IEC 60851-3:2023 is available as IEC 60851-3:2023 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60851-3: 2023 specifies the following test methods for winding wires:
- Test 6: Elongation;
- Test 7: Springiness;
- Test 8: Flexibility and adherence;
- Test 11: Resistance to abrasion;
- Test 18: Heat bonding.
For definitions, general notes on test methods and the complete series of test methods for winding wires, IEC 60851-1 applies. This document also provides recommended friction test methods in Annex B. This fourth edition cancels and replaces the third edition published in 2009, Amendment 1:2013 and Amendment 2:2019. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) Clarification of the distance measurement for determining loss of adhesion in 6.6.3, 6.6.4 for fibre-covered wires and 6.6.5 for tape-wrapped wires.
- Standard93 pagesEnglish and French languagesale 15% off
IEC 60317-93: 2023 specifies the requirements of enamelled rectangular copper winding wire of class 220 with a dual coating. The underlying coating is based on polyester or polyesterimide resin, which be modified providing it retains the chemical identity of the original resin and meets all specified wire requirements. The superimposed coating is based on polyamide-imide resin. NOTE A modified resin is a resin that has undergone a chemical change, or contains one or more additives to enhance certain performance or application characteristics. The range of nominal conductor dimensions covered by this standard is:
width: min. 2,0 mm max. 25,0 mm;
thickness: min. 0,80 mm max. 10,0 mm.
Wires of grade 1 and grade 2 are included in this specification and apply to the complete range of conductors. The specified combinations of width and thickness as well as the specified width/thickness ratio are given in IEC 60317-0-2. This International Standard is to be used in conjunction with IEC 60317-0-2:2020.
- Standard17 pagesEnglish and French languagesale 15% off
IEC 60317-89:2023 specifies the requirements of enamelled round aluminium winding wire of class 200 with a sole coating based on polyesterimide resin, which can be modified providing it retains the chemical identity of the original resin and meets all specified wire requirements. NOTE A modified resin is a resin that has undergone a chemical change, or contains one or more additives to enhance certain performance or application characteristics. The range of nominal conductor diameters covered by this standard is as follows:
grade 1: 0,250 mm up to and including 1,600 mm;
grade 2: 0,250 mm up to and including 5,000 mm.
The nominal conductor diameters are specified in Clause 4 of IEC 60317-0-3:2008 and IEC 60317-0-3:2008/AMD1:2013. This International Standard is to be used in conjunction with IEC 60317-0-3:2008, its Amendment 1 (2013) and its Amendment 2 (2019).
- Standard20 pagesEnglish and French languagesale 15% off
IEC 60317-84:2021 specifies the requirements of enamelled round copper winding wires of class 200 with a sole coating based on polyesterimide resin, which may be modified providing it retains the chemical identity of the original resin and meets all specified wire requirements.
NOTE A modified resin is a resin that has undergone a chemical change or contains one or more additives to enhance certain performance or application characteristics.
The range of nominal conductor diameters covered by this document is as follows:
Grade 1: 0,018 mm up to and including 3,150 mm;
Grade 2: 0,020 mm up to and including 5,000 mm;
Grade 3: 0,0250 mm up to and including 1,600 mm.
The nominal conductor diameters are specified in Clause 4 of IEC 60317-0-1:2013.
- Standard20 pagesEnglish and French languagesale 15% off
IEC 60851-1:2021 specifies the general notes on methods of test for winding wires. It also gives the definitions for terms used in IEC 60851 (all parts). A survey of the contents of IEC 60851-2 to IEC 60851-6 is given in Annex A. This third edition cancels and replaces the second edition published in 1996, and its amendment 1:2003 and amendment 2:2009. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
revision to Clause 2 to update the list of normative references;
revision to 3.2 atmospheric conditions for testing;
addition to 3.2 with remarks concerning frequency and management of tests;
revision to Annex A to update the contents list of IEC 60851 series of tests.
