SIST EN IEC 61347-2-1:2024
(Main)Controlgear for electric light sources - Safety - Part 2-1: Particular requirements - Starting devices (other than glow starters) (IEC 61347-2-1:2024)
Controlgear for electric light sources - Safety - Part 2-1: Particular requirements - Starting devices (other than glow starters) (IEC 61347-2-1:2024)
IEC 61347-2-1:2024 is available as IEC 61347-2-1:2024 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 61347-2-1:2024 specifies safety requirements for starting devices (starters other than glow starters and ignitors) for fluorescent and other discharge lamps for use on AC supplies up to 1 000 V at 50 Hz or 60 Hz which produce starting pulses not greater than 100 kV and which are used in combination with lamps and controlgear covered in IEC 60081, IEC 60188, IEC 60192, IEC 60662, IEC 60901, IEC 61167, IEC 61195, IEC 61199, IEC 61347-2-8 and IEC 61347-2-9.
This second edition cancels and replaces the first edition published in 2000, Amendment 1:2005 and Amendment 2:2013. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) update of normative references, introducing dated references where appropriate;
b) clarification of sample item numbers;
c) alignment of clause numbers with those of IEC 61347-1;
d) renumbering of Clause 15 and Clause 16.
Betriebsgeräte für elektrische Lichtquellen - Sicherheit - Teil 2-1: Besondere Anforderungen - Startgeräte (andere als Glimmstarter) (IEC 61347-2-1:2024)
Appareillages de commande pour les sources de lumière électriques - Sécurité - Partie 2-1: Exigences particulières - Dispositifs d'amorçage (autres que starters à lueur) (IEC 61347-2-1:2024)
IEC 61347-2-1:2024 est disponible sous forme de IEC 61347-2-1:2024 RLV qui contient la Norme internationale et sa version Redline, illustrant les modifications du contenu technique depuis l'édition précédente.
L'IEC 61347-2-1:2024 spécifie les exigences de sécurité des dispositifs d'amorçage (starters autres que starters à lueur et amorceurs) pour lampes fluorescentes et autres lampes à décharge qui sont destinés à être utilisés avec des alimentations jusqu'à 1 000 V en courant alternatif à 50 Hz ou 60 Hz qui produisent des impulsions d'amorçage inférieures ou égales à 100 kV et qui sont associés aux lampes et appareillages spécifiés dans l'IEC 60081, l'IEC 60188, l'IEC 60192, l'IEC 60662, l'IEC 60901, l'IEC 61167, l'IEC 61195, l'IEC 61199, l'IEC 61347-2-8 et l'IEC 61347-2-9.
Cette seconde édition annule et remplace la première édition parue en 2000, l'Amendement 1:2005 et l'Amendement 2:2013. Cette édition constitue une révision technique.
Cette édition inclut les modifications techniques majeures suivantes par rapport à l'édition précédente:
a) mise à jour des références normatives, avec ajout de références datées le cas échéant;
b) clarification des numéros d'entités d'échantillonnage;
c) alignement des numéros d'articles sur ceux de l'IEC 61347-1;
d) renumérotation de l'Article 15 et de l'Article 16.
Stikalne naprave za sijalke - Varnost - 2-1. del: Posebne zahteve - Vžigne naprave (razen tlivnih starterjev) (IEC 61347-2-1:2024)
Ta del standarda IEC 61347 določa varnostne zahteve za vžigne naprave (razen tlivnih starterjev in sprožilcev) za fluorescenčne in druge razelektritvene sijalke za uporabo z izmeničnim napajanjem do 1000 V pri 50 Hz ali 60 Hz, ki proizvajajo vžigne impulze nad 100 kV ter se uporabljajo v kombinaciji s sijalkami in stikalno opremo iz standardov IEC 60081, IEC 60188, IEC 60192, IEC 60662, IEC 60901, IEC 61167, IEC 61195, IEC 61199, IEC 61347-2-8 in IEC 61347-2-9.
Ta dokument se ne uporablja za tlivne starterje oziroma vžigne naprave, ki so vgrajene v razelektritvene sijalke ali se jih upravlja ročno.
OPOMBA 1: Tlivni starterji so obravnavani v standardu IEC 60155.
OPOMBA 2: Tehnične zahteve so podane v standardu IEC 60927.
