Standard Safety Specification for Residential Pool Alarms

ABSTRACT
This specification deals with the performance requirements for pool alarms for residential swimming pools and spas. This specification covers devices that provide for rapid and automatic detection and alarm in cases of unintentional, unsupervised or accidental entry of a child one year of age or older into the water of swimming pools or spas. This specification is not intended to replace other standard safety requirements that should be in place, that is, adult supervision, fences, gates, locks, and so forth. This specification covers four different types of alarms: Type A, Surface—Pool alarm floating on water surface; Type B, Subsurface—Pool alarm located below the water surface; Type C, Pool Perimeter—Pool alarm located such as to detect movement at the perimeter of or above the water surface; and Type D, Personal Immersion Alarm—Pool alarm device located on the person(s).
SCOPE
1.1 This safety specification covers safety and performance requirements for pool alarms for residential swimming pools and spas.  
1.2 This safety specification describes devices intended to improve personal safety and reduce injuries or deaths.  
1.3 This safety specification covers devices that provide for rapid and automatic detection and alarm in cases of unintentional, unsupervised or accidental entry of a child one year of age or older into the water of swimming pools or spas.  
1.4 This safety specification is not intended to replace other standard safety requirements that should be in place, that is, adult supervision, fences, gates, locks, and so forth.  
1.5 This safety specification covers four different types of alarms.  
1.6 The detection criteria for this safety specification is for a child one year of age and older.  
1.7 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.  
1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.9 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

