ASTM C412M-05
(Specification)Standard Specification for Concrete Drain Tile (Metric)
Standard Specification for Concrete Drain Tile (Metric)
SCOPE
p>1.1 This specification covers concrete drain tile with internal diameters from 100 to 900 mm, that are intended to be used for surface and subsurface drainage.
1.2 This specification is the metric counterpart of Specification C 412.
Note 1—This specification is a manufacturing and purchase specification only and does not include requirements for bedding, backfill, or the relationship between field load condition and the strength classification of drain tile. However, experience has shown that the successful performance of the product depends upon the proper selection of the class of drain tile, type of bedding and backfill, and care that the installation conforms to the construction specifications. The owner is cautioned that he must correlate the field requirements with the class of drain tile specified and provide for or require inspection at the construction site.
General Information
Relations
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: C 412M – 05
METRIC
Standard Specification for
1
Concrete Drain Tile [Metric]
This standard is issued under the fixed designation C 412M; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope C 989 Specification for Ground Granulated Blast-Furnace
Slag for Use in Concrete and Mortars
1.1 This specification covers concrete drain tile with inter-
naldiametersfrom100to900mm,thatareintendedtobeused
3. Terminology
for surface and subsurface drainage.
3.1 Definitions—For definitions of terms relating to con-
1.2 This specification is the metric counterpart of Specifi-
crete pipe, see Terminology C 822.
cation C 412.
4. Classification
NOTE 1—This specification is a manufacturing and purchase specifica-
tion only and does not include requirements for bedding, backfill, or the
4.1 Drain tile manufactured according to this specification
relationship between field load condition and the strength classification of
shall be of the following four classes:
draintile.However,experiencehasshownthatthesuccessfulperformance
4.1.1 Standard-Quality Concrete Drain Tile, intended for
of the product depends upon the proper selection of the class of drain tile,
land drainage of ordinary soils where the tile are laid in
type of bedding and backfill, and care that the installation conforms to the
construction specifications. The owner is cautioned that he must correlate trenches of moderate depths and widths. Standard-Quality
the field requirements with the class of drain tile specified and provide for
concrete drain tile are not recommended for use where internal
or require inspection at the construction site.
diameters in excess of 300 mm are required.
4.1.2 Extra-Quality Concrete Drain Tile, intended for land
2. Referenced Documents
drainage of ordinary soils where the tile are laid in trenches of
2
2.1 ASTM Standards:
considerable depths or widths, or both.
C33 Specification for Concrete Aggregates
4.1.3 Heavy-Duty Extra-Quality Concrete Drain Tile, in-
C 150 Specification for Portland Cement
tendedforlanddrainageofordinarysoilswherethetilearelaid
C 497M Test Methods for Testing Concrete Pipe, Manhole
in trenches of large depths or widths, or both.
Sections, or Tile [Metric]
4.1.4 Special-Quality Concrete Drain Tile,intendedforland
C 595 Specification for Blended Hydraulic Cements
drainage where special precautions are necessary for concrete
C 618 Specification for Coal Fly Ash and Raw or Calcined
tile laid in soils that are markedly acid or contain unusual
Natural Pozzolan for Use in Concrete
quantities of sulfates (see Section 7), and where the tile are laid
C 670 Practice for Preparing Precision and Bias Statements
in trenches of considerable depths or widths, or both.
for Test Methods for Construction Materials
4.1.4.1 Where the calculated loads are in excess of the
C 822 Terminology Relating to Concrete Pipe and Related
crushing strengths prescribed in the physical requirements for
Products
extra-quality and special-quality concrete drain tile, tile
strengths must be specified in advance by the owner.
1
This specification is under the jurisdiction of ASTM Committee C13 on 5. Basis of Acceptance
Concrete Pipe and is the direct responsibility of Subcommittee C13.01 on
5.1 The acceptability of drain tile shall be determined by (1)
Non-Reinforced Concrete Sewer, Drain, and Irrigation Pipe.
the results of the physical tests as specified in Section 8, and in
Current edition approved Oct. 15, 2005. Published November 2005. Originally
approved in 1980. Last previous edition approved in 2004 as C 412M – 04.
Test Methods C 497M,(2) measurements and inspection to
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
ascertain whether the tile conform to the requirements regard-
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
ing dimensions, shape, and freedom from visible defects, and
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website. (3) the manufacturer’s certification in writing that the tile have
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1
---------------------- Page: 1 ----------------------
C412M–05
been made in accordance with any special provisions, such as 7.1.1.2 Where the sulfates are chiefly sodium or magne-
strength, absorption, permeability, type of cement, admixture, sium, singly or in combination, from 400 to 2000 ppm in the
curing conditions, etc. soilordrainagewater,sampl
...