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
01-september-2024
Stikalne naprave za sijalke - Varnost - 2-1. del: Posebne zahteve - Vžigne naprave
(razen tlivnih starterjev) (IEC 61347-2-1:2024)
Controlgear for electric light sources - Safety - Part 2-1: Particular requirements -
Starting devices (other than glow starters) (IEC 61347-2-1:2024)
Betriebsgeräte für elektrische Lichtquellen - Sicherheit - Teil 2-1: Besondere
Anforderungen - Startgeräte (andere als Glimmstarter) (IEC 61347-2-1:2024)
Appareillages de commande pour les sources de lumière électriques - Sécurité - Partie 2
-1: Exigences particulières - Dispositifs d'amorçage (autres que starters à lueur) (IEC
61347-2-1:2024)
Ta slovenski standard je istoveten z: EN IEC 61347-2-1:2024
ICS:
29.130.01 Stikalne in krmilne naprave Switchgear and controlgear
na splošno in general
29.140.99 Drugi standardi v zvezi z Other standards related to
žarnicami lamps
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD EN IEC 61347-2-1
NORME EUROPÉENNE
EUROPÄISCHE NORM June 2024
ICS 29.140.99 Supersedes EN 61347-2-1:2001;
EN 61347-2-1:2001/corrigendum Jul. 2003;
EN 61347-2-1:2001/A1:2006;
EN 61347-2-1:2001/A1:2006/corrigendum Nov. 2006;
EN 61347-2-1:2001/corrigendum Dec. 2010;
EN 61347-2-1:2001/A2:2014
English Version
Controlgear for electric light sources - Safety - Part 2-1:
Particular requirements - Starting devices (other than glow
starters)
(IEC 61347-2-1:2024)
Appareillages de commande pour les sources de lumière Betriebsgeräte für elektrische Lichtquellen - Sicherheit - Teil
électriques - Sécurité - Partie 2-1: Exigences particulières - 2-1: Besondere Anforderungen - Startgeräte (andere als
Dispositifs d'amorçage (autres que starters à lueur) Glimmstarter)
(IEC 61347-2-1:2024) (IEC 61347-2-1:2024)
This European Standard was approved by CENELEC on 2024-06-18. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the
Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Türkiye and the United Kingdom.
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2024 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN IEC 61347-2-1:2024 E
European foreword
The text of document 34C/1582/CDV, future edition 2 of IEC 61347-2-1, prepared by SC 34C
"Auxiliaries for lamps" of IEC/TC 34 "Lighting" was submitted to the IEC-CENELEC parallel vote and
approved by CENELEC as EN IEC 61347-2-1:2024.
The following dates are fixed:
• latest date by which the document has to be implemented at national (dop) 2025-03-18
level by publication of an identical national standard or by endorsement
• latest date by which the national standards conflicting with the (dow) 2027-06-18
document have to be withdrawn
This document supersedes EN 61347-2-1:2001 and all of its amendments and corrigenda (if any).
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC shall not be held responsible for identifying any or all such patent rights.
This document is read in conjunction with EN 61347-1:2015 and EN 61347-1:2015/A1:2021.
This document has been prepared under a standardization request addressed to CENELEC by the
European Commission. The Standing Committee of the EFTA States subsequently approves these
requests for its Member States.
Any feedback and questions on this document should be directed to the users’ national committee. A
complete listing of these bodies can be found on the CENELEC website.
Endorsement notice
The text of the International Standard IEC 61347-2-1:2024 was approved by CENELEC as a
European Standard without any modification.
In the official version, for Bibliography, the following notes have to be added for the standard indicated:
IEC 60188 NOTE Approved as EN 60188
IEC 60192 NOTE Approved as EN 60192
IEC 60662 NOTE Approved as EN 60662
IEC 60927 NOTE Approved as EN 60927
IEC 61167 NOTE Approved as EN 61167
IEC 61195 NOTE Approved as EN 61195
IEC 61199 NOTE Approved as EN 61199
IEC 61347-2-1:2000 NOTE Approved as EN 61347-2-1:2001 (not modified)
IEC 61347-2-1:2000/A1:2005 NOTE Approved as EN 61347-2-1:2001/A1:2006 (not modified)
IEC 61347-2-1:2000/A2:2013 NOTE Approved as EN 61347-2-1:2001/A2:2014 (not modified)
IEC 61347-2-8 NOTE Approved as EN 61347-2-8
IEC 61347-2-9 NOTE Approved as EN 61347-2-9
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments)
applies.
NOTE 1 Where an International Publication has been modified by common modifications, indicated by (mod),
the relevant EN/HD applies.
NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is available
here: www.cencenelec.eu.
