SIST EN 61326-2-3:2013
(Main)Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-3: Particular requirements - Test configuration, operational conditions and performance criteria for transducers with integrated or remote signal conditioning (IEC 61326-2-3:2012)
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-3: Particular requirements - Test configuration, operational conditions and performance criteria for transducers with integrated or remote signal conditioning (IEC 61326-2-3:2012)
In addition to the requirements of IEC 61326-1, this part specifies more detailed test configurations, operational conditions and performance criteria for transducers with integrated or remote signal conditioning. This standard applies only to transducers characterized by their ability to transform, with the aid of an auxiliary energy source, a non-electric quantity to a process-relevant electrical signal, and to output the signal at one or more ports. This standard includes transducers for electrochemical and biological measured quantities. The transducers covered by this standard may be powered by a.c. or d.c. voltage and/or by battery or with internal power supply. Transducers referred to by this standard comprise at least the following items (see Figures 101 and 102): - one or more elements for transforming a non-electrical input quantity to an electrical quantity; - a transmission link for transferral of the electrical quantity to a component for signal conditioning; - a unit for signal conditioning that converts the electrical quantity to a process-relevant electrical signal; - an enclosure for enclosing the above-stated components fully or in parts. Transducers referred to by this standard may also have the following items (see Figures 101 and 102): - a communication and control unit; - a display unit; - control elements such as keys, buttons, switches, etc.; - transducer output signals (for example, switch outputs, alarm outputs) which are clearly assigned to the input signal(s); - transducers with signal conditioning which may be integrated or remote. The manufacturer specifies the environment for which the product is intended to be used and utilizes the corresponding test levels of IEC 61326-1. Additional requirements and exceptions for specific types of transducers are given in the annexes to this standard.
Elektrische Mess-, Steuer-, Regel- und Laborgeräte – EMV-Anforderungen - Teil 2-3: Besondere Anforderungen - Prüfanordnung, Betriebsbedingungen und Leistungsmerkmale für Messgrößenumformer mit integrierter oder abgesetzter Signalaufbereitung (IEC 61326-2-3:2012)
Matériel électrique de mesure, de commande et de laboratoire - Exigences relatives à la CEM - Partie 2-3: Exigences particulières - Configurations d'essai, conditions de fonctionnement et critères d'aptitude à la fonction des transducteurs avec un système de conditionnement du signal intégré ou à distance (CEI 61326-2-3:2012)
La CEI 61326-2-3:2012 spécifie de façon plus détaillée les configurations d'essai, les conditions de fonctionnement et les critères de performance des transducteurs avec un système de conditionnement du signal intégré ou à distance. Elle s'applique uniquement aux transducteurs caractérisés par leur capacité à transformer, avec l'aide d'une source d'énergie auxiliaire, une grandeur non électrique en un signal électrique approprié pour un processus, et à fournir un signal sur un ou plusieurs accès. Elle inclut les transducteurs pour la mesure de grandeurs électrochimiques et biologiques. Les transducteurs couverts par cette norme peuvent être alimentés par une tension alternative (c.a.) ou continue (c.c.) et/ou par accumulateur ou par une alimentation interne. Cette deuxième édition annule et remplace la première édition parue en 2006 et elle constitue une révision technique. Elle inclut la modification technique majeure suivante: mise à jour du document par rapport à la CEI 61326-1:2012.
Električna oprema za merjenje, kontrolo in laboratorijsko uporabo - Zahteve za elektromagnetno združljivost (EMC) - 2-3. del: Posebne zahteve - Preskusna konfiguracija, obratovalni pogoji in merila za lastnosti pretvornikov z vgrajenim ali daljinskim kondicioniranjem signalov (IEC 61326-2-3:2012)
Poleg zahtev standarda IEC 61326-1 ta del določa podrobnejše preskusne konfiguracije, obratovalne pogoje in merila za lastnosti pretvornikov z vgrajenim ali daljinskim kondicioniranjem signalov. Ta standard se uporablja samo za pretvornike, za katere je značilno, da lahko z uporabo pomožnega energijskega vira pretvorijo neelektrično veličino v električni signal, ustrezen za proces, in iznesejo signal v enih ali več vratih. Ta standard vključuje pretvornike za elektrokemijske in biološke merjene veličine. Pretvornike iz tega standarda lahko napaja izmenična ali enosmerna napetost in/ali baterija ali notranje napajanje. Pretvorniki iz tega standarda zajemajo vsaj naslednje elemente (glej sliki 101 in 102): – enega ali več elementov za pretvorbo neelektrične vhodne veličine v električno veličino; – prenosno povezavo za prenos električne veličine v sestavni del za kondicioniranje signalov; – enoto za kondicioniranje signalov, ki električno veličino pretvarja v električni signal, ustrezen za proces; – okrov za zaprtje navedenih sestavnih delov v celoti ali po delih. Pretvorniki iz tega standarda lahko zajemajo tudi naslednje elemente (glej sliki 101 in 102): – komunikacijsko in kontrolno enoto; – prikazno enoto; – kontrolne elemente, kot so ključi, gumbi, stikala itd.; – izhodne signale pretvornika (na primer stikalni izhodi, alarmni izhodi), ki so jasno dodeljeni vhodnim signalom; – pretvornike s kondicioniranjem signalov, ki je lahko vgrajeno ali daljinsko. Proizvajalec določi okolje, v katerem naj bi se izdelek uporabljal, in uporabi ustrezne preskusne ravni iz standarda IEC 61326-1. Dodatne zahteve in izjeme za posamezne vrste pretvornikov so navedene v dodatkih k temu standardu.
