SIST EN ISO 11201:2010
(Main)Acoustics - Noise emitted by machinery and equipment - Determination of emission sound pressure levels at a work station and at other specified positions in an essentially free field over a reflecting plane with negligible environmental corrections (ISO 11201:2010)
Acoustics - Noise emitted by machinery and equipment - Determination of emission sound pressure levels at a work station and at other specified positions in an essentially free field over a reflecting plane with negligible environmental corrections (ISO 11201:2010)
This International Standard specifies a method for determining the emission sound pressure levels of machinery or equipment, at a work station and at other specified positions nearby, in an essentially free field over a reflecting plane. A work station is occupied by an operator and may be located in open space, in the room where the source under test operates, in a cab fixed to the source under test, or in an enclosure remote from the source under test. One or more specified positions may be located in the vicinity of a work station, or in the vicinity of an attended or unattended machine. Such positions are sometimes referred to as bystander positions. Emission sound pressure levels are determined as A-weighted levels. Additionally, levels in frequency bands and C-weighted peak emission sound pressure levels can be determined in accordance with this International Standard, if required.
Akustik - Geräuschabstrahlung von Maschinen und Geräten - Messung von Emissions-Schalldruckpegeln am Arbeitsplatz und an anderen festgelegten Orten in einem im Wesentlichen freien Schallfeld über einer reflektierenden Ebene mit vernachlässigbaren Umgebungskorrekturen (ISO 11201:2010)
Diese Internationale Norm legt ein Verfahren zur Bestimmung der Emissions-Schalldruckpegel von
Maschinen oder Geräten am Arbeitsplatz und an anderen, sich in der Nähe befindenden, festgelegten Orten
in einem im Wesentlichen freien Schallfeld über einer reflektierenden Ebene fest. Ein Arbeitsplatz wird von
einer Bedienungsperson eingenommen; er kann sich im Freien, in einem Raum, in dem die untersuchte
Quelle betrieben wird, in einer Kabine, die fest mit der untersuchten Quelle verbunden ist, oder in einem von
der untersuchten Quelle entfernt liegenden Bedienerstand befinden. Einer oder mehrere der festgelegten Orte
können in der Umgebung eines Arbeitsplatzes oder im Umfeld einer bedienten oder unbeaufsichtigt
betriebenen Maschine liegen. Derartige Orte werden gelegentlich als „Nachbararbeitsplätze“ bezeichnet.
Emissions-Schalldruckpegel werden als A-bewertete Pegel bestimmt. Falls erforderlich, können zusätzlich
Pegel in Frequenzbändern und C-bewertete Emissions-Spitzenschalldruckpegel nach dieser Internationalen
Norm ermittelt werden.
ANMERKUNG 1 Der Inhalt der Normreihe ISO 11200 [15] bis ISO 11205 [19] ist in ISO 11200 [15] zusammengefasst.
Mit dem in dieser Internationalen Norm festgelegten Verfahren werden Ergebnisse der Genauigkeitsklasse 1
oder der Genauigkeitsklasse 2 erzielt. Korrekturen werden bezüglich des Fremdgeräuschs vorgenommen,
nicht aber bezüglich der akustischen Umgebung. Es werden Anweisungen für die Aufstellung und den Betrieb
der untersuchten Quelle und für die Wahl der Mikrofonpositionen am Arbeitsplatz und den anderen festgelegten
Orten gegeben. Ein Zweck der Messungen besteht darin, einen Vergleich der Daten unterschiedlicher
Exemplare aus einer bestimmten Maschinengruppe unter festgelegten Umgebungsbedingungen und
genormten Aufstellungs- und Betriebsbedingungen zu ermöglichen.
ANMERKUNG 2 Die erhaltenen Daten können auch für die Angabe und Nachprüfung von Emissions-Schalldruckpegeln
nach ISO 4871 [8] verwendet werden.