- Standard29 pagesEnglish and French languagesale 15% off
IEC 60172:2020 is available as IEC 60172:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60172:2020 specifies, in accordance with the provisions of IEC 60216-1, a method for evaluating the temperature index of enamelled wire, varnished or unvarnished with an impregnating agent, and of tape wrapped round and rectangular wire, in air at atmospheric pressure by periodically monitoring changes in response to AC proof voltage tests. This procedure does not apply to fibre-insulated wire or wire covered with tapes containing inorganic fibres. NOTE The data obtained according to this test procedure provide the designer and development engineer with information for the selection of winding wire for further evaluation of insulation systems and equipment tests. This fifth edition cancels and replaces the fourth edition published in 2015. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- revision of 3.1, definition of thermal index;
- revision of 3.3, time to failure;
- revisions to 5.1.1 for clarity and to reduce the range wire size range to which the test applies;
- revisions to 5.1.2 for tape wrapped round and enamelled or tape wrapped rectangular wire for clarity;
- revision to Clause 9 to add the correlation coefficient, r to the report.
- Standard49 pagesEnglish and French languagesale 15% off
IEC 60317-70-1:2020 specifies the requirements of polyester glass-fibre wound unvarnished and fused bare, grade 1 or grade 2 enamelled round copper winding wires, temperature index 155. The nominal conductor diameters are specified in Clause 4 of IEC 60317-0-10:2017.
NOTE For this type of wire, the heat shock test is inappropriate and therefore a heat shock temperature cannot be established. Consequently, a class based on the requirements for temperature index and heat shock temperature cannot be specified.
- Standard20 pagesEnglish and French languagesale 15% off
IEC 60317-60-2:2020 specifies the requirements of polyester glass-fibre wound, resin or varnish impregnated, bare or grade 1 or grade 2 enamelled rectangular copper winding wires, temperature index 155. The impregnating agent can be, for instance, epoxy, polyester, or polyesterimide resin based. The range of nominal conductor dimensions covered by this document is:
– width: min. 2,0 mm max. 16,0 mm;
– thickness: min. 0,80 mm max. 5,60 mm.
NOTE For this type of wire, the heat shock test is inappropriate and therefore a heat shock temperature cannot be established. Consequently, a class based on the requirements for temperature index and heat shock temperature cannot be specified.
- Standard20 pagesEnglish and French languagesale 15% off
IEC 60317-60-1: 2020 specifies the requirements of polyester glass-fibre wound fused, unvarnished, bare or grade 1 or grade 2 enamelled rectangular copper winding wires, temperature index 155.
NOTE For this type of wire, the heat shock test is inappropriate and therefore a heat shock temperature cannot be established. Consequently, a class based on the requirements for temperature index and heat shock temperature cannot be specified.
The range of nominal conductor dimensions covered by this document is:
width: min. 2,0 mm max. 16,0 mm;
thickness: min. 0,80 mm max. 5,60 mm.
- Standard20 pagesEnglish and French languagesale 15% off
IEC 60317-70-2:2020 specifies the requirements of polyester glass-fibre wound resin/varnish impregnated bare, grade 1 or grade 2 enamelled round copper winding wires, temperature index 155. The impregnating agent can be, for instance, epoxy, polyester, or polyesterimide resin based. The nominal conductor diameters are specified in Clause 4 of IEC 60317-0-10:2017.
NOTE For this type of wire, the heat shock test is inappropriate and therefore a heat shock temperature cannot be established. Consequently, a class based on the requirements for temperature index and heat shock temperature cannot be specified.
- Standard20 pagesEnglish and French languagesale 15% off
IEC 60317-82: 2020 specifies the requirements of enamelled rectangular copper winding wires of class 200 with a sole coating based on polyesterimide resin, which can be modified provided it retains the chemical identity of the original resin and meets all specified wire requirements.
NOTE A modified resin is a resin that has undergone a chemical change or contains one or more additives to enhance certain performance or application characteristics.
The range of nominal conductor dimensions covered by this document is:
width: min. 2,0 mm max. 16,0 mm;
thickness: min. 0,80 mm max. 5,60 mm. Wires of grade 1 and grade 2 are included in this specification and apply to the complete range of conductors. The specified combinations of width and thickness as well as the specified width/thickness ratio are given in IEC 60317-0-2.