Publication Year Title EN/HD Year
IEC 60052 2002 Voltage measurement by means of EN 60052 2002
standard air gaps
IEC 60068-2-75 2014 Environmental testing - Part 2-75: Tests - EN 60068-2-75 2014
Test Eh: Hammer tests
IEC 60081 - Double-capped fluorescent lamps - EN 60081 -
Performance specifications
IEC 60155 1993 Glow-starters for fluorescent lamps EN 60155 1995
+ A1 1995 + A1 1995
+ A2 2006 + A2 2007
1 1
IEC 60255-8 1990 Electrical relays -- Part 8: Thermal EN 60255-8 1998
electrical relays
IEC 60598 series Luminaires EN IEC 60598 series
IEC 60598-1 2020 Luminaires - Part 1: General requirements EN IEC 60598-1 2021
and tests
IEC 60901 - Single-capped fluorescent lamps - EN 60901 -
Performance specifications
IEC 61347-1 2015 Lamp controlgear - Part 1: General and EN 61347-1 2015
safety requirements
+ A1 2017 + A1 2021
ISO 3864 series Graphical symbols - Safety colours and - series
safety signs
Withdrawn.
IEC 61347-2-1 ®
Edition 2.0 2024-05
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Controlgear for electric light sources – Safety –
Part 2-1: Particular requirements – Starting devices (other than glow starters)
Appareillages de commande pour les sources de lumière électriques – Sécurité –
Partie 2-1: Exigences particulières – Dispositifs d'amorçage (autres que starters
à lueur)
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
INTERNATIONALE
ICS 29.140.99 ISBN 978-2-8322-8840-5
– 2 – IEC 61347-2-1:2024 © IEC 2024
CONTENTS
FOREWORD . 4
INTRODUCTION . 6
1 Scope . 7
2 Normative references . 7
3 Terms and definitions . 8
4 General requirements . 9
5 General notes on tests . 9
6 Classification . 9
7 Marking . 10
7.1 Marking and information . 10
7.1.1 Mandatory marking . 10
7.1.2 Information to be provided . 10
7.2 Durability and legibility . 10
8 Terminals . 10
9 Earthing . 10
10 Protection against accidental contact with live parts . 10
11 Moisture resistance and insulation . 11
12 Electric strength . 11
13 Thermal endurance test for windings of ballasts . 11
14 Fault conditions . 11
15 Pulse voltage of ignitors . 12
16 Heating of built-in and independent starting devices . 14
16.1 General . 14
16.2 Normal operation . 14
16.2.1 General . 14
16.2.2 Normal operation of built-in starting devices . 14
16.2.3 Normal operation of independent starting devices . 15
16.3 Abnormal operation . 15
16.3.1 Abnormal operation of built-in ignitors. 15
16.3.2 Abnormal operation of built-in starters . 16
16.3.3 Abnormal operation of independent starting devices . 16
17 Mechanical strength . 17
18 Construction . 18
19 Creepage distances and clearances . 18
20 Screws, current-carrying parts and connections . 18
21 Resistance to heat, fire and tracking . 19
22 Resistance to corrosion . 19
23 Applicable annexes of IEC 61347-1 . 19
Annex A (normative) Mechanical strength testing . 20
A.1 Replaceable starting devices and accessible components over 100 g . 20
A.2 Replaceable starting devices and accessible components up to 100 g . 20
Annex B (informative) Precautions to be observed when measuring with sphere-gaps . 22
B.1 General . 22
B.2 Sphere-gap . 22
IEC 61347-2-1:2024 © IEC 2024 – 3 –
B.3 Breakdown gap distance . 22
B.4 Duty cycle of the ignitor . 22
B.5 End of test . 22
Annex C (informative) Schedule of more onerous requirements . 23
Bibliography . 24
Figure 1 – Starting voltage measurement for ignitors . 13
Figure A.1 – Tumbling barrel . 21
– 4 – IEC 61347-2-1:2024 © IEC 2024
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
CONTROLGEAR FOR ELECTRIC LIGHT SOURCES – SAFETY –
Part 2-1: Particular requirements – Starting devices
(other than glow starters)
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international
co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and
in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports,
Publicly Available Specifications (PAS) and Guides (hereafter referred to as "IEC Publication(s)"). Their
preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with
may participate in this preparatory work. International, governmental and non-governmental organizations liaising
with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for
Standardization (ISO) in accordance with conditions determined by agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence between
any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) IEC draws attention to the possibility that the implementation of this document may involve the use of (a)
patent(s). IEC takes no position concerning the evidence, validity or applicability of any claimed patent rights in
respect thereof. As of the date of publication of this document, IEC had not received notice of (a) patent(s), which
may be required to implement this document. However, implementers are cautioned that this may not represent
the latest information, which may be obtained from the patent database available at https://patents.iec.ch. IEC
shall not be held responsible for identifying any or all such patent rights.