Acoustique - Bruit émis par les machines et équipements - Mesurage des niveaux de pression acoustique d'émission au poste de travail et en d'autres positions spécifiées dans des conditions approchant celles du champ libre sur plan réfléchissant avec des corrections d'environnement négligeables (ISO 11201:2010)
L'ISO 11201:2010 spécifie une méthode de détermination des niveaux de pression acoustique d'émission des machines ou de l'équipement au poste de travail et en d'autres positions spécifiées proches, dans des conditions approchant celles du champ libre sur plan réfléchissant. Le poste de travail occupé par un opérateur peut être situé dans un espace ouvert, dans la salle où la source soumise à essai fonctionne, dans une cabine fixée à la source soumise à essai ou dans une enceinte située à distance de la source soumise à essai. Une ou plusieurs positions spécifiées peuvent se situer au voisinage du poste de travail ou d'une machine avec ou sans opérateur. Ces positions sont parfois appelées «positions d'assistant».
Les niveaux de pression acoustique d'émission sont déterminés en tant que niveaux pondérés A. En outre, les niveaux par bandes de fréquences et les niveaux de pression acoustique d'émission de crête pondérés C peuvent être déterminés selon l'ISO 11201:2010, si nécessaire.
La méthode spécifiée dans l'ISO 11201:2010 permet d'obtenir des résultats de classe de précision 1 (laboratoire) ou de classe de précision 2 (expertise). Des corrections sont appliquées pour le bruit de fond mais pas pour l'environnement acoustique. Des instructions sont fournies pour le montage et le fonctionnement de la source soumise à essai ainsi que pour le choix des positions du microphone pour le poste de travail et pour d'autres positions spécifiées. Un des objets des mesurages est de permettre la comparaison des performances de différentes unités d'une famille donnée de machines, dans des conditions d'environnement définies et dans des conditions de montage et de fonctionnement normalisées.
La méthode spécifiée dans l'ISO 11201:2010 convient à tous les types de bruits (continus, discontinus, fluctuants, pics d'énergie acoustique isolés, etc.) définis dans l'ISO 12001.
La méthode spécifiée dans l'ISO 11201:2010 s'applique à tous les types et toutes les tailles de sources de bruit.
Le type d'environnement d'essai affecte la précision de la détermination des niveaux de pression acoustique d'émission. Pour l'application de l'ISO 11201:2010, les conditions approchant celles du champ libre sur plan réfléchissant (en salle ou en plein air) sont nécessaires.
L'ISO 11201:2010 s'applique aux postes de travail et aux autres positions spécifiées auxquels les niveaux de pression acoustique d'émission doivent être mesurés.
Les positions appropriées où les mesurages peuvent être effectués incluent les positions suivantes: a) poste de travail situé au voisinage de la source soumise à essai, ce qui est le cas de nombreuses machines industrielles et de nombreux appareils domestiques; b) poste de travail à l'intérieur d'une cabine faisant partie intégrante de la machine soumise à essai; ce qui est le cas de nombreux véhicules industriels et engins de terrassement; c) poste de travail à l'intérieur d'une enceinte partielle ou totale (ou derrière un écran), fournie par le fabricant en tant que partie intégrante de la machine ou de l'équipement; d) poste de travail partiellement ou complètement entouré par la source soumise à essai, comme c'est parfois le cas avec certaines machines industrielles de grandes dimensions; e) postes d'assistant occupés par des personnes non responsables du fonctionnement de la source soumise à essai, mais qui peuvent se trouver, occasionnellement ou en continu, à proximité immédiate de la machine; f) d'autres positions spécifiées, qui ne sont
Akustika - Emisija hrupa naprav in opreme - Merjenje emisijske ravni zvočnega tlaka na delovnem mestu in na drugih opredeljenih mestih v pretežno prostem zvočnem polju nad odbojno ravnino z zanemarljivimi popravki zaradi okolja (ISO 11201:2010)
Ta mednarodni standard določa metodo merjenja emisijske ravni zvočnega tlaka strojev ali opreme na delovnem mestu in na drugih bližnjih opredeljenih mestih v pretežno prostem zvočnem polju nad odbojno ravnino. Delovno mesto zaseda operater in je lahko locirano na prostem, v sobi, kjer vir, ki je preskušan, deluje, v kabini, pritrjeni na vir, ki je preskušan, ali ograjenem prostoru, ki je oddaljen od vira, ki je preskušan. Ena ali več določeni pozicij je lahko lociranih v bližini delovnega mesta, ali v bližini nadzorovanega ali nenadzorovanega stroja. Takšne pozicije se včasih omenja kot gledalske pozicije. Stopnje emisij zvočnega tlaka so določene kot A-ovrednotene stopnje. Poleg tega, če je potrebno, se stopnje v frekvenčnih pasovih in stopenj C-ovrednotenih vrhov zvočnega tlaka lahko določijo v skladu s tem mednarodnim standardom.