- Standard18 pagesEnglish and French languagesale 15% off
IEC 60317-0-2:2020 is available as IEC 60317-0-2:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60317-0-2:2020 specifies the general requirements of enamelled rectangular copper winding wires. The range of nominal conductor dimensions is given in 4.1 and the relevant specification sheet. This fourth edition cancels and replaces the third edition published in 2013. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- revision to Clause 2 to add new normative references for specifications for copper rods;
- revision to 3.1 to add a new definition for the term “bonding layer”;
- revision to 3.2.1 to the conditions specified for tests to be carried out;
- revision to 4.5 to add requirements for minimal, nomimal and maximal overall dimensions with a bonding layer;
- revision to Clause 5 to reference specifications for rectangular and square copper rod;
- revision to Clause 6 to take into account nominal proof strength;
- revision to 8.2 to the adherence test requirement;
- revision to Clause 18 to make reference to the relevant specification sheet.
- Standard53 pagesEnglish and French languagesale 15% off
IEC 60317-62:2020 is available as IEC 60317-62:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60317-62:2020 specifies the requirements of polyester glass-fibre wound, silicone resin or varnish impregnated bare, grade 1 or grade 2 enamelled rectangular copper winding wires, temperature index 200. The impregnating agent is a silicone containing resin or varnish.The range of nominal conductor dimensions covered by this document is:
- width: min. 2,0 mm max. 16,0 mm;
- thickness: min. 0,80 mm max. 5,60 mm.
NOTE For this type of wire, the heat shock test is inappropriate and therefore a heat shock temperature cannot be established. Consequently, a class based on the requirements for temperature index and heat shock temperature cannot be specified.
This second edition cancels and replaces the first edition published in 2012. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- revision to the title of the standard to more precisely describe the construction of the wire;
- revision to Clause 1, the scope of the standard, to provide more detail of the wire construction;
- revision to 3.2.2, general winding wire requirements of the glass fibre covering.
- Standard20 pagesEnglish and French languagesale 15% off
IEC 60317-27-2:2020 specifies the requirements of paper tape covered round aluminium winding wires. This covering consists of two or more layers of paper tape and is primarily intended for winding coils for oil immersed transformers. The range of nominal conductor diameters covered by this document is:
- 0,500 mm up to and including 5,000 mm.
The nominal conductor diameters are specified in Clause 4 of IEC 60317-0-3:2008 and IEC 60317-0-3:2008/AMD1:2013. The paper tapes included in this document are restricted to those covered in IEC 60554-1 and IEC 60554-3-5.
- Standard21 pagesEnglish and French languagesale 15% off
IEC 60317-25:2020 is available as IEC 60317-25:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60317-25:2020 specifies the requirements of enamelled round aluminium winding wires of class 200 with a dual coating. The underlying coating is based on polyester or polyesterimide resin, which can be modified provided it retains the chemical identity of the original resin and meets all specified wire requirements. The superimposed coating is based on polyamide-imide resin.
NOTE A modified resin is a resin that has undergone a chemical change, or contains one or more additives to enhance certain performance or application characteristics.
The range of nominal conductor diameters covered by this document is:
- Grade 1: 0,250 mm up to and including 3,150 mm;
- Grade 2: 0,250 mm up to and including 5,000 mm.
The nominal conductor diameters are specified in Clause 4 of IEC 60317-0-3:2008 and IEC 60317-0-3:2008/AMD1:2013. This fourth edition cancels and replaces the third edition published in 2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- new 3.2.2 containing general notes on winding wire, formerly a part of the Scope;
- revision to Clause 11 to take into account intermediate nominal conductor diameters;
- revision to Clause 7 to indicate that the springiness test is inappropriate.
- revision to Clause 16 to specify only the percentage of extractable matter and the minimum retained dielectric breakdown voltage.