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
SIST EN 61326-2-3:2013
01-marec-2013
1DGRPHãþD
SIST EN 61326-2-3:2007
(OHNWULþQDRSUHPD]DPHUMHQMHNRQWURORLQODERUDWRULMVNRXSRUDER=DKWHYH]D
HOHNWURPDJQHWQR]GUXåOMLYRVW(0&GHO3RVHEQH]DKWHYH3UHVNXVQD
NRQILJXUDFLMDREUDWRYDOQLSRJRMLLQPHULOD]DODVWQRVWLSUHWYRUQLNRY]YJUDMHQLPDOL
GDOMLQVNLPNRQGLFLRQLUDQMHPVLJQDORY,(&
Electrical equipment for measurement, control and laboratory use - EMC requirements -
Part 2-3: Particular requirements - Test configuration, operational conditions and
performance criteria for transducers with integrated or remote signal conditioning (IEC
61326-2-3:2012)
Elektrische Mess-, Steuer-, Regel- und Laborgeräte – EMV-Anforderungen - Teil 2-3:
Besondere Anforderungen - Prüfanordnung, Betriebsbedingungen und
Leistungsmerkmale für Messgrößenumformer mit integrierter oder abgesetzter
Signalaufbereitung (IEC 61326-2-3:2012)
Matériel électrique de mesure, de commande et de laboratoire - Exigences relatives à la
CEM - Partie 2-3: Exigences particulières - Configurations d'essai, conditions de
fonctionnement et critères d'aptitude à la fonction des transducteurs avec un système de
conditionnement du signal intégré ou à distance (CEI 61326-2-3:2012)
Ta slovenski standard je istoveten z: EN 61326-2-3:2013
ICS:
19.080 (OHNWULþQRLQHOHNWURQVNR Electrical and electronic
SUHVNXãDQMH testing
33.100.01 Elektromagnetna združljivost Electromagnetic compatibility
na splošno in general
SIST EN 61326-2-3:2013 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
SIST EN 61326-2-3:2013
---------------------- Page: 2 ----------------------
SIST EN 61326-2-3:2013
EUROPEAN STANDARD
EN 61326-2-3
NORME EUROPÉENNE
January 2013
EUROPÄISCHE NORM
ICS 17.220; 19.080; 25.040.40; 33.100 Supersedes EN 61326-2-3:2006
English version
Electrical equipment for measurement, control and laboratory use -
EMC requirements -
Part 2-3: Particular requirements -
Test configuration, operational conditions and performance criteria for
transducers with integrated or remote signal conditioning
(IEC 61326-2-3:2012)
Matériel électrique de mesure, de Elektrische Mess-, Steuer-, Regel- und
commande et de laboratoire - Laborgeräte -
Exigences relatives à la CEM - EMV-Anforderungen -
Partie 2-3: Exigences particulières - Teil 2-3: Besondere Anforderungen -
Configurations d'essai, conditions de Prüfanordnung, Betriebsbedingungen und
fonctionnement et critères de performance Leistungsmerkmale für
des transducteurs avec un système de Messgrößenumformer mit integrierter oder
conditionnement du signal intégré ou à abgesetzter Signalaufbereitung
distance (IEC 61326-2-3:2012)
(CEI 61326-2-3:2012)
This European Standard was approved by CENELEC on 2012-08-14. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the CEN-CENELEC Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the CEN-CENELEC Management Centre has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany,
Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland,
Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Management Centre: Avenue Marnix 17, B - 1000 Brussels
© 2013 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 61326-2-3:2013 E
---------------------- Page: 3 ----------------------
SIST EN 61326-2-3:2013
EN 61326-2-3:2013 - 2 -
Foreword
The text of document 65A/629/FDIS, future edition 2 of IEC 61326-2-3, prepared by SC 65A, "System
aspects", of IEC TC 65, "Industrial-process measurement, control and automation" was submitted to the
IEC-CENELEC parallel vote and approved by CENELEC as EN 61326-2-3:2013.
The following dates are fixed:
• latest date by which the document has (dop) 2013-07-10
to be implemented at national level by
publication of an identical national