Standard Specification for Concrete Drain Tile (Metric)

ABSTRACT
This specification covers concrete drain tile, to be used for surface and subsurface drainage. Manufactured drain tile shall be of the following classes: standard-quality concrete drain tile, extra-quality concrete drain tile, heavy-duty extra-quality concrete drain tile, and special-quality concrete drain tile. The concrete shall consist of mineral aggregates, water, and cementitious materials that include Portland cement, fly ash, ground granulated blast furnace slag, aggregates, admixtures and blends, and synthetic fibers. Concrete drain tile shall meet the physical requirement of the specification according to class, depending on soil acidity and sulfate content. Test specimens shall meet the external load crushing strength test requirement of the specification.
SCOPE
1.1 This specification covers concrete drain tile with internal diameters from 100 to 900 mm, that are intended to be used for surface and subsurface drainage.  
1.2 This specification is the metric counterpart of Specification C412.  
Note 1: This specification is a manufacturing and purchase specification only and does not include requirements for bedding, backfill, or the relationship between field load condition and the strength classification of drain tile. However, experience has shown that the successful performance of the product depends upon the proper selection of the class of drain tile, type of bedding and backfill, and care that the installation conforms to the construction specifications. The owner is cautioned that he must correlate the field requirements with the class of drain tile specified and provide for or require inspection at the construction site.