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
SIST EN ISO 11201:2010
01-september-2010
1DGRPHãþD
SIST EN ISO 11201:2009
$NXVWLND(PLVLMDKUXSDQDSUDYLQRSUHPH0HUMHQMHHPLVLMVNHUDYQL]YRþQHJD
WODNDQDGHORYQHPPHVWXLQQDGUXJLKRSUHGHOMHQLKPHVWLKYSUHWHåQRSURVWHP
]YRþQHPSROMXQDGRGERMQRUDYQLQR]]DQHPDUOMLYLPLSRSUDYNL]DUDGLRNROMD,62
Acoustics - Noise emitted by machinery and equipment - Determination of emission
sound pressure levels at a work station and at other specified positions in an essentially
free field over a reflecting plane with negligible environmental corrections (ISO
11201:2010)
Akustik - Geräuschabstrahlung von Maschinen und Geräten - Messung von Emissions-
Schalldruckpegeln am Arbeitsplatz und an anderen festgelegten Orten in einem im
Wesentlichen freien Schallfeld über einer reflektierenden Ebene mit vernachlässigbaren
Umgebungskorrekturen (ISO 11201:2010)
Acoustique - Bruit émis par les machines et équipements - Mesurage des niveaux de
pression acoustique d'émission au poste de travail et en d'autres positions spécifiées
dans des conditions approchant celles du champ libre sur plan réfléchissant avec des
corrections d'environnement négligeables (ISO 11201:2010)
Ta slovenski standard je istoveten z: EN ISO 11201:2010
ICS:
17.140.20 Emisija hrupa naprav in Noise emitted by machines
opreme and equipment
SIST EN ISO 11201:2010 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
SIST EN ISO 11201:2010
---------------------- Page: 2 ----------------------
SIST EN ISO 11201:2010
EUROPEAN STANDARD
EN ISO 11201
NORME EUROPÉENNE
EUROPÄISCHE NORM
May 2010
ICS 17.140.20 Supersedes EN ISO 11201:2009
English Version
Acoustics - Noise emitted by machinery and equipment -
Determination of emission sound pressure levels at a work
station and at other specified positions in an essentially free field
over a reflecting plane with negligible environmental corrections
(ISO 11201:2010)
Acoustique - Bruit émis par les machines et équipements - Akustik - Geräuschabstrahlung von Maschinen und
Détermination des niveaux de pression acoustique
Geräten - Bestimmung von Emissions-Schalldruckpegeln
d'émission au poste de travail et en d'autres positions am Arbeitsplatz und an anderen festgelegten Orten in
spécifiées dans des conditions approchant celles du champ einem im Wesentlichen freien Schallfeld über einer
libre sur plan réfléchissant avec des corrections reflektierenden Ebene mit vernachlässigbaren
d'environnement négligeables (ISO 11201:2010) Umgebungskorrekturen (ISO 11201:2010)
This European Standard was approved by CEN on 22 April 2010.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national
standards may be obtained on application to the CEN Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as the
official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland,
Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2010 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN ISO 11201:2010: E
worldwide for CEN national Members.
---------------------- Page: 3 ----------------------
SIST EN ISO 11201:2010
EN ISO 11201:2010 (E)
Contents Page
Foreword .3
Annex ZA (informative) Relationship between this European Standard and the Essential
Requirements of EU Directive 2006/42/EC .4
2
---------------------- Page: 4 ----------------------
SIST EN ISO 11201:2010
EN ISO 11201:2010 (E)
Foreword
This document (EN ISO 11201:2010) has been prepared by Technical Committee ISO/TC 43 “Acoustics” in
collaboration with Technical Committee CEN/TC 211 “Acoustics” the secretariat of which is held by DS.
This European Standard shall be given the status of a national standard, either by publication of an identical
text or by endorsement, at the latest by November 2010, and conflicting national standards shall be withdrawn
at the latest by November 2010.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights.
This document supersedes EN ISO 11201:2009.
This document has been prepared under a mandate given to CEN by the European Commission and the
European Free Trade Association, and supports essential requirements of EU Directive.
For relationship with EU Directive, see informative Annex ZA, which is an integral part of this document.
