dry air filtering and/or wet air washing systems,
 automatic fire extinguishing equipment and additional specific electrical equipment,
 control and power circuits joined together for the spraying and drying process of liquid coating material in a space totally enclosed provided with forced ventilation.  working pit, in special case. This document does not cover: a) booths for automatic spraying, powder spray booths, open booths, and portable heaters. b) design of the building foundations upon which a booth is installed; c) the civil engineering and building design where a booth is constructed as, or to use part of, a new or existing building; d) spraying equipment (see EN 1953), automatic devices for spraying systems like robots (see EN 775) or reciprocators or similar systems, conveyors, lifts and continuous handling equipment and systems (see EN 619). This document is not applicable to combined booths which are manufactured before the date of publication of this standard by CEN. SIST EN 13355:2005+A1:2009



EN 13355:2004+A1:2009 (E) 7 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 418, Safety of machinery — Emergency stop equipment, functional aspects — Principles for design EN 525, Non-domestic direct gas-fired forced convection air heaters for space heating not exceeding a net heat input of 300 kW EN 563, Safety of machinery — Temperatures of touchable surfaces — Ergonomics data to establish temperature limit values for hot surfaces EN 746-1, Industrial thermoprocessing equipment — Part 1: Common safety requirements for industrial thermoprocessing equipment EN 746-2, Industrial thermoprocessing equipment — Part 2: Safety requirements for combustion and fuel handling systems EN 954-1, Safety of machinery — Safety related parts of control systems — Part 1: General principles for design EN 971-1:1996, Paints and varnishes — Terms and definitions for coating materials — Part 1: General terms EN 981, Safety of machinery — System of auditory and visual danger and information signals EN 982, Safety of machinery — Safety requirements for fluid power systems and their components — Hydraulics EN 983, Safety of machinery — Safety requirements for fluid power systems and their components — Pneumatics EN 1037, Safety of machinery — Prevention of unexpected start-up EN 1088, Safety of machinery — Interlocking devices associated with guards — Principles for design and selection EN 1127-1:1997, Explosive atmospheres — Explosion prevention and protection — Part 1: Basic concepts and methodology EN 1539:2000; Dryers and ovens, in which flammable substances are released — Safety requirements EN 1953, Atomising and spraying equipment for coating materials — Safety requirements !EN 12753", Thermal cleaning systems for exhaust gas from surface treatment equipment — Safety requirements EN 12433-1, Industrial, commercial and garage doors and gates — Terminology — Part 1: Types of doors EN 12433-2, Industrial, commercial and garage doors and gates — Terminology — Part 2: Parts of doors EN 12445, Industrial, commercial and garage doors and gates — Safety in use of power operated doors — Test methods EN 12453, Industrial, commercial and garage doors and gates — Safety in use of power operated doors — Requirements EN 12635, Industrial, commercial and garage doors and gates — Installation and use EN 12978, Industrial, commercial and garage doors and gates — Safety devices for power operated doors and gates
— Requirements and test methods SIST EN 13355:2005+A1:2009



EN 13355:2004+A1:2009 (E) 8 EN 13463-1:2001, Non-electrical equipment for potentially explosive atmospheres — Part 1: Basic method and requirements EN 13463-5, Non-electrical equipment intended for use in potentially explosive atmospheres — Part 5: Protection by constructional safety "c" EN 13478, Safety of machinery — Fire prevention and protection !EN 14462:2005, Surface treatment equipment — Noise test code for surface treatment equipment including its ancillary handling equipment — Accuracy grades 2 and 3" !EN 14986", Design of fans working in potentially explosive atmospheres EN 60079-0, Electrical apparatus for explosive gas atmospheres — Part 0: General requirements (IEC 60079-0:2004) EN 60079-15, Electrical apparatus for explosive gas atmospheres — Part 15: Type of protection “n”
(IEC 60079-15:2001, modified) EN 60204-1:1997, Safety of machinery — Electrical equipment of machines — Part 1: General requirements
(IEC 60204-1:1997) EN 60529, Degrees of protection provided by enclosures (IP code) EN 61000-6-1, Electromagnetic compatibility (EMC) — Part 6-1: Generic standards; Immunity for residential, commercial and light-industrial environments (IEC 61000-6-1:1997, modified) EN 61000-6-3, Electromagnetic compatibility (EMC) — Part 6-3: Generic standards; Emission standard for residential, commercial and light-industrial environments (IEC 61000-6-3:1996, modified) EN 61000-6-4, Electromagnetic compatibility (EMC) — Part 6-4: Generic standards; Emission standard for industrial environments (IEC 61000-6-4:1997, modified) EN ISO 3746, Acoustics — Determination of sound power levels of noise sources using sound pressure — Survey method using an enveloping measurement surface over a reflecting plane (ISO 3746:1995) EN ISO 4871, Acoustics — Declaration and verification of noise emission values of machinery and equipment
(ISO 4871:1996) EN ISO 11202, Acoustics — Noise emitted by machinery and equipment — Measurement of emission sound pressure levels at a work station and at other specified positions — Survey method in situ (ISO 11202:1995) EN ISO 12100-1, Safety of machinery — Basic concepts, general principles for design — Part 1: Basic terminology, methodology (ISO 12100-1:2003) EN ISO 12100-2:2003, Safety of machinery — Basic concepts, general principles for design — Part 2: Technical principles (ISO 12100-2:2003) EN ISO 14122-2, Safety of machinery — Permanent means of access to machinery — Part 2: Working platforms and walkways (ISO 14122-2:2001) EN ISO 14122-3, Safety of machinery — Permanent means of access to machinery — Part 3: Stairs, stepladders and guard-rails (ISO 14122-3:2001) EN ISO 14122-4, Safety of machinery — Permanent means of access to machinery — Part 4: Fixed ladders
(ISO 14122-4:2004) SIST EN 13355:2005+A1:2009