- Standard20 pagesEnglish and French languagesale 15% off
IEC 60317-0-6:2020 is available as IEC 60317-0-6:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60317-0-6:2020 specifies the general requirements of glass-fibre wound resin or varnish impregnated, bare or enamelled, round copper winding wires. The range of nominal conductor diameters is given in the relevant specification sheet. This second edition cancels and replaces the first edition published in 2001 and Amendment 1:2006. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- revision to 3.3, Appearance;
- revision to Table 1, maximum overall diameter of grade 1 wire over single-glass fibre covering for nominal conductor diameters 1,600 mm - 5,000 mm;
- revision to Table 2, maximum overall diameter of grade 1 wire over double-glass fibre covering for nominal conductor diameters 1,600 mm - 5,000 mm;
clarification in Table 3 measurement of elongation as “minimum elongation %”.
- Standard37 pagesEnglish and French languagesale 15% off
IEC 60317-18:2020 is available as IEC 60317-18:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60317-18:2020 specifies the requirements of enamelled rectangular copper winding wires of class 120 with a sole coating based on polyvinyl acetal or polyvinyl formal resin, which can be modified provided it retains the chemical identity of the original resin and meets all specified wire requirements
NOTE 1 A modified resin is a resin that has undergone a chemical change, or contains one or more additives to enhance certain performance or application characteristics.
NOTE 2 Polyvinyl acetate is a general name for a family of thermoplastic vinyl resins produced by the condensation of polyvinyl alcohol with an aldehyde. Examples are polyvinyl acetal, polyvinyl formal and polyvinyl butyral.
The range of nominal conductor dimensions covered by this document is:
- width: min. 2,0 mm max. 31,5 mm;
- thickness: min. 0,80 mm max. 10,0 mm.
Wires of grade 1 and grade 2 are included in this specification and apply to the complete range of conductors. The specified combinations of width and thickness as well as the specified ratio width/thickness are given in IEC 60317-0-2. This fourth edition cancels and replaces the third edition published in 2004 and Amendment 1:2009. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- modification of the Scope (Clause 1);
- revision to thermal class designation from 105 to 120 in 3.2.2;
- renaming of stretching test to adherence test, and modification to the requirements in 8.2;
- revision to the cut-through requirement in Clause 10.
- Standard20 pagesEnglish and French languagesale 15% off
IEC 60317-12:2020 is available as IEC 60317-12:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60317-12:2020 specifies the requirements of enamelled round copper winding wires of class 120 with a sole coating based on polyvinyl acetal or polyvinyl formal resin, which can be modified provided it retains the chemical identity of the original resin and meets all specified wire requirements.
NOTE 1 A modified resin is a resin that has undergone a chemical change, or contains one or more additives to enhance certain performance or application characteristics.
NOTE 2 Polyvinyl acetal is a general name for a family of thermoplastic vinyl resins produced by the condensation of polyvinyl alcohol with an aldehyde. Examples are polyvinyl acetal, polyvinyl formal and polyvinyl butyral. The range of nominal conductor diameters covered by this document is:
- Grade 1: 0,040 mm up to and including 2,500 mm;
- Grade 2: 0,040 mm up to and including 5,000 mm;
- Grade 3: 0,080 mm up to and including 5,000 mm.
The nominal conductor diameters are specified in Clause 4 of IEC 60317-0-1:2013. This fourth edition of IEC 60317-12 cancels and replaces the third edition published in 2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- modification of the Scope;
- addition of reference to transformer oil resistance test method in Clause 20.
- Standard22 pagesEnglish and French languagesale 15% off
IEC 60317-17:2020 is available as IEC 60317-17:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60317-17:2020 specifies the requirements of enamelled rectangular copper winding wires of class 105 with a sole coating based on polyvinyl acetal resin, which can be modified provided it retains the chemical identity of the original resin and meets all specified wire requirements
NOTE 1 A modified resin is a resin that has undergone a chemical change, or contains one or more additives to enhance certain performance or application characteristics.
NOTE 2 Polyvinyl acetate is a general name for a family of thermoplastic vinyl resins produced by the condensation of polyvinyl alcohol with an aldehyde. Examples are polyvinyl acetal, polyvinyl formal and polyvinyl butyral. The range of nominal conductor dimensions covered by this document is:
- width: min. 2,0 mm max. 31,5 mm;
- thickness: min. 0,80 mm max. 10,00 mm.
