Safety of machinery - Evaluation of the emission of airborne hazardous substances - Part 6: Separation efficiency by mass, unducted outlet

This European Standard specifies a test rig method for the measurement of the separation efficiency by mass of air cleaning systems with unducted outlet, operating under defined conditions. The method shall apply to systems that clean air of aerosols (smoke, dust, fume, mist), vapour or gas.
Measurement of the separation efficiency by mass of an air cleaning system for an intended use can serve for the:
a)   evaluation of the performance of an air cleaning system;
b)   evaluation of the improvement of the air cleaning system;
c)   comparison of air cleaning systems;
d)   ranking of air cleaning systems according to their separation efficiency by mass;
e)   determination of the state of the art of air cleaning systems of the same intended use with respect to their separation efficiency by mass.

Sicherheit von Maschinen - Bewertung der Emission von luftgetragenen Gefahrstoffen - Teil 6: Masseabscheidegrad, diffuser Auslass

Sécurité des machines - Evaluation de l'émission de substances dangereuses véhiculées par l'air - Partie 6: Efficacité massique de séparation, sortie libre

Cette norme européenne spécifie une méthode de mesurage sur banc d'essai de l'efficacité massique de séparation
des épurateurs d'air fonctionnant dans des conditions définies. Cette méthode doit s'appliquer aux séparateurs
d’aérosols (poussières, fumées, brouillards ), de vapeurs ou de gaz.
Le mesurage de l'efficacité massique de séparation d'un épurateur d'air pour une utilisation normale peut être
utilisé pour :
a) l'évaluation des performances d'un épurateur ;
b) l'évaluation des améliorations apportées à cet épurateur ;
c) la comparaison de différents épurateurs ;
d) le classement des épurateurs en fonction de l'efficacité massique de séparation ;
e) la détermination de l'état de la technique des épurateurs d'air pour ce qui concerne leur efficacité massique
de séparation.

Varnost strojev - Vrednotenje emisije nevarnih snovi, ki jih prenaša zrak - 6. del: Učinkovitost ločitve po masi, nekanaliziran izpuh

General Information

Status
Published
Publication Date
02-Nov-2008
Technical Committee
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
29-Oct-2008
Due Date
03-Jan-2009
Completion Date
03-Nov-2008

Relations

Buy Standard

Standard
EN 1093-6:2000+A1:2008
English language
11 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Sicherheit von Maschinen - Bewertung der Emission von luftgetragenen Gefahrstoffen - Teil 6: Masseabscheidegrad, diffuser AuslassSécurité des machines - Evaluation de l'émission de substances dangereuses véhiculées par l'air - Partie 6: Efficacité massique de séparation, sortie libreSafety of machinery - Evaluation of the emission of airborne hazardous substances - Part 6: Separation efficiency by mass, unducted outlet13.110Varnost strojevSafety of machinery13.040.40Stationary source emissionsICS:Ta slovenski standard je istoveten z:EN 1093-6:1998+A1:2008SIST EN 1093-6:2000+A1:2008en,fr,de01-december-2008SIST EN 1093-6:2000+A1:2008SLOVENSKI
STANDARD



SIST EN 1093-6:2000+A1:2008



EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 1093-6:1998+A1
July 2008 ICS 13.040.40 Supersedes EN 1093-6:1998 English Version
Safety of machinery - Evaluation of the emission of airborne hazardous substances - Part 6: Separation efficiency by mass, unducted outlet
Sécurité des machines - Evaluation de l'émission de substances dangereuses véhiculées par l'air - Partie 6: Efficacité massique de séparation, sortie libre
Sicherheit von Maschinen - Bewertung der Emission von luftgetragenen Gefahrstoffen - Teil 6: Masseabscheidegrad, diffuser Auslass This European Standard was approved by CEN on 4 September 1998 and includes Amendment 1 approved by CEN on 8 June 2008.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: rue de Stassart, 36
B-1050 Brussels © 2008 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 1093-6:1998+A1:2008: ESIST EN 1093-6:2000+A1:2008



