ASTM D3167-10
(Test Method)Standard Test Method for Floating Roller Peel Resistance of Adhesives
Standard Test Method for Floating Roller Peel Resistance of Adhesives
SIGNIFICANCE AND USE
Use this test method for acceptance and process control testing. This test method may be used as an alternative to Test Method D1781 when that facility is not available. This test method is considered more severe since the angle of peel is greater.
SCOPE
1.1 This test method covers the determination of the relative peel resistance of adhesive bonds between one rigid adherend and one flexible adherend when tested under specified conditions of preparation and testing.
1.2 A variation in thickness of the adherends will generally influence the test values. For this reason, the thickness of the sheets used to make the test specimens shall be specified in the material specification. When no thickness is specified, the flexible adherend shall be 0.63 mm (0.025 in.) thick and the rigid adherend shall be 1.63 mm (0.064 in.) thick.
1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
General Information
Relations
Buy Standard
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: D3167 − 10
Standard Test Method for
1
Floating Roller Peel Resistance of Adhesives
This standard is issued under the fixed designation D3167; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
INTRODUCTION
The purpose of this test method is to provide for the determination of the metal-to-metal peel
strength of adhesives by a method that will provide good reproducibility at low-, as well as at
highstrength levels and yet allow for a simple method of test specimen preparation and testing.
The accuracy of the results of strength tests of adhesive bonds will depend on the conditions under
which the bonding process is carried out. Unless otherwise agreed upon between the manufacturer and
the purchaser, the bonding conditions shall be prescribed by the manufacturer of the adhesive. In order
to ensure that complete information is available to the individual conducting the tests, the
manufacturer of the adhesive shall furnish numerical values and other specific information for each of
the following variables:
(1) Procedure for preparation of the surfaces prior to application of the adhesive, the cleaning and
drying of metal surfaces, and special surface treatments such as sanding, which are not specifically
limited by the pertinent test method.
(2) Complete mixing directions for the adhesive.
(3) Conditions for application of the adhesive, including the rate of spread or thickness of film,
number of coats to be applied whether to be applied to one or both surfaces, and the conditions of
drying where more than one coat is required.
(4) Assembly conditions before application of pressure, including the room temperature and length
of time.
(5) Curing conditions, including the amount of pressure to be applied, the length of time under
pressure, and the temperature of the assembly when under pressure. It should be stated whether this
temperature is that of the glue line, or of the atmosphere at which the assembly is to be maintained.
(6) Conditioning procedure before testing, unless a standard procedure is specified, including the
length of time, temperature, and relative humidity.
Arangemaybeprescribedforanyvariablebythemanufactureroftheadhesive,ifitcanbeassumed
by the test operator that any arbitrarily chosen value within such a range or any combination of such
values for several variables will be acceptable to both the manufacturer and the purchaser of the
adhesive.
1. Scope 1.2 A variation in thickness of the adherends will generally
influence the test values. For this reason, the thickness of the
1.1 This test method covers the determination of the relative
sheets used to make the test specimens shall be specified in the
peel resistance of adhesive bonds between one rigid adherend
material specification. When no thickness is specified, the
and one flexible adherend when tested under specified condi-
flexible adherend shall be 0.63 mm (0.025 in.) thick and the
tions of preparation and testing.
rigid adherend shall be 1.63 mm (0.064 in.) thick.
1.3 The values stated in SI units are to be regarded as the
1
This test method is under the jurisdiction of ASTM Committee D14 on
standard. The values given in parentheses are for information
Adhesives and is the direct responsibility of Subcommittee D14.80 on Metal
Bonding Adhesives.
only.
Current edition approved Oct. 1, 2010. Published October 2010. Originally
1.4 This standard does not purport to address all of the
approved in 1973. Last previous edition approved in 2004 as D3167 – 03a (2004).
DOI: 10.1520/D3167-10. safety concerns, if any, associated with its use. It is the
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1
---------------------- Page: 1 ----------------------
D3167 − 10
FIG. 1 Roller Drum Peel Test Fixture
responsibility of the user of this standard to establish appro- adherend from the rigid adherend at a controlled angle of peel
priate safety and health practices and determine the applica- using the test fixture shown in Fig. 1.
bility of regulatory limitations prior to use.