Wires of grade 1 and grade 2 are included in this specification and apply to the complete range of conductors. The specified combinations of width and thickness as well as the specified ratio of width/thickness are given in IEC 60317-0-2. This fourth edition cancels and replaces the third edition published in 2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- modification of the Scope (Clause 1);
- renaming of stretching test to adherence test and a modification of the requirement in 8.2.
- Standard20 pagesEnglish and French languagesale 15% off
IEC 60317-27-4:2020 specifies the requirements of paper tape covered rectangular aluminium winding wires. This covering consists of two or more layers of paper tape and is primarily intended for winding coils for oil immersed transformers. The range of nominal conductor dimensions covered by this document is:
– width: min. 2,00 mm max. 16,0 mm;
– thickness: min. 0,80 mm max. 5,60 mm.
The paper tapes included in this document are restricted to those specified in IEC 60554-1 and IEC 60554-3-5.
- Standard21 pagesEnglish and French languagesale 15% off
IEC 60317-27-1:2020 specifies the requirements of paper tape covered round copper winding wires. This covering consists of two or more layers of paper tape and is primarily intended for winding coils for oil immersed transformers. The range of nominal conductor diameters covered by this document is:
– 0,500 mm up to and including 5,000 mm.
The nominal conductor diameters are specified in Clause 4 of IEC 60317-0-1:2013.
The paper tapes included in this document are restricted to those specified in IEC 60554-1 and IEC 60554-3-5.
- Standard21 pagesEnglish and French languagesale 15% off
IEC 60317-61:2020 is available as IEC 60317-61:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60317-61:2020 specifies the requirements of polyester glass-fibre wound, resin or varnish impregnated bare, grade 1 or grade 2 enamelled rectangular copper winding wires, temperature index 180. The impregnating agent can be, for instance, epoxy, polyester, or polyesterimide resin based. NOTE For this type of wire, the heat shock test is inappropriate and therefore a heat shock temperature cannot be established. Consequently, a class based on the requirements for temperature index and heat shock temperature cannot be specified. The range of nominal conductor dimensions covered by this document is:
- width: min. 2,0 mm max. 16,0 mm;
- thickness: min. 0,80 mm max. 5,60 mm.
The specified combinations of width and thickness as well as the specified width/thickness ratio are according to IEC 60317-0-8. This second edition cancels and replaces the first edition published in 2012. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- revision of the title of the standard;
- revision to Clause 1, Scope;
- revision to the descriptions of grades of thickness of polyester glass-fibre coverings in 3.2.2.
- Standard20 pagesEnglish and French languagesale 15% off
IEC 60317-0-4:2020 is available as IEC 60317-0-4:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60317-0-4:2020 specifies general requirements of glass-fibre wound, resin or varnish impregnated, bare or enamelled rectangular copper wire.The range of nominal conductor dimensions is given in 4.1 and the relevant specification sheet. This fourth edition cancels and replaces the third edition published in 2015. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- addition of dimensional requirements for grade 1 enamelled wire in Table 4;
- addition of dielectric breakdown requirements for grade 1 enamelled wire in Table 7.
- addition of requirement for the adherence test in 8.2.1 and 8.2.2.
- Standard49 pagesEnglish and French languagesale 15% off
IEC 60317-72:2020 is available as IEC 60317-72:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60317-72: 2020 specifies the requirements of polyester glass-fibre wound silicone resin/varnish impregnated, bare, grade 1 or grade 2 enamelled round copper winding wire, temperature index 200. NOTE For this type of wire, the heat shock test is inappropriate and therefore a heat shock temperature cannot be established. Consequently, a class based on the requirements for temperature index and heat shock temperature cannot be specified. The nominal conductor diameters are specified in IEC 60317-0-10:2017, Clause 4. This second edition cancels and replaces the first edition published in 2017. The document 55/1768/CDV, circulated to the National Committees as Amendment 1, led to the publication of this new edition. This edition includes the following significant technical changes with respect to the previous edition:
- modification of the title;
- revision to the Scope;
- revision to 3.2.2.