EN 1093-6:1998+A1:2008 (E) 2 Contents Page Foreword.3 Introduction.4 1 Scope.4 2 Normative references.4 3 Definitions.5 4 Principle.5 5 Description of the test rig.5 6 Position and operation of the air cleaning system.6 7 Procedure.7 8 Expression of results.7 9 Test report.8 Annex ZA (informative)
!Relationship between this European Standard and the Essential Requirements of EU Directive 98/37/EC".9 Annex ZB (informative)
!Relationship between this European Standard and the Essential Requirements of EU Directive 2006/42/EC".10 Bibliography.11
SIST EN 1093-6:2000+A1:2008



EN 1093-6:1998+A1:2008 (E) 3 Foreword This document (EN 1093-6:1998+A1:2008) has been prepared by Technical Committee CEN/TC 114 "Safety of machinery", the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by January 2009, and conflicting national standards shall be withdrawn at the latest by December 2009. This document includes Amendment 1, approved by CEN on 2008-06-08. This document supersedes EN 1093-6:1998. The start and finish of text introduced or altered by amendment is indicated in the text by tags ! ". This European Standard has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirements of EU Directive(s). !For relationship with EU Directive(s), see informative Annexes ZA and ZB, which are integral parts of this document." According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. SIST EN 1093-6:2000+A1:2008



EN 1093-6:1998+A1:2008 (E) 4 Introduction This European Standard is a type B standard as stated in ENV 1070: 1993. This European Standard is a part of EN 1093. Part 1 of this standard presents a selection of different methods for the evaluation of the emission of airborne hazardous substances from machines. 1 Scope This European Standard specifies a test rig method for the measurement of the separation efficiency by mass of air cleaning systems with unducted outlet, operating under defined conditions. The method shall apply to systems that clean air of aerosols (smoke, dust, fume, mist), vapour or gas. Measurement of the separation efficiency by mass of an air cleaning system for an intended use can serve for the: a) evaluation of the performance of an air cleaning system; b) evaluation of the improvement of the air cleaning system; c) comparison of air cleaning systems; d) ranking of air cleaning systems according to their separation efficiency by mass; e) determination of the state of the art of air cleaning systems of the same intended use with respect to their separation efficiency by mass. 2 Normative references This European Standard incorporates by dated or undated reference, provisions from other publications. These normative references are cited at the appropriate places in the text and the publications are listed hereafter. For dated references, subsequent amendments to or revisions of any of these publications apply to this European Standard only when incorporated in it by amendment or revision. For undated references the latest edition of the publication referred to applies. EN 292-1:1991, Safety of machinery - Basic concepts, general principles for design - Part 1: Basic terminology, methodology. EN 292-2:1991, Safety of machinery - Basic concepts, general principles for design - Part 2: Technical principles and specifications. EN 292-2/A1:1995, Safety of machinery - Basic concepts, general principles for design - Part 2: Technical principles and specifications; Amendment A1. ENV 1070:1993, Safety of machinery – Terminology. prEN 1093-1, Safety of machinery - Evaluation of the emission of airborne hazardous substances - Part 1: Selection of test methods.
SIST EN 1093-6:2000+A1:2008



EN 1093-6:1998+A1:2008 (E) 5 3 Definitions For the purposes of this European Standard the definitions of ENV 1070:1993 and the following definition applies: 3.1 separation efficiency by mass s the separation efficiency of an air cleaning system for a specified pollutant is the ratio of the mass of pollutant retained by the air cleaning system (m3) to the mass of pollutant entering the air cleaning system (m1) during a given period.
The separation efficiency of an air cleaning system as a percentage is expressed as follows: 10013⋅=mmsη (1) 4 Principle The principle of the measurement method is to operate the air cleaning system under defined conditions in a test rig and to determine the mass of the test substance in the air upstr
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.