According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following
countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech
Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
Sweden, Switzerland and the United Kingdom.
Endorsement notice
The text of ISO 11201:2010 has been approved by CEN as a EN ISO 11201:2010 without any modification.
3
---------------------- Page: 5 ----------------------
SIST EN ISO 11201:2010
EN ISO 11201:2010 (E)
Annex ZA
(informative)
Relationship between this European Standard and the Essential
Requirements of EU Directive 2006/42/EC
This European Standard has been prepared under a mandate given to CEN by the European Commission
and the European Free Trade Association to provide a means of conforming to Essential Requirements of the
New Approach Directive 2006/42/EC on machinery.
Once this standard is cited in the Official Journal of the European Union under that Directive and has been
implemented as a national standard in at least one Member State, compliance with the normative clauses of
this standard confers, within the limits of the scope of this standard, a presumption of conformity with the
corresponding Essential Requirements of that Directive and associated EFTA regulations.
WARNING — Other requirements and other EU Directives may be applicable to the product(s) falling within
the scope of this standard.
4
---------------------- Page: 6 ----------------------
SIST EN ISO 11201:2010
INTERNATIONAL ISO
STANDARD 11201
Second edition
2010-05-15
Acoustics — Noise emitted by machinery
and equipment — Determination of
emission sound pressure levels at a work
station and at other specified positions in
an essentially free field over a reflecting
plane with negligible environmental
corrections
Acoustique — Bruit émis par les machines et équipements —
Détermination des niveaux de pression acoustique d'émission au poste
de travail et en d'autres positions spécifiées dans des conditions
approchant celles du champ libre sur plan réfléchissant avec des
corrections
Reference number
ISO 11201:2010(E)
©
ISO 2010
---------------------- Page: 7 ----------------------
SIST EN ISO 11201:2010
ISO 11201:2010(E)
PDF disclaimer
This PDF file may contain embedded typefaces. In accordance with Adobe's licensing policy, this file may be printed or viewed but
shall not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In
downloading this file, parties accept therein the responsibility of not infringing Adobe's licensing policy. The ISO Central Secretariat
accepts no liability in this area.
Adobe is a trademark of Adobe Systems Incorporated.
Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation
parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In
the unlikely event that a problem relating to it is found, please inform the Central Secretariat at the address given below.
COPYRIGHT PROTECTED DOCUMENT
© ISO 2010
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means,
electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or
ISO's member body in the country of the requester.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Published in Switzerland
ii © ISO 2010 – All rights reserved
---------------------- Page: 8 ----------------------
SIST EN ISO 11201:2010
ISO 11201:2010(E)
Contents Page
Foreword .iv
Introduction.v
1 Scope.1
2 Normative references.2
3 Terms and definitions .3
4 Instrumentation .7
5 Test environment.7
6 Measured quantities.11
7 Quantities to be determined.12
8 Mounting and operation of source under test.12
9 Microphone positions .14
10 Measurements .16
11 Measurement uncertainty.18
12 Information to be recorded.21
13 Test report.22
Annex A (normative) Allocation of the accuracy grade (1 or 2).23
Annex B (normative) Criteria for background noise for measurements in frequency bands .24
Annex C (informative) Guidance on the development of information on measurement uncertainty .26
Annex D (informative) Principles of the methodology .32
Annex E (informative) Example of a test table.33
Bibliography.34
© ISO 2010 – All rights reserved iii
---------------------- Page: 9 ----------------------
SIST EN ISO 11201:2010
ISO 11201:2010(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies
(ISO member bodies). The work of preparing International Standards is normally carried out through ISO
technical committees. Each member body interested in a subject for which a technical committee has been
established has the right to be represented on that committee. International organizations, governmental and
non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the
International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.
The main task of technical committees is to prepare International Standards. Draft International Standards
adopted by the technical committees are circulated to the member bodies for voting. Publication as an
International Standard requires approval by at least 75 % of the member bodies casting a vote.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. ISO shall not be held responsible for identifying any or all such patent rights.
ISO 11201 was prepared by Technical Committee ISO/TC 43, Acoustics, Subcommittee SC 1, Noise.