- Standard20 pagesEnglish and French languagesale 15% off
IEC 60317-71:2020 is available as IEC 60317-71:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60317-71:2020 specifies the requirements of polyester glass-fibre wound resin/varnish impregnated, bare, grade 1 or grade 2 enamelled round copper winding wire, temperature index 180. NOTE For this type of wire, the heat shock test is inappropriate and therefore a heat shock temperature cannot be established. Consequently, a class based on the requirements for temperature index and heat shock temperature cannot be specified. The nominal conductor diameters are specified in IEC 60317-0-10:2017, Clause 4. This second edition cancels and replaces the first edition published in 2017. The document 55/1767/CDV, circulated to the National Committees as Amendment 1, led to the publication of this new edition. This edition includes the following significant technical changes with respect to the previous edition:
- modification of the title;
- revision to the Scope;
- revision to 3.2.2.
- Standard20 pagesEnglish and French languagesale 15% off
IEC 60317-27-3:2019 specifies the requirements of paper tape covered rectangular copper winding wires. This covering consists of two or more layers of paper tape and is primarily intended for winding coils for oil immersed transformers. The range of nominal conductor dimensions covered by this document is
- width: min. 2,0 mm max. 31,5 mm;
- thickness: min. 0,80 mm max. 10,0 mm.
The paper tapes included in this document are restricted to those specified in IEC 60554-1 and IEC 60554-3-5.
Keywords: paper tape covered rectangular copper winding wires
- Standard21 pagesEnglish and French languagesale 15% off
- Standard5 pagesEnglish and French languagesale 15% off
IEC 60851-5:2008 specifies the following tests:
- Test 5: Electrical resistance;
- Test 13: Breakdown voltage;
- Test 14: Continuity of insulation;
- Test 19: Dielectric dissipation factor.
Significant revisions to the previous edition include the following points:
- In Subclause 5.3, the addition of the use of carbon brush electrodes for the counting discontinuities during the high voltage continuity test, as an alternative to the V-groove pulley electrode; and
- Clarifications in the breakdown voltage test for round wires larger than 2,500 mm and for fibrous covered wires.
- Standard53 pagesEnglish and French languagesale 15% off
- Standard8 pagesEnglish and French languagesale 15% off
IEC 60317-80: 2019 specifies the requirements of enamelled rectangular copper winding wire of class 120 with a dual coating. The underlying coating is based on polyvinyl acetal resin, which can be modified providing it retains the chemical identity of the original resin and meets all specified wire requirements. The second coating is a bonding layer based on a thermoplastic or thermosetting resin. NOTE A modified resin is a resin that has undergone a chemical change, or contains one or more additives to enhance certain performance or application characteristics. The range of nominal conductor dimensions covered by this document is:
width: min. 2,00 mm max. 16,00 mm;
thickness: min. 0,80 mm max. 5,60 mm.
Wires of grade 1 and grade 2 are included in this specification and apply to the complete range of conductors. The specified combinations of nominal width and thickness as well as the specified ratio width/thickness are given in IEC 60317-0-2:2019.
Keywords: insulated wires used for windings
- Standard20 pagesEnglish and French languagesale 15% off
IEC 60317-0-8:2019 is available as IEC 60317-0-8:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60317-0-8:2019 specifies the general requirements of polyester glass-fibre wound fused, unvarnished, or resin or varnish impregnated bare, or grade 1 or grade 2 or enamelled rectangular copper winding wires. The range of nominal conductor dimensions is given in 4.1 and in the relevant specification sheet. This second edition cancels and replaces the first edition published in 2012. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- revision to the title of the standard indicating that the glass fibre covering is fused and unvarnished;
- revision to subclause 3.2 adding winding wire requirements for the fibrous covering and a list of covering classifications;
- revision to subclause 3.3 requirements for appearance;
- revision to subclause 8.2, adherence test requirements.
Keywords: insulated wires used for windings in electrical equipment
- Standard53 pagesEnglish and French languagesale 15% off
- Standard5 pagesEnglish and French languagesale 15% off
- Standard5 pagesEnglish and French languagesale 15% off
IEC 60317-2:2019 is available as IEC 60317-2:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60317-2:2019 specifies the requirements of solderable enamelled round copper winding wire of class 130 with a dual coating. The underlying coating is based on polyurethane resin, which may be modified providing it retains the chemical identity of the original resin and meets all specified wire requirements. The superimposed coating is a bonding layer based on a thermoplastic resin. NOTE A modified resin is a resin that has undergone a chemical change, or contains one or more additives to enhance certain performance or application characteristics. The range of nominal conductor diameters covered by this standard is:
– Grade 1B: 0,020 mm up to and including 2,000 mm;
– Grade 2B: 0,020 mm up to and including 2,000 mm.
