ASTM A48/A48M-03(2012)
(Specification)Standard Specification for Gray Iron Castings
Standard Specification for Gray Iron Castings
ABSTRACT
This specification covers gray iron castings intended for general engineering use where tensile strength is a major consideration. Castings are classified on the basis of the tensile strength of the iron in separately cast test bars. The surface of the casting shall be free of adhering sand, scale, cracks, and hot tears, as determined by visual examination. The test bars are designated into S, A, B, and C categories, according to the thickness of its controlling wall section. The casting shall be subjected to a tension test to determine its tensile strength.
SCOPE
1.1 This specification covers gray iron castings intended for general engineering use where tensile strength is a major consideration. Castings are classified on the basis of the tensile strength of the iron in separately cast test bars.
1.1.1 This specification subordinates chemical composition to tensile strength.
1.2 Castings produced to this specification are graded on the basis of minimum tensile strength obtained in special test coupons designed to standardize cooling rate. The tensile strength developed in certain casting sections may vary from test coupon values (see X1.2).
1.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.
General Information
Relations
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:A48/A48M −03(Reapproved 2012)
Standard Specification for
1
Gray Iron Castings
This standard is issued under the fixed designation A48/A48M; the number immediately following the designation indicates the year
of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.
A superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the U.S. Department of Defense.
This specification replaces Federal Specification QQ-I-652.
1. Scope 3.1.1 Definitions for many terms common to gray iron
castings are found in Terminology A644.
1.1 This specification covers gray iron castings intended for
general engineering use where tensile strength is a major
4. Classification
consideration. Castings are classified on the basis of the tensile
4.1 Castings ordered and produced in accordance with this
strength of the iron in separately cast test bars.
specificationareclassifiedintoanumberofgradesbasedonthe
1.1.1 This specification subordinates chemical composition
properties of separately cast test bars (Table 1, Table 2). Each
to tensile strength.
class is designated by a number followed by a letter. The
1.2 Castings produced to this specification are graded on the
number indicates the minimum tensile strength of the sepa-
basis of minimum tensile strength obtained in special test
rately cast test bar, and the letter indicates the size of the test
coupons designed to standardize cooling rate. The tensile
bar. Examples of proper designations are as follows:
strength developed in certain casting sections may vary from
Gray Iron Castings, ASTM Specification A48, Class 30B.
test coupon values (see X1.2).
Gray Iron Castings, ASTM Specification A48, Class 40C.
1.3 The values stated in either SI units or inch-pound units
5. Ordering Information
are to be regarded separately as standard. The values stated in
5.1 Orders for material to this specification shall include the
each system may not be exact equivalents; therefore, each
following information:
system shall be used independently of the other. Combining
5.1.1 ASTM designation number and year of issue,
values from the two systems may result in non-conformance
5.1.2 Class of iron required (see 4.1, Table 1, and Table 2),
with the standard.
5.1.3 The size of the separately cast test bar (letter
classification—A, B, C, or S) that best represents the thickness
2. Referenced Documents
of the controlling section of the casting (see Table 3),
2.1 ASTM Standards:
5.1.4 The tension test specimen (B or C) to be machined
A644 Terminology Relating to Iron Castings
from test bar C (see 13.3, Table 4, and Fig. 1),
E8 Test Methods for Tension Testing of Metallic Materials
5.1.5 The tension test specimen to be machined from test
2.2 Military Standard:
bar S (see 13.4, Table 4, and Fig. 1),
2
MIL-STD-129 Marking for Shipment and Storage
5.1.6 Lot size (see Section 10),
5.1.7 Special requirements (see Section 6),
2.3 Federal Standard:
5.1.8 Saving tested specimens or unbroken test bars (see
Federal Standard No. 123 Marking for Shipment (Civil
2
15.1), and
Agencies)
5.1.9 Special preparation for delivery (see Section 19).
3. Terminology
6. Special Requirements
3.1 Definitions:
6.1 When agreed upon in writing between the manufacturer
and the purchaser, it may be necessary for the castings to meet
special requirements as to hardness, chemical composition,
1
This specification is under the jurisdiction of ASTM Committee A04 on Iron
microstructure, pressure tightness, radiographic soundness,
CastingsandisthedirectresponsibilityofSubcommitteeA04.01onGreyandWhite
dimensions, surface finish, and so forth.
Iron Castings.
Current edition approved Oct. 1, 2012. Published November 2012. Originally
7. Tensile Requirements
approved in 1905. Last previous edition approved in 2008 as A48/A48M – 03
(2008). DOI: 10.1520/A0048_A0048M-03R12.
7.1 Test bars representing castings conforming to this speci-
2
Available from Standardization Documents Order Desk, DODSSP, Bldg. 4,
fication shall meet the requirements for tensile strength as
Section D, 700 Robbins Ave., Philadelphia, PA 19111-5098, http://
www.dodssp.daps.mil. described in Table 1 and Table 2.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1
---------------------- Page: 1 ----------------------
A48/A48M−03 (2012)
TABLE 1 Requirements for Tensile Strength of Gray Cast Irons in TABLE 2 Requirements for Tensile Strength of Gray Cast Irons in
Separately Cast Test Bars (Inch-Pound) Separately Cast Test Bars (Metric)
Tensile Strength, Nominal Test Bar Tensile Strength, Nominal Test Bar
Class Class
min, ksi Diameter, in. min, ksi [MPa] Diameter, in. [mm]
No. 20 A 20 0.8 No. 150A 150
...
Questions, Comments and Discussion