EN 13355:2004+A1:2009 (E) 9 3 Terms and definitions For the purpose of this document, the terms and definitions given in EN 12100-1:2003 and the following apply. 3.1 combined booth assembly of linked components such as fan(s), ventilation air heating system (e. g. heat exchanger or burner), power driven dampers, forced ventilation ducting, dry air filtering and/or wet air washing systems, automatic fire extinguishing equipment and additional specific electrical equipment, control and power circuits joined together for the spraying and drying process of liquid coating material in a space totally enclosed provided with a forced ventilation 3.2 working pit ground excavation, illuminated and ventilated in which the operator works while painting the underside of an item 3.3 organic liquid coating material organic product, in liquid form, that when applied to a
substrate forms a film possessing protective, decorative and/or specific technical properties, e.g.: paints, varnishes, including their solvents and thinners (see EN 971-1) 3.4 solvent single liquid, or blends of liquid, volatile under specified drying conditions, and in which the binder is completely soluble (see 1.4.5 of EN 971-1:1996) NOTE Solvents are also contained in liquids used as cleaning or washing agents. 3.5 spraying application of coating material on an item within the combined booth by pneumatic, airless, electrostatic or combination of these spraying systems 3.6 drying evaporation of liquids from the materials being processed (see 3.5 of EN 1539:2000). 3.7 curing Transformation of a liquid, paste or powder coating material into a finished solid material (see 3.8 of EN 1539:2000) NOTE Also known as gelling, through curing or through drying. 3.8 forced ventilation air circulation achieved by one or several fans 3.9 recirculated air air extracted from the volume and reintroduced into it 3.10 air cleaning (filtering system) Filtering system used for introducing clean air into the booth and cleaning contaminated air extracted from the combined booth SIST EN 13355:2005+A1:2009



EN 13355:2004+A1:2009 (E) 10 3.11 flammable (combustible) substances substance in the form of gas, vapour, liquid, solid or mixtures of these, able to undergo an exothermic reaction with air when ignited (see 3.1 of EN 1127-1:1997) NOTE "Combustible materials" and "flammable substances" are equivalently used terms in this standard. Examples are paint aerosols and solvents. 3.12 explosive atmosphere mixture with air, under atmospheric conditions, of flammable substance(s) in the form of gas, vapour, mist or dust, in which after ignition has occurred, combustion spreads
to the entire unburned mixture (see EN 1127-1) 3.13 lower explosion limit (LEL) lower limit of the range of concentration of a combustible in air over which an explosion can occur (3.8 and 3.13 of EN 1127-1:1997) NOTE ”Explosion limit” and ”Ignition limit” are equivalent. In accordance with international usage, only the term ”explosion limit" is used in this standard. 3.14 total space net volume within the booth during spraying and drying processes which may contain released substances. It includes all sections of the combined booth recirculation system(s) and ends at the outlet connection to the external exhaust NOTE It does not include any items loaded into the combined booth, supports, transport systems or thermal cleaning systems (see !EN 12753"). 3.15 hazardous areas areas where hazards due to explosive atmosphere may exist. The probability of occurrence of explosive atmosphere is classified in zones 3.15.1 zone 0 place in which an explosive atmosphere consisting of a mixture with air of flammable substances in the form of gas, vapour or mist is present continuously or for long periods or frequently (see 6.3.2 of EN 1127-1:1997) 3.15.2 zone 1 place in which an explosive atmosphere consisting of a mixture with air of flammable substances in the form of gas, vapour or mist is likely to occur in normal operation occasionally (see 6.3.2 of EN 1127-1:1997) 3.15.3 zone 2 place in which an explosive atmosphere consisting of a mixture with air of flammable substances in the form of gas, vapour or mist is not likely to occur in normal operation but, if it does occur, will persist for a short period only (see 6.3.2 of EN 1127-1:1997) 3.16 Equipment category
3.16.1 Equipment Group II Category 1 equipment in this category is intended for use in areas in which explosive atmospheres caused by mixtures of air and gases, vapours or mists are present continuously for long periods or frequently (see 3.2.3 of EN 13463-1:2001) NOTE Equipment of category 1 is suitable for use in zone 0. SIST EN 13355:2005+A1:2009