This second edition cancels and replaces the first edition (ISO 11201:1995), which has been technically
revised. It also incorporates the Technical Corrigendum ISO 11201:1995/Cor.1:1997.
iv © ISO 2010 – All rights reserved
---------------------- Page: 10 ----------------------
SIST EN ISO 11201:2010
ISO 11201:2010(E)
Introduction
This International Standard specifies a method for determining the emission sound pressure levels at a work
station and at other well defined positions, in the vicinity of a machine or piece of equipment, in an essentially
[15] [19]
free field over a reflecting plane. It is one of a series (ISO 11200 to ISO 11205 ) which specifies various
methods for determining the emission sound pressure level at a work station and at other specified positions
[15]
of a machine or equipment. ISO 11200 gives guidance on the choice of the method to be used to
determine the emission sound pressure levels of machinery and equipment.
The method specified in this International Standard differs from those in other International Standards in the
[15] [19]
ISO 11200 to ISO 11205 series in not applying any environmental correction. Requirements to be
fulfilled by the environment are specified for accuracy grade 1 (precision) and grade 2 (engineering)
measurements indoors and outdoors.
Precision measurements with accuracy grade 1 can generally be carried out in hemi-anechoic test rooms or
outdoors provided that requirements on environmental conditions are met. With the specifications defined in
the following it should be possible in some cases to provide such conditions in industrial ambience on larger
plane areas outdoors free from reflecting objects.
ISO 11201:1995 provided results of accuracy grade 2 only. This edition of this International Standard provides
a method of accuracy grade 2 that is essentially identical to that given in ISO 11201:1995. It also provides a
more precise method of accuracy grade 1. Users and drafters of noise test codes referring to this International
Standard should indicate clearly which method (accuracy grade 1 or accuracy grade 2) is used.
In general, the emission sound pressure levels are less than or equal to those that occur when the machinery
or equipment is operating in its normal surroundings. This is because the sound pressure levels are
determined by excluding the effects of background noise, as well as the effects of reflections other than those
from the reflecting plane on which the machine under test is placed. For determination or calculation of the
sound pressure level at the operator's position with the machine operating in a room, both sound power level
and sound pressure level are required (as well as information on the room properties or reflections and noise
from other sound sources or machines). A method of calculating the sound pressure levels in the vicinity of a
[20]
machine operating alone in a workroom is given in ISO/TR 11690-3 . Commonly observed differences are
1 dB to 5 dB, but in extreme cases the difference may be even greater.
© ISO 2010 – All rights reserved v
---------------------- Page: 11 ----------------------
SIST EN ISO 11201:2010
---------------------- Page: 12 ----------------------
SIST EN ISO 11201:2010
INTERNATIONAL STANDARD ISO 11201:2010(E)
Acoustics — Noise emitted by machinery and equipment —
Determination of emission sound pressure levels at a work
station and at other specified positions in an essentially free
field over a reflecting plane with negligible environmental
corrections
1 Scope
1.1 General
This International Standard specifies a method for determining the emission sound pressure levels of
machinery or equipment, at a work station and at other specified positions nearby, in an essentially free field
over a reflecting plane. A work station is occupied by an operator and may be located in open space, in the
room where the source under test operates, in a cab fixed to the source under test, or in an enclosure remote
from the source under test. One or more specified positions may be located in the vicinity of a work station, or
in the vicinity of an attended or unattended machine. Such positions are sometimes referred to as bystander
positions.
Emission sound pressure levels are determined as A-weighted levels. Additionally, levels in frequency bands
and C-weighted peak emission sound pressure levels can be determined in accordance with this International
Standard, if required.
[15] [19] [15]
NOTE 1 The contents of the series ISO 11200 to ISO 11205 are summarized in ISO 11200 .
With the method specified in this International Standard, results of accuracy grade 1 (precision grade) or
accuracy grade 2 (engineering grade) are obtained. Corrections are applied for background noise, but not for
the acoustic environment. Instructions are given for the mounting and operation of the source under test and
for the choice of microphone positions for the work station and for other specified positions. One purpose of
the measurements is to permit comparison of the performance of different units of a given family of machines,
under defined environmental conditions and standardized mounting and operating conditions.
NOTE 2 The data obtained can also be used for the declaration and verification of emission sound pressure levels as
[8]
specified in ISO 4871 .
1.2 Types of noise and noise sources
The method specified in this International Standard is suitable for all types of noise (steady, non-steady,
fluctuating, isolated bursts of sound energy, etc.) defined in ISO 12001.