The nominal conductor diameters are specified in Clause 4 of IEC 60317-0-1:2013. This fifth edition cancels and replaces the fourth edition published in 2012. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) addition of heat bonding test loads for nominal conductor diameters up to and including 0,050 mm;
b) addition of pin hole test requirements according to IEC 60317-0-1:2013.
Keywords: insulated wires used for windings
- Standard24 pagesEnglish and French languagesale 15% off
- Standard4 pagesEnglish and French languagesale 15% off
- Standard4 pagesEnglish and French languagesale 15% off
IEC 60317-23:2013 specifies the requirements of solderable enamelled round copper winding wire of class 180 with a sole coating based on polyesterimide resin, which may be modified providing it retains the chemical identity of the original resin and meets all specified wire requirements. NOTE - A modified resin is a resin that has undergone a chemical change, or contains one or more additives to enhance certain performance or application characteristics. The range of nominal conductor diameters covered by this standard is:
- Grade 1: 0,020 mm up to and including 1,600 mm;
- Grade 2: 0,020 mm up to and including 1,600 mm. The nominal conductor diameters are specified in Clause 4 of IEC 60317-0-1:2013. This third edition cancels and replaces the second edition published in 1990, Amendment 1:1997 and Amendment 2:1999. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- new 3.2.2 containing general notes on winding wire, formerly a part of the scope;
- revision to references to IEC 60317-0-1:2013 to clarify that their application is normative;
- consolidation of 17.1 and 17.2 of the solderability requirements;
- modification to Clause 19, Dielectric dissipation factor;
- new Clause 23, Pin hole test. Keywords: requirements of solderable enamelled round copper winding wire, class 180, sole coating based on polyesterimide resin
- Standard20 pagesEnglish and French languagesale 15% off
IEC 60317-20:2013 specifies the requirements of solderable enamelled round copper winding wire of class 155 with a sole coating based on polyurethane resin, which may be modified providing it retains the chemical identity of the original resin and meets all specified wire requirements. NOTE: A modified resin is a resin that has undergone a chemical change, or contains one or more additives to enhance certain performance or application characteristics. The range of nominal conductor diameters covered by this standard is:
- Grade 1: 0,018 mm up to and including 0,800 mm;
- Grade 2: 0,020 mm up to and including 0,800 mm. The nominal conductor diameters are specified in Clause 4 of IEC 60317-0-1:2013. This third edition cancels and replaces the second edition published in 1990, Amendment 1:1997 and Amendment 2:1999. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- new 3.2.2 containing general notes on winding wire, formerly a part of the scope;
- revision to references to IEC 60317-0-1:2013 to clarify that their application is normative;
- modification to Clause 15 to remove specific wire specimen sizes;
- consolidation of 17.1 and 17.2 of the solderability requirements;
- modification to Clause 19, Dielectric dissipation factor;
- new Clause 23, Pin hole test. Key words: requirements of solderable enamelled round copper winding wire, class 155, sole coating based on polyurethane resin
- Standard20 pagesEnglish and French languagesale 15% off
- Standard4 pagesEnglish and French languagesale 15% off
- Standard4 pagesEnglish and French languagesale 15% off
- Standard4 pagesEnglish and French languagesale 15% off
IEC 60317-36:2013 specifies the requirements of solderable enamelled round copper winding wire of class 180 with a dual coating. The underlying coating is based on polyesterimide resin, which may be modified providing it retains the chemical identity of the original resin and meets all specified wire requirements. The superimposed coating is a bonding layer based on a thermoplastic resin. NOTE - A modified resin is a resin that has undergone a chemical change, or contains one or more additives to enhance certain performance or application characteristics. The range of nominal conductor diameters covered by this part is:
- Grade 1B: 0,020 mm up to and including 1,600 mm;