General Information

Status
Published
Publication Date
30-Sep-2019
Technical Committee
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM F2208-08(2019) - Standard Safety Specification for Residential Pool Alarms
English language
4 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Designation: F2208 −08 (Reapproved 2019)
Standard Safety Specification for
Residential Pool Alarms
This standard is issued under the fixed designation F2208; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
INTRODUCTION
According to Consumer Product Safety Commission (CPSC) data, it is estimated that each year on
average 256 children under 5 years of age drown in swimming pools, with most deaths occurring in
residential settings. Additionally, each year on average over 2000 children under 5 years of age are
treated in hospital emergency rooms for pool submersion injuries.
1. Scope ization established in the Decision on Principles for the
Development of International Standards, Guides and Recom-
1.1 This safety specification covers safety and performance
mendations issued by the World Trade Organization Technical
requirements for pool alarms for residential swimming pools
Barriers to Trade (TBT) Committee.
and spas.
1.2 This safety specification describes devices intended to
2. Referenced Documents
improve personal safety and reduce injuries or deaths.
2.1 ANSI Standards:
1.3 This safety specification covers devices that provide for
ANSI Z535.4 Product Safety Signs and Labels
rapid and automatic detection and alarm in cases of
ANSI Z535.6 Product Safety Information and Product
unintentional, unsupervised or accidental entry of a child one
Manuals, Instructions, and Other Collateral Materials
year of age or older into the water of swimming pools or spas.
3. Terminology
1.4 This safety specification is not intended to replace other
standard safety requirements that should be in place, that is, 3.1 Definitions of Terms Specific to This Standard:
adult supervision, fences, gates, locks, and so forth. 3.1.1 lot, n—normal production run or in the case of
imports, a shipment of items produced in the same time frame.
1.5 This safety specification covers four different types of
3.1.2 pool alarm, n—device designed to provide a rapid
alarms.
detection and automatic alarm in incidents of accidental,
1.6 The detection criteria for this safety specification is for
unintentional or unsupervised entry of a child one year of age
a child one year of age and older.
or older into the water of a swimming pool or spa.
1.7 The values stated in inch-pound units are to be regarded
as standard. The values given in parentheses are mathematical 4. Classification
conversions to SI units that are provided for information only
4.1 Types:
and are not considered standard.
4.1.1 TypeA, Surface—Poolalarmfloatingonwatersurface.
1.8 This standard does not purport to address all of the
4.1.2 Type B, Subsurface—Pool alarm located below the
safety concerns, if any, associated with its use. It is the
water surface.
responsibility of the user of this standard to establish appro-
4.1.3 Type C, Pool Perimeter—Pool alarm located such as
priate safety, health, and environmental practices and deter-
to detect movement at the perimeter of or above the water
mine the applicability of regulatory limitations prior to use.
surface.
1.9 This international standard was developed in accor-
4.1.4 Type D, Personal Immersion Alarm—Pool alarm de-
dance with internationally recognized principles on standard-
vice located on the person(s).
5. Performance Requirements
This specification is under the jurisdiction of ASTM Committee F15 on
5.1 General:
Consumer Products and is the direct responsibility of Subcommittee F15.49 on Pool
Safety Standards.
Current edition approved Oct. 1, 2019. Published October 2019. Originally
approved in 2002. Last previous edition approved in 2014 as F2208 – 08 (2014). Available from American National Standards Institute (ANSI), 25 W. 43rd St.,
DOI: 10.1520/F2208-08R19. 4th Floor, New York, NY 10036, http://www.ansi.org.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
F2208 − 08 (2019)
5.1.1 Alarms shall sound both at poolside and inside any lator (CIS) is 20 6 0.5 lb (9.07 6 0.23 kg) and shall be filled
adjacent residence or building of occupancy via a remote with water.The CIS to meet these criteria shall be a mannequin
receiver within 20 s or less when tested in accordance with called Rescue Timmy. Rescue Timmy meets the requirements
Section 6. of the National Center(s) for Disease Control for a one-year-
5.1.2 The operational condition of a swimming pool alarm, old child. All testing shall be done in a 16-by-32 ft (4.87-by-
either on or off, shall be indicated with an energized lamp or 9.75 m) swimming pool with a minimum depth of 36 in. (91
other distinctive indicator, visible from a distance of 10 61ft cm). Any pool shape is sufficient as long as the pool measures
(3 6 0.3 m) at angles of 45 6 5° perpendicular to the unit to at some point 16 by 32 ft (4.87 by 9.75 m). During all drop
indicate the operability of the product. tests, both fans shall be operating as described in 6.3. During
5.1.3 Pool alarms shall have a minimum sound pressure all drop tests, the pump and filter shall be on and operating.
rating of 85 dBA at 10 ft (3.5 m) for 3 min.
6.2 To begin each drop test the pool shall be in a non-
5.1.4 If the device is battery operated, there shall be a
operational state, that is, pump, filter, and fans off for a
low-battery indicator. A low-battery condition is defined as an
minimum of 10 min. All drop tests are conducted two times
inability to meet the requirements of 5.1.3.
with the second drop test following the completion of the first
5.1.5 Pool alarms shall automatically reset.
drop test using the testing sequence A, B, C, as described
5.1.6 Pool alarm manufacturers who employ wireless com-
below.
munication (RF) shall comply with all relevant provisions of
A. Turn pump, filter, and both fans on for 2 min.
FCC Part-15 rules for unlicensed radio frequency devices
B. Initiate any one of the five (5) the drop tests.
including the required compliance labeling and statement.
C.Twominutesafterinitiatingthedroptestturnpump,filter,
5.1.7 If the alarm deactivates or has reduced sensitivity due
and fans off for 10 min, repeat test.
to environmental factors, the alarm shall indicate this in both a
D. Each of the two drop tests shall follow the same sequence
visual and audible manner.
(A, B, C).
5.2 Type A, Surface Alarm: 6.2.1 Vertical Drop Test:
5.2.1 TypeAalarmsshallprovidefortheautomaticsoundof 6.2.1.1 Position of the pool alarm shall be in accordance
the alarm when tested in accordance with 6.1. For alarms with with manufacturer’s specifications.
variable sensitivity, the setting shall be set at the least sensitive, 6.2.1.2 All vertical drop tests shall be conducted using a
according to manufacturer’s instructions. ramp (see Fig. 1). Material for the ramp shall be 10- to 20-mm
5.2.2 Type A alarms shall not alarm when tested in accor- thick polytetrafluoroethylene (PTFE) or fluorinated ethylene
dance with 6.3. For alarms with variable sensitivity, the setting propylene (FEP), approximately 2 ft (0.6 m) wide and 4 ft (1.2
shall be set at the most sensitive, according to manufacturer’s m) in length. A sheet of polypropylene precision woven mesh
instructions. that is 12 in. in width and 30 in. in length with 20.3 by 20.3
openings per square inch and a thread diameter of .0173 in.
5.3 Type B, Subsurface Alarm:
shall be placed between Rescue Timmy and the ramp to enable
5.3.1 Type B alarms shall provide for the automatic sound
Rescue Timmy to slide off the ramp in a consistent manner.
of the alarm when tested in accordance with 6.1. For alarms
The ramp shall be located on the 16-ft (4.87-m) side of the pool
with variable sensitivity, the setting shall be set at the least
between the two fans approximately in the middle.
sensitive, according to manufacturer’s instructions.
6.2.1.3 Place and secure Rescue Timmy (CIS) on his stom-
5.3.2 Type B alarms shall not alarm when tested in accor-
ach at the lower end of the ramp with the head even with the
dance with 6.3. For alarms with variable sensitivity, the setting
end of the ramp for a head-first intrusion. Use a string and
shall be set at the most sensitive, according to manufacturer’s
sinker to maintain the ramp 6 6 0.5 in. (15 6 1.3 cm) above
instructions.
the water and have the ramp at a 35 6 1° angle. Release
5.4 Type C, Pool Perimeter Alarm:
Rescue Timmy into the water head first. This test shall be
5.4.1 Type C alarms shall provide for the automatic sound
repeated two times (see 6.1).
of the alarm when tested in accordance with 6.4, according to
6.2.1.4 Place and secure RescueTimmy (CIS) on his back at
manufacturer’s instructions.
the end of the ramp with the feet even with the lower end of the
5.4.2 Type C alarms shall not
...

Questions, Comments and Discussion