The method specified in this International Standard is applicable to all types and sizes of noise sources.
NOTE Throughout this International Standard the words “machine” and “source under test” are used to represent
either a machine or a piece of equipment.
© ISO 2010 – All rights reserved 1
---------------------- Page: 13 ----------------------
SIST EN ISO 11201:2010
ISO 11201:2010(E)
1.3 Test environment
The type of test environment influences the accuracy of the determination of emission sound pressure levels.
For the application of this International Standard, an essentially free field over a reflecting plane (indoors or
outdoors) is required.
1.4 Work station and other specified positions
This International Standard is applicable to work stations and other specified positions where emission sound
pressure levels are to be determined.
Appropriate positions where measurements may be made include the following:
a) work station located in the vicinity of the source under test; this is the case for many industrial machines
and domestic appliances;
b) work station within a cab which is an integral part of the source under test; this is the case for many
industrial trucks and earth-moving machines;
c) work station within a partial or total enclosure (or behind a screen) supplied by the manufacturer as an
integral part of the source under test;
d) work station partially or totally enclosed by the source under test — this situation may be encountered
with some large industrial machines;
e) bystander positions occupied by individuals not responsible for the operation of the source under test, but
who may be in its immediate vicinity, either occasionally or continuously;
f) other specified positions, not necessarily work stations or bystander positions.
The work station may also lie on a specified path along which an operator moves (see 9.4).
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
ISO 3744, Acoustics — Determination of sound power levels of noise sources using sound pressure —
Engineering method in an essentially free field over a reflecting plane
ISO 3745, Acoustics — Determination of sound power levels of noise sources using sound pressure —
Precision methods for anechoic and hemi-anechoic rooms
ISO 3746, Acoustics — Determination of sound power levels of noise sources using sound pressure —
Survey method using an enveloping measurement surface over a reflecting plane
ISO 5725 (all parts), Accuracy (trueness and precision) of measurement methods and results
ISO 12001, Acoustics — Noise emitted by machinery and equipment — Rules for the drafting and
presentation of a noise test code
IEC 60942:2003, Electroacoustics — Sound calibrators
IEC 61260:1995, Electroacoustics — Octave-band and fractional-octave-band filters (amended by
IEC 61260/Amd.1:2001)
2 © ISO 2010 – All rights reserved
---------------------- Page: 14 ----------------------
SIST EN ISO 11201:2010
ISO 11201:2010(E)
IEC 61672-1:2002, Electroacoustics — Sound level meters — Part 1: Specifications
ISO/IEC Guide 98-3:2008, Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in
measurement (GUM:1995)
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply. More detailed definitions can be
found in noise test codes for specific types of machines.
3.1
emission
〈acoustics〉 airborne sound radiated by a well-defined noise source (e.g. the machine under test)
NOTE Noise emission descriptors can be incorporated into a product label and/or product specification. The basic
noise emission descriptors are the sound power level of the source itself and the emission sound pressure levels at a work
station and/or at other specified positions (if any) in the vicinity of the source.
3.2
emission sound pressure
p
sound pressure, at a work station or another specified position near a noise source, when the source is in
operation under specified operating and mounting conditions on a reflecting plane surface, excluding the
effects of background noise as well as the effects of reflections other than those from the plane or planes
permitted for the purpose of the test
NOTE Emission sound pressure is expressed in pascals.
3.3
emission sound pressure level
L
p
ten times the logarithm to the base 10 of the ratio of the square of the emission sound pressure, p, to the
square of a reference value, p , expressed in decibels
0
2
p
L = 10lg dB (1)
p
2
p
0
where the reference value, p , is 20 µPa
0
NOTE The emission sound pressure level is determined at a work station or another specified position in accordance
with either a noise test code for a specific family of machines or, if no noise test code exists, one of the standards of the
[15] [19]
ISO 11200 to ISO 11205 series.