- Grade 2B: 0,020 mm up to and including 1,600 mm. The nominal conductor diameters are specified in Clause 4 of IEC 60317-0-1:2013. This second edition cancels and replaces the first edition published in 1992, Amendment 1:1997 and Amendment 2:1999. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- new 3.2.2 containing general notes on winding wire, formerly a part of the scope;
- revision to references to IEC 60317-0-1:2013 to clarify that their application is normative;
- consolidation of 17.1 and 17.2 of the solderability requirements;
- new Clause 23, Pin hole test. Keywords: requirements of solderable enamelled round copper winding wire, class 180, dual coating
- Standard24 pagesEnglish and French languagesale 15% off
- Standard4 pagesEnglish and French languagesale 15% off
IEC 60317-68:2017 specifies the requirements of enamelled rectangular aluminium winding wire of class 120 with a sole coating based on polyvinyl acetal resin, which may be modified providing it retains the chemical identity of the original resin and meets all specified wire requirements. The range of nominal conductor dimensions covered by this standard is Minimum Maximum Width 2,0 mm 16,0 mm Thickness 0,80 mm 5,60 mm Wires of grade 1 and grade 2 are included in this part of IEC 60317 and apply to the complete range of conductors. The specified combinations of width and thickness as well as the specific ratio width/thickness are given in IEC 60317-0-9:2015.
- Standard20 pagesEnglish and French languagesale 15% off
- Standard4 pagesEnglish and French languagesale 15% off
IEC 60851-2:2009 specifies the following method of test: Test 4: Dimensions. For definitions, general notes on methods of test and the complete series of methods of test for winding wires, see IEC 60851-1. Technical revisions of note include recognition of the use of optical micrometers in determining the dimensions of round and rectangular enamelled wire.
- Standard20 pagesEnglish and French languagesale 15% off
- Standard4 pagesEnglish and French languagesale 15% off
IEC 60317-0-7:2017 establishes general requirements for fully insulated (FIW) zero-defect enamelled round copper wires. The nominal conductor diameter range is given in the relevant technical specification. This second edition cancels and replaces the first edition published in 2012. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- reduction in the number of grades of FIW from 3 through 9 to 4, 6 and 8 only;
- reduction of the wire diameter range from (0,040 to 1,000) mm to (0,090 to 0,900) mm for several requirements;
- revision of Clause 5 to delete the Table 2 resistance requirements;
- revision of Clause 13 to clarify that breakdown is determined when a calculated minimum test voltage is reached, which can be less than 10 000 V;
- expansion of Annex A to include requirements for FIW 3, 5, 7 and 9 and for all grades, wire diameters below 0,090 mm and above 0,900 mm.
- Standard49 pagesEnglish and French languagesale 15% off
IEC 60317-56:2017 specifies the requirements of solderable fully insulated (FIW) zero-defect enamelled round copper wire, class 180, with a single coating based on polyurethane resin, which may be modified providing it retains its chemical identity and satisfies all the required technical specifications. The range of nominal conductor diameters of the wires covered by this standard is as follows: Grade of FIW 4, 6, 8: 0,090 mm up to and including 0,900 mm. Nominal conductor diameters are specified in IEC 60317-0-7. This second edition cancels and replaces the first edition published in 2012. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- Clause 1: revision of the scope, reducing the number of grades of FIW from 3 through 9 to 4, 6 and 8 only;
- Clause 1: revision of the scope, reducing the wire diameter range from (0,040 to 1,600) mm to (0,090 to 0,900) mm;
- addition of an informative annex for abrasion resistance requirements for grades FIW 3 to 9.
- Standard21 pagesEnglish and French languagesale 15% off
IEC 60317-72:2017 specifies requirements of polyester glass-fibre wound fused, silicone resin or varnish impregnated bare, grade 1 or grade 2 enamelled round copper winding wire, temperature index 200. The impregnating agent is a silicone containing resin or varnish. NOTE - For this type of wire, the heat shock test is inappropriate and therefore a heat shock temperature cannot be established. Consequently, a class based on the requirements for temperature index and heat shock temperature cannot be specified.
Keywords: insulated wires used for windings