General Information

Status
Historical
Publication Date
30-Sep-2015
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM C412M-15 - Standard Specification for Concrete Drain Tile (Metric)
English language
6 pages
sale 15% off
Preview
sale 15% off
Preview
Technical specification
REDLINE ASTM C412M-15 - Standard Specification for Concrete Drain Tile (Metric)
English language
6 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:C412M −15
Standard Specification for
1
Concrete Drain Tile (Metric)
This standard is issued under the fixed designation C412M; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the U.S. Department of Defense.
1. Scope C1017/C1017M Specification for Chemical Admixtures for
Use in Producing Flowing Concrete
1.1 This specification covers concrete drain tile with inter-
C1116/C1116M Specification for Fiber-Reinforced Concrete
naldiametersfrom100to900mm,thatareintendedtobeused
C1602/C1602M Specification for Mixing Water Used in the
for surface and subsurface drainage.
Production of Hydraulic Cement Concrete
1.2 This specification is the metric counterpart of Specifi-
cation C412.
3. Terminology
NOTE 1—This specification is a manufacturing and purchase specifica-
3.1 Definitions—Fordefinitionsoftermsrelatingtoconcrete
tion only and does not include requirements for bedding, backfill, or the
pipe, see Terminology C822.
relationship between field load condition and the strength classification of
draintile.However,experiencehasshownthatthesuccessfulperformance
4. Classification
of the product depends upon the proper selection of the class of drain tile,
type of bedding and backfill, and care that the installation conforms to the
4.1 Drain tile manufactured according to this specification
construction specifications. The owner is cautioned that he must correlate
shall be of the following four classes:
the field requirements with the class of drain tile specified and provide for
4.1.1 Standard-Quality Concrete Drain Tile, intended for
or require inspection at the construction site.
land drainage of ordinary soils where the tile are laid in
2. Referenced Documents
trenches of moderate depths and widths. Standard-Quality
2
concrete drain tile are not recommended for use where internal
2.1 ASTM Standards:
diameters in excess of 300 mm are required.
C33/C33M Specification for Concrete Aggregates
4.1.2 Extra-Quality Concrete Drain Tile, intended for land
C150/C150M Specification for Portland Cement
drainage of ordinary soils where the tile are laid in trenches of
C260/C260M Specification for Air-Entraining Admixtures
considerable depths or widths, or both.
for Concrete
4.1.3 Heavy-Duty Extra-Quality Concrete Drain Tile, in-
C494/C494M Specification for Chemical Admixtures for
tendedforlanddrainageofordinarysoilswherethetilearelaid
Concrete
in trenches of large depths or widths, or both.
C497M Test Methods for Concrete Pipe, Manhole Sections,
4.1.4 Special-Quality Concrete Drain Tile,intendedforland
or Tile (Metric)
drainage where special precautions are necessary for concrete
C595/C595M Specification for Blended Hydraulic Cements
tile laid in soils that are markedly acid or contain unusual
C618 Specification for Coal Fly Ash and Raw or Calcined
quantities of sulfates (see Section 7), and where the tile are laid
Natural Pozzolan for Use in Concrete
in trenches of considerable depths or widths, or both.
C822 Terminology Relating to Concrete Pipe and Related
4.1.4.1 Where the calculated loads are in excess of the
Products
crushing strengths prescribed in the physical requirements for
C989/C989M Specification for Slag Cement for Use in
extra-quality and special-quality concrete drain tile, tile
Concrete and Mortars
strengths must be specified in advance by the owner.
5. Basis of Acceptance
1
This specification is under the jurisdiction of ASTM Committee C13 on
Concrete Pipe and is the direct responsibility of Subcommittee C13.01 on
5.1 The acceptability of drain tile shall be determined by (1)
Non-Reinforced Concrete Sewer, Drain and Irrigation Pipe.
the results of the physical tests as specified in Section 8, and in
Current edition approved Oct. 1, 2015. Published October 2015. Originally
Test Methods C497M,(2) measurements and inspection to
approved in 1980. Last previous edition approved in 2011 as C412M – 11. DOI:
10.1520/C0412M-15.
ascertain whether the tile conform to the requirements regard-
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
ing dimensions, shape, and freedom from visible defects, and
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
(3) the manufacturer’s certification in writing that the tile have
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website. been made in accordance with any special provisions, such as
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: C412M − 11 C412M − 15
Standard Specification for
1
Concrete Drain Tile (Metric)
This standard is issued under the fixed designation C412M; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the U.S. Department of Defense.
1. Scope
1.1 This specification covers concrete drain tile with internal diameters from 100 to 900 mm, that are intended to be used for
surface and subsurface drainage.
1.2 This specification is the metric counterpart of Specification C412.
NOTE 1—This specification is a manufacturing and purchase specification only and does not include requirements for bedding, backfill, or the
relationship between field load condition and the strength classification of drain tile. However, experience has shown that the successful performance of
the product depends upon the proper selection of the class of drain tile, type of bedding and backfill, and care that the installation conforms to the
construction specifications. The owner is cautioned that he must correlate the field requirements with the class of drain tile specified and provide for or
require inspection at the construction site.
2. Referenced Documents
2
2.1 ASTM Standards:
C33C33/C33M Specification for Concrete Aggregates
C150C150/C150M Specification for Portland Cement
C260/C260M Specification for Air-Entraining Admixtures for Concrete
C494/C494M Specification for Chemical Admixtures for Concrete
C497M Test Methods for Concrete Pipe, Manhole Sections, or Tile (Metric)
C595C595/C595M Specification for Blended Hydraulic Cements
C618 Specification for Coal Fly Ash and Raw or Calcined Natural Pozzolan for Use in Concrete
C822 Terminology Relating to Concrete Pipe and Related Products
C989C989/C989M Specification for Slag Cement for Use in Concrete and Mortars
C1017/C1017M Specification for Chemical Admixtures for Use in Producing Flowing Concrete
C1116C1116/C1116M Specification for Fiber-Reinforced Concrete and Shotcrete
C1602/C1602M Specification for Mixing Water Used in the Production of Hydraulic Cement Concrete
3. Terminology
3.1 Definitions—For definitions of terms relating to concrete pipe, see Terminology C822.
4. Classification
4.1 Drain tile manufactured according to this specification shall be of the following four classes:
4.1.1 Standard-Quality Concrete Drain Tile, intended for land drainage of ordinary soils where the tile are laid in trenches of
moderate depths and widths. Standard-Quality concrete drain tile are not recommended for use where internal diameters in excess
of 300 mm are required.
4.1.2 Extra-Quality Concrete Drain Tile, intended for land drainage of ordinary soils where the tile are laid in trenches of
considerable depths or widths, or both.
4.1.3 Heavy-Duty Extra-Quality Concrete Drain Tile, intended for land drainage of ordinary soils where the tile are laid in
trenches of large depths or widths, or both.
1
This specification is under the jurisdiction of ASTM Committee C13 on Concrete Pipe and is the direct responsibility of Subcommittee C13.01 on Non-Reinforced
Concrete Sewer, Drain and Irrigation Pipe.
Current edition approved Sept. 1, 2011Oct. 1, 2015. Published October 2011October 2015. Originally approved in 1980. Last previous edition approved in 20052011 as
C412M – 05a.C412M – 11. DOI: 10.1520/C0412M-11.10.1520/C0412M-15.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
C412M − 15
4.1.4 Special-Quality Concrete Drain Tile, intended for land drainage where special precautions are necessary for concrete tile
laid in soils that are markedly acid or contain unusual quantities of sulfates (see Section 7), and where the tile are laid in trenches
of considerable depths or widths, or both.
4.1.4.1 Where the calculated loads are in excess of the crushing strengths prescribed in the physical requirements for
extra-quality and special-quality concrete drain tile, tile strengths must be specified in advance by the owner.
5. Basis of Acc
...

Questions, Comments and Discussion