3.4
time-averaged emission sound pressure level
L
p,T
ten times the logarithm to the base 10 of the ratio of the time average of the square of the emission sound
pressure, p, during a stated time interval of duration, T (starting at t and ending at t ), to the square of a
1 2
reference value, p , expressed in decibels
0
t
⎡⎤2
1
2
⎢⎥
pt()dt
∫
⎢⎥
T
t
1
⎢⎥
L = 10lg dB (2)
pT,
⎢⎥2
p
0
⎢⎥
⎢⎥
⎢⎥
⎣⎦
where the reference value, p , is 20 µPa
0
© ISO 2010 – All rights reserved 3
---------------------- Page: 15 ----------------------
SIST EN ISO 11201:2010
ISO 11201:2010(E)
[21]
NOTE 1 Adapted from ISO/TR 25417:2007 , 2.3, “time-averaged sound pressure level”.
NOTE 2 For simplicity of notation, the subscript T is omitted throughout the following text.
NOTE 3 If specific frequency and time weightings as specified in IEC 61672-1 and/or specific frequency bands are
applied, this is indicated by appropriate subscripts; e.g. L denotes the A-weighted emission sound pressure level.
pA
NOTE 4 Equation (2) is equivalent to that for the environmental noise descriptor “equivalent continuous sound pressure
[1]
level” (ISO 1996-1 ). However, the emission quantity defined above is used to characterize the noise emitted by a source
under test and assumes that standardized measurement and operating conditions as well as a controlled acoustical
environment are used for the measurements.
3.5
peak emission sound pressure
p
peak
greatest absolute emission sound pressure during a stated time interval
NOTE 1 Peak emission sound pressure is expressed in pascals.
NOTE 2 A peak emission sound pressure may arise from a positive or negative sound pressure.
3.6
peak emission sound pressure level
L
p,peak
ten times the logarithm to the base 10 of the ratio of the square of the peak emission sound pressure, p , to
peak
the square of a reference value, p , expressed in decibels
0
2
p
peak
L = 10lg dB (3)
p,peak
2
p
0
where the reference value, p , is 20 µPa
0
NOTE The peak emission sound pressure level is usually C-weighted and denoted by L .
pC,peak
3.7
single event emission sound pressure level
L
E
ten times the logarithm to the base 10 of the ratio of the integral of the square of the emission sound pressure,
p, of an isolated single sound event (burst of sound or transient sound) of specified duration, T (or specified
measurement time interval T = t – t covering the single event), to the square of a reference value, p ,
2 1 0
normalized to reference time interval T = 1 s, expressed in decibels
0
t
⎡⎤
2
2
1(pt)
⎢⎥
Lt= 10lg d dB
E
∫
2
⎢⎥
T
p
0
0
t
⎢⎥ (4)
⎣⎦1
T
=+L 10lg dB
pT,
T
0
NOTE Equation (4) is equivalent to that for the environmental noise descriptor “sound exposure level”
[21]
(ISO/TR 25417:2007 , 2.7). However, the emission quantity defined above is used to characterize the noise emitted by a
source under test and assumes that standardized measurement, mounting, and operating conditions as well as a
controlled acoustical environment are used for the measurements.
4 © ISO 2010 – All rights reserved
---------------------- Page: 16 ----------------------
SIST EN ISO 11201:2010
ISO 11201:2010(E)
3.8
acoustic free field over a reflecting plane
sound field in a homogeneous, isotropic medium in the half space above an infinite reflecting plane, in the
absence of any other obstacles
3.9
essentially free field over a reflecting plane
environment approximating an acoustic free field over a reflecting plane on which the noise source under test
is located
NOTE The requirements on the environment are specified in 5.2.
3.10
frequency range of interest
for general purposes, the frequency range of octave bands with nominal mid-band frequencies from 125 Hz to
8 000 Hz or the one-third octave bands with nominal mid-band frequencies from 100 Hz to 10 000 Hz
[9]
NOTE 1 Adapted from ISO 6926:1999 , 3.10.
NOTE 2 For special purposes, the frequency range may be extended or reduced, provided that the test environment
and instrument specifications are satisfactory for use over the modified frequency range. Changes to the frequency range
of interest should be made clear in the test report. For sources which emit sound at predominantly high or low frequencies,
the frequency range of interest should be extended to include these frequencies.
3.11
work station
operator's position
position in the vicinity of the machine under test which is intended for the operator
3.12
operator
individual whose work station is in the vicinity of a machine and who is performing a work task associated with
that machine
3.13
specified position
position defined in relation to a machine, including, but not limited to, an operator's position
NOTE 1 The position can be a single, fixed point, or a combination of points along a path or on a surface located at a
specified distance from the machine, as descri
...
Questions, Comments and Discussion