IEC 61347-2-1 has been prepared by subcommittee 34C: Auxiliaries for lamps, of IEC technical
committee 34: Lighting. It is an International Standard.
This second edition cancels and replaces the first edition published in 2000, Amendment 1:2005
and Amendment 2:2013. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous
edition:
a) update of normative references, introducing dated references where appropriate;
b) clarification of sample item numbers;
c) alignment of clause numbers with those of IEC 61347-1;
d) renumbering of Clause 15 and Clause 16.
IEC 61347-2-1:2024 © IEC 2024 – 5 –
The text of this International Standard is based on the following documents:
Draft Report on voting
34C/1582/CDV 34C/1590/RVC
Full information on the voting for its approval can be found in the report on voting indicated in
the above table.
The language used for the development of this International Standard is English.
This document was drafted in accordance with ISO/IEC Directives, Part 2, and developed in
accordance with ISO/IEC Directives, Part 1 and ISO/IEC Directives, IEC Supplement, available
at www.iec.ch/members_experts/refdocs. The main document types developed by IEC are
described in greater detail at www.iec.ch/publications.
This document is intended to be used in conjunction with IEC 61347-1:2015 and
IEC 61347-1:2015/AMD1:2017. Where the requirements of any of the clauses of
IEC 61347-1:2015 and IEC 61347-1:2015/AMD1:2017 are referred to in this document by the
phrase "IEC 61347-1:2015, Clause n and IEC 61347-1:2015/AMD1:2017, Clause n apply", this
phrase is interpreted as meaning that all the requirements of the clause in question of
IEC 61347-1:2015 and IEC 61347-1:2015/AMD1:2017 apply, except any which are clearly
inapplicable to the specific type of controlgear covered by this document.
NOTE In this document, the following print type is used:
– compliance statements: in italic type.
A list of all parts in the IEC 61347 series, published under the general title Controlgear for
electric light sources – Safety, can be found on the IEC website.
Future documents in this series will carry the new general title as cited above. Titles of existing
documents in this series will be updated at the time of the next edition.
The committee has decided that the contents of this document will remain unchanged until the
stability date indicated on the IEC website under webstore.iec.ch in the data related to the
specific document. At this date, the document will be
• reconfirmed,
• withdrawn, or
• revised.
– 6 – IEC 61347-2-1:2024 © IEC 2024
INTRODUCTION
The technical requirements in this document compared to IEC 61347-2-1:2000,
IEC 61347-2-1:2000/AMD1:2005 and IEC 61347-2-1:2000/AMD2:2013 are essentially
unchanged. Nevertheless, a new edition of this document could not be avoided, as without the
introduction of dated references to IEC 61347-1:2015 and IEC 61347-1:2015/AMD1:2017, the
fourth edition of IEC 61347-1:— would have been implicitly applicable due to the undated
nature of the references to IEC 61347-1 in IEC 61347-2-1:2000,
IEC 61347-2-1:2000/AMD1:2005 and IEC 61347-2-1:2000/AMD2:2013.
This document, in referring to any of the clauses of IEC 61347-1:2015 and
IEC 61347-1:2015/AMD1:2017, specifies the extent to which such a clause is applicable.
Additional requirements are also included, as necessary.
___________
Fourth edition under preparation. Stage at the time of publication IEC FDIS 61347-1:2024.
IEC 61347-2-1:2024 © IEC 2024 – 7 –
CONTROLGEAR FOR ELECTRIC LIGHT SOURCES – SAFETY –
Part 2-1: Particular requirements – Starting devices
(other than glow starters)
1 Scope
This part of IEC 61347 specifies safety requirements for starting devices (starters other than
glow starters and ignitors) for fluorescent and other discharge lamps for use on AC supplies up
to 1 000 V at 50 Hz or 60 Hz which produce starting pulses not greater than 100 kV and which
are used in combination with lamps and controlgear covered in IEC 60081, IEC 60188,
IEC 60192, IEC 60662, IEC 60901, IEC 61167, IEC 61195, IEC 61199, IEC 61347-2-8 and
IEC 61347-2-9.
This document does not apply to glow starters or starting devices which are incorporated in
discharge lamps or which are manually operated.
NOTE 1 Glow starters are dealt with in IEC 60155.
NOTE 2 Performance requirements are given in IEC 60927.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies.
For undated references, the latest edition of the referenced document (including any
amendments) applies.