EN 13355:2004+A1:2009 (E) 11 3.16.2 Equipment Group II Category 2 equipment in this category is intended for use in areas in which explosive atmospheres caused by mixtures of air and gases, vapours or mists are likely to occur (see 3.2.4 of EN 13463-1:2001) NOTE Equipment of category 2 is suitable for use in zone 1. 3.16.3 Equipment Group II Category 3 equipment in this category is intended for use in areas in which explosive atmospheres caused by mixtures of air and gases, vapours or mists are unlikely to occur, or, if they do occur, are likely to do so only in frequently and for a short period only (see 3.2.5 of EN 13463-1:2001) NOTE Equipment of category 3 is suitable for use in zone 2. 3.17 exposure limits concentration limits of hazardous substances in air required by worker health legislation NOTE Limits are different according to the countries (see Annex !D"). 3.18 maximum drying temperature upper limit of circulated air temperature within the working area for which the combined booth is designed 3.19 ventilation air heating system heat generating and air heat exchanger system direct or indirect, which may include burner, combustion chamber, heat exchanger, fan(s), inlet, exhaust and recirculation ducts, enclosures and ancillaries, measuring and control devices 4 List of significant hazards 4.1 General This clause contains all the significant hazards, hazardous situations and events as far as they are dealt with in this standard, identified by risk assessment as significant for this type of machinery and which require action to eliminate or reduce the risk. All hazards generated by spraying equipment for liquid paint and varnish and their ancillary devices are covered by EN 1953. NOTE Information on the method of risk analysis is given in EN 1050. 4.2 Mechanical hazards 4.2.1 Shearing, crushing and drawing in These hazards are related to:  unexpected actuation of conveyor (whilst loading the combined booth)  fans (e.g. injuries caused by after-running of fan blades) and air change valves for the combined booth  damper adjusters (power driven dampers),
 moving parts of combined booth (e.g. doors, gates and hoods). SIST EN 13355:2005+A1:2009



EN 13355:2004+A1:2009 (E) 12 4.2.2 Entrapment of operators These hazards are related to:  obstacles or obstructions which can impede evacuation from the combined booth including any working pit in case of mechanical accident or
the occurrence of fire;  accidental significant lowering of pressure inside the combined booth (i.e.: obstruction of air inlet) capable of  clamping the doors by mechanical deformation of the structure of the combined booth;  increasing the door opening effort beyond human capability. 4.2.3 Hazards resulting from the operator slipping or falling: These hazards are related to:  ladders, gangways, platform or stairs;  floor gratings;  slippery floors; These hazards may be increased as a result of poor lighting. 4.3 Electrical hazards 4.3.1 Electrical shock (by direct or indirect contact) These hazards are related to:  electrically live parts that are non insulated for operational reasons (for instance in electrostatic devices);  live parts when insulation is damaged by contact with solvents or by mechanical means. 4.3.2 External influence on electrical equipment These hazards are related to:  interaction of the electrostatic high voltage equipment elements of the control and safety systems which can cause dangerous malfunctions, e. g. short circuits on electronic safety circuits, entrance guards, alarm units. 4.4 Thermal hazards These hazards are related to:  contact with hot surfaces within easy reach. 4.5 Hazards generated by noise These hazards are related to combined booths and can be present inside as well as outside the booth. They can be generated by noises emitted for instance by:  fans;  excessive air velocity in ducts and accessories; SIST EN 13355:2005+A1:2009



EN 13355:2004+A1:2009 (E) 13  wet air washing systems;  air operated equipment ( nozzles of atomising and spraying equipment, pumps, valves.). 4.6 Hazards generated by radiation These hazards are related to the use of infra-red radiation (IR) causing  damage to the eyes,  burning. 4.7 Hazards resulting from dangerous substances 4.7.1 Contact with/or absorption of, fluids (paints, solvents, hydraulic a
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.