5. Significance and Use
2. Referenced Documents
5.1 Use this test method for acceptance and process control
2
2.1 ASTM Standards:
testing. This test method may be used as an alternative to Test
B209 Specification for Aluminum and Aluminum-Alloy
Method D1781 when that facility is not available. This test
Sheet and Plate
method is considered more severe since the angle of peel is
D907 Terminology of Adhesives
greater.
D1781 Test Method for Climbing Drum Peel for Adhesives
E4 Practices for Force Verification of
...
This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation:D3167–03a(Reapproved2004) Designation: D3167 – 10
Standard Test Method for
1
Floating Roller Peel Resistance of Adhesives
This standard is issued under the fixed designation D3167; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
INTRODUCTION
The purpose of this test method is to provide for the determination of the metal-to-metal peel
strength of adhesives by a method that will provide good reproducibility at low-, as well as at
highstrength levels and yet allow for a simple method of test specimen preparation and testing.
The accuracy of the results of strength tests of adhesive bonds will depend on the conditions under
which the bonding process is carried out. Unless otherwise agreed upon between the manufacturer and
the purchaser, the bonding conditions shall be prescribed by the manufacturer of the adhesive. In order
to ensure that complete information is available to the individual conducting the tests, the
manufacturer of the adhesive shall furnish numerical values and other specific information for each of
the following variables:
(1) Procedure for preparation of the surfaces prior to application of the adhesive, the cleaning and
drying of metal surfaces, and special surface treatments such as sanding, which are not specifically
limited by the pertinent test method.
(2) Complete mixing directions for the adhesive.
(3) Conditions for application of the adhesive, including the rate of spread or thickness of film,
number of coats to be applied whether to be applied to one or both surfaces, and the conditions of
drying where more than one coat is required.
(4) Assembly conditions before application of pressure, including the room temperature and length
of time.
(5) Curing conditions, including the amount of pressure to be applied, the length of time under
pressure, and the temperature of the assembly when under pressure. It should be stated whether this
temperature is that of the glue line, or of the atmosphere at which the assembly is to be maintained.
(6) Conditioning procedure before testing, unless a standard procedure is specified, including the
length of time, temperature, and relative humidity.
Arangemaybeprescribedforanyvariablebythemanufactureroftheadhesive,ifitcanbeassumed
by the test operator that any arbitrarily chosen value within such a range or any combination of such
values for several variables will be acceptable to both the manufacturer and the purchaser of the
adhesive.
1. Scope
1.1 This test method covers the determination of the relative peel resistance of adhesive bonds between one rigid adherend and
one flexible adherend when tested under specified conditions of preparation and testing.
1.2 Avariation in thickness of the adherends will generally influence the test values. For this reason, the thickness of the sheets
used to make the test specimens shall be specified in the material specification. When no thickness is specified, the flexible
adherend shall be 0.63 mm (0.025 in.) thick and the rigid adherend shall be 1.63 mm (0.064 in.) thick.
1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory
limitations prior to use.
1
This test method is under the jurisdiction ofASTM Committee D14 onAdhesives and is the direct responsibility of Subcommittee D14.80 on Metal BondingAdhesives.
Current edition approved AprilOct. 1, 2004.2010. Published April 2004.October 2010. Originally approved in 1973. Last previous edition approved in 20032004 as
D3167 – 03a (2004). DOI: 10.1520/D3167-03AR04.10.1520/D3167-10.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1
---------------------- Page: 1 ----------------------
D3167 – 10
2. Referenced Documents
2
2.1 ASTM Standards:
B209 Specification for Aluminum and Aluminum-Alloy Sheet and Plate
D907 Terminology of Adhesives
D1781 Test Method for Climbing Drum Peel for Adhesives
E4 Practices for Force Verification of Testing Machines
3. Terminology
3.1 Definitions—Many of the t
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.