IEC 60052:2002, Voltage measurement by means of standard air gaps
IEC 60068-2-75:2014, Environmental testing – Part 2-75: Tests – Test Eh: Hammer tests
IEC 60081, Double-capped fluorescent lamps – Performance specifications
IEC 60155:1993, Glow-starters for fluorescent lamps
IEC 60155:1993/AMD1:1995
IEC 60155:1993/AMD2:2006
IEC 60255-8:1990 , Electrical relays – Part 8: Thermal electrical relays
IEC 60598 (all parts), Luminaires
IEC 60598-1:2020, Luminaires – Part 1: General requirements and tests
IEC 60901, Single-capped fluorescent lamps – Performance specifications
IEC 61347-1:2015, Lamp controlgear – Part 1: General and safety requirements
IEC 61347-1:2015/AMD1:2017
___________
Withdrawn.
– 8 – IEC 61347-2-1:2024 © IEC 2024
ISO 3864 (all parts), Graphical symbols – Safety colours and safety signs
3 Terms and definitions
For the purposes of this document, the terms and definitions given in IEC 61347-1 and the
following apply.
ISO and IEC maintain terminology databases for use in standardization at the following
addresses:
• IEC Electropedia: available at https://www.electropedia.org/
• ISO Online browsing platform: available at https://www.iso.org/obp
3.1
starting device
ignitor
device designed to provide the appropriate electrical conditions to start a discharge lamp by
itself or in combination with other components in the circuit
[SOURCE: IEC 60500-845:2020, 845-28-041, modified – The admitted term "ignitor" has been
added.]
3.2
starter
device, usually for fluorescent lamps, which is used for the purpose of starting the discharge
lamp by providing the necessary preheating of the cathode and, in combination with the series
inductance of the ballast, causes a voltage surge applied to the discharge lamp
Note 1 to entry: The starter element that releases the starting voltage pulse can be either triggered or non-triggered.
[SOURCE: IEC 60500-845:2020, 845-28-042]
3.3
starting device with operating time limitation
starting device which prevents prolonged attempts to start lamps which refuse to start, for
example, lamps with deactivated electrodes
Note 1 to entry: Prevention of starting attempts means that in the case of starters, the starting-current circuit is
switched off or the current in the starting circuit is limited to a value equal to or smaller than the rated lamp current.
In the case of ignitors, prevention of starting attempts means that pulse generation has ceased, or voltage pulses
are significantly reduced in amplitude.
3.4
peak voltage
highest value of the voltage pulses generated by an ignitor at the output terminals
3.5
spherical spark gap
two metal spheres of the same diameter arranged at a specified distance and used under
specified conditions for the measurement of peak voltages in excess of 15 kV
3.6
maximum case temperature under abnormal conditions
(t + X)
c
maximum allowable case temperature of the starting devices and ignitors under abnormal
conditions with metal halide lamps
Note 1 to entry: The value of (t + X) is declared by the manufacturer.
c
IEC 61347-2-1:2024 © IEC 2024 – 9 –
3.7
sample
one or more sampling items intended to provide information on the population or on the material
provided by the manufacturer or responsible vendor
[SOURCE: IEC 60050-151:2001, 151-16-19, modified – "provided by the manufacturer or
responsible vendor" has been added.]
3.8
sample item
one of the individual items in a population of similar items, or a portion of material forming a
cohesive entity and taken from one place and at one time
[SOURCE: IEC 60050-151:2001, 151-16-18]
4 General requirements
IEC 61347-1:2015, Clause 4 applies.
5 General notes on tests
IEC 61347-1:2015, Clause 5 applies, together with the following:
– IEC 61347-1:2015, Annex H applies.
– One sample item shall be used for all tests, unless otherwise specified in the corresponding
clause.
To allow for parallel testing and reduced test times, additional sample items may be used
except where the outcome of the test can be affected by preceding tests, for example the
tests of Clause 11 and Clause 12.
– Specially prepared sample items may be used where required.
– Starting devices intended for use with lamps having different electrical characteristics are
tested with the lamp which gives the most unfavourable conditions.
For information on requalification of products compliant with the previous edition of this
document, i.e. IEC 61347-2-1:2000, IEC 61347-2-1:2000/AMD1:2005 and
IEC 61347-2-1:2000/AMD2:2013, refer to Annex C.
6 Classification
IEC 61347-1:2015, Clause 6 applies.
Additionally, starting devices shall be classified as one of the following:
– output voltage up to and including 5 kV;
– output voltage greater than 5 kV, and up to and including 10 kV;
– output voltage greater than 10 kV, and up to and including 100 kV.
SI
...








Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...